Loading...
HomeMy WebLinkAboutInstallation Instructions Model 1101 V SeriesOLIVER TECHNOLOGIES, INC. INSTALLATION INSTRUCTIONS FOR FLORIDA MODEL 1101 "V" SERIES ALL STEEL FOUNDATION SYSTEM PAN & CONCRETE (revision 5/18) PATENT# 6634150 & OTHER PATENT PENDING a{' =V E ek By.SEANSWONGERof6.32Wxp W31118 REVIEWED D By SEANSWONGERat 6:33 am, MI/l8 Y Y � g�g991f/:8r ! f 0 �2i ce 0 ti'i a STATE OF dA � .4 o iZ s* P u'ttil ,�+ ay ro °6a�/►/99ts�° Aug 24, 2018 FILE. COPY ,y, 467 Swan Ave • Hohenwald, TN 39462 • (800) 284-7437 • www.olivertechnologies.com • f-ax tyj is rvn ess a + OLIVER TECHNOLOGIES, INC. FLORIDA INSTALLATION INSTRUCTIONS FORTHE MODEL 1101 "V" SERIES ALL STEEL FOUNDATION SYSTEM MODEL 11 b'1" V" (Steps 1-1 "4) LONGITUDINAL ONLY: Follow Steps 1-9 LATERAL ONLY: Follow Steps 1-3 and Steps 10-14 ENGINEERS STAMP FOR CONCRETE APPLICATIONS- Follow Steps 15-1 a ENGINEERS STAMP 1. SPECIAL CIRCUMSTANCES: If the following conditions occur - STOKCantaet Oliver Technologies at 1-800-284-7437: a) Pier height exceeds 48" c) Roof eaves exceed 16" e) Location is within 1500 feet of coast b) length of home exceeds 76 d) Sidewall height exceed 96" INSTALLATION OF GROUND PAN 2. Remove weeds and debris in an approximate two foot square to expose firm soil for each ground pan (C) 3. Place ground pan (C) directly below chassis I-beam. Press or drive pan firmly into soil until flush or belibyy ol) then install pier per manufacturer's instructions or per Florida Regs. ' SPECIAL NOTE: The longitudinal'"V" brace system may also serve as a pier under the home an&s' hould be loaded as any other pier: It is recommended that after leveling piers, and one-third inch (1/3") before home is loweredm copletely on to piers, complete steps 4 through 9 below then remove jacks. INSTALLATION OF LONGITUDINAL "V" BRACE SYSTEM {Model 110 t L "1t") NOTE: WHEN INSTALLINGTHE LONGITUDINAL SYSTEM ONLY, A MINIMUM OF 2 SYSTEMS PER FLOOR'SECTION IS REQUIRED. SOIL TEST PROBE SHOULD BE USED TO DETERMINE CORRECT TYPE OF ANCHOR PER SOIL CLASSIFICATION. IF PROBE TEST READING5'ARE BETWEEN 175 & 275 A 5 FOOT ANCHOR MUST BE USED. IF PROBETEST READINGS ARE BETWEEN 276 & 350 A 4 FOOT ANCHOR MAY BE USED UIE GROUND ANCHORS WITH DIAGONALTIES AND STABILIZER PLATES EVERY 5'4' . VERTICALTIE5 ARE ALSO REQUIRED ON HOMES SUPPLIED WITH VERTICAL TIE CONNECTION POINTS (PER FLORIDA REG.). ,, 4. Choose one of the approved longitudinal tube installations; either diagram for appropriate pier height at support location or cut and PIER HEIGHT 1.25" 1.50" (400 Min. - 450 Max.) Tube Length Tube Length 7 3/4" to 25" 22" 24 3/4" to 321 /4" 32" 18`" 33" to 41 " 44' ss �- 1;8" 40" to 48" 54" 18" Part E or B. Then select the correct square tube (E) length from the .tare tube to achieve appropriate length. PIER HEIGHT 1.50" 2y holed (40° Min. - 60' Max.) Tube Length 14" to 1 B" 20" 18" to 25" 28" 24" to 35" 39". 30" to 40" 44" 36" to 4$" 54" Diagram A Diagram B 5. Install f2) of the 1.50"'square tubes (E) �n%o;the "U" bracket (1), insert carriage bolt and leave nut loose for final adjustment. 6. Place I-beam connector (F) loosely,on thebottom flange. of the I-beam. 7. (For Diagram A installation) Slide fFe selected 1.25" tube (E) into a 1.50" tube (E) and attach to I-beam connectors. (F) and fasten loosely with bolt and nut. (For Diagram 8 installation) Attach the selected 1,5"tubes (E).to the I-beam connectors (F) and fasten loosely with bolts and nuts. S. Repeat steps 6 through 7 to create the"V" pattern of the square tubes loosely in place. 9. Using standard hand tools tighten all nuts and bolts. (For Diagram A installation only, secure 1.25" and 1 .50" tubes using. four(4) 1 /4"-1'4 x 3/4" self -tapping screws in pre -drilled holes.) INSTALLATION OF LATERAL TELESCOPING TRANSVERSE ARM SYSTEM (Model 1101 T "V" ) THE MODEL 1101 "V" (LONGITUDINAL & LATERAL PROTECTION) ELIMINATES THE NEED FOR STABILIZER PLATES & FRAMETIES. NOTE:THE USE OF THIS. SYSTEM REQUIRES VERTICALTIES SPACED AT 5'4". FOUR FOOT (4') GROUND ANCHOR MAY BE USED EXCEPT WHERE THE HOME MANUFACTURER SPECIFIES DIFFERENT. 101 Install remaining vertical tie -down straps and N ground anchors per home manufacturer's instructions. NOTE: Centerline anchors to be sized according to soil torque condition. Any manufacturer's specifications for sidewall anchor loads in excess of 4,000 lbs. require a 5' anchor per Florida Code. 11. select the correct square tube brace(H) length for set-up lateral transverse at support location. The lengths come in either 60" or 72" lengths, (With the 1.50" tube as the bottom tube, and the 1.25" tube as the inserted tube.) 12. Install the 1.50 transverse brace (H) to the ground pan connector (D) with bolt and nut. 13. Slide 1.25'" transverse brace into the 1.50" brace and attach to adjacent I-beam connector (1) with bolt and nut. 14. Secure 1.5W transverse arm to 1.25" transverse arm using four (4)1 /4•" -14 x 31N' self -tapping screws in pre -drilled holes.Revision 08 P23/1 E pATFNT1t FA;A1 r%n !L OTHER AATFNT PFNnINr, FILE COP" 467 Swan Ave • Hohenwald. TN 38462 ® (800) 284-7437 s www.olivertechnologie5.com INSTALLATION USING CONCRETE RUNNER/ TOOTER 15. A concrete runner, footer or slab may be used in place of the steel ground pan. Fax (931) 796-881 1 a) The concrete shall be minimum 2500 psi mix b) A concrete runner may be either longitudinal or transverse, and must be a minimum of 8" deep with a minimum width of 16 inches longitudinally or 18 inches transverse to allow proper distance between the concrete bolt and the edge of the concrete (see below). c) Footers must.have minimum surface area of 441 sq. in. (I.e. 21" square), and must be a minimum of 8" deep. d) If a full slab is used, the depth must be a 4" minimum, Special inspection of the system bracket installation is not required. Footers must allow for at least V from the concrete bolt to the edge of the concrete. NOTE: The bottom of all footings, pads, slabs and runners must be per local jurisdiction. LONGITUDINAL. Model 1101 LC"V" 16. When using Part# 1101-W-CPCA (wetset) simply install the bracket in runner/footer OR When installing in cured concrete use Part# 101-D-CPCA (dryset}.The 1101 (dryset) CA bracket is attached to the concrete using (2) 5/8"xY concrete wedge bolts (Simpson part # S162300H 5/8" X 3" or Powers equivalent). Place the CA bracket in desired location. Mark bolt holelocations, then using a 5/8" diameter masonry bit, drill a hole to a minimum depth of 3". Make sure all dust and concrete is blown out of:the,h_oles. Place wedge bolts into drille holes, then place 1101 (dry set) CA bracket onto wedge bolts and start wedge bolt nuts. Take a. hammer and lightly drive the wedge bolts down by hitting the nut (making sure not to hit the top of threads on bolt). The sleeve of con eke wedge bolt needs to be at or below thr too of concrete. Complete by tightening nuts. LATERAL: (Model 11 01TC "V' 17. For wet set (part # 1101-W TACA) installation simply install the anchor bolt 1 nto,fu n ner/f" oteii For dry set installation {part It 1101-D TACA mark bolt hole locations, then using a 5/8" diam. masonry bit. drill a hole toa minimum depth of 3". Make sure all dust and concrete is blown out of the hole. Place wedge bolts (Simpson part #S 162300H 5/8' X 3" or Powersequivalent) into (D) concrete dry transverse connector and into drilled hole. If needed, take a hammer and lightly,drive the wedge'bolts down by hitting the. nut (making sure not to hit the top of threads on bolt), then remove the nut. The sleeve of concrete weage c 8. When using part# 1101 CVW (wetset) or 1101 CVD (dryset), instal( pe'r- teps:l<7;&.18. Notes: 1. LENGTH OF HOUSE IS THE ACTUAL BOX SIZE 2.'t_ LOCATION OF TRANSVERSExBRACING ONLY 3 , = LOCATION OF LdNGITUDINAti 03RACING ONLY =TRANSVERSE AND LONGITUDINAL LOCATIONS ALLHS AND L alv� t ( ' i i i fIi I -IT �' ENGTHS UP TO52' i rqj 1 fl ALL WIDTHS AND LENGTHS OVER52'TO 8W ti I HOMES WITH 5/12 ROOF PITCH REQUIRE: PER FLORIDA REGULATIONS 6 systems for home lengths up to 52' and 8 systems for homes over 52' and up 80'. PATENT# 6634150 & OTHER PATENT PENDING Pie Revision 08/23/1 E FIDE COPY I -Transverse Arm, I -Beam Connector 0 - Pan Transverse H-Transverse Arm / Top 0.251 Bottom (1 s") C - Ground Pan I -Transverse Arm, I -Beam Connector t CemeeBlock Omitted; t s LFor Clarity D - Concrete 1 1_ '6� Connector C eeteSl FootaYer Part+l 11Dt-D-TACA H - Transverse Aim Part # 1101- W - TACA not shovm / Top 0.251 Bottom,(15") t CMU-Pier 1� Omitted I LFor Clarity iZy 18' Max. ` Bolts Model # 110.1 T "V" Model # 1101 TC W" a Florida approved 4' ground anchors may be used in all locations except where home manufacturers specifications for sidewail straps are in excess of 4,000'ibs.These locationsrequire a S' anchor. Per Florida code. Y, C = GROUND PAN ! CONCRETE FOOTER OR RUNNER D = GROUND PAN / CONCRETE U BRACKETS TRANSVERSE CONNECTOR (connects with grade 5`, 1 /2"�k.2" 1/2" carriage bolt and nut) E = TELESCOPING V BRACE TUBE ASSEMBU/ 0.5" TUBE BOTTOM AND 1.25" TUBE INSERT) OR 1 5," TUBE c = "V" BRACE 1-BEAM CONNECTOR ASSEMBLY H = TELESCOPING TRANSVERSE ARM ASSEMBLY 1 = TRANSVERSE ARM I -BEAM CONNECTOR (connects with grade 5 -1 /2" x Zigj /2" carnage bolt and nut) J = V PAN BRACKET (connects with grade 5 -1/2"x 2" 1/2"carriage bolt and nut) 3�( S f t 1 I -Transverse Arm.I-Beam Connector /f F - "V" Brace I -Beam z H -Transverse Arm Connedors %Top (1.25") Bottom(1,51 D - Pan Transverse. Connector ! Concrete Transverse Bracket C - Ground Pan — / Concrete Tooter E - "V" Brace Tube (1.5"1 ';;./' 1) - Pan V Bracket Concrete V Bracket 1 1 Model # 1101 "V" PATENT# 6634150 & OTHER PATENT PENDING Part 1101 D•CPCA. Pait 91101 V)-CPCA not shown Model # 1101 C "V" Pam. FILE COP tision 08/23/1 E