Loading...
HomeMy WebLinkAboutLetter; Elect Panel ScheduleMay 10, 2021 Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave. Fort Pierce, Fl. 34982 (772)462-2172 RE: Permit # D.R. Horton Homes Creekside Lot 30 Model 4EAB Aria Response Letter ARCHITECTS Design Group. For the above listed project, Please refer to the Elect panel Schedule attached for a clarified print. feel free to contact me. 2194 Hwy AIA, Suite 301 Indian Harbour Beach, FL 32937 • Phone: (321) 802-3591 www.abdesigngroup.com ARCH I T E C T S Design Group LLC WP Panel MAIN -A PANEL: 8/16 wp crt. breaker VOLTAGE: 120 / 240 V -1 Ph MAIN: 150 Amp M.C.B FEEDER: 3- #1 Cu THWN & 1- #6 Cu (G) in 1 1/2' C. OR 3-#2/0 AL THWN & 1-#6 Cu (G) in 1 1/2" C. Wire. Pole Bkr Description Watts . Circuit Circuit Watts Description Bkr Pore Wire 012 .1 20 Exterior Receptacle GFI for TUG 120D 1 2 Space #12 2 20 irrigation Pump 1000 3 4 Space 5 6 4680 A/C C.U: 1 30 2 #10 Space 7 8 PANEL - A PANEL: 42 crt breaker VOLTAGE:120 / 240 V -1 Ph MAIN: 150 Amp M.L.O. FEEDER: 3-#1 Cu THWN & 1- #6 Cu (G) In 1 1/2" C. OR 3-#210 AL THWN & 1- #6 Cu (G) in 1 1/2" C. Wire Pole Bkr Description Watts Circuit Circuit Watts Description Bkr Pole Wire # 12 1 20 Small Appliance 1500 1 2 8000 Range 50 2 46 #12 1 20 Microwave / Hood GFI 1800 3 4 #12 1 20 Small Appliance 1500 5 6 4500 Water Heater 25 2 #10 #12 1 20 Refrigerator 1500 7 8 # 12 1 20 Dining Receptacles AFCI 1500 9 10 120D Disposal GFI 20 1 #12 #12' 1 20 Bath GFI Recelades 1200 11 12 1500 Dishwasher GFI 20 1 #12 i #12 1 20 Foyer / Hall / Laundry AFCI 1200 13 14 500D Dryer GFI 30 2 #10 #14 1 15 Great Room, Lanai & Dining Lights AFCI 900 15 is Space 17 18 1500 Washer GFI 20 1 #12 #14' 1 15 SD & C!O AFCI 900 19 20 1000 Garage Door Opener GFI 20 1 #12 012 1 20 Bed #2 & #3 / Beth #2 AFCI 1200 21 22 120D Garage! Exterior Us & Receptacles AFCI 20 1 #12 Space 23 24 900 Bed #1 AFCI 15 1 #14 Space 25 1 26 90o Bath#1 AFCI 15 1 #14 27 28 1000 opt 3-Car Garage Door Opener GFI 20 1 #12 Space 29 30 1000 Inigation controls only 20 1 #12 Space 31 32 Spa - Space 33 34 6xce P2 Space 35 36 Space Space 37 38 Space #8 35 A/C AHU-1 Heater 5 KVA at 65% 6120 39 40 Space 41 42 Space. Load subject to demand factor calculations / line 15400 2770D Load subject to demand factor calculations ! line eman actor Calculations: ABBREVIATIONS: AFCI: ARC FAULT 'CIRCUIT INTERRUPTER NC: NON -COINCIDENT LOAD GFI: GROUND FAULT INTERRUPTER Total load subject to demand factor 43100 First 10000 walls at 100% 10000 RemainIng watts at 40% 13240 Total A!C load 9800 10%'for future growth 2194 Hwy AIA, Suite 301 Indian Harbour Beach, FL 32937 • Phone: (321) 802-3591 www.abdesigngroup.com