HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MW-16
Builder Name: GHO BUILDERS
Street: 3605 GROVE CT
Permit.Office: ST. LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1819.3 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Ext Insul, Exterior
R=4.1 1617.10 ft2
b. Frame - Wood, Adjacent
R=11.0 202.22 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
11. Ceiling Types (1812.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=40.0 1812.00 ft2
6. Conditioned floor area above grade (ft2) 1812
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(255.2 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
R ft2
6 482
a. U-Factor: Dbl, U=0.62 255.17 ft2
SHGC: SHGC=0.26
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
38.5 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 6.750 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.260
a. Electric Strip Heat
24.8 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1812.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1812.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.141 Total Proposed Modified Loads: 53.38
PASS
Total Baseline Loads: 58.99
I hereby certify that the plans and specifications covered by
Review of the plans and
ST,gT�
this calculation are in compliance with the Florida Energy
specifications covered by this
OFZKE
y a Off,
Code.
calculation indicates compliance
with the Florida Energy Code.
�k� , ,,:�a�
��;, O
ti rrrrrr'�
,' ;:�',;,,•,
""''' ' to
PREPARED BY:
Before construction is completed
r�
DATE: 05/26/2021
this building will be inspected for
compliance with Section 553.908
@ fl
* n
hereby certify that this building, as designed, is in compliance
the Florida Energy Code.
Florida Statutes.
G'OD
with
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer_ that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
5/26/2021 4:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Soft�rd'�
Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-16
User
1
GHO BUILDERS
ST. LUCIE COUNTY
Detached
New (From Plans)
Bedrooms: 3
Conditioned Area: 1812
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 3605 GROVE CT
County: St. Lucie
City, State, Zip: FORT PIERCE,
FL, 34951
CLIMATE
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
1812 17757.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1812 17757.6 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 186.8 ft
1812 ft2 ---- 0 0 1
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Hip
Flat tile/slate 2026 ft2 0 ft2 Medium
N 0.4 N 0.9 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RIBS IRCC
1
Full attic
Vented 150 1812 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 40 Blown
1812 ft2 0.1 Wood
5/26/2021 4:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
Space RA/al, le Ft In Ft
In Area
R-Xallle
Ernctonn Ahqnr
rrafie%
1
N
Exterior Concrete Block - Ext Insul Main
4.1 58 2 9
4 542.9 ft2
0
0 0.3
0
2
E
Exterior Concrete Block - Ext Insul Main
4.1 18 6 9
4 172.7 ft2
0
0 0.3
0
3
S
Exterior Concrete Block - Ext Insul Main
4.1 53 10 9
4 502.4 ft2
0
0 0.3
0
4
W
Exterior Concrete Block - Ext Insul Main
4.1 37 5 10
8 399.1 ft2
0
0 0.3
0
5
-
Garage Frame - Wood Main
11 21 8 9
4 202.2 ft2
0
0.25 0.3
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
n 1 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft2 2 ft 0 in
1 ft 0 in
None
None
2
n 1 Metal Double (Clear) Yes
0.62 0.26 N
15.0 ft2 2 ft 0 in
1 ft 0 in
None
None
3
e 2 Metal Double (Clear) Yes
0.62 0.26 N
26.0 ft2 8 ft 0 in
1 ft 0 in
None
None
4
s 3 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft2 2 ft 0 in
1 ft 0 in
None
None
5
s 3 Metal Double (Clear) Yes
0.62 0.26 N
6.5 ft2 2 ft 0 in
1 ft 0 in
None
None
6
s 3 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft2 2 ft 0 in
1 ft 0 in
None
None
7
w 4 Metal Double (Clear) Yes
0.62 0.26 N
30.0 ft2 2 ft 0 in
1 ft 0 in
None
None
8
w 4 Metal Double (Clear) Yes
0.62 0.26 N
36.0 ft2 10 ft 0 in
2 ft 4 in
None
None
9
W 4 Metal Double (Clear) Yes
0.62 0.26 N
96.0 ft2 10 ft 0 in
2 ft 4 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
583 ft2 583 ft2
64 ft
9.3 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000436
2071.7 113.66 213.39 .137
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1
24.82 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/ Split
Singl SEER: 16 38.5 kBtu/hr
cfm
0.7 1
sys#1
5/26/2021 4:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
-- Supply --
V
--- Return ---
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 482 ft2
Attic
218 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[[ jJan Feb
Heatin[X] Jan Feb
Mar
Mar
Apr
E Apr f
Ma X Jun X Jul
May 4 Jun Jul
X Aug
Aug
Se
SeP
Oct
Oct
Nov
Nov
HX
Dec
Dec
H
Ventin [[ ] Jan Feb
X Mar
[Xl A r [
Ma [ Jun Jul
Au
Se
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
5/26/2021 4:06 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 90
The lower the EnergyPerformance Index, the more efficient the home.
3605 GROVE CT, FORT PIERCE, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
2. Single family or multiple family
Detached
a. Concrete Block - Ext Insul, Exterior
b. Frame - Wood, Adjacent
3. Number of units, if multiple family
1
c. N/A
4. Number of Bedrooms
3
d. N/A
11. Ceiling Type and insulation level
5. Is this a worst case?
No
a. Under Attic (Vented)
6. Conditioned floor area (ft2)
1812
b. N/A
7. Windows- Description
Area
c. N/A
a. U-Factor: Dbl, U=0.62
255.17 ft2
Ducts, location & insulation level
a.
a. Sup: Attic, Ret: Attic, AH: Main
SHGC: SHGC=0.26
b. U-Factor: N/A
ft2
SHGC:
13. Cooling systems
c. U-Factor: N/A
ft2
a. Central Unit
SHGC:
d. U-Factor: N/A
ft2
14. Heating systems
SHGC:
a. Electric Strip Heat
Area Weighted Average Overhang Depth:
6.750 ft.
Area Weighted Average SHGC:
0.260
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2
a. Electric
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1812.00 ft2
Credits (Performance method)
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above ene gy saving features which will be installed (or exceeded)
in this home before final inspection.0 Otherwise, a new EPL Display Card will be completed
based on installed Code compliant tpatures.
Builder Signature:
Address of New
Insulation
Area
R=4.1
1617.10 ft2
R=11.0
202.22 ft2
R=
ft2
R=
ft2
Insulation
Area
R=40.0
1812.00 ft2
R=
ft2
R=
ft2
R ft2
6 482
kBtu/hr Efficiency
38.5 SEER:16.00
kBtu/hr Efficiency
24.8 COP:1.00
Cap: 50 gallons
EF: 0.94
Pstat
i �$E S
y0
Date:
City/FL Zip: pi-`- .
Cps WE flt4
3�1gs I
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/26/2021 4:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction:
Permit #:
Jobbinfor mation :v .a .� e rn��R
Builder: GHO BUILDERS Community: Lot: NA
Address: 3605 GROVE CT
City: FORT PIERCE State: FL Zip: 34951
Air Leakage Test: Results Passing results must meet either the Performance Prescriptive, or ERI Method .
O PRESCRIPTIYE.METHOD The !%u)Itlingor dwelling unitshall be tested anti:verified`as haying an air eakage,rate°of'not,exoeedng 7. air 'w
changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 `and 2.
O PERFORMANCE or ERI METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACH(50) value as shown on, F,or R405 2020 Performance or R4p6 2020:(ERI , section labeled as infilt[ationsub-section ACH50.
o_. ,-
ACFI(50)'specifred on Fdtmn R405-2020-Energy 6aic (Penbrmance) or R406-2020`(�R1): 7.000
x 60 17758 = Method for calculating building volume:
CFM(50) Building Volume ACH(50)
O Retrieved from architectural plans
1-1 PASS • Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation 0 Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(0, (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
,s y .:.
A *a, ,crt i `� n h k v mia 4 . 5pw
Tes in Co,'mpany .
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
5/26/2021 4:06:38 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
.�- wrightsoft® Load Short Form
Entire House
For: MW-16
3605 GROVE CT, FORT PIERCE, FL 34951
Job:
Data: May 26, 2021
By.
Htg Clg Infiltration
Outside db (OF) 41 90 Method Simplified
Inside db (°F) 70 72 Construction quality Average
Design TD (°F) 29 18 Fireplaces 0
Daily range - L
Inside humidity (%) 30 52
Moisture difference (grAb) 2 61
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Airflowfactor
Static pressure
Space thermostat
100 EFF
7.3
kW
24817
Btuh
0
OF
0
cfm
0
cfmBtuh
0.50
in H2O
COOLING EQUIPMENT
Make
Lennox
Trade
LENNOX
Cond
ML14XC1-041-230X*
Coil
CBA27UHE-048-230*++TDR
AHRI ref
10259425
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual airflow
Air flow factor
Static pressure
Load sensible heat ratio
13.0 EER,16 SEER
26950
Btuh
11550
Btuh
38500
Btuh
1090
crm
0.037
cknBtuh
0.50
in H2O
0.81
ROOM NAME
Area
(ftz)
Htg load
(Btuh)
Clg load
(Btuh)
HtgAVF
(r-fm)
CIgAVF
(cfm)
MASTER BATH
210
1784
1086
0
41
BED 2
191
2860
2011
0
75
LAUNDRY/MECH
82
902
1444
0
54
BATH 2
63
56
301
0
11
FOYER
91
698
633
0
24
DINING
126
3508
3435
0
128
KITCHEN
158
1812
3278
0
122
BED 3
183
3905
2820
0
105
GREAT RM
374
3605
8479
0
317
HER W IC
65
1005
545
0
20
MASTER SUITE
242
4908
5149
0
192
hAprru
1 n
n
n
n
n
Bold/dalle values have been manually overridden
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrightsoft® 2021 -May-26 14:33:21
n nmw•,o n,,. o.in. .,imp , Right -Sate® Unversal 202121.0.05 RSU29964 Page
...ers%AVserlDoamerts\WrightsoftHVAC\MW-16.np Calc=MJ8 Fror3Doorfaces: E
Entire House
1804
25043
29181
0
1090
Other equip loads
0
0
Equip. @ 0.95 RSM
27838
Latent cooling
6866
TP1TAl Q
IOnA
7GnA4
4A7nA
A
4nnn
VVT LJVTJ J VT V I VZJV
Boldldalic values have been manually overridden
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
wrightsoft- 2021-May-2614:3321
Z&^� AIII* 1O11111*mm•w•r� l Right-Sute®Uriversal202121.0.05RSU29964 Paget
...ersWryUserlDoasnerts%W6ghtsoftWACWIW-16.np Calc=MJ8 FrordDoorfaces: E
- +- wrightsoft, Project Summary
Entire House
For: MW-16
3605 GROVE CT, FORT PIERCE, FL 34951
Notes:
Weather: St Lucie Co Infl, FL, US
Winter Design Conditions
Outside db 41 OF
Inside db 70 OF
Design TD 29 OF
Heating Summary
Structure
23363
Btuh
Ducts
1681
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipmentload
25043
Btuh
Infiltration
Method
Simplified
Construction quality
Average
Fireplaces
0
Heatingg Cooling
Area (ft2)
1804
1804
Volume (fta)
17825
17825
Airchanges/hour
0.38
0.20
Equiv AVF (cfm)
113
59
Heating Equipment
Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
100 EFF
7.3 kW
24817 Btuh
0
0 cfin
0 cfmBtuh
0.50 in H2O
Job:
Date: May26, 2021
By.
Summer Design Conditions
Outside db
90
OF
Inside db
72
OF
Design TD
18
OF
Daily range
L
Relative humidity
52
%
Moisture difference
61
grAb
Sensible Cooling Equipment Load Sizing
Structure
25990
Btuh
Ducts
3190
Btuh
Central vent (0 cim)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturers data n
Rate/swingg multipplier 0.95
Equipmentsensible load 27838 Btuh
Latent Cooling Equipment Load Sizing
Structure
5459
Btuh
Ducts
1407
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
6866
Btuh
Equipment Total Load (Sen+Lat) 34704 Btuh
Req. total capacity at 0.70 SHR 3.3 ton
Cooling Equipment Summary
Make Lennox
Trade LENNOX
Cond ML14XC1-041-230A**
Coil CBA27UHE-048-230*++TDR
AHRI ref 10259425
Efficiency 13.0 EER,16 SEER
Sensible cooling 26950
Btuh
Latentcooling 11550
Btuh
Total cooling 38500
Btuh
Actual airflow 1090
cfi71
Air flow factor 0.037
cfmBtuh
Static pressure 0.50
in H2O
Load sensible heat ratio 0.81
Bo/drdalic values have been manually overridden
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
t - =!Rntsoft- 2021-May-2614:33.22
^��•• •^ • ea �• • =•ma Right-Sute®Uriversal2021 21.0.05 RSU29964 Page 1
ersWriyUserlDownentslWdghtsoftHVACWIW-16.rup Calc=MJ8 FrortDooriaces: E
W
LO
U
7—
LLI W
>�
O
C) W_
ULo
OOf
O
�
LL-