Loading...
HomeMy WebLinkAboutPROPOSED PLAN LAYOUTE 0 T a w N N 0 0 m 0 a EXISTING BUILDING — (TO REMAIN) AIF A . ORAO 104 Saint Lucie County Property Appraiser - THE ATTACHED PLANS HAVE BEEN DESIGNED FORAND ARE IN ` COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE (WIND); (FBC) EXISTING BUILDING 7th EDITION; AND " (FBC) BUILDING 7th EDITION FOR THIS PROJECT WHICH INCLUDE. AND MAY NOT BE LIMITED TO; Surface Roughness: C North Site Exposure Category: D ProEPt IdentiflCdt1011k, p y Wind Zone (4) Site Address: 3200 Si LUCIE BL � USA Type: 4g0� - yfi THE 2020 BUILDING CODE FINAL FIGURE "A" (FIGURE 1609A ULTIMATE DESIGN WIND SPEEDS) USING A MAXIMUM (Vult) WIND VELOCITY OF 160 MPH. ENGINEERING - Sec/Town/Range: 29/34S/40E Account #: 10037 '•'.:. DESIGN IS SITE SPECIFIC AND NOT VALID WITHOUT C x THE AUTHORIZED SIGNATURE AND SEAL OF A REGISTERED " Parcel ID: 1428-702-1492-000-4 Map ID: 14/295 PROFESSIONAL ENGINEER. THESE NOTES ARE PART OF THE CONSTRUCTION DOCUMENTS AND MUST BE READ AND ADHERED ., TOBYALL APPLICABLE SUBS. USE FIGURED DIMENSIONS ONLY. .:; ,7 Jurisdiction: Saint Lucie County Zoning: Industrial `, IF A DISCREPANCY OCCURS DO NOT SCALE THE DRAWING, CONTACT `'j' THE ENGINEER OF RECORD. THESE DOCUMENTS TO WHICH I HAVE AFFIXED MY SIGNATURE AND SEAL WERE PREPARED BY ME AND/ORUNDER MY DIRECT -"; SUPERVISION. THESE DOCUMENTS ARE INSTRUMENTS OF USE AND ARE PROTECTED BY THE COPYRIGHT LAW OF THE U.S. THEY MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT WRITTEN PERMISSION OF THE ARCHITECT/ENGINEER. THE CERTIFICATION CONTAINED HEREIN APPLIES ONLY TO THOSE STRUCTURAL ELEMENTS COVERED UNDER THE 2020 FLORIDA BUILDING CODE AS THEY PERTAIN TO THE EXISTING FOUNDATION I ANCHOR SYSTEM OF THE STORAGE TANKS. THE STORAGE TANKS .. 4 '4 tw- e0. f IxLD I� ry ARE DESIGNED AND CERTIFIED BY THE TANK MANFACTURERS. 04 6 A 5.10 EXISTING BUILDING } 02 LOCATION MAP (TO REMAIN) I 1 North(TYP.) i , SCALE: nts 6" CONC. FILLED STEEL ' n r --- ----- ----- ---, r -- - -- -.--1 r•--- ----- ----- ---- T '` BOLLARD(TYP) ;---- ----- --- -- i G r-.-- WNIN -, S' H. CORNER BOLLARD ALL O.H. GARAGE DOORS I i I> i i� •i I i ii. -�i: RECESS IN PANEL I �� ? 11 UN 5A 7151-277777 7Z4" N TOR 150 BL" END NK � 4 - 5 BB ANK e 01 PROPOSED DISTILLERY TANK PLAN }uaua�aedat� 6ui��luaaad tao s a inr i f *K46-1 mik 1 ENGINEERING& SURVEYING, LLC. 690 NW PEACOCK BLVD, SUITE N8 PORT ST. LUCIE, FL 34986 PHONE: (772) 879-0477 FBPE C.OA. # 32222 REVISIONS: BY: I DATE: I COMMENT: W 0 U) Z W o _j Z a a w D 0 0 ® 0 Z Z J Z W = I..L. z 00 U D oQ Lu ❑ C) F C) O F LL W (06/) /! W CC) F .�CENS NO 74637 STATE OF ' W OR 1-0, 'FORD URE r k'.. 01O n0,,.` +q Y 1 RENJIEVYh FOR ul � DARREN GUETTLER, PE A ESS Y U ACC SOR E SE CODE COMPLIANCE FLORIDA LICENSE No. 74637 Sf. �l)CIE COUNTY 07/07/21 OFFI AR 0 ICE P BOCCOU( // O r r r 340 RSONS ® ' 31-0" 11-01, EXISTING BUILDING n (T6 hEMAIN) u I� 11-011 51-01, SCALE: 1/811= 11-01, All Sub -contractors are Responsible for verifying all changes to these plans prior to starting their phase of construction OJECT No.: 21-1009-KMA AWN BY: ELK ECKED BY: EV TE 7/812021 D I.DtSLAMORADA DISTILLERY SHEET TITLE: EXISTING YNOW WHAT'S BELO SITE ALWAYS CALL811 CONDITIONS BEFORE YOU DIC III it"roc. irs. ns ma rew. S' UMBER: www.callsunshine.com Es.10 z-41 122623 aurs:RE [7b1. j - [^"o).iy�o ,H `°°".Inca 12" 3,000 P.S.I. CONCRETE SLAB AT 28 DAYS WITH I CONCRETE SLAB SAW -CUT 05 / 6x6, W2.9, W2.9 WELDED WIRE FABRIC _ LIMITS (TYP.) TREATED AGAINST TERMITE NFES AT ON. CLEAN FILL EXISTING CONCRETE - tFLOOR SLAB (NOTE 01). CO 03 r S.10 o°d�°o��00000�0 06 � (� - O°G°O°O°G°0°O O°C°0°O°O°G°U S.10 O O-0 O C G O O Q O 0 0 fl GAO O OO ,O O O� G O O o°o°0eG°c°0°o OCC°o°o�0°0°0 / 1 O, o 0 0 0 o d o 0 o c G o _ C 0(, 000 CCO 0C 0:.00000000000 O f----F' o0000C,.. 000G CO 100G 0, 00. 000000 G O O ..0 O. n. 05 \.. G0°oo0 oc'G°G°o°o°o"c°o°o°°°c; o 0 0 0 0 0 O b 0 0 0 O0 - 0 0-0 0 C 0 0 0 0 0 0 0 U O - I 1 o.,o ° c c o o0c d o o" S.1 O CMF IF I +' �oocn o4- ooaoa 0 0 o G o 0 0 0 0 0 0'0 c o - 20 0 0 0 0 O O 0 0 0 O o O [6J7s1' [5926. [4902] 0 0 0 O O G d O o 0 0 0 Oy 0000000.00000 o d OG G0000 O O O 2r-11 ooG000000000000�0o 0o 00 O C O00o G. [6566' 1 CO00000000000000000000000C 0 pO0 000000000 0 0000000000° 000000 000000 0000°C 00000 CO-��� O O D 0 0 0°0 O° O o 0 0 0 C.1D 81-311. O O O G G O O o O C 0 0 0 0 0 0 o d o 0 0° o G if 6 vi 111.311 GAO°°° ° o° o° o( 0 0 0 EXISTING CONCRETE o0o0o0c Imo o°Oa FLOOR SLAB (NOTE 01) -I (C-) Cc) o o�O000G � ' �°.p°o° •�. 04 15OBBL TANK „ -L"' 03 1 -0 5 0 ooOGoo c°0000e S.10 SCALE: 1/4"= 1'-0" -- FOUNDATION PLAN (TYP.) 3 [76i T 01 150BBL TANK ix w]w`sx 1a4. SCALE: `nits ELEVATION THE ATTACHED PLANS HAVE BEEN DESIGNED FOR AND ARE iN GENERAL NOTES COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE (WIND); (FBC) EXISTING BUILDING 7th EDITION; AND (FBC) BUILDING 7th EDITION FOR THIS 1. PLAN NOTES PROJECT WHICH INCLUDE. AND MAY NOT BE LIMITED TO; Surface Roughness: C A) THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD Site Exposure Category: D PRIOR TO FABRICATION AND START OF CONSTRUCTION AND TO PROTECT AND MAINTAIN ALL THE CONSTRUCTION AND ITS CONTENTS, Wind Zone (4) B REFER TO THE ARCHITECTURAL DRAWINGS. FOR ALL DIMENSIONS NOT THE 2020 BUILDING CODE FINAL FIGURE "A" (FIGURE 1609A ULTIMATE DESIGN WIND SPEEDS INDICATED. ANY DIMENSIONAL DISCREPANCY FOUND ON THE STRUCTURAL USING A MAXIMUM (Vult) WIND VELOCITY OF 160 MPH. ENGINEERING DRAWINGS SHALL BE CONTROLLED BY THE DIMENSIONS INDICATED ON THE DESIGN IS SITE SPECIFIC AND NOT VALID WITHOUT ARCHITECTURAL DRAWINGS. FURTHER VERIFY WITH ARCHITECT. THE AUTHORIZED SIGNATURE AND SEAL OF A REGISTERED PROFESSIONAL ENGINEER. THESE NOTES ARE PART OF THE C FOR MOUNTING AND SECURING MECHANICAL EQUIPMENT, REFER TO THE CONSTRUCTION DOCUMENTS AND MUST BE READ AND ADHERED TO BY ALL APPLICABLE SUBS. USE FIGURED DIMENSIONS ONLY. MANUFACTURE'S INSTRUCTIONS UNLESS INDICATED ELSEWHERE IN THE IF A DISCREPANCY OCCURS DO NOT SCALE THE DRAWING, CONTACT CONSTRUCTION DOCUMENTS. THE ENGINEER OF RECORD. D) THE GENERAL CONTRACTOR SHALL, AT ALL TIMES, MAINTAIN AT THE JOB- THESE DOCUMENTS TO WHICH I HAVE AFFIXED MY SIGNATURE AND SEAL WERE PREPARED BY ME AND/OR UNDER MY DIRECT SITE A CURRENT APPROVED SET OF SHOP DRAWINGS.. SUPERVISION. THESE DOCUMENTS ARE INSTRUMENTS OF USE AND ARE PROTECTED BY THE COPYRIGHT LAW OF THE U.S. E) REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING THEY MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT DRAWINGS FOR OPENINGS, SLEEVES, ETC. NOT SHOWN ON THE STRUCTURAL WRITTEN PERMISSION OF THE ARCHITECT/ENGINEER.THE DRAWINGS. CERTIFICATION CONTAINED HEREIN APPLIES ONLY TO THOSE STRUCTURAL ELEMENTS COVERED UNDER THE 2020 FLORIDA BUILDING CODE AS THEY PERTAIN TO THE EXISTING FOUNDATION 2. FOUNDATION NOTES - ANCHOR SYSTEM OF THE STORAGE TANKS. THE STORAGE TANKS ARE DESIGNED AND CERTIFIED BY THE TANK MANFACTURERS. A) FOOTINGS HAVE BEEN DESIGNED FOR A MINIMUM BEARING VALUE OF 2000 P.S.F. B) CONTRACTOR IS RESPONSIBLE FOR VERIFYING SITE CONDITIONS PRIOR TO INSTALLATION OF FOUNDATION. THE ENGINEER SHALL BE NOTIFIED IF SITE CONDITIONS DO NOT PROVIDE AN ADEQUATE BEARING PRESSURE VALUE OF 2000 P.S.F. 3. CONCRETE NOTES A) STRUCTURAL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 AND SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH IN 28 DAYS OF 3000 PSI. UNLESS NOTED OTHERWISE. B) CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 41NCHES PLUS OR MINUS ONE INCH. C) ALL REINFORCING SHALL CONFORM TO ASTM 615 FOR GRADE 60 STEEL. D) CONSTRUCTION JOINTS DESIGN AND LOCATION SHALL CONFORM STRICTLY TO THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. ANY CONSTRUCTION OR CONTROL DESIRED OR PREFERRED BY THE CONTRACTOR SHALL BE APPROVED BY THE ENGINEER PRIOR TO CONSTRUCTION OF THOSE AREAS INVOLVED. E) CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURE'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS, SUCH AS PIPE SLEEVES ANCHOR BOLTS, ETC. PRIOR TO PLACING CONCRETE. F) REINFORCEMENT FOR STRIP FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 18 INCH LAP (MIN.). PROVIDE CORNER BARS. ' EXISTING F OUNDA11ON AND SLAB NOTE 01: 6" 3,000 P.S.I. CONCRETE SLAB AT 28 DAYS WITH 6x6, W2.9, W2.9 WELDED WIRE FABRIC ON 10 MIL. POLYELENE VAPOR BARRIER OVER CLEAN FILL TREATED AGAINST TERMITE INFESTATION. PROVIDING FOR A MINIMUM BEARING VALUE OF �1Zac2a�aCd .Seee .�c�t�tece M LAP SPLICE LENGTHS I 200 Avenue Road Combridge, ON.. P1R 8H5 Tel 620-7bOO Fax. 6,21 4995 C00p00 �U°O°°U°°O°O°O°CO°°O o c°o°o°c°oc c c c c o0 0 Ooc°o°oouo°o° ca°o°o°a°o°aQa BAR SPACING 6" OR GREATER SPACING LESS THAN 6" SIZE 'TOP• BAR OTHER BAR "TOP" BAR OTHER BAR 5 24" 18" 18" 18, °o0 0C°o°off SHALL ... , :. l , y- y�I O�UpO�O�aC°IO�U UDU�OpUCOGC�04 _.<x ., ..�- GRADE 60 REINFORCEMENT. MINIMUM LENGTHS SHOWN L BE Z• �) ' s,j r =' I. USED UNLESS OTHERWISE NOTED ON THE PLANS. :7421 I 1 03 /!_ y - �} O°o°O°C°Coo°c''ID°o°P°P°O°94'O e • • • • • 1 1 • "' • 1 • •. ..:. / 5.10 .3¢. Isu]ej 1 4x1 O C O ° ° O ({ O O U O ° U° �• ¢ee--- -/ t T p O U V U U U O O U O UOUI [4 ] + -- -- o°o°c°°°o°O o°aoa°OCoO°O°o5y - ° ° ° ° ° ° ° ° ° ° ° ° SET Design Information Concrete o 0 0 0 5 0. n o 0 0 0 0 0 0"� �] (TYP.) l o a o o c o o aoo°o°U,00a I c�aoo°oQcoaoo °o°o o- o c o ' I � SET Allowable Tension Loads for Threaded Rod Anchors in Normal -Weight Concrete {continued on next page} O°° °° 111 O°O°O°: EXISTING CONCRETE 7G�1 \\ JI �� / / �/ \\ /i i` / / I� •. FLOORSLAB (NOTE 01) y ; I I v y yi L:I IS,zI � , 11a 71 i as' TI=Tf1=rI CITI'1 17, r1`T = - 1=1 I I El I II R 5' _ I I I I -1 1=1 1=1 I -1 I-1 = _ _ =1 1= = _ _ = -1I -1 -1 I-1 1= L_I -II1 I -I -1 I rF, i i , l 11-I - - - --III J I I -III -III -III -I I I - III III III I 02 150BBL TANK PLAN EMBEDMENTLENGTHS BAR SIZE STRAIGHT BARS "TOP"BAR OTHER BAR HOOKED BARS 5 2-4- 24" g 1i4 2% 7 1,9w 485 475 1,900 475 U) (44) (60 (176) (8,5) (22) (2,1) (8.5) - (2.1) 0 h 31h 5 % 14 10,200 119 2,550 10.280 97 21570 2,105 C (9.5) 18111 (133) (356) (45.4) (0 5) (1131 (45.7) (0.4) 01A) 4Va 6i% 18 10,613 84 Z655 10,613 (114) (171) (45T) (47.2) (0 1 (11A (472) - (116) Q N mm, 7 LL`m'iMs.', 9 RN4 Y)p7I' 7,216 11 32.1) (52) r} W`y117,7[b54 i 629 (2.8) i 4 Q 2 �Z 33'a ,... 10 6,780 315 1,695 6,780 _ 1,695 03 % f. 5 7Va 20 26,700 1,121 6,690 32,200 964 8,050 5,875 ms " A (15.0) (127) (191) (508) (11818) (5A) .0 043.2) (0) MIA (2F 11 (133] 5.10 Me 107/6 28Y4 (183) (276) (130) SOLIDTHREADED BAR r , (TYP.) \ I CONCRETE SLAB SAW -CUT 12" 3,000 P.S.I. CONCRETE SLAB AT 28 DAYS WITH g" FROM EACH CORNER \I 1 6x6, W2.9, W2.9 WELDED WIRE FABRIC LIMITS (TYP.) AND 16" ON CENTER ON 10 MIL. POLYELENE VAPOR BARRIER OVER CLEAN FILL I r IZ-7 TREATED AGAINST TERMITE INFESTATION. :FOR BALANCE (TYP.) THREAD) M27 ' 81, EXISTING CONCRETE rt tl [2031 FLOOR SLAB (NOTE 01) 6x6, W2.9 x W2.9 (W.W.M.) 1- EXISTING CONCRETE ., FLOOR SLAB (NOTE 01) _ M27 METRIC HREAD Finished Floor CLEAR el. +0'-0" -------------- -- P o • • • • • 4 ''- NO WELD - - • • • • • • - - T [19: Finished Floor - - - _ _ 2sa. „ 1,111 1III�IIIII�IIIIL� III I_ -III„III 114��1111111111�11111 I1,1=11 W [ 1 el. (-) 0 10 t _ . _ - n J - LOOSE FOOT U PADS. 1 FOOT DETAIL: ALL MATERIALFinished Floor Ak (12)#5 BARS EACH WAY BOTTOM 304 OR T303MX al. (-) 1 -1211 - - VISQUEEN VAPOR BARRIER 03 150BBL TANK LEG 06 SECTION Mac�a�aed .5&d ZeWe ed SCALE: nts 200 Avenue RoadCarnbridae, ON. NIR BH5 TeL 620-0500 Fox. -621 4995 05 150BBL TANK (IYF'.) Mac2)aaaed .5reee .Cemered FOUNDATION SECTION 200 Avenue: Rood Cambridge, ON. E LF-Ib lei 620-CDOC Fax 621 u995 SCALE: nts 5'-0„ SCALE: 1/4"= 1'-0" 1 CLEAR SCALE: nts 07 ANCHORS 4,535 3,63(1 (20 �j (161) O 12,660 10,120 (56 3) (45 0) ELCON' ENGINEERING & SURVEYING, LLC. 590 NW PEACOCK BLVD, SUITE #8 PORT ST. LUCIE, FL 349M PHONE: 0`72) 879-0477 FBPE C.OA # 32222 REVISIONS: BY: I DATE: I COMMENT: 010-1 z LL1 C/) 0 0 (�✓ W I.i.- f n V 0 O 7 Z U) J CODp��y O ee' 120 1Q L1 J T- ♦'�.�r�' l O z ® Cj / /•� J m W_ 0 O O U O Cl)z W c U IJ _J W o of O G //'•��// I F- CD [0 LL 1 .L w CD V C5 w co co GU E .. 0a `. G . IV`,, k NO. 74637 o = _ U : F : STATE OF O -. to S7ON ..L DARREN GUETTLER,PE FLORIDA LICENSE No. 74637 07/07/21 PROJECT No.: 21-1009-KMA DRAWN BY: ELK CHECKED BY: DG DATE: 7/7/2021 CAD I.DISLAMORADA DISTILLERY SHEET TITLE: SCALE: nts _ STRUCTURAL All Sub -contractors are Responsible for verifying all changes to these plans prior to starting their phase of construction KNOW WHAT°S BELOW TANK ALWAYS CALL811 FOUNDATION BEFORE YOU DIG ir. fecL lrs u".. irom" iew. SHEET NUMBER: www.c d1sunshine.com F11!. *� S.10