Loading...
HomeMy WebLinkAboutEnergy CodeD'J'30cm 1 &Joruk 9 c -, ' } rca ec4 s ummL.dy 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts 2. Single-family or multiple -family 2. Single-family b) Return ducts c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 1335 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.600 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.240 c) Area 7c. 97.6 8. Skylights a) U-factor:(weighted average) b) Solar Heat Gain Coefficient (SHGC) 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 8a. NA 8b. NA 9a. 0.0 9b. 9c. 10A1. 10A2. 5.0 10131. 10132. 5.0 11 a. 30.0 11 b. 11 c. 11d. No 13. Cooling system: Capacity27.6 a) Split system. SEER 16.0 b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity27.3 a) Split system heat pump HSPF b) Single package heat pump HSPF c). Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF 0 Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes b) Cross ventilation Yes c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit 0 Programmable thermostat No *Label required by Section R303.1.3-of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection: Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature `' - Date: Address of New Home: Lot 7-9 Notlem Drive City/FL Zip: Fort Pierce FL 2/4/2021 3:20:04 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition ,(2017) Compliant Software Page 1 of 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LOT 5 and 6 Notlem Drive Fort Pierce Builder Name: Habitat for Humanity Street: LOT 5-6 Notlem Drive Permit Office: City, State, Zip: Fort Pierce , FL, Permit Number: Owner: Joseph Gianna Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) ' 9. Wall Types (1248.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1080.00 ft2 b. Concrete Block - Int Insul, Adjacent R=5.0 168.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1292.9 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1292.00 ft 6. Conditioned floor area above grade (ft2) 1292 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(85.1 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 258 a. U-Factor: Dbl, U=0.60 85.14 ft2 SHGC: SHGC=0.24 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 27.6 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency A. U-Factor: N/A ft2 a. Electric Strip Heat 27.3 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.240 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1291.0 sqft.) Insulation Area EF`.'0.950 a. Slab -On -Grade Edge Insulation R=0.0 1291.00 ft2 b. Conservation features b.-N/A R= ft2. None . c. N/A R= ft2 15. Credits CV Total Proposed Modified Loads: 44.01 Glass/Floor Area: 0.066 PASS wSS Total Baseline Loads: . 44.49 /� I hereby certify that the plans and specifications covered by Review of the plans and TBE STgT this calculation are in compliance with the Florida Energy specifications covered by this = �0�, Code. calculation indicates compliance �•,� •; �.����� n PREPARED BY: �` DATE: February 4, 2021 with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 -P;i I hereby certify that this building, as designed; is in compliance Florida Statutes. COD with the Florida Energy Code. WE L"1-1 OWNER/AGENT: BUILDING.OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test reportwith envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1. of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: LOT 5 and 6 Notlem Drive For Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1292 Lot # Owner Name: Joseph Gianna Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Habitat for Humanity Rotate Angle: 0 Street: LOT 5-6 Notlem Drive Permit Office: J Cross Ventilation: Yes County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1292 10336 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 3 131 1048 No 1 1 1 Yes Yes Yes 2 KITCHEN 116 928 Yes 0 1 Yes Yes Yes 3 pnty 11 88 No 0 1 No Yes Yes 4 BATH 50 396 No 0 1 No Yes Yes 5 Laundry 72 572 No 0 1 Yes Yes Yes 6 BATH 1 66 528 No 0 1 Yes Yes Yes 7 Master Bed 162 1296 No 2 1 1 Yes Yes Yes 8 M CL 25 196 No 0 1 Yes Yes Yes 9 BEDROOM 2 144 1152 No 1 1 1 Yes Yes Yes 10 CL 3 15 120 No 0 1 No Yes Yes 11 CL 2 16 130 No 0 1 Yes Yes Yes 12 Hall 61 488 No 0 1 No Yes Yes 13 LIVING ROOM 423 3384 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 3 10.5 ft 131.3 ft2 ___ 1 0 0 2 Slab -On -Grade Edge Insulatio KITCHEN 21.5 ft 115.5 ft2 ___ 1 0 0 3 Slab -On -Grade Edge Insulatio pnty 1 ft 11 ft2 1 0 0 4 Slab -On -Grade Edge Insulatio BATH 1 ft 49.5 ft2 ___ 1 0 0 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 IMPHT Sl1MMORY CHFCICI IST RFP[)RT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio Laundry lift 71.5 ft2 ___ 1 0 0 6 Slab -On -Grade Edge Insulatio BATH 1 5.5 ft 66 ft2 ___ 1 0 0 7 Slab -On -Grade Edge Insulatio Master Bed 25.5 ft 162 ft2 ___ 1 0 0 8 Slab -On -Grade Edge Insulatio M CL 3.5 ft 24.5 ft2 ___ 1 0 0 ' 9 Slab -On -Grade Edge Insulatio BEDROOM 2 24 ft 143.8 ft2 1 0 0 10SIab-On-Grade Edge Insulatio CL 3 1 ft 15 ft2 1 0 0 11Slab-On-Grade Edge Insulatio CL 2 2.5 ft 16.3 ft2 ___ 1 0 0 12SIab-On-Grade Edge Insulatio Hall 1 ft 61.3 ft2 1 0 0 13SIab-On-Grade Edge Insulatio LIVING ROOM 52 ft 423.3 ft2 ___ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1361 ft2 214 ft2 Medium N 0.9 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1291 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 3 30 Blown 131 ft2 0.1 Wood 2 Under Attic (Vented) KITCHEN 30 Blown 116 ft2 0.1 Wood 3 Under Attic (Vented) pnty 30 Blown 11 ft2 0.1 Wood 4 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 5 Under Attic (Vented) Laundry 30 Blown 72 ft2 0.1 Wood 6 Under Attic (Vented) BATH 1 30 Blown 66 ft2 0.1 Wood 7 Under Attic (Vented) Master Bed 30 Blown 162 ft2 0.1 Wood 8 Under Attic (Vented) M CL 30 Blown 25 ft2 0.1 Wood 9 Under Attic (Vented) BEDROOM 2 30 Blown 144 ft2 0.1 Wood 10 Under Attic (Vented) CL 3 30 Blown 15 ft2 0.1 . Wood 11 Under Attic (Vented) CL 2 30 Blown 16 ft2 0.1 Wood 12 Under Attic (Vented) Hall 30 Blown 61 ft2 0.1 Wood 13 Under Attic (Vented) LIVING ROOM 30 Blown 423 ft2 0.1 Wood 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS # Ornt Adjacent Space To Wall Type Cavity Width Height Sheathing Framing Solar Below 1 W Exterior Concrete Block - Int InsSEDROOM 3 5 10 6 8 0 84.0 ft2 0 0 0.5 0 2 E Exterior Concrete Block - Int Insul KITCHEN 5 10 6 8 0 84.0 ft2 0 0 0.5 0 _ 3 N Garage Concrete Block - Int Insul KITCHEN 5 11 0 8 0 88.0 ft2 0 0 0.5 0 4 E Exterior Concrete Block - Int Insul Laundry 5 11 0 8 0 88.0 ft2 0 0 0.5 0 5 E Exterior Concrete Block - Int Insul BATH 1 5 5 6 8 0 44.0 ft2 0 0 0.5 0 6 E Exterior Concrete Block - Int InsuMaster Bed 5 13 6 8 0 108.0 ft2 0 0 0.5 0 7 S Exterior Concrete Block - Int InsuMaster Bed 5 12 0 8 0 96.0 ft2 0 0 0.5 0 8 S Exterior Concrete Block - Int Insul M CL 5 3 6 8 0 28.0 ft2 0 0 0.5 0 9 S Exterior Concrete Block - Int InsfilEDROOM 2 5 12 6 8 0 100.0 ft2 0 0 0.5 0 10 W Exterior Concrete Block - Int InsdfEDROOM 2 5 11 6 8 0 92.0 ft2 0 0 0.5 0 11 W Exterior Concrete Block - Int Insul CL 2 5 2 6 8 0 20.0 ft2 0 0 0.5 0 12 N Exterior Concrete Block - Int InsiilIVING ROO 5 16 6 8 0 132.0 ft2 0 0 0.5 0 13 W Exterior Concrete Block - Int InsdlIVING ROO 5 25 6 8 0 204.0 ft2 0 0 0.5 0 14 E Garage Concrete Block - Int InsddIVING ROO 5 9 6 8 0 76.0 ft2 0 0 0.5 0 15 N Garage Concrete Block - Int InsWIVING ROO 5 0 6 8 0 4.0 ft2 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood LIVING ROO None .39 3 7 21 ft2 2 W Wood LIVING ROO None .39 3 2 7 22.2 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 None Double (Clear) Yes 0.6 0.24 Y 16.9 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 2 E 2 None Double (Clear) Yes 0.6 0.24 Y 10.0 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 3 S 7 None Double (Clear) Yes 0.6 0.24 Y 16.9 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 S 9 None Double (Clear) Yes 0.6 0.24 Y 16.9 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 5 N 12 None Double (Clear) Yes 0.6 0.24 Y 24.4 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wail Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000355 1204.7 66.14 124.38 .1231 7 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 I, J . FORM R405-2017 INPUT SUMMARY CHFCKI _IST RFP0RT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27.3 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 27.6 kBtu/hr cfm 0.72 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Laundry 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / --- Supply --- -- Return -- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 258 ft' Attic 64 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Heat ng [X] an pC] Feb kiMar Apr Apr Jun g ur rl Jun Jul A Se Sep rj Oct No Dee Venting j ]Jan [ ]Feb Mar May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 pnty e Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bed Default(8 Ibs/sq.ft. ft2 ft 0.3 M CL Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CL 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CL 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall Default(8 Ibs/s .ft. ft2 ft 0.3 LIVING ROOM 2/4/2021 3:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6