HomeMy WebLinkAbout5805 TANGELO DR FAQ" STATE OF FLORIDA
r DEPARTMENT OF HEALTH
s '4yQ ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
'.y t CONSTRUCTION INSPECTION AND FINAL APPROVAL
Who WE .
APPLICANT: Adams Homes of Northwest Florida, Inc
AGENT: Benjamin Drew"s Plumbing & Drain Services
PROPERTY ADDRESS: 5805 Tangelo Dr Fort Pierce, FL 34982
APPLICATION #:AP1464965
PERMIT #:56-SF-2034841
DOCUMENT # : F 11679367
DATE PAID : 01 /30/2020
FEE PAID .545.00
RECEIPT #:56-PID-4284796
LOT: 34
BLOCK: 76
SUBDIVISION:
Indian River Estates ID#: 3402-610-0179-000-1
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH
STATUTE OR
RULE AND MUST BE CORRECTED.
TANK
INSTALLATION
SETBACKS
[ ] [01]
TANK SIZE [11 1090.00 [21 483.00
[ ] [27]
SURFACE WATER
FT
[ ] [021
TANK MATERIAL Polypropylene
[ ] [281
DITCHES 17
FT
[ ] [03]
OUTLET DEVICE
[ ] [291
PRIVATE WELLS
FT
[ ] [04]
MULTI -CHAMBERED [ Y N ]
[ ] [30]
PUBLIC WELLS
FT
[ ] [051
OUTLET FILTER Polylok PL-68
[ ] [311
IRRIGATION WELLS
FT
[ ] [061
LEGEND 1. 70-143-11DC4 2. 70-143-54SC4
[ ] [321
POTABLE WATER 7
FT
[ ] [07]
WATERTIGHT
[ ] [331
BUILDING FOUNDATIONS 5.5
FT
[ ] [081
LEVEL
[ ] [34]
PROPERTY LINES 10
FT
[ ] [09]
DEPTH TO LID
[ ] [351
OTHER
FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ] [101
AREA [1] 7 [21 SQFT
[ ] [361
DRAINFIELD COVER
[ ] [111
DISTRIBUTION BOX HEADER X
[ ] [371
SHOULDERS
[ ] [12]
NUMBER OF DRAINLINES 1, 7.00 2.
[ ] [381
SLOPES
[ ] [131
DRAINLINE SEPARATION
[ ] [391
STABILIZATION 08/09/2021
[ ] [14]
DRAINLINE SLOPE
[ ] [15]
DEPTH OF COVER
ADDITIONAL
INFORMATION
[ ] [161
ELEVATION [ ABOVE / BELOW ]BM 6.00
[ ] [40]
UNOBSTRUCTED AREA
[ ] [17]
SYSTEM LOCATION
[ ] [41]
STORMWATER RUNOFF
[ ] [181
DOSING PUMPS 1.00
[ ] [42]
ALARMS
[ ] [191
AGGREGATE SIZE
[ ] [431
MAINTENANCE AGREEMENT
[ ] [201
AGGREGATE EXCESSIVE FINES
[ ] [44]
BUILDING AREA
[ ] [211
AGGREGATE DEPTH
[ ] [451
LOCATION CONFORMS WITH SITE PLAN
FILL
/ EXCAVATION MATERIAL
[ ] [461
FINAL SITE GRADING
[ ] [221
FILL AMOUNT
I. ] [471
CONTRACTOR Bruce T Mc Cullers (Reliable T
[ ] [23]
FILL TEXTURE
[ ] [48]
OTHER ADS/PSA BIO DIFFUSER Bio
2 (dua
[ ] [241
EXCAVATION DEPTH
ABANDONMENT
[ ] [251
AREA REPLACED
[ ] [491
TANK PUMPED
[ ] [26]
REPLACEMENT MATERIAL
[ ] [501
TANK CRUSHED & FILLED
Comments: Comments
are on page 2.
/
St. Lucie CHD
DATE: 05/17/2021
CONSTRUCTION [ APPROVED
DISAPPROVED
] E vironmental Specialis II Bri n J Ingram (EN
RONMENTAL HEALTH)
FINAL SYSTEM [ APPROVED / DISAPPROVED
]
t. Lucie CHD
DATE: 08/09/2021
E ironmental Sp cialist I Ni le Mon a
orida Department of He
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous
editions which may not be us d
Incorporated: 64E-6.003, FAC
Page 2 of 3
EH Database v 1.0.1
AP1464965 EID2034841
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT
CONSTRUCTION INSPECTION
Violation Number Comment
Comments
AND DISPOSAL SYSTEM
AND FINAL APPROVAL
APPLICATION # : AP 1464965
PERMIT # : 56-S F-2034841
DOCUMENT # : FI 1679367
DATE PAID : 01 /30/2020
FEE PAID :545.00
RECEIPT #:56-PID-4284796
The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400
gpd.
New ST, filter, DT, libertyl/3 hp pump, and 7x32' long BED DF installed. No violations, system ok to cover, contractor notified
Dnsite. Needs final inspection for mound system and final site grading.
Final inspection approved. Emailed copy to contractor and building department. NMM
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1464965 EID2034841