HomeMy WebLinkAboutLetter; Prima Vista - ADA Compliance Improvement ProjectaG CULPEPPER & TERPENING INC CONSULTING ENGINEERS I LAND SURVEYORS C&T Project No.: 20-142 File: Correspondence Sender's Email: ebrown@ct-eng.com March 22, 2021 VIA: EMAIL DELIVERY Mr. Andrew Manero St Lucie County 2300 Virginia Ave Fort Pierce FL 34982 RE: Prima Vista — ADA Compliance Improvement Project Permit Comment Responses Mr. Manero, Culpepper & Terpening, Inc. is pleased to present our responses to your comments provide for the Prima Vista ADA Compliance Improvement Project Permit submittal: Plans Examiner Review: 1) PER ZONING, PARKING WILL BE REDESIGNED, RE -SUBMIT TO BUILDING DEPT FOR REVIEW WHEN UPDATED PLANS ARE SUBMITTED. a. Response: Please see my response to the zoning comment below. As our current design solves the grading issue of the accessible parking spots while avoiding the need to completely redesign the drainage patterns of the parking lot, we may not need to redesign the parking space layout or resubmit plans. 2) REVISE DESCRIPTION OF WORK IN THE APPLICATION, ADA RAMPS ARE SHOWN AS CONCRETE, NOT ASPHALT. ([A]107.2.1) a. Response: The description of work in the application was incorrect and will be corrected to "concrete" for the ADA Ramps. ZONING REVIEW: CHECK WITH LINDA IF LOCATION OK. 2/2/21 DISCUSSED WITH LINDA P. SHE ADVISES ONLY 1 ADA PARKING TO RELOCATE TO HAVE AT LEAST 1 ADA PARKING AT THE SOUTH SIDE OF THE BUILDING PER LINDA PENDARVIS, PLANNING MANAGER. PLEASE REVISE THE PLAN TO RELOCATE ONE ADA PARKING FROM THE SOUTH SIDE AND LEAVE ONE ADA AT EXISTING LOCATION. PLEASE PROVIDE CORRECTED PLANS. *NO ENGINEERING REQUIRED UNLESS BUILDING DEP. WISHES THEM TO ASSIST AND REVIEW. a. Response: The objective of this project is to ensure that the accessible parking spaces meets ADA grading requirements. After reviewing the slopes of the parking lot, we discovered that the existing accessible parking spots were not meeting ADA grading requirements due to the drainage inlet located south of the parking spots. To correct the grading of the existing accessible parking spots would create a domino effect and require a complete redesign of the drainage patterns and drainage structures within 20.142 - Permit - Comment Response.docx ic; CULPEPPER & TERPENING INC CONSULTING ENGINEERS I LAND SURVEYORS the parking lot. As a solution, we decided to move the ADA parking spaces to the west side of the building where the existing pavement already meets the ADA grading requirements. Also, the location of the proposed accessible parking spots is only 50' away from the existing location which is still relatively close. We hope our engineering judgement will be considered in approving the permit with the current layout. We trust that this submittal meets with your expectations. As always, should you have any questions, please do not hesitate to contact me at (772) 464-3537 or via the email address referenced above. Sincerely, CULPEPPER & TERPENING, INC. Eliot Brown, P.E. Project Engineer Professional Engineer No. 82232 . E �� N0.a ENS ,�G F.ly ?0z•• STATE OF ,�•., �' t�`�•'• � OR10P..•�''��?N -f�li�tirtr� . 21 20.142 - Permit - Comment Response.docx