HomeMy WebLinkAboutAPPROVED, Guz WP Letter(1) Advanced Architecture & Planning LLC Architect & Planning 4929 S. Indian River Drive Ft. Pierce, FL 34982 (772)631-5709 Applied Wind Pressures Certification: August 31, 2021 Bill Laprade Glass Professionals, Stuart, Florida Cell: 772-745-3459 Project: Guz Residence 10044 S Ocean Dr #502 Jensen Beach, FL 34957 Dear Mr. Laprade: For the above address, the replaced three impact rated sliding glass doors by CGI, SGD-150. The minimum required wind pressures below are based on the FBC 2020 wind load calculations. The applied wind pressures are as follows per the proposed replacement glazed units for Exposure D, 50 feet in height: (Respective NOA 20-0729.06) Entry Door Wind Zone: Applied Wind Pressure: (1) 107.5”x80” SGD 5 +49.8/ -62.4 psf; (1) 71”x80” SGD 4 +50.7/ -55.2 psf; In reviewing respective NOA for the above units, the allowable respective design pressures exceeds these respective applied pressures and as such is acceptable to this office If you have any questions, please contact me at any time. Thank you, Raymond Chladny, B.arch.Sc., M.arch, AIA, NCARB, Lic.#: AR-0017475