Loading...
HomeMy WebLinkAboutEVALUATION REPORTa CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 1 of 11 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 7TH EDITION (2020) Manufacturer: ATLAS ROOFING CORPORATION Issued August 26, 2020 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 (770) 612-6267 Manufacturing Plants: Hampton, GA Meridian, MS Dangerfield, TX Ardmore, OK Franklin, OH Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Edition: Florida Building Code, 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ) Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain PRODUCT DESCRIPTION Legend (Ardmore) ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. GlassMaster® 30 (Ardmore & Hampton) ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Tough-Master® 20 (Ardmore & Hampton) ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Pro-Cut® Hip & Ridge (Ardmore & Hampton) ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle with a dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Pro-Cut® Starter Strip (Hampton) ASTM D 3161, Class F fiberglass reinforced, starter asphalt shingle with a dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. ProLAM™ Architectural (Hampton, Franklin & Meridian) ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated architectural asphalt shingle with a dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Pinnacle® Pristine, Pinnacle® Pristine Lifetime w/Scotchgard (Dangerfield, Hampton, Franklin & Meridian) ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated architectural asphalt shingle with two, dashed, thermally-activated, self-sealing sealant stripes that complies with ASTM D 3462. StormMaster® Shake (Dangerfield) ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated architectural modified asphalt shingle with two, dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. A CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 2 of 11 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. ATLAS ROOFING CORPORATION Asphalt Shingles StormMaster® Slate (Ardmore) ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated architectural modified asphalt shingle with two, dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) ATL-079-02-01 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-083-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-086-02-01 Rev 1 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-104-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-106-02-01 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-106-02-01 Rev 1 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-107-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-107-02-01.1 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-109-02-01 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-116-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-118-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-119-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-123-02-01 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-125-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-127-02-01 Rev 1 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-132-02-01 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-133-02-01 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-135-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-136-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-137-02-01 Rev 1 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-138-02-01 Rev 1 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-143-02-01 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-144-02-01 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-151-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-162-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-167-02-01 ASTM D 3161 2016 PRI Construction Materials Technologies (TST5878) ATL-168-02-01 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-169-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-170-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-171-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-172-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-174-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-179-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-184-02-01 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-185-02-01 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-186-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-187-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-220-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-220-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-220-02-03 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-220-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-221-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-221-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-221-02-03 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-221-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-222-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-222-02-02 TAS 100 1995 A CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 3 of 11 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. ATLAS ROOFING CORPORATION Asphalt Shingles Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) ATL-222-02-03 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-222-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-223-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-223-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-223-02-03 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-223-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-224-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-225-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-225-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-225-02-03 ASTM D 3161 TAS 107 2016 2020 PRI Construction Materials Technologies (TST5878) ATL-225-02-04 ASTM D 7158 2019 CREEK Technical Services LLC (ANE11669) ATL13002.7 Calculations 2018 A CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 4 of 11 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. ATLAS ROOFING CORPORATION Asphalt Shingles INSTALLATION Legend Basic Wind Speed (Vult): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 5-inch exposure in accordance with RAS 115 and manufacturer’s published installation instructions. Shingles shall be attached using “6 Nail Pattern” detailed below. Installation (Non-HVHZ): Installed with 5-inch exposure in accordance with FBC requirements and manufacturer’s published installation instructions. Shingles shall be attached using either “4 Nail Pattern” or “6 Nail Pattern” detailed below. Figure 1. Legend 4 Nail Pattern (Non-HVHZ only) Figure 2. Legend 6 Nail Pattern A CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 5 of 11 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. ATLAS ROOFING CORPORATION Asphalt Shingles GlassMaster® 30 & Tough-Master® 20 Basic Wind Speed (Vult): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 5-inch exposure in accordance with RAS 115 and manufacturer’s published installation instructions. Shingles shall be attached using “6 Nail Pattern” detailed below. Installation (Non-HVHZ): Installed with 5-inch exposure in accordance with FBC requirements and manufacturer’s published installation instructions. Shingles shall be attached using either “4 Nail Pattern” or “6 Nail Pattern” detailed below. Figure 3. GlassMaster® 30 & Tough-Master® 20 4 Nail Pattern (Non-HVHZ only) Figure 4. GlassMaster® 30 & Tough-Master® 20 6 Nail Pattern A CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 6 of 11 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. ATLAS ROOFING CORPORATION Asphalt Shingles ProLAM™ Architectural Basic Wind Speed (Vult): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 6 in. exposure in accordance with RAS 115 and manufacturer’s published installation instructions. Shingles shall be attached using “6 Nail Pattern” detailed below. Installation (Non-HVHZ): Installed with 6 in. exposure in accordance with FBC requirements and manufacturer’s published installation instructions. Shingles shall be attached using either “4 Nail Pattern” or “6 Nail Pattern” detailed below. Figure 5. ProLAM™ Architectural Shingle 4 Nail Pattern (non-HVHZ only) Figure 6. Pro-LAM™ Architectural Shingle 6 Nail Pattern A CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 7 of 11 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. ATLAS ROOFING CORPORATION Asphalt Shingles Pinnacle® Pristine & StormMaster® Shake Basic Wind Speed (Vult): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 6 in. exposure in accordance with RAS 115 and manufacturer’s published installation instructions. Shingles shall be attached using “6 Nail Pattern” detailed below. Installation (Non-HVHZ): Installed with 6 in. exposure in accordance with FBC requirements and manufacturer’s published installation instructions. Shingles shall be attached using either “4 Nail Pattern” or “6 Nail Pattern” detailed below. Figure 7. Pinnacle® Pristine and StormMaster® Shake 4 Nail Pattern (Non-HVHZ only) Figure 8. Pinnacle® Pristine and StormMaster® Shake 6 Nail Pattern A CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 8 of 11 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. ATLAS ROOFING CORPORATION Asphalt Shingles StormMaster® Slate Basic Wind Speed (Vult): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 8.5 in. exposure in accordance with RAS 115 and manufacturer’s published installation instructions. Shingles shall be attached using “6 Nail Pattern” detailed below. Installation (Non-HVHZ): Installed with 8.5 in. exposure in accordance with FBC requirements and manufacturer’s published installation instructions. Shingles shall be attached using either “4 Nail Pattern” or “6 Nail Pattern” detailed below. Figure 9. StormMaster® Slate 4 Nail Pattern Figure 10. StormMaster® Slate 6 Nail Pattern A CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 9 of 11 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. ATLAS ROOFING CORPORATION Asphalt Shingles Pro-Cut® Starter Strip Basic Wind Speed (Vult): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed in accordance with RAS 115 and manufacturer’s published installation instructions. Shingles shall be attached as shown below. Installation (Non-HVHZ): Installed in accordance with FBC requirements and manufacturer’s published installation instructions. Shingles shall be attached as shown below. Figure 11. Pro-Cut® Starter Strip A CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 10 of 11 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. ATLAS ROOFING CORPORATION Asphalt Shingles Pro-Cut® Hip & Ridge Basic Wind Speed (Vult): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Installation (HVHZ and non-HVHZ): Installed with 5-5/8 inch exposure in accordance with RAS 115 (HVHZ only) and manufacturer’s published installation instructions. The direction of the exposed end shall be away from the prevailing wind. Figure 12. Pro-Cut® Hip & Ridge A CREEK Technical Services, LLC ATL13002.9 FL 16305-R9 Page 11 of 11 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION Asphalt Shingles LIMITATIONS 1)Fire Classification is not within the scope of this evaluation. 2)The roof deck and the roof deck attachment information are provided based on testing. FBC requirements for the rational design of the roof deck, including the attachment, are not within the scope of this evaluation. 3)The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4)Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less. 5)Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6)Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7)Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8)All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT