Loading...
HomeMy WebLinkAboutProject InformationDuct System Summary Job: 000 BelleairAve 1650B RR.. - wrightsofto Date: 03/20/2020 House W. LVL One Stop Cooling and Heating 7225 Sandsoove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: v w .OneStopCooling.mm License: CAC1817652 For: WADE JURNEY FL External static pressure Pressure losses Available static pressure Supply/return available pressure Lowest fridon rate Actual airflow Total effective length (TEL) Heating 0 in H2O 0.16 in H2O -0.2 in H2O -0.080 / -0.080 in H2O -0.12 in/100ft 0 cfm 128 Cooling 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.170 / 0.170 in H2O 0.265 in/100ft 740 dim Name Design (Btuh) Htg (Ctm) Clg (cfm) Design FIR Diam (in) H x W (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA2 c 370 0 18 0.311 4.0 0x 0 VIFx 14.2 95.0 st2 BED2 C 2127 0 104 0.300 6.0 Ox0 VIFx 18.3 95.0 st2 BED3 c 1481 0 72 0.295 6.0 Ox0 VIFx 15.4 100.0 st2 BED4 c 1352 0 66 0.282 6.0 Ox 0 VIFx 20.5 100.0 st2 FLEX c 1192 0 58 0.288 6.0 Ox0 VIFx 22.9 95.0 SO KIT c 2265 0 110 0.276 6.0 Ox0 VIFx 28.1 95.0 st1 Llv c 2865 0 140 0.281 7.0 Ox0 VIFx 26.2 95.0 st1 MBA c 323 0 16 0.290 4.0 Ox 0 VIFx 22.2 95.0 SO MBED c 1579 0 77 0.305 6.0 Ox 0 VIFx 21.6 90.0 st1 MWIC c 755 0 37 0.265 4.0 Ox 0 VIFx 33.1 95.0 st1 WIC 1 c 863 0 42 0.313 4.0 Ox 0 VIFx 13.7 95.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (chn) (cfm) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 0 438 0.265 558 12.0 0 x 0 VinlFlx st2 PeakAVF 0 302 0.282 554 10.0 0 x 0 VinlFlx wrightsoft- 2021-Jan-25 08:58:00 Right -Suite® Universal 2019 19.0.20 RSU16877 Page 1 ACCA ...1650E RHG-WCI000 Belleau Are 16508 RHG-WC.rut Calc= MJ8 House faces: NW Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg 0m) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox 0 0 740 0 0 0 0 Ox 0 VIFx nightseft ° 2021-Jan-25 08:58 00 �,,,,,, „„ Right RSU16877 page 2 ...1650E RHG-WCt000 Belleair Fie 1650E RHG-WC.rut Calc= MJ8 House faces: NW Static Pressure and Friction Rate Job: 000 BeIIeairAve 1650B RH... ' Wrightsoft° Date: 03/20/2020 House LVL One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: v vw.0neSlopCooling.com License: CAC1817652 Project• • For. WADE JURNEY FL Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0 0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure -0.2 0.34 Total Effective Length Supply Return (ft) (ft) Measured length of run -out 18 0 Measured length of trunk 16 0 Equivalent length of fittings 95 0 Total length 128 0 Total effective length 128 Supply Ducts Return Duds Friction Rate Heating (i n/100ft) -0.125 < 0.06 -0.125 <0.06 Fitting Equivalent LengthDetails Supply 4X=35,11A=20,11G=5,1A=35:Total EL=95 Return TotalEL=0 Cooling (in/100ft) 0.265 >0.18 0.265 > 0.18 wrightsoft" 2021-Jan-25 08:58:00 ^1 am RightSuite®Universal 201919.0.20 RSU16877 page 1 ACCP....1650B RHG-WC1000 Belleair Are 1650E RHG-WC.rut Calc= MJ8 House faces: NW 4" Dryer Duct to Roof Cap wlDryer Vent Box Level 1 UV KIT MVUIC 1ox1o•2w 110 cfm \ 10x8 80 37 dm 140 dm 6" 7 " MBA 4" 4" Bath Duct to Roof Man FLEX F Broan 16B8F 50 CFM 6 ° 6. 77 dm SRB 1 10X6 4 " 10X6 MBED 58 dm 24 x 4 12" 16dm 8x4 24 x 4 10 6 10x6 I 72 dm 2414 RA BED 3 740 cfm 24x4 6„\ 10 4" Bath Duct to Roof WIFan 18 dm Broan 168BF F BA2 50CFM 6"/ 24x4 104 cfm FOY 10x6 BED 2 x LAUN dmC66 A/C-1:20TCN14.0SEER H.P.WIC1 BED a ACSLAB BYBUILDER 2 FROM WALL 2.0ton W15KW@240V 1PH 14X14 Plen ON AHU STAND GAR Job M 000 Belleair Ave 1650B RHG-WC Scale: 1 :38 Performed by LVL for One Stop Cooling and Heating. Page 1 WADE JURNEY 7225 Sarxiscove Court Right -Suite® Universal 2019 Winter Park, FL 32792 19.0. an 25 08:5 :4 2021,1an-25 08:59:45 FL Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 00 BelleairAve 1650B RHG-WC.rut www.OneStopCooling.com