Loading...
HomeMy WebLinkAboutResidential Heat Loss and Heat Gain CalculationsPage 1 Residential Heat Loss and Heat Gain Calculation 2/6/2020 In accordance with ACCA Manual J Report Prepared By: Central Air Systems inc. For: Design Conditions: Fort Pierce Indoor: Summer temperature: 70 Winter temperature: 70 Relative humidity: 55 Outdoor: Summer temperature: 90 Winter temperature: 42 Summer grains of moisture: 127 Daily temperature range:Medlum Building Component Sensible latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Duct 5,166 0. 5,166 2,824 Floors 2.344 0 2,344 4,166 Walls 1,997 0 _ 1,897 2,250 Fireplaces 0 0 _0 _ . 0 MID 1,200 0 1,200 0. Windows 13,754 0 13,754 5,762 Doors 1,066 0 1,066 1,266 Glassdoors 3.658 0 3.658 1.392 11,121 9,968 Whole House 39,607 8,650 48,257 31,066 (4 tons ) HVAC-Cale Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only, actual loads May very due to weather and cobslruedon differences. FILE COPY