Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProject InformationDuct System Summary Job: 000 BelleairAve 1650B RR..
- wrightsofto Date: 03/20/2020
House W. LVL
One Stop Cooling and Heating
7225 Sandsoove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: v w .OneStopCooling.mm License: CAC1817652
For: WADE JURNEY
FL
External static pressure
Pressure losses
Available static pressure
Supply/return available pressure
Lowest fridon rate
Actual airflow
Total effective length (TEL)
Heating
0 in H2O
0.16 in H2O
-0.2 in H2O
-0.080 / -0.080 in H2O
-0.12 in/100ft
0 cfm
128
Cooling
0.50 in H2O
0.16 in H2O
0.34 in H2O
0.170 / 0.170 in H2O
0.265 in/100ft
740 dim
Name
Design
(Btuh)
Htg
(Ctm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Dud
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BA2
c 370
0
18
0.311
4.0
0x 0
VIFx
14.2
95.0
st2
BED2
C 2127
0
104
0.300
6.0
Ox0
VIFx
18.3
95.0
st2
BED3
c 1481
0
72
0.295
6.0
Ox0
VIFx
15.4
100.0
st2
BED4
c 1352
0
66
0.282
6.0
Ox 0
VIFx
20.5
100.0
st2
FLEX
c 1192
0
58
0.288
6.0
Ox0
VIFx
22.9
95.0
SO
KIT
c 2265
0
110
0.276
6.0
Ox0
VIFx
28.1
95.0
st1
Llv
c 2865
0
140
0.281
7.0
Ox0
VIFx
26.2
95.0
st1
MBA
c 323
0
16
0.290
4.0
Ox 0
VIFx
22.2
95.0
SO
MBED
c 1579
0
77
0.305
6.0
Ox 0
VIFx
21.6
90.0
st1
MWIC
c 755
0
37
0.265
4.0
Ox 0
VIFx
33.1
95.0
st1
WIC 1
c 863
0
42
0.313
4.0
Ox 0
VIFx
13.7
95.0
st2
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(chn)
(cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st1
PeakAVF
0
438
0.265
558
12.0
0 x 0
VinlFlx
st2
PeakAVF
0
302
0.282
554
10.0
0 x 0
VinlFlx
wrightsoft- 2021-Jan-25 08:58:00
Right -Suite® Universal 2019 19.0.20 RSU16877 Page 1
ACCA ...1650E RHG-WCI000 Belleau Are 16508 RHG-WC.rut Calc= MJ8 House faces: NW
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
0m)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mat
Trunk
rb1
Ox 0
0
740
0
0
0
0
Ox 0
VIFx
nightseft ° 2021-Jan-25 08:58 00
�,,,,,, „„ Right RSU16877 page 2
...1650E RHG-WCt000 Belleair Fie 1650E RHG-WC.rut Calc= MJ8 House faces: NW
Static Pressure and Friction Rate Job: 000 BeIIeairAve 1650B RH...
' Wrightsoft° Date: 03/20/2020
House LVL
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: v vw.0neSlopCooling.com License: CAC1817652
Project• •
For. WADE JURNEY
FL
Available Static Pressure
Heating
Cooling
(in H2O)
(in H2O)
External static pressure
0
0.50
Pressure losses
Coil
0
0
Heat exchanger
0
0
Supply diffusers
0.03
0.03
Return grilles
0.03
0.03
Filter
0.10
0.10
Humidifier
0
0
Balancing damper
0
0
Other device
0
0
Available static pressure
-0.2
0.34
Total Effective Length
Supply Return
(ft) (ft)
Measured length of run -out 18 0
Measured length of trunk 16 0
Equivalent length of fittings 95 0
Total length 128 0
Total effective length 128
Supply Ducts
Return Duds
Friction Rate
Heating
(i n/100ft)
-0.125 < 0.06
-0.125 <0.06
Fitting Equivalent LengthDetails
Supply 4X=35,11A=20,11G=5,1A=35:Total EL=95
Return TotalEL=0
Cooling
(in/100ft)
0.265 >0.18
0.265 > 0.18
wrightsoft" 2021-Jan-25 08:58:00
^1 am RightSuite®Universal 201919.0.20 RSU16877 page 1
ACCP....1650B RHG-WC1000 Belleair Are 1650E RHG-WC.rut Calc= MJ8 House faces: NW
4" Dryer Duct to Roof
Cap wlDryer Vent Box
Level 1
UV KIT MVUIC
1ox1o•2w
110 cfm \
10x8 80
37 dm
140 dm
6"
7 " MBA 4" 4" Bath Duct to Roof Man
FLEX
F Broan 16B8F
50 CFM
6 ° 6. 77 dm
SRB 1 10X6 4 "
10X6 MBED
58 dm 24 x 4
12" 16dm
8x4 24 x 4 10 6
10x6
I
72 dm
2414 RA
BED 3
740 cfm
24x4
6„\
10
4" Bath Duct to Roof WIFan
18 dm
Broan 168BF
F
BA2
50CFM
6"/
24x4
104 cfm
FOY
10x6
BED 2
x
LAUN dmC66
A/C-1:20TCN14.0SEER H.P.WIC1 BED a ACSLAB BYBUILDER
2 FROM WALL
2.0ton W15KW@240V 1PH
14X14 Plen
ON AHU STAND
GAR
Job M 000 Belleair Ave 1650B RHG-WC Scale: 1 :38
Performed by LVL for One Stop Cooling and Heating. Page 1
WADE JURNEY 7225 Sarxiscove Court Right -Suite® Universal 2019
Winter Park, FL 32792 19.0. an 25 08:5 :4
2021,1an-25 08:59:45
FL Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 00 BelleairAve 1650B RHG-WC.rut
www.OneStopCooling.com