WIND PRESSURE CHART
BUILDINGS PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COAIPOH£NTS & CLADDING (P.S.F.) FOR ASGE 7 16 - PEAK ROOF HEIGHT LESS THAN OR EQUAL TO 60 FEET qt BASIC WIND SPEED - 170 mph RISK CATEGORY Il BUILDINGS ` RESIDENTIAL, APARTMENT BUILDINGS& COMMERCIAL BUILDINGS(RETAIL, WHOLESALE) PEAK I-LESS THAN 7-9' L--GREATER OR EQUAL THAN 7'-9"AND 0-GREATER OR EQUAL THAN 12'-5' LESS THAN 12'-3" ROOF HEIGHT POSITIVE NEGATIVE POSITIVE NfG41IVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATET A.S.D. ULTIMATE A.S.O. ULTIMATE I A.S.D. ULTIMATE A.S.O. ULTIMATE A.S.D. * INDICATED DESIGN WIND PRESSURES 0'- 15' 76.4 45.8 102.4 1 61.4 7J.0 43.6 95.5 57.J 68.5 41.1 86.4 51.8 CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS > 15'-20' 80.4 48.2 107.6 64.6 76.8 45.1 100.4 60.2 72.0 43.2 90.6 54.5 AND FOR ALL ROOF , SLOPES. >20'-25' 63.6 50.2 111.9 67.1 79.8 47.9 104.4 .62.6 74.8 44.9 94.4 56.6 aka L=STORM PANEL LENGTH, i 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77.3 46.4 974 58.4 ACCORDION SHUTTER BIADE LENGTH OR BANANA >30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 SHUTTER HEIGHT. >40'-50' 94.3 56.6 126.2 76.7 90.0 54.0 1177 70.6 84.4 50.6 106.5 63.9 arJKAK PRODUCTS WHICH BEAR A 97.3 58.4 130.3 78.2 92.9 55.7 121.5 72.9 87.2 523 1 p9,g 65.9 M/AMl-DADS COUNTY OR A STATE OF FLORIDA APPROVAL BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR GOAIPONENTS CLADDING (P.S.F.) FOR ASCE 7-16 - PEAK ROOF HEIGHT GREATER THAN 60 FEETdiY BASIC WIND SPEED - 170 mph RISK CATEGORY II BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS& COMMERCIAL BUILDINGS(RETAIL, WHOLESALE) PEPOf (f, Ito E400, PEAK L••LESS THAN 12-J" I-GREATER OR EQUAL THAN 12'-3' ROOF POSITIVE NEGATIVE POSITIVE NEGATIVE _ HEIGHT gyp] py� p'�p''y (h) ULTIMATE A.S.D. ULT/MAZE A.S.O. ULT/MATE A.S.O. ULTIMATE A.S.O. REVIMED FOR >60'-70' 91.5 54.9 1677 100.6 84.3 50.6 148.4 89.0 CODE ca�+otu��:9��^�,A`��l��nNe-�(• E BUILDING SCHEMATIC >'8o'-9o' 95.6 57.4 175.2 105.1 88.0 52.8 755.0 93.0 ST. LUCIE COUN d B >90'- 100' 973 58.4 178.4 1O74 89.7 5J.8 157.9 94.7 v p®C > 100'- 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 97.8 IIIII IIINN7/lli�„ > 120'- 140' 103.2 67.9 189.2 113.5 95.1 57.1 167.4 100.4 �.P�.\ER. ..... > 140'- 160' 105.6 63.4 193.6 116.2 97.3 58.4 171.J 102.8 ;s\; �,\�ENSF '••p�% > 160'- 180' 1078 .,64r7 197.6 1.18.6;,L 99.3 59.6 174.9 104.9 > 180'-200' 109.8 65.9 201.J 120.E 101.1 60.7 178.1 106.9 = No.44167 >200'-250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 =•y1;[ * t*' >250'-JOO' 117.8 70.1 216.0 129.6 108.5 65.1 191.1 114.7 %A STATE OF ;•��` >J00'-J50' 121.0 72.6 221.9 133.1 111.5 66.9 196.3 7178 9 FILE CulpY > 50'-4aO' 723.9 74.3 2271 136.3 114.1 6B.5 200.9 120.5 3 �\ >400'-450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 12J.1 -s0D' 128.8 77.3 236.1 141.7 118.E 71.2 208.9 125.3 1.)ruts Camino SIGNED AND SEALED WIND LOAD CHART,PREPARED BY THIS ENGINEER,BASED ON ASCE 7-16,FOR A BASIC WIND SPEED Of 170 MPH,AND 2020(7th EDITION)FLORIDA BUILDING CODE-BROWARD,PALM BFACH,-MAR77N,ST.LUCIE&INDNN RIVER COUNTIES APPLICABLE'RISK CATEGORY BUILDING&EXPOSURES,15 COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 02020 DLTErn,INC ASCE 7-16/ WIND PRESSURE CHART M•F 1 2.)'THIS WIND LOAD CHART MUST BE SIGNED,SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT. STORM PANELS,ACCORDION&BAHAMA SHUTTERS . DRAWN BY ry RISK CAT. lI BLDlS 06/23/2020 WIND PRESSURES ARE ULTIMATE AND A.S.D.PRESSURES. I L E C O 3.)COHMCTOR OR PERMIT HOLDER TO BE RESPONSIBLE TOR THE SELECTION OF DESIGN WIND PRESSURE S45ED ON THIS GENERIC WIND LOAD CHART. I I N C. DATE WIND PRESSURE CHART I.)THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 7TLLA TE`IZJI h 4.VRVERINO COMPANY 6]A6 N.W.J6N.SL SM1.Jc;V/RCMM GRDLA'£iL JJI66 BASIC WIND SPEED= l70 mph 20-117 5.)DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE IND/GATED ON A SEPARATE DOCUMENT PREPARED BY Pnon.:(JwJen-1=•FB:(J(bDIMMI6JI EXPOSURE D,Kd=O.BB THE CONTRACTOR OR PERMIT HOLDER(.B••SPREADSHEET,OPENING SCHEDULE/TAKE Off SHEET,ETC.). CA-0006719 �,x. �� ua ay N erssvna 'DRAWING N. WALTER A TXUT Jr.P.E. q0 n-ror /rynn FLORIDA Uc.f 44167 SHEET i OF I