Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Code
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CHEATHAM RESIDENCE Builder Name: Street: 5908 TANGELO DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or ebsting New (From Plans) 9. Wall Types (2062.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1812.00 ft2 b. Frame - Wood, Adjacent R=13.0 250.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1536.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1536.00 ft2 6. Conditioned floor area above grade (ft2) 1536 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(227.0 sqft.) Description Area a: Sup: Attic, Ret: Attic, AH: Attic 6 140 a. U-Factor: Sgl, U=0.65 131.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.70 96.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 30.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.271 14. Hot water systems 8. Floor Types (1536.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. a. Slab -On -Grade Edge Insulation R=0.0 1536.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 58.55 Glass/Floor Area: 0.148 PASS Total Baseline Loads: 62.82 I hereby certify that the plans and specifications covered by Review of the plans andTY�E;ST,gT " this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance b_pw) TV with the Florida Energy Code.' PREP Y: D Before construction is completed DATE this building will be inspected for c�9}l ' A compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G,OD�5 OWNER/AGENT: BUILDING OFFICIfF 'r DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air.:handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project equires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). IF �® ® nz� �To ��C1B COUNTY 7/26/2019 9:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software BC)CC Page 1 of 6 . FORM R405-2017 INPUT SUMMARY CHFCKI_IST RFPC)RT PROJECT Title: CHEATHAM RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1536 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 5908 TANGELO DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Ebsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1536 17770 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 214 2354 No 0 1 1 Yes Yes Yes 2 M WIC 1 36 360 No 0 1 Yes Yes Yes 3 M WIC2 30 300 No 0 1 No Yes Yes 4 M BATH 144 1440 No 0 1 Yes Yes Yes 5 KITCHEN 134 1876 Yes 0 1 Yes Yes Yes 6 DINING 182 2548 No 0 1 Yes Yes Yes 7 PANTRY 15 150 No 0 1 No Yes Yes 8 HALLWAY 28 280 No 0 1 No Yes Yes 9 UTILITY 77 770 No 0 1 No Yes Yes 10 LIVING ROOM 154 2156 No 0 1 Yes Yes Yes 11 FOYER 79 1106 No 0 1 Yes Yes Yes 12 CLST 2 14 146 No 0 1 Yes Yes Yes 13 BEDROOM 2 173 1730 No 0 1 1 Yes Yes Yes 14 BATH 2 55 550 No 0 1 Yes Yes Yes 15 HALL 20 200 No 0 1 No Yes Yes 16 BEDROOM 3 164 1640 No 0 1 1 Yes .Yes Yes 17 CLST 3 17 170 No 0 1 Yes Yes Yes 7/26/2019 9:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 • FORM R405-2017 INPUT SUMMARY CHFCKI 1ST RFPnRT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 30 ft 0 214 ft2 -___ 1 0 0 2 Slab -On -Grade Edge Insulation M WIC 1 6 ft 0 36 ft2 ---_ 1 0 0 3 Slab -On -Grade Edge Insulation M W IC2 1 ft 0 30 ft2 __-- 1 0 0 4 Slab -On -Grade Edge Insulation M BATH 9 ft 0 144 ft2 1 0 0 5 Slab -On -Grade Edge Insulation KITCHEN 12 ft 0 134 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation DINING 14 ft 0 182 ft2 _--- 1 0 0 7 Slab -On -Grade Edge Insulation PANTRY 1 ft 0 15 ft2 1 0 0 8 Slab -On -Grade Edge Insulation HALLWAY 1 ft 0 28 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation UTILITY 1 ft 0 77 ft2 _--- 1 0 0 10SIab-On-Grade Edge Insulation LIVING ROOM 15 ft 0 154 ft2 1 0 0 11SIab-On-Grade Edge Insulation FOYER 7 ft 0 79 ft2 1 0 0 12SIab-On-Grade Edge Insulation CLST 2 8 ft 0 14 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation BEDROOM 2 26 ft 0 173 ft2 --__ 1 0 0 14SIab-On-Grade Edge Insulation BATH 2 5 ft 0 55 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation HALL 1 ft 0 20 ft2 0 0 16SIab-On-Grade Edge Insulation BEDROOM 3 25 ft 0 164 ft2 ___- 1 0 0 17SIab-On-Grade Edge Insulation CLST 3 2 ft 0 17 ft2 _--_ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1718 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1536 ft2 N N 7/26/2019 9:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 214 ft2. 0.1 Wood 2 Under Attic (Vented) MWIC1 30 Blown 36ft2 0.1 Wood 3 Under Attic (Vented) M WIC2 30 Blown 30 ft2 0.1 Wood 4 Under Attic (Vented) M BATH 30 Blown 144 ft2 0.1 Wood 5 Under Attic (Vented) KITCHEN 30 Blown 134 ft2 0.1 Wood 6 Under Attic (Vented) DINING 30 Blown 182 ft2 0.1 Wood 7 Under Attic (Vented) PANTRY 30 Blown 15 ft2 0.1 Wood 8 Under Attic (Vented) HALLWAY 30 Blown 28 ft2 0.1 Wood 9 Under Attic (Vented) UTILITY 30 Blown 77 ft2 0.1 Wood 10 Under Attic (Vented) LIVING ROOM 30 Blown 164 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 79 ft2 0.1 Wood 12 Under Attic (Vented) CLST 2 30 Blown 14 ft2 0.1 Wood 13 Under Attic (Vented) BEDROOM 2 30 Blown 173 ft2 0.1 Wood 14 Under Attic (Vented) BATH 2 30 Blown 55 ft2 0.1 Wood 15 Under Attic (Vented) HALL 30 Blown 20 ft2 0.1 Wood 16 Under Attic (Vented) BEDROOM 3 30 Blown 164 ft2 0.1 Wood 17 Under Attic (Vented) CLST 3 30 Blown 17 ft2 0.1 Wood WALLS Adjacent Space Cavity _ Width Height Sheathing Framing Solar qnru Below 1 N Exterior Concrete Block - Ext InsLKIASTER BE 4.1 16 0 11 0 176.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Ext InsLKIASTER BE 4.1 14 0 11 0 154.0 ft2 0 0.15 0.6 0 3 N Exterior Concrete Block - Ext Insul M WIC 1 4.1 6 0 10 0 60.0 ft2 0 0.15 0.6 0 4 N Exterior Concrete Block - Ext Insul M BATH 4.1 9 0 10 0 90.0 ft2 0 0.15 0.6 0 5 W Garage Frame - Wood M BATH 13 14 0 10 0 140.0 ft2 0 0.15 0.6 0 6 S Garage Frame - Wood M BATH 13 4 0 10 0 40.0 ft2 0 0.15 0.6 0 7 E Exterior Concrete Block - Ext Insul KITCHEN 4.1 12 0 14 0 168.0 ft2 0 0.15 0.6 0 8 E Exterior Concrete Block - Ext Insul DINING 4.1 14 0 14 0 196.0 ft2 0 0.15 0.6 0 9 W Garage Frame - Wood UTILITY 13 7 0 10 0 70.0 ft2 0 0.15 0.6 0 10 S Exterior Concrete Block - Ext InSa11VING ROO 4.1 4 0 14 0 56.0 ft2 0 0.15 0.6 0 11 W Exterior Concrete Block - Ext InstHIVING ROO 4.1 11 0 14 0 154.0 ft2 0 0.15 0.6 0 12 W Exterior Concrete Block - Ext Insul FOYER 4.1 7 0 14 0 98.0 ft2 0 0.15 0.6 0 . 13 N Exterior Concrete Block - Ext Insul CLST 2 4.1 6 0 10 0 60.0 ft2 0 0.15 0.6 0 14 W Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 10 0 20.0 ft2 0 0.15 0.6 0 15 S Exterior Concrete Block -. Ext Ins01EDROOM 2 4.1 12 0 10 0 120.0 ft2 0 0.15 0.6- 0 16 W Exterior Concrete Block - Ext InstBEDROOM 2 4.1 14 0 10 0 140.0 ft2 0 0.15 0.6 0 17 S Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 10 0 50.0 ft2 0 0.15 0.6 0 18 E Exterior Concrete Block - Ext InsLBEDROOM 3 4.1 13 0 10 0 130.0 ft2 0 0.15 0.6 0 19 S Exterior Concrete Block - Ext Insd8EDROOM 3 4.1 12 0 10 0 120.0 ft2 0 0.15 0.6 0 _ 20 E Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 7/26/2019 9:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software . Page 4 of 6 • FORM R405-2017 INPUT SUMMARY CHECKLIST RF_PC)RT WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 9 10 E 2 Metal N 4 Metal E 7 Metal E 8 Metal W 11 Metal W 12 Metal W 12 Metal W 16 Metal S 17 Metal E 18 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.7 0.3 N 48.0 ft2 2 ft 0 in 0.65 0.25 N 6.0 ft2 2 ft 0 in 0.65 0.25 N 12.0 ft2 2 ft 0 in 0.7 0.3 N 48.0 ft2 2 ft 0 in 0.65 0.25 N 30.0 ft2 2 ft 0 in 0.65 0.25 N 8.0 ft2 2 ft 0 in 0.65 0.25 N 24.0 ft2 2 ft 0 in 0.65 0.25 N 30.0 ft2 2 ft 0 in 0.65 0.25 N 6.0 ft2 2 ft 0 in 0.65 0.25 N 15.0 ft2 2 ft 0 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in None None None None None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 504 ft2 504 ft2 25 ft loft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000515 2073.2 113.81 214.04 .2067 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 30 kBtu/hr 900 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 7/26/2019 9:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHFrKI IST RFP[)RT DUCTS --- Supply V ---- --- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN ' RLF Heat Cool 1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ]]Jan H Heating f X] Jan Feb Feb Mar Mar A r APr May May Jun Jun rl Jul Jul ri Au AuSeP rl Se ri [ ] Oct [ ] Nov [ ]Oct [X] Nov [ ] Dec jX] Dec Ventin j[ j] Jan Feb Mar [X] Apr May Jun Jul Aug Se [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ft2 ft 0.3 M WIC 1 Default(8lbs/sq.ft. ft2 ft 0.3 M WIC2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 UTILITY Default(8 Ibs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/s .ft. ft2 ft 0.3 CLST 3 7/26/2019 9:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CHEATHAM RESIDENCE Builder Name: Street: 5908 TANGELO DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y Owner: Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the boftorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a . plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipinq and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler a ,:•: cover late _� r and walls or ceilings. Q. u" auunwi y u wNcUuui i ui luy wdos Si ia0 ue In accordance wnn the provisions of IGG-4UU. 7/26/2019 9:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 30.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1536 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.671 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.271 14. Heating system: Capacity 27.0 c) Area 7c, 227.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 5908 TANGELO DRIVE City/FL Zip: FORT PIERCE, FL 7/26/2019 9:58:42 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Pro ect SummaryJob: wri9 htsoft® Ent re House Byte: Jul 26, 2019 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information For. CHEATHAM RESIDENCE 5908 TANGELO DRIVE, FORT PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US , Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21361 Btuh Structure 19411 Btuh Ducts 4389 Btuh Ducts 3106 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25751 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 21391 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3474 Btuh Ducts 1707 Btuh Central vent (0 cfm) 0 Btuh Area Heating Cooling (none) (ft� 1536 1536 Equipment latent load 5181 Btuh Volume (ft') 17767 17767 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 26572 Btuh Equiv. AVF (cfm) 113 59 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM Model Cond RA1630AJlNA AHRI ref Coil RH1T3621HTANJA AHRI ref 8080143 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 6.5 kW Sensible cooling 21000 Btuh Heating output 22292 Btuh Latent cooling 9000 Btuh Temperature rise 20 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed +�- wrightsoft® � Right -Suite® Universal 2019 19.0.06 RSU08101 2019-Jul-26 09:47:30 Page 1 ...ocumnetsZghtsoft FNAC\CHEATHAM RESIDENCE.rup Calc = MJ8 Front Door faces: W - wrightsoft° Right-JO Worksheet Entire House Date: Jul 26, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS a(?AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 159.0 ft 11.6 ft 1535.7 ftz MASTER BEDROOM 30.0 ft 11.0 ft heat/cool 1.0 x 214.0 ft 214.0 ftz Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft� Area or perimeter (ft) Load (Bt h) Area (ftz or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 11 1. '� �G, W 13A flocs 2.glazin9, CIOM_e_ 13A-0acs 2 glazing, clr low-e 2 glazing, clr low- 2 ralazmst. dr laav 13A-4ocs 2,glazing,clr low_e__ ` 2 glazing, clr low-e 2 glazing, clr low-e .Zalazinq. dr low e 16B_30ad--0,032 22A-tphT� 0:143 -_ _,0..650 0.143 0.650 0.650 0650 ' 0:143 _.,_ Q;650 0.143 0.650 0.650 _ 0.650 1.358 n __n_ a a a e_ s. _'s_ w w w -w __- - 4.60 ;-18:20 4.00 18.20 18.20 18.20 4.00 _ 18.20. 4.00 18.20 18.20 „-18.20 0.90 38.02 2 99 14.99 219 3208 32.42 _ 3293 219 _ _ 14.99 219 32.42 32.93 3293 -_ _1 60 - 0.00 ---- 386 __.,___6 668 12 15 - 96 346 -.-.--6 412 60 8 ___1535 1535 - 380 -- _ - ---0 545 1 1 _ 4 - ' 340 _- _ 6 320 4 0 1535 159 1522 .---109 2182 218 273 _ 1747 1361 _ 109 1281 1092 146 1.375 6046 ~ -831 -�__ 90 1192 385 486 __ 3161 - 744 ,_- 90 700 1945 263 2456 0 ^ 176 .-----_ 154 0 0 48 - 176 _--------0 106 0 0 2 705 -- _ _ _ 0- 424 0 0 874 - ' 0 - 0 0 0 0 385 232 0 0 - 1581_ � 0 - 0 0 0 0 0 _ IW - b13A-4ocs F _ 0 ____—0. 0 0 0 21.4-214 214 -_ _ -0 _ 0 0 0 0 30 92342 __-1141_ 6 c) AED excursion 0 -254 Envelope loss/gain 17899 13135 3335 2286 12 a) Infiltration b) Room ventilation 3463 0 976 0 631 0 178 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 5300 0 0 1500 Subtotal (lines 6 to 13) 1 21361 194111 3966 3963 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 21% 160/6 0 0 0 21361 4389 0 0 0 19411 3106 21% 16% 0 0 5 3970 816 0 0 8 3971 635 Total room load Air required (cfm) 25751 1 001 22517 10001 1186 4786 4606 205 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -� wrigF�tsoft� 2019-Jul-26 09:47:30 .A Right -Suite® Universal 2019 19.0.08 RSU08101 Page 1 ...ocumnets\Wrightsoft HVAC\CHEATHAM RESIDENCE.rup Calc = MJ8 Front Door faces: W +�- wrightsoft° Right-JO Worksheet Jo Date: Jul 26, 2019 Entire House QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@AOL.COM 1 3 4 5 Room name wall Room he height Room dimensions Room area M WIC 1 6.0 ft heat/cool 10.0 ft 6.0 x 6.0 ft 36.0 ftz M WIC2 10.0 ft 0 ft heat/cool 5.0 x 6.0 ft 30.0 ftz Ty Construction number U-value (Btuh/ft"F) Or HTM (Btuh/ft2) Area or perimeter (ft) Load (Btuh) Area or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A4acs'- 2 glazing, cl� low_e '_ 13AAocs - 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr Igw-e 13A-flocs. -2.glaiing,LLclr low e_ 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low e 168 30ad� - 21A tp_h '_ 0.143 - ' 000 - 0.143 0.650 0.650 _ 0.650 _ 0:143 0.650 0.143 0.650 0.650 - 0.650 Q,032 -- 1.358 n` -n,_ a a a e_. s -s_. w w w w ._ - 4.00 18.20. 4.00 18.20 18.20 18.20 4.00 - 18,20 4.00 18.20 18.20 _ 18.20 -_0.90 38.02 21'9 - 14,99 219 32.08 32.42 - 32.93 -- 219 - 14.99 219 32.42 32.93 32,93 1..60 0.00 60 - 0 0 0 0 0 _-__0 0 0 0 - -_ 0 60 ' 0 0 0 _ _-_ _ 0 0 ____ _ -0 0 0 0 _-_- 0 - 240 0 0 0 __-0 0 0. 0 0 0 v 0 _ 131 - 0 - 0 0 0 0 -__ 0 0 0 0 0 0 - ---1 0 0 0 _ 0 0 0 0 0 0_ - l - 0 0 0 0 0 0 0 0 0. W 0 0 0 _ __-_- 0 0 0 0 0 0 0 0 0 0 _2 �W. � G _ F - 0 0 0 __-,--0 ___ 30 _ _�-36 36 -___36 6 __'__32 228 -�0 _ 58 0 -__ � 30 ,- __�27 .- --- -- -- ------- -�' r. - �-_-- - __ - - - ---- - ----- 6 c) AED excursion -16 -3 Envelope loss/gain 501 173 27 45 12 a) Infiltration b) Room ventilation 115 0 32 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 615 205 27 45 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 21% 16% 0 0 0 615 126 0 0 0 205 33 21% 16°/u 0 0 0 27 6 0 0 0 45 7 Total room load Air required (cfm) 742 29 238 11 32 1 52 2 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A -� wrightsoft� Right -Suite@ Universal 2019 19.0.08 RSU08101 2019-Jul-26 09:47:30Page 2 ...ocumnets\Wrightsoft WAC\CHEATHAM RESIDENCE.rup Calc = MJ8 Front Door faces: W +�- wrightsoft° Right-JO Worksheet pat : Jul 2s, 2019 Entire House QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area M BATH 9.0 ft 10.0 ft heat/cool 1.0 x 144.0 ft 144.0 ft2 KITCHEN 12.0 ft 14.0 ft heat/cool 1.0 x 134.0 ft 134.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (fl:5 or perimeter (ft) Load (Btuh) Area(ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W -- _ LSN• W, ! 13A 4gcs ; _. 2 glazmg,_Gr-low„e: _ 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 2 olazina, sir low-e-- 13Ajlocs .2.glazing; clr low_e 13Aaocs 2 glazing, clr low-e 2 glazing, clr low-e 2glazinq, clr low-e _16B_3.Oadr,, _ 0 143 _-_09650 0.143 0.650 0.650 _� _ 0.650 0.143 0.650 0. 0.650650 0.650 — 0.650 _. _ _ 0.032 1.358 n' _n- a a a _ _ e _ s use- w w w w _^ 4.00 '— 18.20 4.00 18.20 18.20 T_ 18.20 4.o0 .—:..18.2Q . 188.2020 18.20 _ 18.20 ,_,_0.80• —_36.02. _ 2:19 -_-14.W 219 32.08 3242 _ 3293 - 219 2.19 3242 3293 _ 3293 �•1.60 0.00 _6 0 0 0 --_---_0 0 0 0 0 __ 0 144 144 '_-__-0 - 109 0 0 0 . _ _ __•---0 0 0 0 0 0 _ .._._ 129 ^_ _90 0 0 0 _ �__ 0 0 0 0 0 . __ 0 -- 230 0 _ _ _ 0 168 12 0 _ - --_-- 0 0 0 0 0 __� 0 _..... "._ 134 _ 134 _G 0 156 1 0 — - - 0 0 0 0 0 0 _ _134 12 .- — _ 0 625 218 0 ----- — 0 0 0 0 0 _ _ 0 —_ -- ----12Q _ _ _ 456 _-_ 6 _-- - - -0. 341 385 0 -- -- - -0 0 0 0 0 .__ _ 0 _ . _ _ 214 0 0 0 0 _ 0 �--- - _ 0 0 0 0 �0 _ _ 144 9 _ _ -,_342 6 c) AED excursion -75 -143 Envelope loss/gain 917 429 1419 798 12 a) Infiltration ' b) Room ventilation 172 0 48 0 321 0 91 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 500 0 0 1000 Subtotal (lines 6 to 13) 1089 977 1740 1889 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 21% 16% 0 0 0 1089 224 0 0 0 977 156 21% 16% 0 0 3 1744 358 0 0 6 1894 303 Total room load Air required (cfm) 1312 51 1134 501 2102 82 2197 98 Calculations approved byACCA to meet all requirements of Manual J 8th Ed - w '!g17Tsoft- 2019-Jul-26 09:47:30 Right -Suite® Universal 2019 19.0.08 RSU08101 Page 3 ...ocumnets\Wrightsoft WAC\CHEATHAM RESIDENCE.rup Calc = MJ8 Front Door faces: W +�- wrightsoft Right-J® Worksheet Job: Entire House Date: Jul 26, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area DINING 14.0 ft 14.0 ft heat/cool 14.0 x 13.0 ft 182.0 ft' PANTRY 0 ft 10.0 ft heat/cool 5.0 x 3.0 ft 15.0 ftz Ty Construction number U-value (Btuh/ftz°F) Or HTM Area (ftj or perimeter (ft) Load (Btuh) Area (ftz or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 ! .G. W �W --G_ _C 13A flocs - -2.glazing clr_iow_e __. 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing olr lovv e 13A-4ocs 2.glazing Gr 0O ---e -- 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e .2 glazing clr_low-e 16B-Mad 0.143 -_.._0.650 0.143 0.650 0.650 _ o.A50 0:148 - 0.650 0.143 0.650 0.650 0.650 Q 032 1.358 -'.n -n_ a a a - e s «s_ w w w w _- _ 4.00 _ 18.20.. 4.00 18.20 18.20 18.20 i 4.W . . 98.20 4.00 18.20 18.20 18.20 -'._ 0.90 38.02 2.19 14.99 Z19 32.08 32.42 32 93 ~ 219 4 99 Z 19 32.42 32.93 _ 32.93 1.60. 0.00 __ _ O 196 0 0 -_ 48 - 0 -...._T.O 0 0 0 _ 0 - 182 __.0 148 0 0 2 �' �- 0 ___._-__•.0 0 0 0 0 - - 182 4 14 . .__- O 593 0 0 874 ~ 0 --_-___0 0 0 0 0 w__�-0 ---0 324 0 0 _- 1581 0 -----Q 0 0 0 0 291 � -_0 _ 0 -_ - 0 0 0 0 � -0 0 0 0 0 4-_ 15 15 _.___ 0 -- ---. 0 0 0 0 _ _ 0 ^ 0 0 0 0 -_ T 0 15 - - 0 ------ 0. 0 0 0 0 ------- 0. 0 0 0 _ 0 - 0 0 0 0 0_ -24 , 0 0 0 0 0 0 13 - 0 163 J-_ 532 _ 182 0 Zz 6 c) AED excursion -117 -2 Envelope loss/gain 2162 2078 13 22 12 a) Infiltration b) Room ventilation 375 0 106 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 2536 2184 13 22 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 21% 16% 0 0 94 2630 540 0 0 35 2219 355 21% 16% 0 0 6 19 4 0 0 9 32 5 Total room load Air required (cfm) 3176 1231 2574 1141 23 1 37 2 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. P. +� wrfigF�tsoft� Right -Suite® Universal 2019 19.0.08 RSU08101 2019-Jul-26 09:47:30Page 4 ...ocumnets\Wdghtsoft HVACICHEATHAM RESIDENCE.rup Calc = MJ8 Front Door faces: W +� wrightsoft° Right-JO Worksheet Job: Entire House Date: Jul 26, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Fposed wall Room height Room dimensions Room area HALLWAY O ft 10.0 ft heat/cool 7.0 x 4.0 ft 28.0 ftz UTILITY O ft 10.0 ft heat/cool 7.0 x 11.0 ft 77.0 ftz Ty Construction number U-value (Btuh/ft? °F) Or HTM (Btuh/ft� Area (ftj or perimeter (ft) Load (Btuh) Area (ftz or perimeter (ft) Load (Btuh) Heat Cool i Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13Aflocs <� _2.91axing clr_low ems.. 13A4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clrlow-e� 13A�ocs •- .2-glazing; clr low-e,_ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e „2 glazmg, clr low e 22A tph 0.143 , :0.650 0.143 0.650 0.650 0.650 •, 0.143 0,650 0.143 0.650 0.650 0.650 , ,1.358 n, • .,_•n_ a a a e= s: y_s._ w w w , w -� 4. 00 , 18.2Q 4.00 18.20 18.20 18.20_ w 4.00 18.20 4.00 18.20 18.20 1820 38._02 219 14.99 219 32.08 32.42 32.93 2'19 14.-99 219 32.42 32.93 32.93 -j:60 0.00 ' v�.._-0 0 0 0 0 " 0 _ 0 0 0 0 0 28 0 ._ -0 0 0 0 _ �- 0_ 0 _ 0 0 0 0 . _0, v_.._.-25.____----45. 0 ---0 _0�..._,..__.0 0 0 0 0 _.____-r._ . 0 0 0 0 0 0 _ 0 0 0- _� ._=__._o 0 0 0 _ �_ __ 0 0 .v .____0 0 -�,.�____0 0 0 0 0 _._ ,0 0, 0 '� 0 W � _-0 0 0 0 0 � 0 __. 0 0 0 0 0 ..�.,�..__.28 28___� 0 0 0 �__ ._ 0 0 _ �0 0 0 0 0 -__ _ . - 0 0 WI � :• �-y 111111111lll������ F 0 0 0 0 =_ n 77 0 0 0 0 0 0 0 0, 0 0 0 0 0 0 _ 0 _.,,-,.s,..._,.. - ,.... - 7-__. _ 6 c) AED exursion -3 -59 Envelope loss/gain 25 42 69 64 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliancestother 0 0 0 0 0 700 Subtotal (lines 6 to 13) 25 42 69 764 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 21% 16% 0 0 -25 0 0 0 0 -42 0 0 21% 16% 0 0 8 77 16 0 0 13 778 124 Total room load Air required (cfm) 0 01 0 0 i 93 1 41 902 40 Calculations approved WACCA to meet all reouirements of Manual J 8th Ed -t++- Right -Suite® Universal 2019 19.0.08 RSU08101 2019 Jul-26 09:47:30 Page 5 ...ocumnets\Wrightsoft HVAC\CHEATHAM RESIDENCE.rup Calc = MJ8 Front Door faces: W +�- wrightsoft° Right-M Worksheet Job: Entire House Date: Jul 26, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@4OL.COM 1 3 4 5 Room name Room height l he ght Room dimensions Room area LIVING ROOM 14.0 ft 15.0 ft heat/cool 11.0 x 14.0 ft 154.0 ftz FOYER 7 0 ft 14.0 ft heat/cool 1.0 x 79.0 ft 79.0 ftz I Ty Construction number U-value (Btuh/ft'-°F) Or HTM (Btuh/ft� Area (ftz or perimeter (ft) Load (Btuh) Area (ftz or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 WW 13A flocs' .2 glazing, cir Iow=e___� 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 nlazinst, clr lavv-e 13A�acs ' 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 pl8zinq_clr low_e _ 90B 30ad - _ 22A tph—1_358 0.143 _ 0.65o 0.143 0.650 0.650 _— 0,650 �0.143 0.143 0.650 0.650 __ 0 650 0.032 n —n_ a a a e_. s w w w w = 4,00 t8.20 4.00 18.20 18.20 __ 18.20 4.06 4.00 18.20 18.20 _M18.20 0 901.60 36,02 __2 16 219 3208 3242 3293 � 2 19 2.19 3242 3293 32.93 — 0_00 - --- 0 0 0 _ _ 0 �� 56 154 30 0 _._ __0 154.—_. ._--_ 154 — —__0 0 0 0 0 --------0 0 0 0 0 - 04 _____0 0 0 0 0 — 123 271 973 0 -.—_ _Q u— 246 _ 0 -- --0 0 0 0 _ 0 0 98 0 8 .—._-- 24 _ �79 79 - -- 0 0 0 0 0 0 _.,..—__a 144 0 263 _—____ 126 0 ---- 0 0 0 0 0 ' D 66 0 0 `___79 7 0 W 0 0 0 _ 0 — 0 0 IW -; C �_�_ F -- —' 56 124 2 0 __.. _ R 154 15 496 546 0 0 �— 738 570 264 0 146 ,�__71 266 _ _ _— 6 c)AED excursion 277 291 Envelope loss/gain 1975 1889 1184 1616 12 a) Infiltration b) Room ventilation 401 0 113 0 187 0 53 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 300 0 0 700 Subtotal (lines 6 to 13) 2376 2303 1371 2369 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 21% 16% 0 0 3 2380 489 0 0 6 2308 369 21% 16% 0 0 162 1533 315 0 0 51 2420 387 Total room load Air required (cfm) 2869 111 2678 119 1848 721 2807 125 Calculations approved byACCA to meet all requirements of Manual J 8th Ed - wrightsoft� Right -Suite® Universal 2019 19.0.08 RSU08101 2019-Jul-26 09:47:30Page 6 ...ocumnets\Wrightsoff WAC\CHEATHAM RESIDENCE.rup Calc = MJ8 Front Doorfaces: W +� wrightsoft° Right-M Worksheet Job: Entire House Date: Jul 26, 2019 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area CLST 2 8.0 ft 10.0 ft heat/cool 2.0 x 7.0 ft 14.0 ftz BEDROOM 2 26.0 ft 10.0 ft heat/cool 1.0 x . 173.0 ft 173.0 ftz Ty Construction number U-value (Btuh/ftL*F) Or HTM (Btu Area (ftz or perimeter (ft) Load (Btuh) Area (ftz or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 G. W 1 fk- ocs ;. ;2.9lazmg; clr low e� 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazinq, clr low-9 13A-46 s37 " 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 2,glazinq,aclr lower 166-ph _ 22A tph 0143 _ __;_Q 650 0.143 0.650 0.650 0.650 d.)43 0.143 0.650 0.650 0.650 0 58 n , • h ' a a a e. .,s w w w w 4:00 18.20 4.00 18.20 18.20 18.20 4.00 2:19 14.99.:_ Z 19 32.08 32.42 32 93 2.19 00 0 60 � ' _•_0 0 0 0 0 0 — 240 � �0 0 0 0 w 0 0 ` 131 U— n0 0 0 0 0 f - 0 - �. �._0 -_____0 ,-___,-.0 0 0 0 0_ r __L_0 __0 __ _ 0: 0 0 0 0 0 0 0 0 0 0 0 0 _0 0 0 0 0 480 0 W W F - 0 120 120 0 " 263 4.00 18.20 18.20 18.20 __0.90 38.02 Z 19 32.42 32.93 _. 32 93 _ 60 — 0.00 20 0 0 0 14 20 0 0 0 8 80 0 0 0 44 0 0 0_ 140 ' 30 0 0 110 2 0 0 440 546 0 0 241 973 0 0 . 0 304 0 _,— 173 26 989 1.358 - __ 7 ---,---- -� — - - — - _. — 7 6 c) AED excursion -171 286 Envelope loss/gain 637 180 2611 2039 12 a) Infiltration b) Room ventilation 153 0 43 0 497 0 140 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 790 223 3107 2179 14 Less extemal load Less transfer Redistribution Subtotal Duct loads 21% 33% 0 0 -790 0 0 0 0 -223 0 0 21% 16% 0 0 636 3743 769 0 0 185 2364 378 r15 Total room load Air required (cfm) 0 0 0 0 4512 175 2742 122 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A i �i- wrightsoft� Right -Suite® Universal 2019 19.0.08 RSU08101 2019-Jul-26 09:47:30Page 7 ...ocumnets\Wrightsoft HVAC\CHEATHAM RESIDENCE.rup Calc = MJ8 Front Door faces: W - - wrightsoft° Right-J® Worksheet Job: Entire House Date: Jul 26, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BATH 2 5.0 ft 10.0 It heat/cool 11.0 x 5.0 ft 55.0 ftz HALL 0 ft 10.0 ft heat/cool 4.0 x 5.0 ft 20.0 ft' Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btu Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 11 _, _ _ _._,-_ - 13A 400s; 2,g1azing; cir low e_ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e _2 glazing, Gr low a .13A-4o s 2.g1azing, Grlowce_ Y 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 20azinp rclr lower — 16B_30ad 22A-tph 0143 0 650 0.143 0.650 0.650 0.650 0 143 __ 0 650 0.143 0.650 0.650 01i50 -0 032 . n ,_n_ a a a _ e _ 's __ s_ w w w w _ �� 4:00 4.00 18.20 18.20 _ 18.20 4.00 _- 18.20 4.00 18.20 18.20 _18.20 0.96 2.19 14.99 219 3208 3242 3293 219 �_ 14.99 219 3242 3293 T- 3293 ____,_1.60 �0 _____0 0 0 0 0 �0 0 _._ 0 0 0 0 0 0 0 0 0 0 0 0 _..__ p 0 0 0 0 �0 0 0 0 Q 0 0 0 0 0 J%20 W _ W '- . I--G IW _ _C,i F 0 0 0 0 ------0 0 0 0 0 ' 0 0 0 0 0 0 0 0 0 0 __ 50 �sv 6 0 0 0 -�0 _` _ 55 ^ 44 ___ �0 - 176 0 0 0 _ 0 _ 49 96 0 0 0 0 88 0 0 0 0 0 0 — 55 0 0 0 g� 0 ._ _Y -20 __0 0 0 0 0 0 0 0 _ __ 20 0 _ _0 0 6 c) AED emursion -22 _2 Envelope loss/gain 525 253 18 30 12 a) Infiltration b) Room ventilation 96 0 27 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 (lines 6 to 13) 620 280 18 30 ]Subtotal 14 Less extemal load Less transfer Redistribution Subtotal Duct loads 21 % 16% 0 0 5 625 128 0 0 8 288 46 21 % 16% 0 0 18 0 0 0 0 30 0 0 Total room load Air required (cfm) 714 29 334 15 1 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed A Ad— Vwrightsoft- 2019-Jul-26 09:47:30 Right -Suite® Universal 2019 19.0.08 RSUD8101 Page 8 ...ocumnets\Wrightsoft HVAC\CHEATHAM RESIDENCE.rup Cale = MJ8 Front Door faces: W +� wrightsoft Right-JO Worksheet Job: Entire House Date: Jul 26, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BEDROOM 3 25.0 ft 10:0 ft heat/cool 1.0 x 164.0 ft 164.0 ft2 CLST 3 2.0 ft 10.0 ft heat/cool 2.1 x 8.0 ft 16.7 ftz Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 �_ 1VPfo s - .2 glazing, clr low_e_.._, 13A4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 plazinp, clr low-e 13A-4ocs glazing. olr low=e_-.__ 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazi'c clr low-e .- 16B-30ad ' - -_ 22AtDh _ -� 0.143 _'----_0.650 0.143 0.650 0.650 0.650 0.143 _-_0.650 0.143 0.650 0.650 0;650 _,�0.032 -,1.358 n _-•n- a a a e s -A- w w w _ w _ 4.00 --. 18.2Q 4.00 18.20 18.20 - 18.20 4.00 w _18.20 4.00 18.20 18.20 T 18.20 -.'0.90 38_02 - 2.19 1.4.99 219 32.08 3242 _ 32 93 2.19 _____14.99 2.19 3242 3293 - 3293 - 1,60 0.00 - 0 - _0 130 0 15 0 - ---A -_ 0 115 0 1 _ 0 120 ___•_ 0 0 0 0 0 V _ 164 25 ------ 0 -0 460 0 273 _ _ 0 - 480 __�-. 0 0 0 0 0 -147 -_- 951 - - - 0 - -- 0 252 0 486 0 - 263 _.__-_-0 0 0 0 __ 0 --F262 _ 0. -- - -0 - - -..0 20 0 0 _ 0 - 0 -_---�__0 0 0 0 ___ 0 _ 16 -_ __0 -0 20 0 0 _ 0 �- 0 _� 0 0 0 0 0 __ 16 __- _ � .._�-0 80 0 0 0 0 -.-_0..__-._.. 0 0 0 _ _ 0 14, _ -- - --0 -_.--_ 0. 44 0 0 -_ _ _ 0 - 0 0 0 0 0 ^ 0 _26- W _ _ W aL-G:.2 W _ C F -120 __-0.' 0 0 0 0 _ �164 _ _.. 164._ _ 6 c) AED excursion -135 -6 Envelope loss/gain 2311 1128 170 64 a) Infiltration b) Room ventilation 478 0 135 0 38 0 11 0 ]13 Internal gains: Occupants @ 230 Appliances/other 0 0 600 0 0 0 Subtotal (lines 6 to 13) 2789 1863 209 74 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 21% 16% 0 0 120 2909 598 0 0 48 1911 306 21% 16% 0 0 -209 0 0 0 0 -74 0 0 Total room load Air required (cfm) 3507 136 2216 98 1 T-1 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightsoft� Right-Suite(E) Universal 09:47:30 Universal 2019 19.0.08 RSU08101 Page 9 ...ocumnets\Wrightsoft HVAC\CHEATHAM RESIDENCE.rup Calc = MJ8 Front Door faces: W -+ wrightsoft® Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM I For. CHEATHAM RESIDENCE 5908 TANGELO DRIVE, FORT PIERCE, FL Job: Date: Jul 26, 2019 By: Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1000 cfm 1000 cfm Total effective length (TEL) 202 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 754 29 15 1.000 5.0 Ox 0 VIFx 43.9 115.0 st2 BEDROOM 2 h 4512 175 122 1.000 7.0 Ox 0 VIFx 47.0 115.0 st2 BEDROOM 3 h 3507 136 98 1.000 7.0 Ox0 VIFx 48.5 115.0 st2 DINING h 3170 123 114 1.000 7.0 Ox0 VIFx 45.9 155.0 st4 FOYER c 2807 72 125 1.000 7.0 Ox 0 VIFx 46.4 115.0 st2 KITCHEN c 2197 82 98 1.000 7.0 Ox 0 VIFx 46.9 155.0 st4 LIVING ROOM c 2678 111 119 1.000 7.0 Ox 0 VIFx 26.3 115.0 st1 M BATH h 1312 51 50 1.000 6.0 Ox 0 VIFx 21.2 115.0 st1 M WIC 1 h 742 29 11 1.000 4.0 Ox 0 VIFx 23.6 115.0 st1 M WIC2 c 52 1 2 1.000 4.0 Ox 0 VIFx 19.1 115.0 st1 MASTER BEDROOM c 2303 93 102 1.000 7.0 Ox 0 VIFx 32.8 135.0 st3 MASTER BEDROOM -A c 2303 93 102 1.000 7.0 Ox 0 VIFx 28.3 135.0 st3 PANTRY c 37 1 2 1.000 4.0 Ox 0 VIFx 28.3 135.0 st3 UTILITY c 902 4 40 1.000 6.0 Ox0 VIFx 31.9 135.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 412 360 1.000 756 10.0 0 x 0 VinlFlx st4 Peak AVF 205 212 1.000 480 9.0 0 x 0 VinlFlx st3 st3 Peak AVF 395 458 1.000 694 11.0 0 x 0 VinlFlx st1 st1 Peak AVF 588 640 1.000 815 12.0 0 x 0 VinlFlx 1 {�" wrightsoft® 2019-Jul-26 09:47:32 �A •���^�m^*nr^��^-•��*�. Right-SuiteC� Universal 2019 19.0.08 RSU08101 Page 1 ...ocumnets\Wdghtsoft HVAC\CHEATHAM RESIDENCE.rup Calc = MJ8 Front Door faces: W Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1000 1000 0 0 0 0 Ox 0 VIFx wrightsoft°' 2019-Jul-26 09:47:32 /� •u"�.�s...,•...,...��^^.y^� Right -Suite® Universal 2019 19.0.08 RSUD8101 Page 2 ocumnets\Wdghtsoft WAC\CHEATHAM RESIDENCE.rup Calc = MJ8 Front Door faces: W