HomeMy WebLinkAboutEnergy CodeD'J'30cm 1 &Joruk 9 c -, ' } rca ec4
s ummL.dy
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts
2. Single-family or multiple -family 2. Single-family b) Return ducts
c) AHU location Garage
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3
5. Is this a worst case? (yes/no) 5. No
6. Conditioned floor area (sq. ft.) 6. 1335
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.600
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.240
c) Area 7c. 97.6
8. Skylights
a) U-factor:(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
8a. NA
8b. NA
9a. 0.0
9b.
9c.
10A1.
10A2. 5.0
10131.
10132. 5.0
11 a. 30.0
11 b.
11 c.
11d. No
13. Cooling system: Capacity27.6
a) Split system. SEER 16.0
b) Single package SEER
c) Ground/water source SEER/COP
d) Room unit/PTAC EER
e) Other
14. Heating system:
Capacity27.3
a) Split system heat pump
HSPF
b) Single package heat pump HSPF
c). Electric resistance
COP 1.0
d) Gas furnace, natural gas
AFUE
e) Gas furnace, LPG
AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
0 Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans Yes
b) Cross ventilation Yes
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
0 Programmable thermostat No
*Label required by Section R303.1.3-of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection: Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature `' - Date:
Address of New Home: Lot 7-9 Notlem Drive City/FL Zip: Fort Pierce FL
2/4/2021 3:20:04 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition ,(2017) Compliant Software Page 1 of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LOT 5 and 6 Notlem Drive Fort Pierce
Builder Name: Habitat for Humanity
Street: LOT 5-6 Notlem Drive
Permit Office:
City, State, Zip: Fort Pierce , FL,
Permit Number:
Owner: Joseph Gianna
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans) '
9. Wall Types (1248.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1080.00 ft2
b. Concrete Block - Int Insul, Adjacent
R=5.0 168.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1292.9 sgft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1292.00 ft
6. Conditioned floor area above grade (ft2) 1292
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(85.1 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 258
a. U-Factor: Dbl, U=0.60 85.14 ft2
SHGC: SHGC=0.24
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
27.6 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
A. U-Factor: N/A ft2
a. Electric Strip Heat
27.3 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.240
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1291.0 sqft.) Insulation Area
EF`.'0.950
a. Slab -On -Grade Edge Insulation R=0.0 1291.00 ft2
b. Conservation features
b.-N/A R= ft2.
None .
c. N/A R= ft2
15. Credits
CV
Total Proposed Modified Loads: 44.01
Glass/Floor Area: 0.066
PASS
wSS
Total Baseline Loads: . 44.49
/�
I hereby certify that the plans and specifications covered by
Review of the plans and
TBE STgT
this calculation are in compliance with the Florida Energy
specifications covered by this
= �0�,
Code.
calculation indicates compliance
�•,� •;
�.�����
n
PREPARED BY: �`
DATE: February 4, 2021
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
-P;i
I hereby certify that this building, as designed; is in compliance
Florida Statutes.
COD
with the Florida Energy Code.
WE
L"1-1
OWNER/AGENT:
BUILDING.OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test reportwith envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1. of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: LOT 5 and 6 Notlem Drive For Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1292
Lot #
Owner Name: Joseph Gianna
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: Habitat for Humanity
Rotate Angle: 0
Street:
LOT 5-6 Notlem
Drive
Permit Office:
J
Cross Ventilation: Yes
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1292 10336
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 BEDROOM 3
131 1048 No
1
1
1
Yes
Yes
Yes
2 KITCHEN
116 928 Yes
0
1
Yes
Yes
Yes
3 pnty
11 88 No
0
1
No
Yes
Yes
4 BATH
50 396 No
0
1
No
Yes
Yes
5 Laundry
72 572 No
0
1
Yes
Yes
Yes
6 BATH 1
66 528 No
0
1
Yes
Yes
Yes
7 Master Bed
162 1296 No
2
1
1
Yes
Yes
Yes
8 M CL
25 196 No
0
1
Yes
Yes
Yes
9 BEDROOM 2
144 1152 No
1
1
1
Yes
Yes
Yes
10 CL 3
15 120 No
0
1
No
Yes
Yes
11 CL 2
16 130 No
0
1
Yes
Yes
Yes
12 Hall
61 488 No
0
1
No
Yes
Yes
13 LIVING ROOM
423 3384 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 3 10.5 ft
131.3 ft2
___
1 0
0
2 Slab -On -Grade Edge Insulatio
KITCHEN 21.5 ft
115.5 ft2
___
1 0
0
3 Slab -On -Grade Edge Insulatio
pnty 1 ft
11 ft2
1 0
0
4 Slab -On -Grade Edge Insulatio
BATH 1 ft
49.5 ft2
___
1 0
0
2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 IMPHT Sl1MMORY CHFCICI IST RFP[)RT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
Laundry lift
71.5 ft2
___
1
0
0
6 Slab -On -Grade Edge Insulatio
BATH 1 5.5 ft
66 ft2
___
1
0
0
7 Slab -On -Grade Edge Insulatio
Master Bed 25.5 ft
162 ft2
___
1
0
0
8 Slab -On -Grade Edge Insulatio
M CL 3.5 ft
24.5 ft2
___
1
0
0
' 9 Slab -On -Grade Edge Insulatio
BEDROOM 2 24 ft
143.8 ft2
1
0
0
10SIab-On-Grade Edge Insulatio
CL 3 1 ft
15 ft2
1
0
0
11Slab-On-Grade Edge Insulatio
CL 2 2.5 ft
16.3 ft2
___
1
0
0
12SIab-On-Grade Edge Insulatio
Hall 1 ft
61.3 ft2
1
0
0
13SIab-On-Grade Edge Insulatio
LIVING ROOM 52 ft
423.3 ft2
___
1
0
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Composition shingles 1361 ft2
214 ft2
Medium
N
0.9
No 0.9
No 0
18.4
ATTIC
/
V # Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
300
1291 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
BEDROOM 3
30
Blown
131 ft2
0.1
Wood
2 Under Attic (Vented)
KITCHEN
30
Blown
116 ft2
0.1
Wood
3 Under Attic (Vented)
pnty
30
Blown
11 ft2
0.1
Wood
4 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
5 Under Attic (Vented)
Laundry
30
Blown
72 ft2
0.1
Wood
6 Under Attic (Vented)
BATH 1
30
Blown
66 ft2
0.1
Wood
7 Under Attic (Vented)
Master Bed
30
Blown
162 ft2
0.1
Wood
8 Under Attic (Vented)
M CL
30
Blown
25 ft2
0.1
Wood
9 Under Attic (Vented)
BEDROOM 2
30
Blown
144 ft2
0.1
Wood
10 Under Attic (Vented)
CL 3
30
Blown
15 ft2
0.1 .
Wood
11 Under Attic (Vented)
CL 2
30
Blown
16 ft2
0.1
Wood
12 Under Attic (Vented)
Hall
30
Blown
61 ft2
0.1
Wood
13 Under Attic (Vented)
LIVING ROOM
30
Blown
423 ft2
0.1
Wood
2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#
Ornt
Adjacent Space
To Wall Type
Cavity Width
Height
Sheathing Framing Solar
Below
1
W
Exterior
Concrete Block - Int InsSEDROOM 3
5 10
6
8 0
84.0 ft2
0
0 0.5
0
2
E
Exterior
Concrete Block - Int Insul KITCHEN
5 10
6
8 0
84.0 ft2
0
0 0.5
0
_ 3
N
Garage
Concrete Block - Int Insul KITCHEN
5 11
0
8 0
88.0 ft2
0
0 0.5
0
4
E
Exterior
Concrete Block - Int Insul Laundry
5 11
0
8 0
88.0 ft2
0
0 0.5
0
5
E
Exterior
Concrete Block - Int Insul BATH 1
5 5
6
8 0
44.0 ft2
0
0 0.5
0
6
E
Exterior
Concrete Block - Int InsuMaster Bed
5 13
6
8 0
108.0 ft2
0
0 0.5
0
7
S
Exterior
Concrete Block - Int InsuMaster Bed
5 12
0
8 0
96.0 ft2
0
0 0.5
0
8
S
Exterior
Concrete Block - Int Insul M CL
5 3
6
8 0
28.0 ft2
0
0 0.5
0
9
S
Exterior
Concrete Block - Int InsfilEDROOM 2
5 12
6
8 0
100.0 ft2
0
0 0.5
0
10
W
Exterior
Concrete Block - Int InsdfEDROOM 2
5 11
6
8 0
92.0 ft2
0
0 0.5
0
11
W
Exterior
Concrete Block - Int Insul CL 2
5 2
6
8 0
20.0 ft2
0
0 0.5
0
12
N
Exterior
Concrete Block - Int InsiilIVING ROO
5 16
6
8 0
132.0 ft2
0
0 0.5
0
13
W
Exterior
Concrete Block - Int InsdlIVING ROO
5 25
6
8 0
204.0 ft2
0
0 0.5
0
14
E
Garage
Concrete Block - Int InsddIVING ROO
5 9
6
8 0
76.0 ft2
0
0 0.5
0
15
N
Garage
Concrete Block - Int InsWIVING ROO
5 0
6
8 0
4.0 ft2
0
0 0.5
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood LIVING ROO
None
.39
3
7
21 ft2
2
W
Wood LIVING ROO
None
.39
3
2
7 22.2 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W 1
None Double (Clear) Yes
0.6 0.24
Y
16.9 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
2
E 2
None Double (Clear) Yes
0.6 0.24
Y
10.0 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
3
S 7
None Double (Clear) Yes
0.6 0.24
Y
16.9 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
4
S 9
None Double (Clear) Yes
0.6 0.24
Y
16.9 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
5
N 12
None Double (Clear) Yes
0.6 0.24
Y
24.4 ft2
2 ft 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wail Height
Exposed Wall Insulation
1
382.8 ft2 382.8 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000355 1204.7 66.14
124.38
.1231
7
2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
I, J .
FORM R405-2017 INPUT SUMMARY CHFCKI _IST RFP0RT
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA 27.3 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 16 27.6 kBtu/hr cfm
0.72
1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric None
Laundry
0.95 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
/
--- Supply ---
-- Return -- Air
CFM 25
CFM25
HVAC #
�/ #
Location R-Value Area
Location
Area Leakage Type Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6 258 ft'
Attic
64 ft2 Default Leakage Garage
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Heat ng [X]
an
pC] Feb kiMar
Apr
Apr
Jun g
ur
rl Jun Jul A
Se
Sep
rj
Oct
No
Dee
Venting j
]Jan [ ]Feb Mar
May Jun Jul Aug
Sep
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6 7
8
9
10
11
12
Cooling (WD)
AM 78
78 78
78 78 78 78
78
80
80
80
80
PM 80
80 80
80 78 78 78
78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78 78
78
80
80
80
80
PM 80
80 80
80 78 78 78
78
78
78
78
78
Heating (WD)
AM 65
65 65
65 65 65 65
68
68
68
68
68
PM 68
68 68
68 68 68 68
68
68
68
68
68
Heating (WEH)
AM 65
65 65
65 65 65 65
68
68
68
68
68
PM 68
68 68
68 68 68 68
68
68
68
68
68
2/4/2021 3:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
pnty
e Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bed
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M CL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CL 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CL 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall
Default(8 Ibs/s .ft.
ft2
ft
0.3
LIVING ROOM