HomeMy WebLinkAboutAPPROVED, DESIGN PRESSURE4 t
STORM E.irense p CRC 1332755
License a CGC1519801
4047 dkeechabee Blvd, Ste 106,
SMARTWest Palm Beach. 33409
Phone (561) 229-004D48
www StormStnartSE rom
of Southeast Florida
Information
Owner: Rocco Mango
Address: 3054 NW Radcliffe W A Y
Palm City, FL 34990
Building Information
Wind Zone: 170 MPH.
Exposure Category: D
Minimum Building Dimension: 6 ft.
Mean Roof Height: 22 ft.
Risk Category: 11
Design
Pressure Calculations
Opening
Location
Device
Device
Device
Positive
Max Negative
Number
LMax
zone
Width {in)
Height (in)
Elevation (ft)
Pressure (psf)
Pressure 1psfj
2
End
236.125
126 10,5
39.4
-46.3
3
End
107.375
126 10.5
41.9
-51.4
Prepared in accordance wirh; ASCE 7.16, Chaprer 30. Wind Lands - Camponents and Cladding. 7rh Ediaion (2020) Florida Building Code.