HomeMy WebLinkAboutBuilding PlansSTRUCTURAL DESIGN STATEMENT
I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE
PLANS AND SPECIFICATIONS HAVE BEEN DESIGNED TO COMPLY WITH
THE APPLICABLE STRUCTURAL PORTIONS OF THE BUILDING CODES.
I ALSO CERTIFY THAT THE STRUCTURAL COMPONENTS, SYSTEMS, &
RELATED ELEMENTS PROVIDE ADEQUATE RESISTANCE TO WIND
LOADS AND FORCES SPECIFIED BY THE CODES LISTED BELOW.
DESIGN PARAMETERS & ASSUMPTIONS
CODE EDITION:
■ FLORIDA BUILDING CODE 2020, 7TH EDITION
■ FLORIDA EXISTING BUILDING CODE 2020, 7TH EDITION
■ ASCE 7 (EXPOSURE CONDITION): C
CONSTRUCTION TYPE: VB
OCCUPANCY CLASSIFICATION: R-3
ALTERATION LEVEL: REPAIR
BUILDING DESIGNED AS:
❑ PARTIALLY ENCLOSED
■ ENCLOSED
❑ OPEN
❑ TESTED (WIND TUNNEL)
BUILDING HEIGHT:
■ S 60 FT. ASCE 7.
❑>60FT. MUST USE ASCE 7.
MEAN ROOF HEIGHT: <1
FOR LOW RISE BUILDING WITH SLOPED ROOFS.
RISK FACTOR: I
DETERMINED BUILDING USE/ OCCUPANCY, REFER 1
TABLE 1.5-1.
INTERNAL PRESSURE COEFFICIENT: +/
ENCLOSED BUILDING.
BASIC WIND VELOCITY PRESSURES:
APPROPRIATE POSITIVE/ NEGATIVE PRESSURE COEI
BEEN APPLIED TO MAIN WIND FORCE RESISTING SY;
BUILDING ENVELOPE COMPONENTS AND CLADDIt
APPLICABLE:
WIND SPEED (3 SEC.GUST): 16
BASIC VELOCITY PRESSURE: 31
NOTE:ACTUAL DESIGN PRESSURES FOR ALL EXTEI
WINDOWS, DOORS, GARAGE DOORS AND SIMI
ELEMENTS ARE INDICATED ON CONSTRUCTION I
e
,
NOTE: -CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS. IF CONDITIONS VARY- SIGNIFICANTLY
FROM THIS PLAN CONTRACTOR IS TO VERIFY
THIS OFFICE FOR FURTHER EVALUATION.
NOTE: CONTRACTOR TO NOTIFY ANY
ADDITIONAL STRUCTURAL DAMAGE NOT LISTED
IN THESE DRAWINGS OR INSPECTION REPORT.
a
STRUCTURAL DAMAGE AREA
NON STRUCTURAL DAMAGE
EXISTING 1"0 REMAIN. (NO DAMAGE)
EX ST NIS FLOOR PLAN
SCALE 1 /4" = 1'-0"
GENERAL NOTES
1. DO NOT SCALE THESE DRAWINGS.
WRITTEN DIMENSIONS TAKE PRECEDENCE
OVER SCALED DIMENSIONS. THE
CONTRACTOR SHALL REVIEW THESE
DRAWINGS IN THEIR ENTIRETY BEFORE
COMMENCING CONSTRUCTION AND
SHALL ACCEPT FULL RESPONSIBILITY FOR
ANY ERRORS OR OMISSIONS NOT
REPORTED IMMEDIATELY IN WRITING TO
THE WHOLE HOUSE ENGINEERING, LLC.
BACK CHARGES WILL NOT BE ACCEPTED.
2. THE GENERAL CONTRACTOR SHALL VERIFY
THE BUILDING POSITION WITHIN THE
SETBACK, LINES PRIOR TO COMMENCING
CONSTRUCTION. _
3. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO BE FAMILIARIZED WITH
ALL EXISTING CONDITIONS AS THEY ARE
NOT NECESSARILY SHOWN QN THESE
DRAWINGS.'
4. GENERAL CONTRACTOR SHALL BE
RESPONSIBLE FOR VERIFYING LOCATIONS
OF ALL FLOOR, ROOF, AND WALL
OPENINGS AND PENETRATIONS.
5. IT IS THE CONTRACTORS SOLE
RESPONSIBILITY TO COORDINATE THE
WORK OF ALL TRADES, DETERMINE
ERECTION PROCEDURE, AND SEQUENCE
TO INSURE THE SAFETY OF THE BUILDING, ITS
COMPONENTS, AND TRADE BASE DURING
CONSTRUCTION.
6. ALL DETAILS AND SECTIONS SHOWN ON
THESE DRAWINGS ARE INTENDED TO BE
TYPICAL AND SHALL BE CONSTRUED TO
APPLY TO ANY SIMILAR CONDITION
ELSEWHERE IN THE WORK EXCEPT WHERE A
DIFFERENT DETAIL AND OR SECTION IS
SHOWN.
7. BUILDER IS RESPONSIBLE FOR ADEQUATE
BRACING OF STRUCTURAL OR
NON-STRUCTURAL MEMBERS DURING
CONSTRUCTION.
8. IT IS THE GENERAL CONTRACTORS
RESPONSIBILITY TO PROVIDE ALL
NECESSARY SHOP DRAWINGS, WINDOWS,
DOORS, ETC. TO WHOLE HOUSE
ENGINEERING, LLC FOR REVIEW AND,
APPROVAL.
9. ALL WINDOWS AND DOORS SHALL BE
CAULKED AND WEATHER STRIFPED.
10.THESE DOCUMENTS, AS INSTRUMENTS OF
SERVICE, ARE THE PROPERTY OF WHOLE
HOUSE ENGINEERING, LLC„ AND SHALL
NOT BE USED OR REPRODUCED WITHOUT
THE EXPRESS WRITTEN CONSENT OF WHOLE
HOUSE ENGINEERING, LLC.
11. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR OBTAINING ALL REQUIRED BUILDING
AND TRADE PERMITS AND FOR THEIR
RESPECTIVE COSTS.
12. THESE DRAWINGS ARE DIAGRAMMATICAL
AND ARE INTENDED TO SHOW DESIGN
INTENT ONLY. THEY DO NOT SHOW EVERY
MINOR DETAIL OF CONSTRUCTION. ALL
TRADES ARE RESPONSIBLE FOR FURNISHING
COMPLETE BUILDING SYSTEMS AND ALL
ITEMS THAT WOULD NORMALLY BE
CONSIDERED INCIDENTAL TO THEIR
INSTALLATION.
FLOOR PLAN NOTES
1. SAFETY GLAZING. ALL GLAZING IN SLIDING
AND SWINGING DOORS, INCLUDING
SHOWER AND TUB ENCLOSURES, TO BE
SAFETY GLAZED AS PER FBC 2406.4 &
R308.4. ALL GLAZING IN ANY HAZARDOUS
LOCATION OF A BUILDING WITH SILL LESS
THAN 60" A.F.F. SHALL BE SAFETY GLAZED
AS PER FBC 2406.4 (5) & R308.4 (2) ALL
GLAZING WITHIN 24" OF AND PARALLEL TO
A DOOR SHALL BE TEMPERED.
2. FIRE BLOCKING. PROVIDE FIRE BLOCKING
AT ALL CONCEALED SPACES.
3. SHUTTERS. STORM SHUTTERS WITH AN
ACCEPTED PRODUCT APPROVAL SHALL BE
PROVIDED AT ALL OPENINGS EXCEPT
THOSE PROTECTED BY APPROVED IMPACT
RESISTANT DOORS AND WINDOWS.
4. ROUGH OPENINGS. VERIFY ALL ROUGH
OPENING AND MASONRY OPENING SIZES
WITH MANUFACTURER'S PRODUCT
SPECIFICATIONS.
5. EGRESS WINDOWS. EGRESS WINDOWS
SHALL BE OPERABLE FROM THE INSIDE
WITHOUT THE USE OF TOOLS. EGRESS
WINDOWS SHALL HAVE A MINIMUM NET
OPENING OF 24" HIGH, 20" WIDE, AND
MIN. NET AREA OF 5.7 S.F. FOR 2ND FLOOR
WINDOWS AND 5.0 S.F. FOR 1 ST FLOOR
WINDOWS. THE SILL HEIGHT SHALL NOT BE
MORE THAN 44" ABOVE THE FLOOR, LATCH
AT 54" A.F.F. MAX.. OPERABLE WINDOWS
WITH A SILL PORTION OF THE OPENING
LOCATED LESS THAN 24" A.F.F. AND MORE
THAN 72" ABOVE FINISHED GRADE SHALL
INCLUDE A WINDOW OPENING CONTROL
DEVICE THAT COMPLIES WITH SECTIONS
R312.2.1 AND R312.2.2 OF THE F.R.C.
6. BATHTUB AND SHOWER SPACES. BATHTUB
& SHOWER FLOORS & WALLS ABOVE BATH
TUBS WITH INSTALLED SHOWER HEADS & IN
SHOWER COMPARTMENTS SHALL BE
FINISHED WITH AN IMPERVIOUS,
NON -CORROSIVE, NON -ABSORBENT &
WATERPROOF MATERIAL. MOISTURE
RESISTANT BACKING BOARD REQUIRED
UNDER IMPERVIOUS WALL AREAS IN BATH
TUB & SHOWER SPACES. SUCH WALL
SURFACES SHALL EXTEND NOT LESS THAN
6-0" ABOVE THE ROOM FLOOR LEVEL.
7. BACKING FOR CABINETS. PROVIDE 2X4
MINIMUM HORIZONTAL BACKING IN
KITCHEN W/ TOP @ 35" A.F.F. & TOP @ V-0"
A.F.F. & IN BATHROOM VANITY AREAS W/
TOP @ 30" A.F.F. OR AS REQUIRED FOR
CABINET ATTACHMENT.
8. WOOD FRAME WALLS. WOOD FRAME
WALLS AND HEADERS ARE DESIGNED
USING RATIONAL ANALYSIS.
FRAMING PLAN NOTES
1. THE ROOF FRAMING PLAN SHOWS
LOCATION & DIRECTION OF ALL ROOF
MEMBERS (TRUSSES AND GIRDERS). FOR
INDIVIDUAL TRUSSES, SEE LAYOUT &
ENGINEERING SHEETS BY TRUSS
MANUFACTURER.
2. ALL CONCRETE BEAMS TO BE A MINIMUM
OF 8" X 12" WITH (2) #5 BARS TOP & (2) #5
BARS BOTTOM UNLESS NOTED OTHERWISE
ON PLANS.
3. AT ALL POURED CONCRETE BEAM AND
BOND BEAM INTERSECTIONS, EXTEND
BOND BEAM STEEL 30" INTO POURED
BEAMS.
4. ANY OF THE SPECIFICALLY NOTED BEAMS
MAY BE BUILT UP TO 1"SMALLER OR 2"
LARGER WITHOUT ANY CHANGE OF
REQUIRED STEEL.
5. STIRRUPS NOT REQUIRED UNLESS NOTED
OTHERWISE.
6. ALL HEADERS & WOOD BEAMS TO BE (2)
2"X12" HEM -FIR #2 UNLESS NOTED
OTHERWISE ON PLAN.
7. #2 S.Y.P. MAY BE SUBSTITUTED ANYWHERE
HEM -FIR IS SPECIFIED.
8. PROVIDE FILLED CELLS @ MINIMUM 6"
ABOVE & 6' BELOW ALL EXPANSION BOLT
LOCATIONS IN C.B.S. WALLS (TYPICAL).
9. SPACE FLOOR TRUSSES ACCORDINGLY TO
AVOID CONFLICT W/ PLUMBING FIXTURE
DRAINS ABOVE. COORDINATE W/
ARCHITECTURAL PLANS.
10.ANY WOOD IN CONTACT WITH CONCRETE
SHALL BE PRESSURE TREATED.
lk of ." b 2?-2,
REVIEWED FOR
CODE COMPLIANCE
�•T. LUCIE COUNTY
ROCS 14.
`1C6�zk
FILE COPY
PREPARED FOR
BILL- AND MARLENE
STEWART
ENGINEERING
WHOLE HOUSE ENGINEERING
4451 ST. LUCIE BLVD, SUITE 201
FORT PIERCE, FL 34946
CONTACT: 772.409.1003
ENGINEERINGCdWHENGINEERING.NET
DRAWING NOTICE
THESE DRAWINGS AND DOCUMENTS
ARE CONFIDENTIAL AND ARE THE
SOLE PROPERTY OF WHOLE HOUSE
ENGINEERING, LLC, AND MAY NOT BE
REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE
EXPRESS WRITTEN CONSENT ❑F
WHOLE HOUSE ENGINEERING, LLC.
WARNING. DO NOT SCALE DRAWINGS.
PLEASE CONTACT DESIGNER WITH
ANY QUESTIONS REGARDING
DIMENSIONS, ARCHITECTURAL
SYMBOLS CONTAINED WITHIN THESE
DOCUMENTS ARE FOR GRAPHIC
PURPOSES ONLY, SIZE AND
LOCATION MAY VARY IN ORDER TO
MEET THE MAN'UFACTURER'S�
S P E C_I_ F T_C H_T I❑ N S_
RYAN M BAYS P.E.
FL #91231
,A# U ,
i
��t,LN,q•.
No.
STATE
OR1
Fs ..NA.
REVISION
DATE
BY
REV
REPAIR PERMIT
07/02/2021
RB
PROJECT NUMBER, NAME & ADDRESS:
WHE 10293
STEWART RESIDENCE
n n f l T 1 1 A d f> I I A I I/ I I A 1 /� m l 1
LUL I UIVIL)LIIN I\LIINl. KL),
FORT PIERCE,
FL 34982
DRAWN BY:
RB
SHEET TITLE:
EXISTING FLOOR PLAN
SHEET NO.:
S-1.0
EXTERIOR DOOR & WINDOW SCHEDULE
R.O. (WIDTH X HT.)
(FT -INCHES)
MANUFACTURER
DESIGN PRESSURES
PRODUCT APPROVAL
NUMBER
EXPIRATION
OPENING
DESIGN
PRESSURES
PRODUCT RATED DESIGN
PRESSURES
SYM.
ITEM
LOCATION
Pos.
NEG.
O
33SH WINDOW
DEN
3' - 2" X 3' - 2 7/8"
LAWSON
SEE EILEV'S
+80.0
80.0
29876.1
e
STRUCTURAL DAM
AGE AREA MSTC40 STRAP ATEA H END O
HEADER FLUSH WITH TOP OF TO
PLATE, HEADER, & 1ST SUPPORTIN
NON STRUCTURAL DAMAGE STUD (FILL 9 HOLES IN STUD MINIMU
FILL ALL NAIL HOLE
EXISTING TO REMAIN. (NO DAMAGE)
II
I
' TITEN HD ANCHOR W/ 2"
p WASHERS, 4" MIN. EMBEDMENT @
C TR U CTU R A L , I ,� RCA R PLAN 24" O.C. MAX.
1 SCALE 1 /4" 1 ,:7 0
P.T. 2X4 5
BOTTOM PLAT
G
M,
S)
P
E
F
WOOD HEADER -�
P
STUD NAILED TO JACK NJ/
12d NAILS @ 10 O.C.
ST.
U
i
TRUSS
CONNECTORS. SEE
PLAN.
2X4 SP STUDS @ 16"
PROJECT NUMBER, NAME & ADDRESS:
O.C. MAX.
OR
2X6 SP STUDS @ 24"
O.C. MAX.
W H E 10293
STEWART RESIDENCE
EWZU k-uh
202 TUMBLIN KLING RD,
COMPLIANCE
CIE COUNTY
FORT PIERCE,
BOCC
FL 34982
H8 CONNECTOR AT
EACH STUD.
DRAWN BY:
8„ MAX
I
�
RB
SHEET TITLE:
n
TYP CAC BCARU �(COPY
RRA�
STRUCTURA
L REPAIRCALL
PLAN
SCALE 1 2
NOTE: .CONTRACTOR. TO VERIFY ALL EXISTING 10
CONDITIONS. IF CONDITIONS VARY SIGNIFICANTLY -
SHEET NO.:
FROM THIS PLAN 'CONTRACTOR IS TO VERIFY
THIS OFFICE FOR FURTHER EVALUATION. -
S-2.0
NOTE: CONTRACTOR TO NOTIFY ANY
ADDITIONAL STRUCTURAL DAMAGE NOT LISTED
IN THESE DRAWINGS OR INSPECTION REPORT.
ELECTRICAL K Y
PREPARED FOR:
BILL AND MARLENE
STEWART
GENERAL ELECTRICAL NOTES
1, ALL WORK SHALL BE DONE IN. ACCORDANCE WITH BOTH LOCAL AND
NATIONAL ELECTRICAL CODES.
2. ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL PLAN, RISER
DIAGRAM, AND LOADS, AND NOTIFY THE GENERAL CONTRACTOR OF ANY
ERRORS OR DESCREPANCIES PRIOR TO INSTALLATION,'
3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO
MAKE CERTAIN THAT .ALL AIR-CONDITIONING POWER AND CONTROL WIRING
AND CONDUITS ARE IN THE BID.
4, ELECTRICAL CONTRACTOR IS TO COORDINATE ALLSERVICE REQUIREMENTS
WITH THE POWER COMPANY BEFORE BIDDING TO BE CERTAIN THAT ALL
WORK NECESSARYTO MEET POWER COMPANY 'SPECIFICATIONS IS IN THE
BID,
5. THE ELECTRICAL CONTRACTOR IS TO SIZE MOST BRANCH CIRCUITSj A
MAXIMUM VOLTAGE DROP OF 3% IS PERMITTED.
6. SMOKE DETEeCTORS SHALL BE DIRECT' WIRED 120V U.L. 217 APPROVED
TYPE WITH AUDIBLE ALARM INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS AND LISTING, CARBON MONOXIDE
DETECTOR(S) TO COMPLY W/ UL 42034-96.
7. ALL APPLIANCE / ELECTRICAL EQUIPMENT WILL BE PROTECTED AT NAME
PLATE RATING AS PER NEC 110.3 & 110,21.
8, ALL ELECTRICAL CIRCUITS THAT SUPPLY THE FAMILY ROOM, DINING ROOM,
LIVING ROOM, STUDY; HALLWAYS, BEDROOMS, CLOSETS, AND FOYER SHALL
BE ARC -FAULT PROTECTED,
9 ALL 125 VOLT 15 & 20 AMP RECEPTACLES INSTALLED IN DWELLING UNITS
SHALL BE TAMPER RESISTANT AS PER NEC 406.11.
10 INTERSYSTEM BONDING REQUIRED AND SHALL COMPLY WITH SECTION
250,94, 2008 NEC.
11. GARAGE DOOR OPENER ' TO BE GFI PROTECTED.
12. ALL EQUIPMENT INSTALLED ❑UTSIDE OR EXPOSED TO WEATHER SHALL BE
NEMA TYPE 3R.
13. ALL CONDUCTORS ARE TO BE COPPER, TYPE THHN, UNLESS NOTED
❑THERWISE,
14. SWITCHES SHALL BE OF, STANDARD GRADE OF SILENT TYPE,
15. RECEPTACLES SHALL BE 15A AND 120V OF THE GROUND TYPE,
16. LIGHTING FIXTURES SHALL BE SELECTED BY THE OWNER. 50"/. OF THE
LAMPS SHALL BE HIGH EFFICACY TYPE.
17, ALL DEVICES SHALL BE SMOOTH TYPE, IVORY COLOR, UNLESS OTHERWISE
SPECIFIED,
i18. ALL 120V I —PHASE 15A AND 20A BATHROOM, AND EXTERIOR RECEPTACLES
SHALL HAVE GROUND FAULT INTERRUPTER (GFI) PROTECTION WITH
EXTERIOR RECEPTACLES OF THE WATERPROOF TYPE ELECTRICAL
CONTRACTOR MAY INSTALL INDIVIDUAL (GFI) IN LIEU OF (GFI) BREAKER
WITH SEPARATE CIRCUIT,
19 ARC -FAULT CIRCUIT INTERRUPTER PROTECTION: ALL 120V, SINGLE PHASE, 15 AND 20 AMP
BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED OR DEVICES IN DWELLING UNIT
KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
SUN ROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR
ROOMS OR AREAS SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN THE NEC
2011 210.12 (A)(1) THROUGH (6)
20. INSTALLATION HEIGHTS ABOVE FINISH FLOOR UNLESS ❑THERWISE NOTED:
45" TO CENTER WALL HUNG TELEPHONE,
12" TO CENTER TELEPHONE JACKS.
46" TO CENTER OF LIGHT SWITCHES.
16" TOCENTEROF RECEPTACLES
46" TO CENTER KITCHEN RECEPTACLES OVER COUNTERS,
42" TO CENTER BATH RECEPTACLES.
12" TO CENTER' TELEVISION JACKS,
21, BRANCH CIRCUITS SHALL BE IN THIN WALL CONDUIT OR APPROVED
ROMEX.
22. ALL FAN' VENTING AND ROOF PENETRATIONS SHALL BE BY MECHANICAL
CONTRACTOR.
23, EXHAUST FANS IN BATHROOMS (IF USED) SHALL BE RATED AT 1 CFM/SF OF
VENTILATED FLOOR AREA.
NOTE: CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS. IF CONDITIONS VARY SIGNIFICANTLY
FROM THIS PLAN CONTRACTOR IS TO VERIFY
THIS OFFICE FOR FURTHER EVALUATION.
NOTE: ELECTRICAL WORK IS TO ONLY TO
RESTORE PRE —DAMAGED STATE. NO ADDITIONAL
ELECTRIC LOAD TO SERVICE.
STRUCTURAL DAMAGE AREA
NON STRUCTURAL DAMAGE
EXISTING TO REMAIN. (NO DAMAGE)
e
ECCTR CAL P1AN
/ SCALE : 1 /4" — 1'-0"
,.DUPLEX. OUTLET
=1�SWITCHED. DUPLEX OUTLET
GR nt� DUPLEX .O,�TLET.( 'Ground Fault Circuit Interrupter 1
AF1.=9:-DUPLEX--OUTLET ( Arc Fault Circuit Interrupter
'PUSH .BUTTON SWITCH
0 >3. `a/AY SWI`TCH
4. WAY SWITCH
Li-GHT FIXTURE
i
} RECESSED LIGHT FIXTURE
P
RECESSED LIGHT FIXTURE (VAPOR PROOF;
CEILING FAN
/ TELEPHONE
■ TELEVISION
EXHAUST FAN
220' VOLT OUTLET
FLOOD LIGHT ( MOTION DETECTOP TYPE ;
)S.D SMOKE DETECTOR:
OC.M.A CARBON` MONOXIDE ALARM
REVIEWED FOR
ODE COMPLIANCE
17 LUCIE CCI **MT
FILE COPY
WHOLE HOUSE ENGINEERING
4451 ST. LUCIE BLVD, SUITE 201
FORT PIERCE, FL 34946
CONTACT: 772.409.1003
ENG I NEERING@ W H ENGI NEERI NG.NET
DRAWING NOTICE
THESE DRAWINGS AND DOCUMENTS
ARE CONFIDENTIAL AND ARE THE
SOLE PROPERTY OF WHOLE HOUSE
ENGINEERING, LLC, AND MAY NOT BE
REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE
EXPRESS WRITTEN CONSENT OF
WHOLE HOUSE ENGINEERING, LLC
WARNING: D❑ NOT SCALE DRAWINGS.
PLEASE CONTACT DESIGNER WITH
ANY QUESTIONS REGARDING
DIMENSIONS. ARCHITECTURAL
SYMBOLS CONTAINED WITHIN THESE
DOCUMENTS ARE FOR GRAPHIC
PURPOSES ONLY. SIZE AND
LOCATION MAY VARY IN ORDER TO
MEET THE MANUFACTURER'S
RYAN M BAYS P.E.
FL #91231
,� , 4iill prtrr
aN M: 841,-,,
No.'.I
< : T
tC
'F/0RIOPrJN I
�rr/rltll i 1111,11��� i
REVISION DATE BY REV
REPAIR PERMIT 07/02/2021 RB -
PROJECT NUMBER, NAME & ADDRESS:
W H E 10293
STEWART RESIDENCE
202 TUMBLIN KLING RD,
FORT PIERCE,
FL 34982
DRAWN BY:
RB
SHEET TITLE:
ELECTRICAL PLAN
SHEET NO.:
NOTE: CONTRACTOR TO NOTIFY ANY E-1.0
ADDITIONAL STRUCTURAL DAMAGE NOT LISTED
IN THESE DRAWINGS OR INSPECTION REPORT.