HomeMy WebLinkAboutDensity of Soil in PlaceA. M. ENGINEERING ,ND TESTING, INC. 3504 INDUSTRIAL 33R11 STREET FT. PIERCE, FLORIDA 34946 LOCALOFFICE: (772) 461-7508 FAX: (772) 461-8880 DENSITY OF SOIL_IN PL ,E, Client: Ditch Diggers "`"-�-p. �/� ����eport Date: 7/21/2004 Contractor: Client , fUL27T'chntcian: BLSite: Tradition South Tower2Qo/iPage1 of2 Footings 1u�re I rmit No: 23090598 /I/, ��'° .� PUblin Ins Test No. Date Tested Location Eleva- tion (ft) Field Test Results-�>;' 'Proctor Max Dry Density (c Com action Pass/ Fail HCP HZO %) Dry Density c Probe Depth (in) In Place % Min Req'd %) 2935 7/16/04 32 x 32 Footing, North Side 0 - 1 70 1 6.6 110.9 1 12 112.1 98.9 95 P 2936 1 - 2 85 112.1 95+ 95 P 2937 2-3 70 112.1 95+ 95 P 2938 32 x 32 Footing, East Side 0-1 75 7.2 111.4 12 112.1 99.4 95 P 2939 it1-2 80 112.1 95+ 95 P 2940 if2-3 80 112.1 95+ 95 P 2941 32 x 32 Footing, South Side 0-1 90 9.4 110.2 12 112.1 98.3 95 P 2942 111 - 2 70 112.1 95+ 95 P 2943 2-3 85 112.1 95+ 95 P 2944 32 x 32 Footing, West Side 0-1 70 8.1 109.9 12 112.1 98.0 95 P 2945 if1-2 90 112.1 95+ 95 P 2946 2-3 80 112.1 95+ 95 P 2947 18x18 Stem Wall Footing, N - Side 0-1 95 8.9 110.6 12 112.1 98.7 95 P 2948 if1 - 2 90 112.1 95+ 95 P 2949 it2-3 80 112.1 95+ 95 P 2950 18x18 Stem Wall Footing, E - Side 0-1 95 6.2 110.1 12 112.1 98.2 95 P 2951 1 - 2 80 112.1 95+ 95 P 2952 2-3 90 112.1 95+ 95 Remarks: • All elevations are below bottom of footing. The field density tests were performed in general compliance with ASTM D 2922, Density of Soil in Place by Nuclear Methods. The Hand Cone Penetrometer (HCP) test, in conjunction with information about the soil type, is empirically correlated to the relative density of the subsurface soils. The laboratory Proctor maximum dry density was determined in accordance with ASTM D 1557. f A. M. ENGINEERING AND TES`J <<�°�G, INC. DENSITY OF SOIL IN PLACE - continued Client: Ditch Diggers Contractor: Client Site: Tradition South Tower Footings Report Date: 7/21/04 Technician: BL Page 2 of 2 Permit No: 23090598 Test No. Date Tested Location Eleva- tion (ft) Field Test Results Proctor Max Dry Density (ef) Com action Pass/ Fail HCP HZO (%) Dry Density (ef) Probe Depth (in) In Place (%) Min Req'd %) 2953 7/16/04 18x18 Stem Wall Footing, S - Side 0-1 95 1 3.1 111.3 1 12 112.1 99.3 95 P 2954 if 1-2 90 112.1 95+ 95 P 2955 if 2-3 80 112.1 95+ 95 P 2956 18x18 Stem Wall Footing,W - Side 0-1 90 8.3 109.9 12 112.1 98.0 95 P 2957 of 1-2 80 112.1 95+ 95 P 2958 2-3 75 112.1 95+ 95 P Remarks: • All elevations are below bottom of footing. • The field density tests were performed in general compliance with ASTM D 2922, Density of Soil in Place by Nuclear Methods. • The Hand Cone Penetrometer (HCP) test, in conjunction with information about the soil type, is empirically correlated to the relative density of the subsurface soils. The laboratory Proctor maximum dry density was determined in accordance with ASTM D 1557. Reviewed by: Distribution: A. M. ENGINEERING AND TESTING, INC. Client - 3 Rebecca Grant Ascoli, P. E. Florida Registration No. 51863 2935 - 2952.s1s