HomeMy WebLinkAboutEVALUATION REPORT ROOFING UNDERLAYMENTS CREEK
Technical Services, LLC
ATL16001.4 FL21350-R4 Page 1 of 3 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020)
Manufacturer: ATLAS ROOFING CORPORATION Issued January 10, 2021
2000 Riveredge Parkway, Suite 800
Atlanta, GA 30328
(770) 612-6267
www.atlasroofing.com
Manufacturing Locations: Hebei, China
Quality Assurance: Intertek Testing Services NA Inc. (QUA1673)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
REFERENCES
Entity Report No. Standard Year
Intertek Testing Services NA, Inc. (EVL11327) CCRR-1038 AC 188 2012
Intertek Testing Services NA, Inc. (EVL11327) CCRR-1038 ASTM D 226 2009
Intertek Testing Services NA Ltd. (TST1509) 141128020SHJ-BP-1 AC 188 2012
ASTM D 4869 2016
PRI Construction Materials Technologies (TST5878) ATL-238-020-1 TAS 117(B) 2020
PRI Construction Materials Technologies (TST5878) 117T0023 ASTM D 4533
ASTM D 5035
2015
2011(2019)
PRI Construction Materials Technologies (TST5878) 117T0025 ASTM D 4533
ASTM D 5035
2015
2011(2019)
PRODUCT DESCRIPTION
Summit 60 A mechanically attached, synthetic underlayment used an alternative to ASTM D 226,
Type II roofing underlayments with a minimum tear strength per ASTM D 4533 of 15
pounds, a minimum tensile strength per ASTM D 5035 of 20 pounds/inch, and meets
liquid water transmission test of Section 8.6 of ASTM D 4 869. The roll is available in 48-
inch wide x 250-ft long format and weighs approximately 23 lbs.
Summit 180 A mechanically attached, synthetic underlayment used an alternative to ASTM D 226,
Type II roofing underlayments with a minimum tear strength per ASTM D 4533 of 15
pounds, a minimum tensile strength per ASTM D 5035 of 20 pounds/inch, and meets
liquid water transmission test of Section 8.6 of ASTM D 4869 . The roll is available in 48-
inch wide x 250-ft long format and weighs approximately 30 lbs.
A CREEK
Technical Services, LLC
ATL16001.4 FL21350-R4 Page 2 of 3 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
ATLAS ROOFING CORPORATION
Summit Underlayments
APPLICATION INSTRUCTIONS
Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing
construction. Sheathing shall be installed in accordance with FBC requirements. Roof
decks shall have no more than 1/8” gap at abutting joints.
Attachment method: Underlayment shall be attached in accordance with the FBC and manufacturer’s
installation instructions. The underlayment is installed starting at the eave, with the
length of the roll parallel to the eave with the printed side facing up. A ll side laps shall be
installed to shed water from the deck. End laps shall be staggered between courses in
accordance with the manufacturer’s application instructions. Minimum application
temperature shall be 50°F.
1507.1.1 Exception: Equivalency of 1-inch diameter plastic cap nails where the ultimate
design wind speed, Vult, equals or exceeds 170mph has been demonstrated for Summit
60 and Summit 180 by increasing the attachment density by a factor of 3 .
Allowable roof coverings: Mechanically fastened roof coverings as prescribed in FBC Section 1507.1.1 and Table
1507.1.1.1 shall be permitted.
LIMITATIONS
1) This evaluation report is not for use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance is not within the scope of this evaluation.
4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer’s published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Roof slope limitations shall be in accordance with FBC requirements.
7) Contact the manufacturer when installing at temperatures below the minimum application temperature.
8) The underlayment may be used as described in other current FBC product approval documents.
9) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
A CREEK
Technical Services, LLC
ATL16001.4 FL21350-R4 Page 3 of 3 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
ATLAS ROOFING CORPORATION
Summit Underlayments
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT