Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Site Plan
RECEIVED R APR 2 9 2021 ST. Lucie County, Permitting I 4 1300 CONCORD TERRACE, SUITE 200 SUNRISE FL, 3332.3 . REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY A2PO105A-PJD/FOX SITE (BU: 5800245) 5041 ST LUCIE BOULEVARD FORT PIERCE, FL 34946 LATITUDE--27`2-8'54:2-1".N, L.ONGITUDE80°22'32._71"W ER L7 S[ E VICINITY MAP FROM T-MOBILE OFFICE PROCEED NORTHWEST ON CONCORD TERRACE TOWARD SAWGRASS CORPORATE PKWY, TURN LEFT ONTO SAWGRASS CORPORATE PKWY, USE THE 2ND FROM THE RIGHT LANE TO TURN LEFT ONTO W SUNRISE BLVD. USE THE RIGHT 2 LANES,TO MERGE ONTO FL-869 N VIA THE RAMP TO W PALM BEACH, MERGE ONTO FL-869 N, USE THE RIGHT 2 LANES TO TAKE EXIT 21A-B FOR FLORIDA'S TURNPIKE N, MERGE ONTO FLORIDA'S TURNPIKE, TAKE EXIT 152 FOR FL-70 TOWARD FORT PIERCE/OKEECHOBEE,-CONTINUE STRAIGHT ONTO FL-713 N (SIGNS FOR FL-70 W/OKEECHOBEE/VERO BEACH) TURN RIGHT ONTO COUNTY RD 608 (EAST)/ST LUCIE BLVD. TURN RIGHT ONTO CENTER RD, THE SITE WILL BE ON THE LEFT. DRIVING DIRECTIONS THIS IS AN APPLICATION FOR A: MODIFICATION OF AN EXISTING UNMANNED WIRELESS TELECOMMUNICATION SITE. PROJECT DESCRIPTION APPLICANT&ESSEE MDCMC NAME: T-MOBILE PROJECT MANAGER: JOSE DELGADO PHONE (954) 696-1573 PROPERTY INFORMATION OWNER: CROWN CASTLE INTERNATIONAL 6420 CONGRESS AVE. SUITE 2000 BOCA RATON, FL 33487 CONTACT: SUSAN PALM (205) 587-1867 HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS NOT REQUIRED. PROJECT INFORMATION EQUIPMENT LOCATION: ® OUTDOOR ❑ INDOOR ANTENNA LOCATION: ❑ WATER TOWER ❑ SELF SUPPORT TOWER ® MONOPOLE ❑ ROOF TOP ❑ NEW TOWER ❑ OTHER PROJECT SUMMARY ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING .IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1. 7TH EDITION (2020) FLORIDA BUILDING CODE 5. AMERICAN INSTITUTE OF STEEL 2 2017 NATIONAL ELECTRIC CODE (NEC) PATH CONSTRUCTION SPEQFICATICNS (AISC) LOCAL AMENDMENTS 7. UNDERWRITERS LABORATORIES (U.L) 3. AN9/TIA/E1A APPLICABLE STANDARDS APPROVED ELECTRICAL PRODUCTS 4. LIFE SAFETY CODE NFPA-101-2018 8. LOCAL BUILDING CODE 5 71H EDITION (2020) FLORIDA FIRE PREVENTION CODE 8. aTY/COUNTY ORDINANCES 10. NFPA 55 (2016) CODE COMPLIANCE CIVIL ENGINEER: KIMLEY-HORN AND ASSOCIATES, INC. 1920 WEKIVA WAY, SUITE 200 WEST PALM BEACH, FL 33407 (561) 845-0665 STRUCTURAL ENGINEER: N/A ELECTRICAL ENGINEER: KIMLEY-HORN AND ASSOCIATES, INC. 1920 WEKIVA WAY, SUITE 200 WEST PALM BEACH,. FL 33407 (561) 845-0665 SURVEYOR: N/A TOWER ENGINEER: N/A I PROJECT TEAM I FILE COPY SHEET DESCRIPTION REV. T-,1 COVER SHEET 0 G-1 I GENERAL NOTES 0 C- .1 1 SITE PLAN & EQUIPMENT LAYOUT PLANS 0 C-2 TOWER ELEVATION AND ANTENNA LAYOUT 0 C-3 EQUIPMENT MOUNTING DETAILS 0 E-1 ELECTRICAL SITE PLAN & NOTES 0 E-2 EQUIPMENT GROUNDING DETAILS 0 SHEET INDEX ISSUED FOR: EXCALIBUR DATE: APRIL 2021 DESIGN: 7TH EDITION (2020) FLORIDA BUILDING CODE WIND LOADS (ASCE 7-16) ULTIMATE WIND SPEED = 160 MPH NOMINAL WIND SPEED = 124 MPH RISK CATEGORY II WIND EXPOSURE = C T • Mobile .- 1300 CONCORD TERRACE, SUITE 200 SUNRISE FL, 33323 PJD/FOX SITE A2P0105A 5041 ST LUCIE BOULEVARD FORT PIERCE, FL 34946 ST. LUCIE COUNTY :CURRENT ISSUE DATE: APRIL 2021 EXCALIBUR Kimley*Horn © 2021 KIMLEY—HORN AND ASSOCIATES, INC. 1920 WEKIVA WAY, SUITE 200 WEST PALM BEACH, FLORIDA 33411 (561) 845-0665 FBPE REGISTRY NO. 696 BRAWN BY:=CHK.: APV.: GD I LF I CMM KEVIN K. MARAJH PE 71455 MARIA VICTORIA MARTIN PE 72397 . CHELSEA M. MARAJH PE 84300. COVER SHEET m This doavnml,'t.aeNm .IM Ue cmc'�le and dalan. prt.mted herein. as m in.4umml of evNc., Iv intended and far tie. epedfic p Tr and dI.1 for .INwlt.ritlmtry�,atian and addrtvaHv-i py gMvy-Hmnwd �atq ma. enm e. .:uwt nwenr eo wau.r-xam ma KHA Job 0442905W STANDARD PROVISIONS INTENT A. THESE SPECIFICATIONS AND CONSTRUCTION DRAWINGS ACCOMPANYING THEM DESCRIBE THE WORK TO BE PERFORMED AND TEMPORARY FACILITIES: A WATER: COMPLIANCE A. ALL MATERIALS, DESIGN, AND WORKMANSHIP SHALL BE IN I. INSPECTIONS THE CONTRACTOR SHALL NOTIFY THE CPM AT LEAST 24 HOURS THE MATERIALS TO BE FURNISHED FOR THE CONSTRUCTION OF WATER IS NOT AVAILABLE TO THE CONTRACTORS ON SITE. ACCORDANCE WITH ALL APPLICABLE CODES (SOME OF WHICH ARE IN ADVANCE OF REQUIRED INSPECTIONS. INSPECTIONS THAT THE T-MOBILE SITE. LISTED BELOW), ORDINANCES, AND AUTHORITIES HAVING WILL BE REQUIRED BY THE CPM OR OTHER DESIGNATED B. LIGHT AND POWER: JURISDICTION OVER THE WORK. UPON THE COMPLETION OF THE T-MOBILE REPRESENTATIVE ARE: B. THE DRAWINGSWORK, AND SPECIFICATIONS ARE INTENDED TO BE LIGHT AND POWER ARE AVAILABLE ON SITE. THE CONTRACTOR SHALL PROVIDE T-MOBILE WITH A CERTIFICATE OF OCCUPANCY (IF REQUIRED) AND OTHER LEGAL 1• INSPECTION OF GROUNDING SYSTEM FULLY EXPLANATORY AND COMPLEMENTARY. HOWEVER, SHOULD C. TELEPHONE: DOCUMENTS TO VERIFY SUCH COMPLIANCE. WHERE NO CODES 2. PRACTICAL COMPLETION ANYTHING BE SHOWN, INDICATED OR SPECIFIED ON ONE AND EXIST, THE WORK SHALL CONFORM WITH THE 7TH EDITION (2020) NOT THE OTHER, IT SHALL BE THE SAME AS IF SHOWN, EACH CONTRACTOR TO PROVIDE HIS OWN TELEPHONE FLORIDA BUILDING CODE, AND/OR THE SPECIFICATIONS HEREIN, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ENSURING INDICATED OR SPECIFIED ON BOTH. ACCESS IF REQUIRED. WHICHEVER IS MORE STRINGENT, AND A DOCUMENT STATEMENT SHALL BE THAT ALL RELEVANT AUTHORITY INSPECTIONS ARE CARRIED OUT FURNISHED TO THIS EFFECT. IN A TIMELY MANNER. THE CONTRACTOR SHALL PROVIDE C. THE INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR LE D. IF PERMANENT POWER IS COMPLETED, ALL CONTRACTORS MAY DOCUMENTATION OF ALL INSPECTIONS. AND MATERIALS REASONABLY NECESSARY FOR THE PROPER „cr n,r cro.,,rr ,.,,.N,r..�,.,., r.,e .,�..,,,,..�...., ..,.,r,..,.,,.. n.1c enuTnerrno is occonucioir rno ,—„ T • •Mobile e 1300 CONCORD TERRACE, SUITE 200 SUNRISE FL, 33323 PROJECT INFORMATION: PJD/FOX SITE A2P0105A 5041 ST LUCIE BOULEVARD FORT PIERCE, FL 34946 ST. LUCIE COUNTY URRENT ISSUE DATE: APRIL 2021 SSUED FOR- F- EXCALIBUR EV.:=DATE:====IDESCRI PTION: \` t., SEAL•.,- � •� �'Y�V � i yM r ,3..0 _ r s .;fir l�j '� a$e � •y� i ( LANS P,.,.-.�".... Kim a Worn © 2021 KIMLEY-HORN AND ASSOCIATES. INC. 1920 WEKIVA WAY, SUITE 200 WEST PALM BEACH, FLORIDA 33411 (561) B45-0665 F13PE REGISTRY NO. 696 ROVIDER: RAWN BY:=CHK.: APV.: GO LF :mm CENSURE: KEVIN K. MARAJH PE 71455 MARIA VICTORIA MARTIN PE 72397 CHELSEA M. MARAJH PE 84300 HEET TITLE GENERAL NOTES HEET NUMBER.' —OE\ASION Gml KHA Job #: 044290553 EXISTING T—MOBILE WAVEGUIDE BRIDGE EXISTING T—MOBILE UTILITY (TYP.) H—FRAME X X X X X X X X - X X X X X X X X X X X X X \ EXISTING T—MOBILE 15KW DIESEL X ` GENERATOR ID EXISTING AT&T J WAVEGUIDE BRIDGE )(� (TYP•) EXISTING T—MOBILE EQUIPMENT ON CONCRETE / - PAD EXISTING 135't / MONOPOLE ` EXISTING 13'-6" DOUBLE --- SWING ACCESS GATE EXISTING AT&T EQUIPMENT ON CONCRETE PAD � GRAVEL AREA � X Ll EXISTING MULTI TENANT X UTILITY H—FRAME EXISTING FIBER PEDESTAL EXISTING AT&T UTILITY PILE C ®PY H—FRAME EXISTING 8' HIGH CHAIN —LINK FENCE EXISTING HANDHOLE W/ PRIVACY SLATS & 3 STRAND BARBED WIRE X EXISTING AT&T EMPTY - EXISTING IRRIGATION PUMP EQUIPMENT CONCRETE PAD L X X X X X X X- X X X xi X. X X X X X X X X X SITE PLAN SCALE FEET NORTH REVIEWED �.t ``�I EXISTING GENERATOR ATS EXISTING PPC CABINET EXISTING FIBER CABINET //�� EXISTING TELCO lot CABINET OIC[01 � r�I1uw�1C.�.�i� h a wt d aeo�een1.. Pima °a = . p.N 'via«tea mmt i �..t nrum wen aM.lV.l a W pt. a �itimm m N�- a ie.ada.s me aim a vthwt nmmtr to w"u.r-n�. -a A..a m - .- nn:nnia lll.•.III I ninannaGENERATORnnrnngi ni uw,i EXISTING EQUIPMENT LAYOUT PLAN LEGEND (D EXISTING T—MOBILE HPL3 SODA SSC TO BE REMOVED O E)OSTING T—MOBILE COUP TO BE REMOVED OC EDOSTING T—MOBILE FCOA CABINET TO BE REMOVED DO ETOSDNG T—MOBILE RBA 72 CABINET TO BE REMOVED OEXISTING T—MOBILE S133 (BBU) CABINET TO BE REMOVED OF EXISTING T—MOBILE FXFC RRU9 TO BE REMOVED OEXISTING T—MOBILE (3) COMMSCOPE (CBC1923T—DS-43) DIPLEXERS TO BE REMOVED OH EXISTING T—MOBILE AIRSCALE AMOB TO BE REMOVED I� PROPOSED T—MOBILE 6160 CABINET OJ PROPOSED T—MOBILE B16O CABINET NORTH 0 4' 8' SCALE FEET CODE COMPLIANCE S ■ o LUCIE COUNTY BOCC EXISTING GENERATOR ATS EXISTING PPC CABINET PROPOSED T—MOBILE RIPS HCS EXISTING FIBER TRUNK CABLE ENTERING THE BACK CABINET OF PROPOSED 6160 CABINET EXISTING TELCO CABINET -X X X X X X X X 0 EXISTING T—MOBILE WAVEGUIDE BRIDGE (TYP.) _ PROPOSED LUMENGEN LED LIGHT (10' MINIMUM ABOVE GRADE)2CONNEC ED TO POLE MROTARY TOUNTED IMER WITH 60 MINUTF3, MOUNTED PER MANUFACTURER'S SPECIFICATIONS. (OR APPROVED EQUAL). PROPOSED EQUIPMENT LAYOUT PLAN T • •Mobile •° 1300 CONCORD TERRACE, SURE 200 SUNRISE FL, 33323 PJD/FOX SITE A2P0105A 5041 ST LUCIE BOULEVARD FORT PIERCE, FL 34946 ST. LUCIE COUNTY CURRENT ISSUE DATE: APRIL 2021 EXCALIBUR © 2021 KIMLEY--HORN AND ASSOCIATES, INC. 1920 WEKIVA WAY, SUIlE.200 WEST PALM BEACH, FLORIDA 33411 (561) 845-0665 FBPE REGISTRY N0. 696- GD LF CMM KEVIN K. MARA.W PE 71455 MARIA VICTORIA MARTIN PE 72397 CHELSEA N. MARAJH PE 84300 SITE PLAN & T-MOBILE EQUIPMENT LAYOUT cmi =KHA Job #: 044290553 4 TOP OFF IOWER ,�. EL 135_ 4 EXISTING ANTENNAS EL. 133 f RAD CENTER OF EXISTING AND PROPOSED T-MOBILE ANTENNAS EL 122't (6) EXISTING ANTENNAS TO BE REMOVED AND REPLACED WITH (6) PROPOSED ANTENNAS. EXISTING MOUNT TO REMAIN. ANTENNA SECTOR SECTOR A EXISTING COAX LENGEJI SIZE I QTY. I USED I SPARE 175'f 11 5/8" 1 4 1 2 1 2 SECTOR B 175't 1 5/8" 4 2 2 SECTOR C 175't 1 5/8'1 4 2 2 EXISTING HYBRID ILENGTHI SIZE I QTY. 175't 1'1.24" 1 1 EISTING T—MOBILE FRIG RRU TO BE REMOVED s 92 z EXISTING T—MOBILE L2100 QUAD 30p ANTENNA TO BE REMOVED EXISTING T—MOBILE L700/L60O/N600 & — G1900/U2100 OCTA ANTENNA TO BE REMOVED q2S oToR EXISTING T—MOBILE THAN STYLE 3C TMA TO BE REMOVED EXISTING T—MOBILE AHLOA RRU TO BE REMOVED EXISTING T—MOBILE FRIG RRU TO BE REMOVED a m N m EXISTING T—MOBILE L2100 QUAD II a ANTENNA TO BE REMOVED A m om EXISTING T—MOBILE COUP TO BE REMOVED NOTES: 1. SAFETY CLIMB AND CLIMBING PATH MAY NOT BE OBSTRUCTED IN ANY WAY. DO NOT TRAP THE SAFETY CLIMB. EXISTING MONOPOLE EXISTING ANTENNA MOUNT N.T.S. EXISTING T—MOBILE TWIN STYLE 3C TMA TO BE REMOVED EXISTING T—MOBILE L700/L600/14600 & G1900/U2100 OCTA ANTENNA TO BE REMOVED EXISTING T—MOBILE AHLOA RRU TO BE REMOVED P �02- p0 EXISTING T—MOBILE L2100 QUAD ANTENNA TO BE REMOVED EXISTING T—MOBILE FRIG RRU TO BE REMOVED _ EXISTING T—MOBILE AHLOA RRU TO BE REMOVED EXISTING T—MOBILE TWIN STYLE 30 TMA TO BE REMOVED EXISTING T—MOBILE L700/L600/N600 & G1900/U2100 OCTA ANTENNA TO BE REMOVED PiEVIEWE® FOR O DE COMPLIANCE C)CC COPIaBr PROPOSED TRUNK P EXISTING 135't ILENGTHI SIZE I QTY. MONOPOLE TOWER 1 175±1 1.99" 1 2 qZ �to� `'° 5``Pb" PROPOSED T—MOBILE FFHH-65C—R3 PROPOSED T—MOBILE AIR6449 ANTENNA 300 ANTENNA MOUNTED TO EXISTING MOUNT MOUNTED TO EXISTING MOUNT PER PER MANUFACTURER SPECIFICATIONS M' v a _=._ s ;. MANUFACTURER SPECIFICATIONS PROPOSED T—MOBILE 4480 RRU PROPOSED T-MOBILE 4460 RRU MOUNTED TO EXISTING MOUNT PER ANTENNA MOUNTED TO EXISTING MOUNT MANUFACTURER SPECIFICATIONS PER MANUFACTURER SPECIFICATIONS NOTE: sF° THIS DRAWING IS INTENDED TO DEPICT THE GENERAL q2 PROPOSED T—MOBILE AIR6449 ANTENNA LOCATION AND HEIGHT OF THE PROPOSED 300 nc�= __.: .'., �Pti MOUNTED TO EXISTING MOUNT PER ANTENNAS ON THE EXISTING TOWER. CONSTRUCTION PROPOSED T—MOBILE FFHH-65C—R3 ,<. ate° SHALL NOT PROCEED UNTIL A STRUCTURAL ANTENNA MOUNTED TO EXISTING MOUNT �� �, � �g� MANUFACTURER SPECIFICATIONS ANALYSIS REPORT HAS BEEN COMPLETED BY A PER MANUFACTURER SPECIFICATIONS PROFESSIONAL ENGINEER REGISTERED IN THIS STATE, _ _ CONCLUDING THAT THE EXISTING TOWER IS PROPOSED T—MOBILE 4480 RRU y ANT6NNAPROPOS�MOUNTED TOEXISTING MOUNT STRUCTURALLY ADEQUATE TO RESIST THE EXISTING MOUNTED TO EXISTING MOUNT PER AND PROPOSED LOADS. MANUFACTURER SPECIFICATIONS PER MANUFACTURER SPECIFICATIONS PROPOSED T—MOBILE 4460 RRU ANTENNA MOUNTED TO EXISTING MOUNT PER MANUFACTURER SPECIFICATIONS PROPOSED T—MOBILE AIR6449 ANTENNA MOUNTED TO EXISTING MOUNT PER MANUFACTURER SPECIFICATIONS �-- PROPOSED T—MOBILE 4480 RRU m MOUNTED TO EXISTING MOUNT PER N m MANUFACTURER SPECIFICATIONS mA II A PROPOSED T—MOBILE FFHH-65C—R3 m g m ANTENNA MOUNTED TO EXISTING MOUNT PER MANUFACTURER SPECIFICATIONS TOWER ELEVATION 2 ALL TOWER MOUNTED EQUIPMENT (TINE DIPLEXER, N.T.S. 7MA'S, RRU) MUST BE INSTALLED BEHIND THE ihb dowmmp togeNc SIN the cmeepte and dedane prtemted hertln. » m ANTENNAS IF THE CANNOT BE MOUNTED BEHIND THE PROPOSED ANTENNA LAYOUT :nay, Ii n.lprq"mea.'pamo°r°�d i'ee .°De�ce w; aoommit t' � ANTENNA THEN PLEASE CONTACT THE CROWN m""� �m e: a� i olir to iauap> ex"� °�a"A: dd m� "°°°""t°° CASTLE PM IMMEDIATELY FOR FURTHER DIRECTION. N.T.S. T • •Mobile W 1300 CONCORD TERRACE, SUITE 200 SUNRISE FL, 33323 ROJECT INFORMATION: PJD/FOX SITE A2P0105A 5041 ST LUCIE BOULEVARD FORT PIERCE, FL 34946 ST. LUCIE COUNTY F—CURRENT ISSUE DATE: APRIL 2021 SSUED FOR: F_ EXCALIBUR EV.:=DATE:—DESCRIPTION: llll�il// M»..W SEAL• Rla 84300 .� .� i OF APR��� LAWS PREPARE Kimley»)Horn © 2021 KIMLEY-HORN AND ASSOCIATES INC. 1920 WEKIVA WAY, SUITE 200 WEST PALM BEACH, FLORIDA 33411 (561) 645-0665 FBPE REGISTRY NO. 696 ROVIDER: RAVIN BY�=CHK.: APV.: GD I LF CMM CENSURE: KEVIN K. MARAJH PE 71455 MARIA VICTORIA MARTIN PE 72397 CHRSEA M. MARAJH PE 84300 HEEf TITLE TOWER ELAVATION AND ANTENNA DETAILS HEEf NUMBER•REVISION C=2 KHA Job. #: 044290553 WPROPOSED ANTENNA FFHH-65C-R3 WIDTH: 25.2" HEIGHT: 95.9" DEPTH: 9.3" PROPOSED ANTENNA ANTENNA+RADIO AIR 6449 WIDTH: 20.5" HEIGHT. 33.11" DEPTH: 8.5" xTM.w°mml mL. a1.. a d a .11W% u a�� .�t.ae mmi 1811,11 vnd xnpcpe rtllmiu an W. Eom.ml mNoul .ritlm valborlxWan and adaplallm by KZ1'1 .'Z and Maaalva � .nal b. "iibwt fiab�Ity l" 10nley-Nam an! A.eWatva Nc INSTALLER NOTES: 1. COMPLY WITH MANUFACTURERS INSTRUCTIONS TO ENSURE THAT ALL RRHs RECEIVE ELECTRICAL POWER WITHIN 24 HOURS OF BEING REMOVED FROM THE MANUFACTURER'S PACKAGING. 2. DO NOT OPEN RRH PACKAGES IN THE RAIN. 3. ALL PIPES, BRACKETS, AND MISCELLANEOUS HARDWARE TO BE GALVANIZED UNLESS NOTED OTHERWISE. NEW RRH ANT MOUNTING BRACKET W/ NNA BRACKET / W/ r,1ANTENNA WITH RRH MOUNTING DETAIL SCALE: NOT TO SCALE RRH 1NTING PLATE r_vIEWE® FOR "..CoDE COMPLIANCE ST. LUCIE C®I NTY I3oCC MOUNT PIP UNISTRUT P100 (TYP.) --/ SS HARDWARE AS REQUIRED CTJ BOX T . •Mobile •Q 1300 CONCORD TERRACE, SUITE 200 SUNRISE FL, 33323 ROJECT INFORMATION: PJD/FOX SITE A2P0105A 5041 ST LUCIE BOULEVARD FORT PIERCE, FL 34946 ST. LUCIE COUNTY URRENT ISSUE DATE: APRIL 2021 FOR: EXCALIBUR 1EV.:--DATE-.===DESCRIPTION- ..4SUED KA SEAL: No,a, TATE OF LAMS PRE G . Kimley>Mo-Irn © 2021 KIMLEY-HORN AND ASSOCIATES, INC. 1920 WEKIVA WAY, SUITE 200 WEST PALM BEACH, FLORIDA 33411 (561) 845-0665 FBPE REGISTRY NO. 695 . ROVIDER: RAWN BY:=CHK.: APV.. GD r( LF CMM CENSURE: KEVIN K. MARAJH PE 71455 . MARIA VICTORIA MARTIN PE 72397 CHELSFA M. MARAJH PE 84300 HEET TITLE EQUIPMENT MOUNTING DETAILS HEET NUMBER• =REVISION -3 KHA Job #: 044290553 i r GENERAL NOTES: CONDUIT INSTALLATION NOTES: ALL CONDUIT RUNS AND EQUIPMENT LOCATIONS ARE SHOWN DIAGRAMMATICALLY CONTRACTOR TO FIELD COORDINATE WITH WIRELESS CARRIER BEFORE INSTALLATION. CONTRACTOR SHALL PROVIDE TRAFFIC RATED, QUAZITE UL LISTED, PULL BOXES WHERE REQUIRED. WHERE U.G. CONDUIT ROUTE IS UNDER EXIST SLAB CUT AND PATCH ASPHALT/CONCRETE AS REQUIRED, MATCH EXIST. CONTRACTOR SHALL COORDINATE ALL GROUNDING WITH T-MOBILE CPM BEFORE INSTALLATION. ALL EXPOSED GROUNDING CONDUITS SHALL BE IN A 1/2' PVC SCHEDULE 80 CONDUIT. A-9. 11 -1 _3 & 15 (1) 2' ELECTRICAL CONDUITS FROM EXISTING PPC TO PROPOSE 6160 CABINET EXISTING FIBER CABINET PROPOSED T-MOBILE RFS HCS EXISTING TELCO TRUNK CABLE ENTERING THE CABINET BACK OF 6160 CABINET XVX X X X X X— n n EXISTING T—MOBILE WAVEGUIDE BRIDGE (TYP.) APPROXIMATE LOCATION OF EXISTING 5/8'X10' GROUND ROD WITH INSPECTION SLEEVE NI I NOTES: 1) ALL GROUND WIRES ARE TO BE 02 TINNED SCUD COPPER WIRES ,f ELECTRICAL SITE PLAN FIBER CABINET 2-2" CONDUIT T01 WITH PULLSTRING T02 TO TELCO CO. POINT OF DEMARCATION. GI2ADE TO FIBER DEMARC (1) 2" CONDUIT, EXTEND TO 6160 CABINET, WIRE FIBER CIRCUITS AS DIRECTED BY WIRELESS CARRIERS CPM. FIBER RISER DIAGRAM A-14 (1) 1/2' ELECTRICAL CONDUITS FROM EXISTING PPC TO PROPOSE LE LIGHT T ` PROPOSE T-MOBILE LED LIGHT EXISTING T-MOBILE — — — 15KW DIESEL GENERATOR - APPROXIMATE LOCATION OF EXISTING #2 EQUIPMENT GROUND RING 1. GENERAL A THE CONTRACTOR SHALL PROVIDE ALL MATERIAL AND LABOR FOR A COMPLETE ELECTRICAL SYSTEM AS INDICATE ON.THE DRAWINGS. ITEMS NOT SHOWN BUT OBVIOUSLY NECESSARY FOR A COMPLETE SYSTEM SHALL BE INCLUDE. B. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS, INSPECTIONS AND APPROVALS. C. ALL WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE AND THE LOCAL BUILDING CODES. ALL COMPONENTS SHALL BE U.L APPROVE. D. THE CONTRACTOR SHALL" BEFORE SUBMITTING HIS BID, VISR THE SITE OF THE PROJECT AND BECOME FAMILIAR WITH THE CONDITIONS. NO ALLOWANCE WILL BE MADE FOR EXISTING CONDITIONS OR FAILURE OF THE CONTRACTOR TO OBSERVE THEM. E. EXACT LOCATION OF ALL EQUIPMENT SHALL BE COORDINATE WITH WIRELESS CARRIER, THE BUILDING OWNER AND OTHER TRADES. F. WHERE EQUIPMENT IS SPECIFIED BY MANUFACTURER AND TYPE, SUBSTITUTION SHALT. ONLY BE MADE WITH THE APPROVAL OF THE ENGINEER. THE CONTRACTOR SHALL SUBMIT DETAILS OF PROPOSE MATERIALS, REASON FOR CHANGE AND CHANGE IN CONTRACT AMOUNT. 2. SCOPE OF WORK A THE CONTRACTOR SHALL PROVIDE ALL ELECTRICAL WIRING AND EQUIPMENT UNLESS OTHERWISE INDICATE. MAIN COMPONENTS ARE AS FOLLOWS: 1. PROVIDE ELECTRICAL RACEWAYS & WIRING AS INDICATE ON THE DRAWINGS. 2. PROVIDE ELECTRICAL EQUIPMENT MOUNTED AS DIRECTED BY CARRIER AND AS INDICATE ON THE DRAWINGS. EXISTING PPC CABINET EXISTING GENERATOR ATS 3. PROVIDE TELEPHONE CONDUIT WITH PULL WIRE AND CABLE AS INDICATE ON DRAWINGS. 4. INSTALL WIRE AND CONDUIT AS INDICATE. PROVIDE CABLE SUPPORTS AS INDICATE. 5. REPLACE EXISTING WIRELESS CABINET WITH NEW OWNER FURNISHED WIRELESS CABINETS AS INDICATED ON DRAWINGS. 6. REUSE EXISTING GROUND JUMPERS WHEN POSSIBLE FROM FORMER WIRELESS CABINETS; PROVIDE NEW GROUND JUMPERS TO NEW CABINETS AS REQUIRE. 7. PROVIDE GROUNDING PROTECTION SYSTEM AS INDICATE. 8. RESTORE ALL AREAS TO ORIGINAL CONDITION AFTER INSTALLATION OF CONDUIT. 9. CONTRACTOR SHALL CLEARLY LABEL DISCONNECTS AND OTHER RELATE GEAR. 10. AT TIME OF PLAN PERMITTING, CONTRACTOR SHALL APPLY FOR A THIRTY (30) DAY TEMPORARY POWER PERMIT FOR TESTING PURPOSES. 3. CONDUIT A CONDUIT SIZES AS SHOWN ON THE DRAWINGS ARE A MINIMUM. THE CONTRACTOR MAY INCREASE AS REQUIRE FOR EASE OF PULLING. B. CONDUIT TYPES SHALL BE AS FOLLOWS UNLESS OTHERWISE INDICATE: 1. ALL ABOVE GRADE CONDUIT SHALL BE RIGID GALVANIZE STEEL 2. ALL CONDUIT BELOW GRADE SHALL BE SCHEDULE 40 PVC. 3. CONCEALED CONDUIT IN WALLS OR ABOVE CELING SHALL BE EMT. C. ALL EXPOSE CONDUIT SHALL BE NEATLY INSTALLED AND RUN PARALLEL OR PERPENDICULAR TO STRUCTURAL ELEMENTS. SUPPORTS AND MOUNTING HARDWARE T BACK TO EXMIJ2.BOND. - PFIELD VERIFY C01 WID AMPACITY EXISTING METER CAN & METER BOND 12 M O TO EXISTINGG W2 PROPOSE I6160 EXISTINGCABINET2P-200/20OA CLF DISC, SE RATED, 100 KAIC,NEMA 3R IJ2,BOND, 5/8-X10' WEATHERPROOF EMERGENCY COPPER CLAD, TYR. STANDBY GENERATOR CO3 3-3/0.1J6,2'C C04 3-3/0,1/6,2'C ^ r , 15 2P-60 KW LOAD CALC A LOAD AMPS PROPOSED 6160 GABI&F 130 PROPOSED LID LIGHT 1 BLOCK HEATER 1 BATTERY CHARGER 1 GFI 1 TOTAL 134 EXIST VOLTAGE PROVIDE: 24UV, 1 PHASE, 3W EXIST SERVICE PROVIDED: 1C fl 3 OCU. 2DOA LOAD UNDER GENERATOR: WIRELESS CABINET" OUTPUT (LOAD) IS CONTROLLED BY MONITORING SOFTWARE. SOFTWARE HAS LOAD SHEDDING CAPABILITIES AND IS AWARE WHEN CABINETS. ARE ON EMERGENCY POWER AT WHICH TIME ALL WIRELESS CABINETS ® 60% OF MAX LOAD (134 AMPS x 60% LOAD = 80 AMPS) BOND PE GNOj I �EXISTINGATS JUMPER TO SWITCH EXISTING 0— GROUND RING 2P-200A WS 5�1 NEMA 3R V 6'-0 Y MIN. BATT JKr 0 CONTROL PANEL 3-3/0,1;4,2-C 2 f 2P-200 I EXISTING 200A, 3W, I C MI —c 2P-200 I APPLETON GENERATOR RECEPTACLE, ADR20043RS STYLE 2 L — — — I 5#14.7/4'G 3-3/0,1j4,2'C O GFCI F24 POSITION \ �� A — 1 & 5 PUSH BUTTON PNLEID \ A_2 KILL STATION I SEE I. I �SURC� FOR GENERATOR SCHEDULE PS'R L J �REUiO _ T_ A-1. 3 JUMPER / TONEXISTINGNGROUND RING 2-3/0,2#6,2'C - RE —USE EXISTING 4P-200 BRANCH BREAKER TO PROPOSED 6160 CABINET SEE PNLBD SCHEDULE N.T.S 1 1 1 ONELINE DIAGRAM SHALL BE HOT DIPPED GALVANIZE STEEL NYLON INSULATE BUSHINGS SHALL BE USE ON ALL CONDUIT TERMINATIONS. D. FLEX CONDUIT SHALL BE LIQUID TIGHT FLEXIBLE METALLIC CONDUIT. E. NO CONDUIT SHALL BE INSTALLED IN LIFE SAFETY AREAS SUCH AS STAIRWAYS. F. CONDUIT ROUTES ARE SCHEMATIC. FIELD VERIFY ROUTE BEFORE BID. COORDINATE ROUTE WITH WIRELESS CARRIER AND BUILDING OWNER. G. WEATHERPROOF HUBS SHALL BE USED FOR ALL TOP AND SIDE PENETRATIONS TO ENCLOSURE LOCATED OUTDOORS. 4. CONDUCTORS A CONDUCTORSSHALL' BE ST INDE COPPER TYPE THWN WITH 75 DEGREE C RISE INSULATION. 5. PULL BOXES AND JUNCTION BOXES A. INTERIOR ENCL SHALL BE NEMA 1. EXTERIOR ENCL SHALL BE NEMA 3R. 6. GROUNDING A PROVIDE GROUND SYSTEM AS INDICATE ON THE DRAWINGS AND AS REQUIRE BY THE NATIONAL ELECTRIC CODE AND RADIO EQUIPMENT MANUFACTURER. B. ALL RACEWAYS REQUIRE GROUNDING CONDUCTORS. BONDING CONDUCTORS THROUGH THE RACEWAY SYSTEM SHALL BE CONTINUOUS FROM MAIN SWITCH GROUND BUSES TO PANEL GROUND BARS, AND FROM PANEL GROUNDING BARS TO BRANCH CIRCUIT OUTLETS, MOTORS, LIGHTS, ETC. THESE GROUND CONDUCTORS ARE REQUIRE THROUGHOUT THE PROJECT REGARDLESS OF WHETHER CONDUIT RUNS SHOW GROUND CONDUCTORS ON THE DRAWINGS. C. COORDINATE WITH ENCLOSURE SUPPUER TO INSTALL TELCO GROUND BARS BELOW THE TELCO BOARD. CONNECT TO MAIN GROUNDING SYSTEM. ABBREVIATIONS E%�IEWED FOR 'dns' id✓ � COMPLIANC 'r-'� LUCIE COUNT` ®%C PROPOSE 6160 CABINET ILA, COPY ANT ANTENNA EMT ELECTRICAL METAWC TUBING AM AMERICAN WIRE GAUGE DWG DRAWING BOW BARE COPPER WIRE - LPS. LIGHTNING PROTECTION SYSTEM RWY RACEWAY- - S.S. STAINLESS STEEL TYP. TYPICAL PNL CLF. PANEL CURRENT UMITING FUSE RGS RIGID GALVANIZED STEEL CPM CONST. PROJ. MANAGER SYMBOLS v CADWELD TYPE CONNECTION ® 5/8' X10'—O' COPPERCLAD GRND. ROD W/INSP. SLEEVE 0 5/8' X10,-0' COPPERCLAD GRND. ROD 1 MECHANICAL TYPE CONNECTION — — — J2 TINNED SOLID BARE CU WIRE — — — UNDER GROUND TELCO CONDUIT — — — UNDER GROUND ELECTRIC CONDUIT C01 CONDUIT TAG 1; REFER TO RISER M-1,3 CONDUIT TAG 1; PANEL SCHEDULE ® GENERATOR RECEPTACLE M ELECTRICAL NOTES 14 JELECTRICAL SYMBOLS 5 I T • •Mobile •6 1300 CONCORD TERRACE, SUITE 200 SUNRISE FL 33323 PROJECT INFORMATION: PJD/FOX SITE A2PO105A 5041 ST LUCIE BOULEVARD FORT PIERCE, FL 34946 ST. LUCIE COUNTY URRENT ISSUE DATE: APRIL 2021 SSUED FOR: EXCALIBUR EV.:=DATE:—DESCRIPTION: SEAL. wwtE� A ow t e vA ..,aRP11)", LANS PR Kiml "V.* Hbrn ©'2021 MULEY--HORN AND ASSOCIATES INC. 1920 WEKIVA WAY, SUITE 200 WEST PALM BEACH, FLORIDA 33411 (561) 845-0665 FBPE REGISTRY NO. 696 ROVIDER: RAWN BY:=CHK.: APV.: GO LF CMM CENSURE: KEVIN K. MARAJH PE 71455 MARIA VICTORIA MARTIN PE 72397 CHELSEA M. MARAJH PE 84NO HEET TILE ELECTRICAL SITE PLAN AND NOTES HEET NUMBER•REVISION Eml KHA Job #: 044290553 r GROUNDING PROTECTION SYSTEM NOTES: 1. PROVIDE 'CABLE ENTRANCE GROUND BAR' (CEGB), 3*H X 61 X 1/4'D. MOUNT AT TELCO CABINET. COORD. INSTALLATION WITH CPM. 2. PROVIDE A GND RING BURIED A MINIMUM OF 18' BELOW GRADE THE GROUND RING SHALL BE INSTALLED A MINIMUM OF 2'-0' AWAY FROM THE FOUNDATION UNLESS SHOWN ON DRAWING. 3. BOND DISCONNECT SWITCH, METER, TELEPHONE CABINET AND SERVICE CONDUITS TO BURIED GND RING AS THEY CROSS. 4. EACH LEG OF THE WAVEGUIDE STRUCTURE SHALL BE INDIVIDUALLY BONDED TO THE BURIED GND RING. EXOTHERMICALLY WELD CONNECTIONS AT POST FOR WAVEGUIDE STRUCTURE AND BURIED GND RING. PLACE 5/8'X10' COPPERCLAD GND ROD AT 10' INTERVALS ALONG WAVEGUIDE PATH. 5. BOND REBAR IN CONCRETE FOR COMMUNICATION STRUCTURE AND. EQUIPMENT PAD TO BURIED GND RING. EXOTHERMICALLY WELD A #2 TINNED SOLID COPPER CONDUCTOR TO THE REBAR AND CONNECT TO THE BURIED GND RING. 6. PROVIDE INSPECTION SLEEVE AT MAIN SERVICE GROUNDS. EXOTHERMIC CONNECTIONS. 7. PROVIDE BONDING CONDUCTOR(S) FROM THE BURIED GND RING TO THE ANTENNA CABLE BUS BAR AT POINT JUST INSIDE OF THE COMMUNICATION STRUCTURE EXIT. VERIFY EXACT LOCATION OF COPPER BUS BAR FOR PROPER CONDUCTOR- LENGTH. FINAL EXOTHERMIC WELDS TO COPPER BUS BAR BY THE ANTENNA CABLE INSTALLER. 8. EXOTHERMICALLY WELD BONDING CONDUCTOR TO COMMUNICATION STRUCTURE LEG AT 1'-0' ABOVE PAD AND BOND TO BURIED GND RING. PROVIDE A 3/4'PVC SLEEVE WITH A GRADUAL BEND IN THE CONCRETE FOUNDATION. 9. 5/8'X10'-0' LONG COPPER CLAD GND ROD. 15' SPACING BETWEEN RODS (NON- LINEAR). TYPICAL FOR ALL GND RODS SHOWN. USE STAINLESS STEEL HARDWARE WHERE APPLICABLE. 10. ELECTRICAL CONTRACTOR SHALL TAKE MEGGER READINGS OF GND. THE RESULTS SHALL NOT BE GREATER THAN 5 OHMS. 11. ALL CONNECTIONS TO GND SYSTEM SHALL BE MADE IN LINE WITH BENDS NOMINAL 12' RADIUS IN THE DIRECTION OF CURRENT FLOW. T-CONNECTIONS WILL NOT BE ALLOWED. 12. ALL BENDS IN GND WIRES SHALL BE NOMINAL 12' RADIUS. 13. ANTENNA CABLES SHALL BE BONDED AT EACH END. RUNS GREATER THAN 150' SHALL BE BONDED TOWARDS MIDDLE OF LENGTH. COORDINATE LOCATION WITH WIRELESS CARRIER'S PROJECT MANAGER. 14.- WHEN APPLICABLE, CONTRACTOR SHALL BOND FRAMES TO EACH OTHER AND TO GND RING VIA TWO PATHS. COORDINATE WITH WIRELESS CARRIER PROJECT MANAGER. 15. CONTRACTOR CAN PROVIDE ONE OF THE FOLLOWING AS DIRECTED BY THE PROJECT MANAGER: THE SECOND OPTION IS PREFERRED. A CADWELD EACH CABINET GND WIRE TO GND RING AS SHOWN IN EQUIPMENT GND DETAIL B. CADWELD EACH WIRE TO A 1/4'X4'X24' MIN. COPPER BUS BAR LOCATED BEHIND RADIO CABINET. EXTEND A #2 WIRE FROM EACH END OF COPPER BUS BAR TO GND RING. 16. PROVIDED BRAIDED BONDING JUMPERS BETWEEN EACH GATE AND POST (OPTIONAL). 17. CONTRACTOR SHALL. PROVIDE EXOTHERMIC BONDING AT ALL BURIED GROUND RING CONNECTIONS, STRUCTURAL EQUIPMENT FRAME, SERVICE RACK(S), EXISTING TOWER. GROUND RINGS, AND AS INSTRUCTED BY T-MOBILE CPM. 18 CONTRACTOR SHALL PROVIDE MECHANICAL BONDING AT ALL ANTENNA SECTOR GROUND BARS, ALL ELECTRICAL EQUIPMENT DISCONNECTS, TRANSFORMERS, J-BOXES, PANEL - BOARDS, CABINETS, AND MAIN GROUND BAR AS DIRECTED DY T-MOBILE CPM. ALL MECHANICAL CONNECTIONS SHAD. BE PROPERLY TERMINATED W/ LUGS, NUTS & BOLTS. 19 CONTRACTOR SHALL COAT WITH NOX-OX ALL POINTS OF CONTACT BETWEEN DISSIMILAR METALS. EXISTING PPC CABINET WIRE I COND I BUS AMPS I BUS BUS AMPS WIRE CONE) SIZE SIZE L1 LOAD POLES AMPS L1 AMPS POLES LOAD L1 SIZE SIZE NOTE PROPOSED 1-POLE 20A BWAX R IN POSMDN 14 FOR PROPOSED LED L1G1T NOTE RE -USE E]05 M 4-POLE 200A BRANCH BREAKER TO POSITIONS 9. 11. 11 & 15 FOR PROPOSED 6180 G9NL7 RATED VOLTAGE: N 120/240 ❑ 1 PHASE, 3 WIRE BRANCH POLES:❑12 ❑16 024 ❑42 RATED AMPS: ❑ 100 ■200 ❑400 ❑ CABINET: N PEDESTAL [ISURFACE NEMA Ell E3R ❑4X []MAIN LUGS ONLY MAIN AMPS N BUSED SWITCH BREAKER ❑ F ■ HINGED DOOR N KEYED DOOR LATCH El FUSED IN CIRCUIT BREAKER BRANCH DEVICES ❑ TO BE GF :1 BREAKERS FULL NEUTRAL BUS I GROUND BUS ALL BREAKERS MUST BE RATED TO INTERRUPT A SHORT CIRCUIT ISC OF 10,000 AMPS SYMMETRICAL GROUNDING NOTES NTS 11 1 PANEL BOARD A PPC CABINET N,S 121 GRADE - • REMOVABLE COVER ......e 1 I I 6'(w) x 20'(1) PVC 12 AWG BARE TINNED SOLID CO WIRE FOR MEGGER SEN TES 18' CADWELD TO ROD CRUSHED ROC AT BASE SLOT FOR GROUND WIRE CADWELD CONNECTION TO GND RING, TYP. J2 AWG BARE 5/8'XlO' COPPERC TINNED SOLID COPPER WIRE NOTE: CONTRACTOR TO MARK ON INTERIOR OF SLEEVE WHICH BUILDING GROUND OR TELEPHONE GROUND IS TIED INTO INSPECTION SLEEVE NOTE: NOTE ALL SECTOR GROUND BARS CONTRACTOR TO APPLY COPPERSHIELD SHALL BE 1/4'X2'X12` COPPER OR NO-OX TO ALL CONNECTIONS AND / PLATES 3/8 THREADED INSULATOR 3/8 It 3/4 SS BOLT (NOT USED FOfZ ACTOR GROUND BARS) i 3/8 GALV. . SCREWS 1/4x4x24 BUS BAR MTS 6 000 NOTE CONTRACTOR TO COORD. a a ° ° o Ij a / GROUND BAR SIZE REQUIREMENTS / ° o a a ° ° o a a / FOR SECTOR AND MAIN GROUND BARS WITH T-MOBILE CPM ° 1.1 /4- U-FITTING 3/8 SS LOCK WASHER 3/80/4 SS BOLT #2 AWG TINNED WIRE LEAD WITH EXOTHERMIC 'SS ANGLE ADAPTER LEAD SHOWN FOR CLARITY TYPICAL GROUND BAR DETAIL Ida d—t..e t��too{y{aatl�c min, Na cvn.spla and dNynv p,ea - 1� 1 ae mi h iCy'i It ova 1pe�arad. 1. I,Ite u'. y,i" Na v95% puepvva and d- I. I i—t .dttan aaua<cauan m,d mIwtau°�m4ey`dimh ,y*un me ae�Ia.. i- — a —t noedity I. x I,y-+I= and "d,tm 1— NOTE: ALL EXPOSED CONDUCTORS ON EQUIP. SLAB SHALL INSTALLED INSIDE A 1/2- SCHED 80 PVC CONDUIT, WHETHER OR NOT CALLED OUT HERE ANTENNAS SECTORS WITH SECTOR GROUND BARS MOUNTED AT TOP OF TOWER. OR AS CAU-ED OUT IN PLANS NOTE: SECTOR GROUND BARS ARE TO BE MOUNTED DIRECTLY TO TOWER. WITH NO INSULATORS. POWER TELCO CABINET - METER DISC NTb 3 IOI Go NOTE ALL BONDING TO ANTENNA SECTOR GROUND BAR IS MECHANICAL, FURNISH LUGS AND HARDWARE PROPOSED B160 CABINET #2 BARE TINNED - SOLID COPPER TINNED MAIN GROUND D BUS BAR COAX CABLE SHIELD GROUNDING KIT (TYP) FAWG GREEN JACKETED COPPER WIRE FOR BONDING OF RF COAX CABLE SHIELD & ANTENNA SUPPORT STRUCTURE ANTENNA (TIP) ANTENNA SUPPORT STRUCTURE (TYP) RF COAX CABLE TO RF ANTENNA NOTE IRREVERSABLE CRNPING ALLOWED. RF CDAX CABLE GROUNDING ITT, TYP 12CU TINNED SOLID GROUND CONDUCTOR EXTEND TO ICEHRIDGE SUPPORT STRUCTURE & CADWELD AT TWO LOCATIONS MINIMUM SOLID COPPER GROUND RING — z C-==---- -- ---- r - 6FT MIN. GROUND ROD WITH INSPECTION SLEEVE TIE INTO EXISTING (TYPICAL) TOWER GROUND RING EXISTING TOWER GROUND ROD (COORDINATE WITH CPM) GROUNDING SERVICE ENTRANCE 12 BARE TINNED SOLID COPPER FOR GROUND RING, 18- BELOW GRADE MIN. :'.'-)DE COMPLIANCE z Lyll UCIE COUNTY 1130c NTS 14I GROUNDING RISER DIAGRAM NTS 15 T • Mobile •- 1300 CONCORD TERRACE, SUITE 200 SUNRISE FL, 33323 PROJECT INFORMATION: PJD/FOX SITE A2PO105A 5D41 ST LUCIE BOULEVARD FORT PIERCE, FL 34946 Sr. LUCIE COUNTY URRENT ISSUE DATE- APRIL 2021 SSUED FOR: EXCALIBUR EV.:=DATE:===DESCRIPTION: SEAL: w6,Iiv ' ftA71+tb� LANS PR Kimli orn © 2021 KIMLEY--HORN AND ASSOCIATES, INC. 1920 WEKIVA WAY, SUITE 200 WEST PALM BEACH, FLORIDA 33411 (561) 845-0665 FSPE REGISTRY NO. 696 ROVIDER: RAWN BY:=CHK.- APV.: GD LF CMM CENSURE: KEVIN K. MARAJH PE 71455 MARIA VICTORIA MARTIN PE 72397 CHELSEA M. MARAJH PE 84300 HEET TITLE EQUIPMENT GROUNDING DETAILS HEET NUMBER•REVISION E=2__ KHA Job #: 044290553