HomeMy WebLinkAboutResidential Heat Loss and Heat Gain CalculationsPage 1 Residential Heat Loss and Heat Gain Calculation 2/6/2020
In accordance with ACCA Manual J
Report Prepared By:
Central Air Systems inc.
For:
Design Conditions: Fort Pierce
Indoor:
Summer temperature: 70
Winter temperature: 70
Relative humidity: 55
Outdoor:
Summer temperature: 90
Winter temperature: 42
Summer grains of moisture: 127
Daily temperature range:Medlum
Building Component
Sensible
latent
Total
Total
Gain
Gain
Heat Gain
Heat Loss
(BTUH)
(BTUH)
(BTUH)
(BTUH)
Duct
5,166
0.
5,166
2,824
Floors
2.344
0
2,344
4,166
Walls
1,997
0
_
1,897
2,250
Fireplaces
0
0
_0
_ . 0
MID
1,200
0
1,200
0.
Windows
13,754
0
13,754
5,762
Doors
1,066
0
1,066
1,266
Glassdoors
3.658
0
3.658
1.392
11,121 9,968
Whole House 39,607 8,650 48,257 31,066
(4 tons )
HVAC-Cale Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101
Load calculations are estimates only, actual loads May very due to weather and cobslruedon differences.