Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-16 Builder Name: GHO BUILDERS Street: 3605 GROVE CT Permit.Office: ST. LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�1819.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 1617.10 ft2 b. Frame - Wood, Adjacent R=11.0 202.22 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 11. Ceiling Types (1812.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=40.0 1812.00 ft2 6. Conditioned floor area above grade (ft2) 1812 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(255.2 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Main R ft2 6 482 a. U-Factor: Dbl, U=0.62 255.17 ft2 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 38.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 6.750 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.260 a. Electric Strip Heat 24.8 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1812.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1812.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.141 Total Proposed Modified Loads: 53.38 PASS Total Baseline Loads: 58.99 I hereby certify that the plans and specifications covered by Review of the plans and ST,gT� this calculation are in compliance with the Florida Energy specifications covered by this OFZKE y a Off, Code. calculation indicates compliance with the Florida Energy Code. �k� , ,,:�a� ��;, O ti rrrrrr'� ,' ;:�',;,,•, ""''' ' to PREPARED BY: Before construction is completed r� DATE: 05/26/2021 this building will be inspected for compliance with Section 553.908 @ fl * n hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. G'OD with WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer_ that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 5/26/2021 4:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Soft�rd'� Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-16 User 1 GHO BUILDERS ST. LUCIE COUNTY Detached New (From Plans) Bedrooms: 3 Conditioned Area: 1812 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 3605 GROVE CT County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 1812 17757.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1812 17757.6 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 186.8 ft 1812 ft2 ---- 0 0 1 ROOF # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 2026 ft2 0 ft2 Medium N 0.4 N 0.9 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RIBS IRCC 1 Full attic Vented 150 1812 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 1812 ft2 0.1 Wood 5/26/2021 4:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space RA/al, le Ft In Ft In Area R-Xallle Ernctonn Ahqnr rrafie% 1 N Exterior Concrete Block - Ext Insul Main 4.1 58 2 9 4 542.9 ft2 0 0 0.3 0 2 E Exterior Concrete Block - Ext Insul Main 4.1 18 6 9 4 172.7 ft2 0 0 0.3 0 3 S Exterior Concrete Block - Ext Insul Main 4.1 53 10 9 4 502.4 ft2 0 0 0.3 0 4 W Exterior Concrete Block - Ext Insul Main 4.1 37 5 10 8 399.1 ft2 0 0 0.3 0 5 - Garage Frame - Wood Main 11 21 8 9 4 202.2 ft2 0 0.25 0.3 0 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 2 ft 0 in 1 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 15.0 ft2 2 ft 0 in 1 ft 0 in None None 3 e 2 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft2 8 ft 0 in 1 ft 0 in None None 4 s 3 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 2 ft 0 in 1 ft 0 in None None 5 s 3 Metal Double (Clear) Yes 0.62 0.26 N 6.5 ft2 2 ft 0 in 1 ft 0 in None None 6 s 3 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 2 ft 0 in 1 ft 0 in None None 7 w 4 Metal Double (Clear) Yes 0.62 0.26 N 30.0 ft2 2 ft 0 in 1 ft 0 in None None 8 w 4 Metal Double (Clear) Yes 0.62 0.26 N 36.0 ft2 10 ft 0 in 2 ft 4 in None None 9 W 4 Metal Double (Clear) Yes 0.62 0.26 N 96.0 ft2 10 ft 0 in 2 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 583 ft2 583 ft2 64 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000436 2071.7 113.66 213.39 .137 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 24.82 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 38.5 kBtu/hr cfm 0.7 1 sys#1 5/26/2021 4:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply -- V --- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 482 ft2 Attic 218 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[[ jJan Feb Heatin[X] Jan Feb Mar Mar Apr E Apr f Ma X Jun X Jul May 4 Jun Jul X Aug Aug Se SeP Oct Oct Nov Nov HX Dec Dec H Ventin [[ ] Jan Feb X Mar [Xl A r [ Ma [ Jun Jul Au Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 5/26/2021 4:06 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the EnergyPerformance Index, the more efficient the home. 3605 GROVE CT, FORT PIERCE, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior b. Frame - Wood, Adjacent 3. Number of units, if multiple family 1 c. N/A 4. Number of Bedrooms 3 d. N/A 11. Ceiling Type and insulation level 5. Is this a worst case? No a. Under Attic (Vented) 6. Conditioned floor area (ft2) 1812 b. N/A 7. Windows- Description Area c. N/A a. U-Factor: Dbl, U=0.62 255.17 ft2 Ducts, location & insulation level a. a. Sup: Attic, Ret: Attic, AH: Main SHGC: SHGC=0.26 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems c. U-Factor: N/A ft2 a. Central Unit SHGC: d. U-Factor: N/A ft2 14. Heating systems SHGC: a. Electric Strip Heat Area Weighted Average Overhang Depth: 6.750 ft. Area Weighted Average SHGC: 0.260 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1812.00 ft2 Credits (Performance method) b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above ene gy saving features which will be installed (or exceeded) in this home before final inspection.0 Otherwise, a new EPL Display Card will be completed based on installed Code compliant tpatures. Builder Signature: Address of New Insulation Area R=4.1 1617.10 ft2 R=11.0 202.22 ft2 R= ft2 R= ft2 Insulation Area R=40.0 1812.00 ft2 R= ft2 R= ft2 R ft2 6 482 kBtu/hr Efficiency 38.5 SEER:16.00 kBtu/hr Efficiency 24.8 COP:1.00 Cap: 50 gallons EF: 0.94 Pstat i �$E S y0 Date: City/FL Zip: pi-`- . Cps WE flt4 3�1gs I *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/26/2021 4:06 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: Permit #: Jobbinfor mation :v .a .� e rn��R Builder: GHO BUILDERS Community: Lot: NA Address: 3605 GROVE CT City: FORT PIERCE State: FL Zip: 34951 Air Leakage Test: Results Passing results must meet either the Performance Prescriptive, or ERI Method . O PRESCRIPTIYE.METHOD The !%u)Itlingor dwelling unitshall be tested anti:verified`as haying an air eakage,rate°of'not,exoeedng 7. air 'w changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 `and 2. O PERFORMANCE or ERI METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value as shown on, F,or R405 2020 Performance or R4p6 2020:(ERI , section labeled as infilt[ationsub-section ACH50. o_. ,- ACFI(50)'specifred on Fdtmn R405-2020-Energy 6aic (Penbrmance) or R406-2020`(�R1): 7.000 x 60 17758 = Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans 1-1 PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation 0 Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(0, (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. ,s y .:. A *a, ,crt i `� n h k v mia 4 . 5pw Tes in Co,'mpany . Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 5/26/2021 4:06:38 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 .�- wrightsoft® Load Short Form Entire House For: MW-16 3605 GROVE CT, FORT PIERCE, FL 34951 Job: Data: May 26, 2021 By. Htg Clg Infiltration Outside db (OF) 41 90 Method Simplified Inside db (°F) 70 72 Construction quality Average Design TD (°F) 29 18 Fireplaces 0 Daily range - L Inside humidity (%) 30 52 Moisture difference (grAb) 2 61 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Airflowfactor Static pressure Space thermostat 100 EFF 7.3 kW 24817 Btuh 0 OF 0 cfm 0 cfmBtuh 0.50 in H2O COOLING EQUIPMENT Make Lennox Trade LENNOX Cond ML14XC1-041-230X* Coil CBA27UHE-048-230*++TDR AHRI ref 10259425 Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio 13.0 EER,16 SEER 26950 Btuh 11550 Btuh 38500 Btuh 1090 crm 0.037 cknBtuh 0.50 in H2O 0.81 ROOM NAME Area (ftz) Htg load (Btuh) Clg load (Btuh) HtgAVF (r-fm) CIgAVF (cfm) MASTER BATH 210 1784 1086 0 41 BED 2 191 2860 2011 0 75 LAUNDRY/MECH 82 902 1444 0 54 BATH 2 63 56 301 0 11 FOYER 91 698 633 0 24 DINING 126 3508 3435 0 128 KITCHEN 158 1812 3278 0 122 BED 3 183 3905 2820 0 105 GREAT RM 374 3605 8479 0 317 HER W IC 65 1005 545 0 20 MASTER SUITE 242 4908 5149 0 192 hAprru 1 n n n n n Bold/dalle values have been manually overridden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoft® 2021 -May-26 14:33:21 n nmw•,o n,,. o.in. .,imp , Right -Sate® Unversal 202121.0.05 RSU29964 Page ...ers%AVserlDoamerts\WrightsoftHVAC\MW-16.np Calc=MJ8 Fror3Doorfaces: E Entire House 1804 25043 29181 0 1090 Other equip loads 0 0 Equip. @ 0.95 RSM 27838 Latent cooling 6866 TP1TAl Q IOnA 7GnA4 4A7nA A 4nnn VVT LJVTJ J VT V I VZJV Boldldalic values have been manually overridden Calculations approved byACCAto meet all requirements of Manual J 8th Ed wrightsoft- 2021-May-2614:3321 Z&^� AIII* 1O11111*mm•w•r� l Right-Sute®Uriversal202121.0.05RSU29964 Paget ...ersWryUserlDoasnerts%W6ghtsoftWACWIW-16.np Calc=MJ8 FrordDoorfaces: E - +- wrightsoft, Project Summary Entire House For: MW-16 3605 GROVE CT, FORT PIERCE, FL 34951 Notes: Weather: St Lucie Co Infl, FL, US Winter Design Conditions Outside db 41 OF Inside db 70 OF Design TD 29 OF Heating Summary Structure 23363 Btuh Ducts 1681 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipmentload 25043 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatingg Cooling Area (ft2) 1804 1804 Volume (fta) 17825 17825 Airchanges/hour 0.38 0.20 Equiv AVF (cfm) 113 59 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 7.3 kW 24817 Btuh 0 0 cfin 0 cfmBtuh 0.50 in H2O Job: Date: May26, 2021 By. Summer Design Conditions Outside db 90 OF Inside db 72 OF Design TD 18 OF Daily range L Relative humidity 52 % Moisture difference 61 grAb Sensible Cooling Equipment Load Sizing Structure 25990 Btuh Ducts 3190 Btuh Central vent (0 cim) 0 Btuh (none) Blower 0 Btuh Use manufacturers data n Rate/swingg multipplier 0.95 Equipmentsensible load 27838 Btuh Latent Cooling Equipment Load Sizing Structure 5459 Btuh Ducts 1407 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 6866 Btuh Equipment Total Load (Sen+Lat) 34704 Btuh Req. total capacity at 0.70 SHR 3.3 ton Cooling Equipment Summary Make Lennox Trade LENNOX Cond ML14XC1-041-230A** Coil CBA27UHE-048-230*++TDR AHRI ref 10259425 Efficiency 13.0 EER,16 SEER Sensible cooling 26950 Btuh Latentcooling 11550 Btuh Total cooling 38500 Btuh Actual airflow 1090 cfi71 Air flow factor 0.037 cfmBtuh Static pressure 0.50 in H2O Load sensible heat ratio 0.81 Bo/drdalic values have been manually overridden Calculations approved byACCAto meet all requirements of Manual J 8th Ed. t - =!Rntsoft- 2021-May-2614:33.22 ^��•• •^ • ea �• • =•ma Right-Sute®Uriversal2021 21.0.05 RSU29964 Page 1 ersWriyUserlDownentslWdghtsoftHVACWIW-16.rup Calc=MJ8 FrortDooriaces: E W LO U 7— LLI W >� O C) W_ ULo OOf O � LL-