Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, revision 1ENERGY LOT 41
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-EMERALD Builder Name: KHOVNANAIN HOMES Street: 5149 ARMINA PL. Permit Office: City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: EMERALD MODEL LOT 41 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV508.8 sgft.) Insulation Area 2. Single family or multiple family Detached a. Frame - Wood, Exterior Ill 1.0 1180.70 ft2 3. Number of units, if multiple family 1 b. Concrete Block - int Insul, Exterior ll 973.39 ft2 c. Frame - Wood, Adjacent Ill 1.0 354.67 ft2 4. Number of Bedrooms 5 d. NIA R_ ft2 5. Is this a worst case? No 11. Ceiling Types (1354.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1354.00 ft2 6. Conditioned floor area above grade (ft2) 2321 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(194.0 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.30 152-00 ft2 a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT 6 250 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=0.55 42.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.34 a. Central Unit 46.5 SEER:16.00 c. U-Factor. NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.165 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.293 a. Electric Strip Heat 32.0 COP:1.00 8. Skylights Area c. U-Factor. (AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1354.1 sgft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 968.10 ft2 b. Conservation features b. Raised Floor R=11 A 386.00 ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.084 Total Proposed Modified Loads: 70.47 PASS Total Baseline Loads: 71.88 hereby certify that the plans and specil cations covered by Review of the plans and 11 S7 this calculation are in compliance with ti e Florida specifications covered by this, O 7ergy Code. calculation indicates compliance,,, With the Florida Energy Code. rF,r,'€<<•, '=`';;;;�•'*„ 4 PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes., with the Florida Energy Code. 000 OWNERIAGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/27/2021 12:35 PM EnergyGaugvD USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 PUT SU hMARY CHECKLI. PROJECT Title: KHOV-EMERALD Bedrooms: 5 Building Type: User Conditioned Area: 2321 Owner Name: EMERALD MODEL LOT 41 Total Stories 2 # of Units: 1 Worst Case: No Builder Name: KHOVNANAIN HOMES Rotate Angle: 0 Permit office: Cross Ventilation: No Jurisdiction: Whole House Fan: No Family Type: Detached NewlExisting: New (From Plans) Comment: CLIMATE / Design Temp V Design Location TMY Site 97.5 % 2.5 % FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 BLOCKS Number 1 Number 1 2 3 4 5 6 7 8 9 10 11 12 13 Address Type: Street Address Lot # BlocklSubdivision: PlatBook: Street: 5149 ARM INA PL. County: St. Lucie City, State, Zip: FORT PIERCE, FL, Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range 70 75 299 62 Low Name Area Volume Entire House 2321 19341.6 SPACES Name Area Volume Kitchen Occupants Bedrooms EXTRA SUITE 144 1267.2 No 2 5 EX SUITE BATH 60 528 No 0 FOYER 133 1173 No 0 GRT DIN KITCHEN 630 5544 No 1 BED 4 174 1392 No 1 BED 3 167 1334 No 1 BED 2 162 1296 No 1 HALL LOFT 350 2800 No 0 LAUNDRY 48 384 No 0 MASTER SUITE 224 1792 No 2 MAST WIC 60 476 No 0 MASTER BATH 104 832 No 0 HALL BATH 65 518 No 0 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area 1 Slab -On -Grade Edge Insulatio EXTRA SUITE 24 ft 0 144.8 ft2 2 Slab -On -Grade Edge Insulatio EX SUITE BATH 6 ft 0 60 ft2 3Slab-On-Grade Edge Insulatio FOYER 20.5 ft 0 133.3 ft2 4Slab-On-Grade Edge Insulatio GRT DIN KITCHE 89 ft 0 630 ft2 InfilID Finished Cooled Heated 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes 1 No Yes Yes Joist R-Value Tile Wood Carl 0 1 0 0 1 0 1 0 0 0.6 0.5 0 7/27/2021 1235 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Raised Floor BED 4 ---- --__ 174 ft2 11 0 0 1 6 Raised Floor BED 3 -___ _--- 167 ft2 11 0 0 1 7 Raised Floor HALL LOFT ---- ---- 45 ft2 11 0 0 1 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1466 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 22.62 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1353 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BED 4 30 Blown 174 ft2 0A Wood 2 Under Attic (Vented) BED 3 30 Blown 167 ft2 0.1 Wood 3 Under Attic (Vented) BED 2 30 Blown 162 ft2 0.1 Wood 4 Under Attic (Vented) HALL LOFT 30 Blown 350 ft2 0.1 Wood 5 Under Attic (Vented) LAUNDRY 30 Blown 48 ft2 0A Wood 6 Under Attic (Vented) MASTER SUITE 30 Blown 224 ft2 0A Wood 7 Under Attic (Vented) MAST WIC 30 Blown 60 ft2 0.1 Wood 8 Under Attic (Vented) MASTER BATH 30 Blown 104 ft2 0.1 Wood 9 Under Attic (Vented) HALL BATH 30 Blown 65 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 E Exterior Concrete Block - Int In5®XTRA SUIT 4.1 10 8 9 4 99.6 ft2 0 0 0.5 0 2 S Exterior Concrete Block - Int Ins1flXTRA SUIT 4.1 11 8 10 0 116.7 ft2 0 0 0.5 0 3 S Exterior Concrete Block - Int InsEK SUITE BA 4.1 5 5 10 0 54.2 ft2 0 0 0.5 0 4 E Exterior Concrete Block - Int Insul FOYER 4A 6 9 9 4 63.0 ft2 0 0 0.5 0 5 N Exterior Concrete Block - Int InsORT DIN KIT 4.1 17 5 9 4 162.6 ft2 0 0 0.5 0 6 S Exterior Concrete Block - Int InsIMRT DIN KIT 4A 16 2 10 0 161.7 ft2 0 0 0.5 0 7 W Exterior Concrete Block - Int InsGRT DIN KIT 4.1 33 10 9 4 315.8 ft2 0 0 0.5 0 8 N Exterior Frame - Wood BEd 4 11 13 8 8 10 120.7 ft2 0 0 0.5 0 9 E Exterior Frame - Wood BED 4 11 10 11 8 10 96.4 ft2 0 0 0.5 0 10 E Exterior Frame - Wood BEd 3 11 10 11 8 10 96.4 ft2 0 0 0.5 0 11 E Exterior Frame - Wood BED 2 11 10 11 8 10 96.4 ft2 0 0 0.5 0 12 S Exterior Frame - Wood BED 2 11 12 3 8 10 1082 ft2 0 0 0.5 0 13 N Exterior Frame - Wood HALL LOFT 11 7 3 8 10 64.0 ft2 0 0 0.5 0 7/27/2021 12:35 PM EnergyGaugep USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SLIMMARY nH1=r4CI IAT RFPnRT WALLS Adjacent Space Cavity Width Ft In Height Ft In A�ea Sheathing Framing R--Vallle Solar Below 0 14 S Exterior Frame - Wood HALL LOFT 11 12 9 8 10 112.6 ft2 0 0 0.5 0 15 N Exterior Frame - Wood MASTEI? SUI 11 13 2 8 10 116.3 ft2 0 0 0.5 0 16 W Exterior Frame - Wood MASTER SUI 11 14 7 8 10 128.8 ftz 0 0 0.5 0 17 W Exterior Frame - Wood MASTER BA 11 11 10 8 10 104.5 ft2 0 0 0.5 0 18 S Exterior Frame - Wood HALL BATH 11 10 0 8 10 88.3 ft2 0 0 0.5 0 19 W Exterior Frame - Wood HALL BATH 11 5 5 8 10 47.8 ft2 0 0 0.5 0 _20 W Garage Frame - Wood GRT DIN KIT 11 38 0 9 4 354.7 ft2 4 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated FOYER None .39 3 4 6 8 22.2 ftz 2 E Wood FOYER None .39 3 4 6 8 22.2 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 12 ft 0 in None None 2 W 7 Metal Double (Tinted) Yes 0.3 0.28 N 32.0 ft2 1 ft 0 in 12 ft 0 in None None 3 W 7 Metal Double (Tinted) Yes 0.55 0.34 N 42.0 ft2 11 ft 0 in 1 ft 0 in None None 4 E 9 Metal Double (Tinted) Yes 0.3 0.28 N 16_0 ft2 1 ft 0 in 1 ft 0 in None None 5 E 10 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 6 E 11 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 7 N 13 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 8 S 14 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft' 1 ft 0 in 1 ft 0 in None None 9 W 16 Metal Double (Tinted) Yes 0.3 0.28 N 30.0 ft' 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 386 ft' 386 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SL.A CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .00037 2255.9 123.76 232.35 .1694 7 7/27/2021 12:35 PM EnergyGaugeD USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHFCKI IRT QFPnRT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 32 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 46.6 kBtulhr cfm 0.74 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / ---- Supply --- ---- Return --- Air CFM 25 CFM25 HVAC # V/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT 4N RLF Heat Cool 1 Attic 6 250 ft2 HALL LOFT 1 ft2 Default Leakage HALL LOFT (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cool in Jan Feb [[ Mar HeatingJanlFeb [X Mar �Xj A r Apr Ma X Jun X Jul rj Au X Se MayJun Juf AuSep�Xj Oct Nov Oct XNov Dec XDec Venting Jan [ ] Feb [X Mar [X Apr [ May [ Jun Jul Aug Se Oct [X Nov j j Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BED 3 Default(8 Ibs/sq.ft. ft2 ft 0-3 POWDER Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC BED 3 Default(8 lbs/sq.ft. ft2 ft 0.3 SUITE 2 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC BED 2 Default(8 tbs/sq.ft. ft2 ft 0.3 BATH BED 2 Default(8 lbs/sq.ft. ft2 ft 0.3 GALLERY 7/27/2021 12:35 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Default(8 Ibs/sq.ft. ft2 ft 0.3 Default(8 Ibslsq.ft. ft2 ft 0.3 Default(8 Ibsfsq.ft. ft2 ft 0.3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Default(8 Ibslsq.ft. ft2 ft 0.3 Default(8 Ibs/sq.ft, ft2 ft 0.3 Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY LIBRARY DINING KITCHEN CASUAL DINING GREAT ROOM MASTER WIC MASTER BATH MASTER SUITE 7/27/2021 12:35 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 5149 ARMINA PL., FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Frame -Wood, Exterior R=11.0 1180.70 ft2 b. Concrete Block - Int Insul, Exterior R=4.1 973.39 ftZ 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 354.67 ft2 4. Number of Bedrooms 5 d. NIA R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1354.00 ft2 6. Conditioned floor area (ft2) 2321 b. NIA R= ft2 7. Windows- Description Area c. NIA R= ftZ a. U-Factor: Dbl, U=0.30 152A0 ft2 12. Ducts, location & insulation level R ftz SHGC: SHGC=0.28 a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT 6 250 b. U-Factor: Dbl, U=0.55 42.00 ft2 SHGC: SHGC=0.34 13. Cooling systems kBtulhr Efficiency c. U-Factor: NIA ft2 a. Central Unit 46.5 SEER:16.00 SHGC: d. U-Factor; NIA ft2 SHGC: 14. Heating systems kBtulhr Efficiency Area Weighted Average Overhang Depth: 3.165 ft. a. Electric Strip Heat 32.0 COP:1.00 Area Weighted Average SHGC: 0.293 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): NIA ft2EF. a. Electric Cap: 50 gallons SHGC(AVG): NIA 0 95 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=M 968.10 ft2 Credits (Performance method) Pstat b. Raised Floor R=11.0 386.00 ftZ c. NIA R= ftZ I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: 144ESr �1.+�� .Jbfr�4•. _ .,.4 G WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 712712021 12:35 PM EnergyGaugeQ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 Project Summary Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954,421-4117 Fax: 954-420-0064 Web: www.lindstromaircom For: KHOVNANIAN HOMES Notes: LOT 41 EMERALD MODEL Desi-pin Information Weather: Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 21178 Btuh Ducts 3754 Btuh Central vent (108 cfm) 3336 Btuh Outside air Humidification 0 Btuh Pi In Equipment load 28269 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Area (ftz) Heating Cooling 2321 2321 Volume (W) 19343 19343 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 103 52 Heating Equipment Summary Make CARRIER Trade Model 10 KW AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.6 kW 25981 Btuh 15 OF 1600 cfm 0.064 cfm1Btuh 0 in H2O Job: Date: 6-2021 By: LINDSTROM Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range M Relative humidity 50 %fl Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 22956 Btuh Ducts 7217 Btuh Central vent (108 cfm) 1787 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 30362 Btuh Latent Cooling Equipment Load Sizing Structure 37555 Btuh Ducts 2153 Btuh Central vent (108 cfm) 4529 Btuh Outside air Equipment latent load 10437 Btuh l Load ( 40799 h Req. total capuipment acity at 0.74 SHRat) ton Cooling Equipment Summary Make CARRIER Trade Cond CA16NA048 Coil FX4DNF049 AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16 SEER 34200 Btuh 12300 Btuh 46500 Btuh 1600 cfm 0.053 cfm1Btuh 0 in H2O 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoftm 2021-Jul-2712:44:06 -,.,,.a•,u.. •_• _• ••-.- ,, Right -Suite® Universal 2019 19.0,12 RSU08398ACCK Page 1 ..OJECTS ENERGYIA- MANUAL JIKHOV-EMERALO-PSTL.rup Calc = MJ8 Front Door faces: N t... Right-JO Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromaircom Job: Date: 6-2021 By: LINDSTROM 1 Room name Entire House EXTRA SUITE 2 Exposed wall 145.0 ft 24.0 ft 3 Room height 8.3 tt 8,8 ft heaUcoal 4 Room dimensions 11.0 x 13.2 ft 5 Room area 2321.0 ft2 144.8 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-OF) (BtuNftg or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WPIS Heat Cocl Gross NIPS Heat Cool 6 1213-0sw 0,097 n 2.72 2,34 300 285 774 666 0 0 0 0 1D-h2om 0.870 n 0.00 0,00 0 0 0 0 0 0 0 0 1D-h2om 0,870 n 24.36 22.27 15 0 365 334 0 0 0 0 W 13A-4ocs 0.143 n 4.00 2,19 162 162 649 354 0 0 0 0 11 1213-0sw 0,097 e 272 2.34 288 243 660 568 0 0 0 0 � ID-h2om 0.870 e 0.00 0,00 0 0 0 0 0 0 0 0 1D-h2om 0.870 e 24.36 65.33 45 0 1096 2490 0 0 0 0 13A-4ocs 0.143 e 400 2.19 143 106 424 232 99 84 336 184 1D-h2om 0.870 e 24.36 55.33 15 0 365 830 15 0 365 830 11 DO 0390 e 10.02 10.34 22 22 240 227 0 0 0 0 W 1213-0sw 0.097 s 2.72 2.34 308 293 796 685 0 0 0 0 1 D-h2om 0.870 s 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.370 s 24. 36 22.27 15 30 365 334 0 0 0 0 W 13A-40cs 0.143 s 4.00 2.19 333 333 1333 729 117 117 468 256 1$! 1213-9sw 0.097 w 2.72 2.34 280 250 679 584 0 0 0 0 1 D-h2om 0.870 w 0.00 0,00 0 0 0 0 0 0 0 0 1 D-h2om 0,870 w 24.36 55.33 30 0 731 1660 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 315 241 965 527 0 0 0 0 1 D-h2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 32 0 780 1771 0 0 0 0 ID-h2omd 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 w 24.36 22.27 42 84 1023 936 0 0 0 0 1211-0sw 0.097 - 2.72 1.33 347 325 883 432 0 0 0 0 11 DO 0.390 n 10.92 10.34 22 22 240 227 0 0 0 0 C 16B-30ad 0.032 e 0.90 1.60 1353 1353 1212 2185 0 0 0 0 F 19A-llbscp 0.073 1.45 0.78 386 386 559 299 0 0 0 0 F 22A tpl 0.989 27.69 0.00 968 140 3863 O 145 24 665 0 6 C) AED excursion 1215 -86 Envelope loss/gain 18004 17266 1835 1184 12 a) Infiltration 3175 850 322 86 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 8 1840 2 460 Appliances/other 3000 0 SLbt0t21 (lines 6 to 13) 21178 22956 2157 1730 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 21178 22956 2157 1730 15 Duct loads 18% 31% 3754 7217 -0% 0% 0 0 Total room load 24932 30173 2157 1730 Air required (cfm) 1600 1600 138 92 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. vwrYgF'ts ,- t® 2021-Jul-27 12:43:42 Right-SuiteO Universal 2019 19.0.12 RSU083% Page 1 ...OJECTS ENERGYSA- MANUAL J%KHOVEMERALD-PSTL.rup Ca{G = MJ8 Front Door faces: N Right-J® Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH. FL 33069 Phone: 954-421-4117 Fax, 954-420-0064 Web: www.3indstromair.com Job: Date: 6-2021 By: LINDSTROM 1 Room name EX SUITE BATH FOYER 2 Exposed wall 6.0 ft 26.0 ft 3 Room height 8,8 ft heat/cool 8.8 ft heat/cool 4 Room dimensions 10.0 x 6.0 ft 20.6 x 6.5 ft 5 Room area 60.0 ft2 133.3 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuhfft2- °F) (Btuhlft2 or perimeter (ft) (Btuh) or perimeter (ft) (13tuh) Heat Cool Grass NIPlS Heat Cool Gross NIP/S Heat Cool 6 126-osw 0.097 n 2.72 2.34 0 0 0 0 0 0 0 0 1D-h2om 0.870 n 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 11 1213-0sw 0.097 e 2.72 2.34 0 0 0 0 0 0 0 0 ID-h2om 0.870 e 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2om 0.870 e 24.36 55.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 e 4.00 2-19 0 0 ❑ 0 44 22 88 48 ti ID-h2orn 0.870 e 24.36 55.33 0 0 0 0 0 0 0 0 11 DO O, 390 e 10.92 10.34 0 0 0 0 22 22 240 227 12B-❑sw 0.097 s 2.72 2.34 0 0 0 0 0 0 0 0 1iJ-h2om 0.870 s 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0 w 13A- ocs 0.143 s 4.00 2.19 54 54 216 118 0 0 0 0 l7J 12B-Osw 0.097 w 2.72 2.34 O 0 0 ❑ 0 0 0 0 ID-h2om 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1D h2om - 0.870 w 24.36 55.33 0 0 0 0 0 b 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 ID-h2om 0.870 w 0.00 0.00 0 ❑ 0 0 0 0 0 0 ID-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 ID-h2omd 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 w 24.36 22.27 0 C 0 0 0 0 0 0 12B-0sw 0.097 - 2.72 1.33 0 0 0 0 185 185 502 246 1100 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 a 0.90 1.60 0 0 0 0 0 0 0 0 F 19A-llbscp 0.073 - 1.45 0.78 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 27.69 0.00 60 6 166 0 133 21 568 0 6 c) AED excursion -12 -46 Envelope Iosslgain 382 106 1398 475 12 a) Infiltration 81 22 66 18 b) Room ventilation 0 0 0 0 13 Irdemal gains: Occupants 230 0 0 0 0 Appliances/other ❑ 0 Subtotal (lines 6 to 13) 463 128 1464 493 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 463 128 1464 493 151 Duct Icads -0% 00/0 0 0 -0% 0% 0 0 Total room load T-F4 127 1494 493 Air required (cfmj 30 7 4 26 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsaTt- 2021-Jul-27 12:43:42 M p • Right -Suite® Universal 2019 19.0.12 RSUo8398 Page 2 ...OJECTS ENERGYIA- MANUAL J\KHOV-EMERALD-PSTL_rup Calc = MJ8 Front Door faces: N CE01mN Right-J® Worksheet Job: Entire House Date: 6-2021 =EmwBy: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone; 954-421-4117 Fax: 954-420-0064 Web: www_lindStromaincom 1 Room name GIRT DIN KITCHEN BED 4 2 Exposed wall 89.0 ft 0 ft 3 Room height 8.8 ft heaticool 8.0 ft heat/cool 4 Room dimensions 350 x 18.0 ft 12.0 x 14.5 ft 5 Room area 630,0 ft' 174.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft''F) (Btuhlft� or perimeter (ft) (Bfuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N!P!S Heat Cool 6 l�! 12B-0sw 0.097 n 2.72 234 0 0 0 0 120 120 326 281 r CC 1D-h2om 0.870 n 0.00 0.00 0 0 0 0 0 0 0 0 10-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 n 4. CC 2.19 162 162 649 354 0 0 0 0 11 12B-osw 0.097 e 2.72 2.34 0 0 0 0 96 81 220 189 10-h2om 0.870 e 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2om 0.870 a 24.36 55.33 0 0 0 0 15 0 365 830 13A-40cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 ID-h2om 0.870 e 24.36 55.33 0 0 0 0 0 0 0 0 11 DO 0.390 a 10.92 10.34 0 0 0 0 0 6 0 0 IW 126-Osw 0.097 s 272 2.34 0 0 0 0 0 0 0 0 �-c� L2 ID-h2om 0.870 s 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2orn 0.870 s 24.36 22.27 0 0 0 0 0 D 0 0 W 13A-4ocs 0.143 s 4.00 2.19 162 162 649 354 0 0 0 0 12B-osw 0.097 w 2.72 2.34 0 0 0 0 0 0 0 0 ID-h2om 0.870 w 0.00 000 0 0 0 0 0 0 0 0 ID-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 315 241 965 527 0 0 0 0 1 D-h2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 32 C 780 1771 0 0 0 0 1 D-h2omd 0.870 w 0.00 0.00 0 0 0 0 O 0 0 0 1 D-h2omd 0.870 w 24.36 22.27 42 42 1023 936 0 0 0 0 128-0sw 0.097 - 2.72 1.33 162 140 380 186 0 0 0 0 11D0 0.390 n 10.92 10.34 22 22 240 227 0 0 C 0 C 1613-Wad 0.032 e 0.90 1.60 0 0 0 0 174 174 156 278 F 19A-11 bscp 0.073 1.45 0.78 0 0 0 0 174 174 252 135 F 22A tol 0,989 27.69 0.00 630 89 2465 0 0 0 0 0 6 c) AED excursion 1539 -104 Envelope losslgain 7150 5895 1319 1609 12 a) Infiltration 953 255 322 86 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 1 230 1 230 Appliances/other 1800 0 Subtota{ (lines 6 to 13) 8103 8180 1641 1925 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotai 8103 6180 1641 1926 15 Duct loads -0% 0% 0 0 42% 58% 685 1118 Total room load 8103 8180 2327 3044 Air required (cfm) 520 434 149 161 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. F wrigt�tsoit® Right -Suited Universal 2019 19.0.12 RSU08398 2021-Jul-2712A3A2Page 3 ... OJECTS ENERGY\A- MANUAL JIKHOV-EMFRALD-PSTL.rap Calc = MJB Front Door Faces: N RiOW@ Worksheet Job: :..°t.. Entire House Date: 6-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RQ, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name BED 3 BED 2 2 Exposed wall 'Ight 0 ft 0 ft 3 Room !- 8, 0 ft heat/cool a.0 ft heaticool 4 Room dimensions 11.5 x 14.5 ft 12.0 x 13.5 ft 5 Room area 166, 8 ftz 162, 0 Ft' Ty Construction U-value Or HTM Area (ftj Load Area (ft') Load number (Btuh/ft? °F) (Btuhlft� or perimeter (ft) (Btuh) or perimeter (ft) (stuh) Heat Coal Gross N/P/5 Heat Cool Gross NIPIS Heat Cool 6 126-0sw 0.097 n 2.72 2.34 0 0 0 0 0 0 0 0 10-h2om 0.870 n 0.00 0.00 0 0 0 0 0 a 0 0 10-h2om 0.870 n 24.36 2227 0 0 0 0 0 0 0 0 UV 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 11 12B-0sw 0.097 e 2.72 2,34 96 al 220 189 96 81 220 189 ID-h2om 0.870 e 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2orn 0 870 e 24.36 5533 15 C 365 830 15 0 365 830 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 ID-h2om 0.870 e 24.36 55.33 0 0 0 0 0 0 0 0 11DO 0.390 e 10.92 10.34 0 0 0 0 0 0 0 0 v�J 126-0sw 0.097 s 2.72 2.34 0 0 0 0 108 108 293 252 I; 1 D-h2om 0.870 s 0.00 0.00 0 0 0 0 0 0 0 0 GCI 1 D-h2om 0.870 s 24. 36 22.27 0 0 0 0 0 0 C 0 w 13A- ocs 0.143 s 400 2.19 0 0 0 0 0 0 0 0 vfJ 12B-Osw 0.097 w 2.72 2.34 0 0 0 0 0 0 0 C D-h2om 0,870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 13A-flocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0,870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 1 D-h2omd 0,870 w 0.00 0.00 0 0 0 0 0 0 0 0 10-h2omd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0 126 -0sw 0,097 - 2.72 1,33 0 0 0 0 0 0 0 0 D 11DC 0.390 n I&W 10.34 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 e 0.90 1.60 167 167 149 267 162 162 145 259 F 19A-11bscp 0,073 - 1,45 0,78 167 167 242 130 0 0 0 0 F 22A-tpl 0.969 - 27.69 0.00 0 0 0 0 0 0 0 0 61 c) AED excursion -74 -88 Envelope loss/gain 977 1341 1024 1443 12 a) Infiltration 143 38 304 81 b) Room ventilation 0 0 0 0 13 Internal gains' Occupants @ 230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 1120 1610 1328 1755 Less external load 0 0 0 C Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1120 1610 1328 1755 1151 Duct loads 42% 58% 468 935 42% 58% 555 1019 Total room load 1587 2545 1883 2774 Air required (cfm) 102 135 1 121 147 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigF�tsoTt® �-•�A - - -•^ -^^•^ Right -Suite® Universal 2019 19.0,12 RSU48398 2021-Jul-2712:43:42 Page 4 ... OJECT$ ENERGYIA- MANUAL AKHOV-EMERAL[7-PSTL.rup Calc = MJ8 Front Door faces: N Right-JO Worksheet Job: Entire House Date: 6-2021 .._. Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone, 954421-4117 Fax: 954-420-0064 Web: www.findstramair. Corr 1 Room name HALL LOFT LAUNDRY 2 Exposed wall 0 tt 0 ft 3 Room height 8.0 ft heaticool 8.0 ft heat/cool 4 Room dimensions 35.0 x 10.0 ft 8.0 x 6.0 ft 5 Room area 350.0 ft2 48.() ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuh/fV °F) (BtuhlW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 1213-0sw 0.097 n 2.72 2.34 64 49 133 115 0 0 0 0 1 D-h2om 0.870 n 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2om 0.870 n 24,36 22.27 15 0 365 334 0 0 0 0 W 13A-4ocs 0.143 n 4.00 2.19 0 b 0 0 0 0 0 0 11 U+JL_ 12B-Osw 0.097 e 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0.870 e 0.00 0,00 C 0 0 0 0 0 0 0 rC 1 D-h2om 0.570 e 24.36 55.33 0 0 0 0 0 0 0 0 13A-40cs 0.143 e 4.00 2.19 0 0 C 0 0 0 0 0 1D-h2om 0.870 e 24.36 55.33 C 0 0 0 0 0 0 0 11 DO 0.390 e 10.92 10.34 C 0 0 0 0 0 0 0 W 128-Osw 0.097 s 2.72 2.34 112 97 263 227 0 0 0 0 LS 1 D-h2om 0.870 s 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 s 24.36 22.27 15 15 365 334 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 12B-Osw 0.097 w 2.72 2.34 0 0 C 0 0 0 0 0 1 D-h2om 0.870 w 0.00 0.00 0 C 0 0 0 0 0 0 ID-h2orn 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 13A-40cs 0.143 w 4.00 2.19 0 C 0 0 0 0 0 0 ID-h2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2om 0.870 w 24.36 55.33 0 0 O 0 0 0 0 0 ID-h2omd 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2omd 0.670 w 24.36 22.27 0 0 0 0 0 0 0 0 Fj 12E-Osw 0.097 - 2.72 1.33 0 0 0 0 0 0 0 0 T-D 11 D0 0.300 n 10.92 10.34 0 0 0 0 0 0 0 0 C 168-30ad 0.032 a 0.90 1.60 350 35C 314 560 48 48 43 77 F 19A-llbscp 0.073 - 1.45 0.78 45 45 65 35 0 0 C 0 F 22A-tol 0.989 - 27.69 0.00 0 0 0 0 0 0 0 0 61 c) AED excursion -144 110 Envelope loss/gain 1506 1461 43 -33 12 a) Infiltration 202 70 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1200 Subtotal (lines 6 to 13) 1769 1531 43 1167 Less external load 0 0 C C Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1769 1531 43 1167 15 Duct loads 42% 58% 738 889 42% 58% 18 678 Total room load 2507 2420 61 1845 Air required (cfm) 161 1281 4 98 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr�ghlsoRw 2021-Jul-2712:43:42 �� ^• °:�_•..-^�� Right-SuRe�r Universal2019 19.0.12 RSU08398 Page 5 ..OJECTS ENERCYIA- MANUAL J1KHOV-EMERALD-PSTL.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com Job: Date: 6-2021 By: LINDSTROM 1 Room name MASTER SUITE MAST WIC 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 ft heaticool 8.0 ft heaticool 4 Room dimensions 1&0 x 14.0 ft 6.5 x TO ft 5 Room area 224.0 ft2 59.5 ft, Ty Construction U-value Or HTM Area (ftz) Load Area (ft2) Load number (Btuhlft-"F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N!P!S Heat Cool Gross N/P/S Heat Cool 6 12B-0sw 0.097 n 2.72 2.34 116 116 315 271 0 0 0 0 1 D-h2om 0.870 n 0.00 a_ 00 0 0 0 0 0 0 0 0 1D-h2om 0.870 n 24.36 22,27 0 0 0 0 0 0 0 0 W 13AAocs 0.143 n 4.CC 2.19 0 0 0 0 0 0 0 0 11 %L�1213-0sw 0.097 e 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0.870 e 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 e 24.36 55.33 0 0 C 0 0 0 0 0 yJ !�GD 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 e 24.36 55.33 0 0 0 0 0 G 0 0 11 DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 W 12B-osw 0.097 s 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0.870 s 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.670 s 24.36 22.27 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 G 0 0 1213-0sw 0.097 w 2.72 2.34 128 98 266 229 0 0 0 0 1D-h2om 0.870 w 0. CC floc 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.30 55.33 30 0 731 1660 0 0 0 0 13A-4ocs 0.143 w 4.CC 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.670 w 0.00 0.00 C 0 0 0 0 0 0 0 1 13-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 w 0. CC 0.0c O 0 0 0 0 0 0 0 1 D-h2omd 0.870 w 24.36 22.27 0 0 C 0 0 0 0 0 12B-Osw 0.097 - 2.72 1.33 0 0 0 0 0 0 0 0 11DO 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 e 0.90 1.60 224 224 201 358 60 60 53 95 F 19A-llbscp 0.073 - 1.45 0.78 0 0 0 0 0 0 0 0 F 22A-tot 0.989 - 27.69 0.0C C 0 C 0 0 0 0 0 6 c) AED excursion 4Z7 -8 Envelope losslgain 1513 2946 53 87 12 a) Infiltration 364 97 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 A ppllanceslother 0 0 Subtotal (lines 6 to 13) 1877 3503 53 87 Less external load 0 D 0 0 Less transfer 0 0 0 0 Redistribution 0 0 C 0 14 Subtotal 1877 3503 53 87 15 Duct loads 42% 58% 784 2035 42% 58% 22 51 Total room load 2660 5538 76 138 Air required (cfm) 171 2941 51 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -F�i- 2021-Jul-2712:43:42 ^-Zc� "' y Right -Suite® Universal 2019 19,0.12 RSU08398 Page 6 OJECTS ENERGYIA- MANUAL JWHOV-EMERALD-PSTL.rup Calc = MJ8 Front Door faces: N CV) AN Rigflt-J® Worksheet Job: Entire House Date: fi-2t)29 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web, wwwAndstromaircom 1 Room name MASTER BATH HALL BATH 2 Exposed wall 0 ft 0 ft 3 Roam height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 8.0 x 13.0 ft 11.0 x 5.9 ft 5 Room area 104.0 W 64.8 ft2 Ty Construction U-value Or HTM Area (ft2) Load (ft) Area z Load number (Btuhlft2 °F) (Btuhlft2) cr perimeter ft O (Btuh} or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/PIS Heat Cool 6 V 12B-0sw 0.097 n 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0.870 n 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 11 VL�12B-osw 0.097 e 2.72 2.34 0 0 0 0 0 0 0 0 1D-h2om 0.870 a 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 e 24.36 55.33 0 0 0 0 0 0 0 0 4�! 13A-4ocs 0_143 e 4.00 2.19 0 0 0 0 0 0 0 0 hG 1 D-h2om o, 870 a 24.36 55.33 0 0 0 0 0 0 0 0 p 11 DO 0.390 e 10.92 10.34 0 0 0 0 0 0 0 0 1213-0sw 0.097 s 272 2.34 0 0 0 0 88 BB 239 206 1 D-h2om 0.870 s 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 UfJ 12B-Osw 0.097 w 2.72 2.34 104 104 282 243 48 48 130 112 1 D-h2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 fl 0 0 1 D-h2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 1 D-h2omd U 870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 w 24.36 2227 0 0 0 0 0 0 0 0 D 1213-esw 0.097 2.72 1, 33 0 0 0 0 0 0 0 0 11 Do 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 e 0.90 1.60 104 104 93 166 65 65 58 104 F 19A-111bscp 0.073 - 1.45 0.78 0 0 0 0 0 0 0 0 F 22A tRl 0.989 - 27.69 0,00 0 0 0 0 0 0 0 0 6 C) AED excursion -39 -41 Envelope loss/gain 376 371 427 361 12 a) Infiltration 155 42 203 54 b) Room ventilation 0 0 0 0 13 1ntemal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 531 412 630 435 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 D 0 0 14 Subtotal 531 412 630 435 15 Duct loads 42% 580/ 222 239 42% 58% 263 253 Total room load 752 652 893 688 Air required (cfm) 48 35 57136 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i°k- 2021-Jul-27 12'AT42 Right-SuiteV Universal 2019 19.0.12 RSU08398 Page 7 ...OJECTS ENERGYW MANUAL JIKHGV-EMERALD-PSTL.rup Calc = MJ8 Front Doorfaces: N