Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
ry ProjectSumma Job: LOT 6-6 Nollem Drive, Fort ft... -- wrightSo� Date: February Entire House W. Josh Putrnan Webreps LLC Plan: LOT Wdem Drive 1880 82nd Pue, Vero Beach, FI 32966 Phone: (800) 810-3280 Project• • For. Joseph Gianna St Lucie Habitat for Humanity 702 South 6th Street, Fort Pierce, FL Phone: (772) 464-1117 Email: joseph@stiuciehabitatorg . Notes: LOT 5-6 Notiem Drive, Fort Pierce, FL. Weather. Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 72 OF Design TD 30 OF Heating Summary Structure 15602 Btuh Ducts 3245 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 122 Btuh Piping 0 Btuh Equipment load 18969 Btuh Infiltration Method Simplified Construction quality Semi -tight Fireplaces 0 Heating Coaling Area (ft) 129i 1291 Volume (ftl) 10326 10326 Air changesthour 0.31 0.16 Equiv AVF (cfm) 53 28 Heating Equipment Summary Make Goodman Trade Heat Strip Model AHRI ref Efficiency Heating Input Heating output Temperature rise Actual airflow Air flowfactor Static pressure Space thermostat Summer Design Conditions. Outside db 90 OF Inside db 75 OF Design TD 15 OF' Daily range M Relative humidity 50 % Moisture difference 61 grRb Sensible Cooling Equipment Load Sizing Structure 12472 Btuh Ducts 5286 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 1707 Btuh Use manufacturees'data y Rate/swing multiplier 1.00 Equipment:senslble load 19465 Btuh Latent Cooling Equipment Load Sizing Structure 5850 Btuh Ducts 1501 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 7352 Btuh Equipment Total Load (Sen+Lat) 26816 Btuh Req. total capacity at 0.72 SHR 2.3 'ton Cooling Equipment. Summary Make Goodman Mfg. Trade GOODMAN Cond GSX160301 F Coil ASPT30C14A AHRI ref 200825240 100 EFF Efficiency 8.0 kW Sensible cooling 27297 Btuh Latent cooling 27 OF Total cooling 920 cfin Actual airflow 0.049 cfm/Btuh. Airflowfactor 0.60 in H2O Static pressure Load sensible heat ratio 13.0 EER,16 SEER 19872 Btuh 7728 Btuh 27600 Btuh 920 cfm 0.052. cfm/Btuh 0.60 in H2O 0.73 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -*- wrightsoTt 2021-Feb-1215:58:55 Right-Suite®Universal 2021 21.0.03 RSU16998 Page 1 ACe A ...ityPSLILOT 5-6 Notlem Drive Fort PierceFL_ rup Calc= MJ8 faces: N y. i. 16" MAIN FLOOR Job M LOT 6-6 Nodem Drive, Fort Pierce, FL Webreps LLC Scale: 1 : 86 Performed by Josh Putman for: Page 1 Joseph Gianna 1880 82ndAve Right Suite® Universal 2021 702 South 6th Street Mero Beach, FI 32966 21.0.03 RSU16998 Fort Pierce, FL Phone: (800) 810-3280 2021-Feb-1215:59:02 Phone: (772) 464-1117 Notlem Drive Fort PieroeFL_ rup joseph@stluciehabitatorg ~ + wrightsofto Load Short Form Entire House Webreps LLC 1880 82nd Aie, Vero Beach, R 32966 Phone: (800) 810-3280 Project For. Joseph Gianna, St Lucie Habitat for Humanity 702 South 6th Street, Fort Pierce, FL Phone: (772) 464-1117 Email: joseph@stiuciehabitatorg Job: LOT 5-6 Notlem Drive, Fort ... Data: February 4, 2021 By: Josh Putman Plan: LOT 5-6Notlem Drive Design Information Htg Clg Infiltration Outside db (OF) 42 90 Method Simplified Inside db (OF) 72 75 Construction quality Semi -tight Design TD (OF) 30 15 Fireplaces 0 Daily range - M Inside humidity (%) 30 50 Moisture difference (grAb) 3 61 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Make Goodman Mfg. Trade Heat Strip Trade GOODMAN Model Cond GSX160361 F AHRI ref Coil ASPT30C14A AHRI ref 200825240 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating input 8.0 kW Sensible cooling 19872 Btuh Heating output 27297 Btuh Latent -cooling 7728 Btuh Temperature rise 27 OF Total cooling 27600 Btuh Actual airflow 920 cfm Actual airflow 920 cfrn Airflowfactor 0.049 cfmBtuh Airflowfactor 0.052 cfmBtuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.73 ROOM NAME Area (ft� Htg load (Btuh) Clg load (Btuh) HtgAVF (cfm) CIgAVF (cfm) BEDROOM 3 131 1669 2279 81 118 KITCHEN 116 2206 3791 108 196 pnty 11 0 0 0 0 BATH 50 73 280 4 15 Laundry 72 1198 1149 58 60 BATH 1 66 644 312 31 16 Master Bed 162 3261 2456 159 127 M CL 25 0 0 0 0 BEDROOM 2 144 3229 2114 158 110 CL 3 15 0 0 0 0 CL 2 16 0 0 0 0 Hall 61 0 0 0 0 t 1%/IAI(_ Dnnnn A72 02=7 c4'7r- 77n Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-1215:58:55 �- wrightsoft- ht-Suite® Universal 2021 21.0.03 RSU76998 Page 1 ACM ...ity PSLIOT 5-6 Notlem Drive Fort PierceFL_.rup Calc= MA faces: N Entire House a -1291 18847 17758 920 920 Other equip loads .122 1707 .. Equip. @ _ 1.00. RSM 19465 Latent cooling . 7352 TOTAIS w 19Q1 1RQRQ 9RR1R Q9n - Qgn Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -- wrightsoftm 2021-Feb-1215:58:55 �'� 6na NIBM F4 laOeweY mmp ry Right-Suite®Universal 2021 21.0.03 RSU16998 Page 2 . ACCA ...ity PSLILOT 5-6 Notlem Drive Fort PierceFL_.rup Calc= MJ8 faces: N_ r: yY't - wrightsoft" Duct System Summary Entire House Webreps LLC 1880 82nd Are, Vero Beach, R 32966 Phone: (800) 810-3280 rroject Intormation For. Joseph Gianna, St Lucie Habitat for Humanity 702 South 6th_Street, Fort Pierce, FL Phone: (772) 464-1117 Email: joseph@stluciehabitatorg Job: LOT 6-6 Notlem Drive, Fort... Date: February 4, 2021 By: Josh Putman Plan: LOT 5-6 Notlem Drive Heating Cooling External static pressure 0.60 in H2O 0.60 in H2O Pressure losses 0.24 in H2O 0.24 in H2O Available static pressure 0.36 in H2O 0.36 -in H2O Supply / return available pressure 0.260 / 0.100 in H2O 0.260 / 0.100 in H2O Lowestfriction rate 0.099 in/100ft 0.099 in/10011 Actual airflow 920 dim 920 cfim Total effective length (TEL) 363ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BKH c 280 4 15 0.146 4.0 Ox 0 VIFx 23.0 155.0 st2 BATH 1 h 644 31 16 0.101 4.0 Ox 0 VIFx 37.3 220.0 st3 BEDROOM2 h 3229 158 110 0.099 7.0 Ox0 VIFx 42.8 220.0 st3 BEDROOMS c 2279 81 118 0.099 6.0 Ox0 VIFx 42.4 220.0 st3 KITCHEN c 3791 108 196 0.233 8.0 Ox 0 VIFx 6.9 105.0 LIVINGROOM h 2189 107 93 0.141 6.0 Ox 0 VIFx 19.2 165.0 st1 LIVING ROOM -A h 2189 107 93 0.138 6.0 Ox 0 VIFx 23.0 165.0 st1 LIVING ROOM-B h 2189 107 93 0.131 6.0 Ox 0 VIFx 29:5: 170.0 st1 Laundry c 1149 58 60 0.133 4.0 Ox 0 VIFX 26.5 170.0 st2 Master Bed h 3261 159 - 127 0.100 7.0 OX 0 VIFx 40.5 220.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (afm) (cfm) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 321 279 0.131 588 10.0 0 x 0 VinlFlx st3 PeakAVF 430 . 371 0.099 547 - 12.0 0 x 0 VinlFlx st2 st2 PeakAVF 492 445 0.099 626 12.0 0 x 0 VinlFlx � * wrightso, �.o-,n,.m,ft,.�, Right-Suite®Universal 2021 21.0.03 RSU16998 ...ity PSLILOT;66 Notlem Drive Fort PierceFL_ rup Calc= MJ8 faces: N 2021-Feb-1215:58:55 Page 1 Return Branch Detail Table Name Grille Size (in) Htg (cfm) CIg (cfm) TEL M Design FR Veloc (fpm) Diam (in) H x W .. (in) Stud/Joist Opening (in) Duct Matl Trunk rb4 Ox 0 920 920 100.5 0.099 659 16.0 Ox 0 VIFx wrightsoft"' 2021-Feb-1215:58:55 ^' eM •,M.hnb�.,, .„•._ti, Right -Suite® Universal 202121.0.03RSU16998 Paget ACCA ...ity PSL\LOT 5-6 Nollem Drive Fort PierceFL_.rup Calc= MJ8 faces: N