ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEETgpO:.�vWO�-Odx
REVIEWED FOR
Florida Building Code 7th Edition (2020) CODE COMPLIANCE
Based on Section 1525 of the Florida Building Code-Buildin ® g�® y
INSTRUCTION PAGE ��° �' �CIE � ees
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
Roof System the Permit Application See List Below
Form
Low Slope Application A,B,C 1,2,3,4,5,6,7
Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7
Asphaltic Shingles A,B,D 1,2,4,5,6,7
Concrete or Clay Tile A,B,D, E 1,2,3,4,5,6,7
Metal Roofs A,B,D 1,2,3,4,5,6,7-
Wood Shingles and A,B,D 1,2,4,5,6,7
Shakes
Other As Applicable 1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form Roof1nfoFeb21 Rev Feb 18,2021
ST LUCIE WORKS
oSectionneral Information)
Master Permit No. Process No.
Contractors Name: e►`�w� r` w(icense# CC C l 3 .3 /3a b
Job Address . 7� b".�9� . Sa�• c�dL &T_ &/, 1`�.�/_ d !��J
ROOF CATEGORY
ow Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
❑Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance E I'Reroofing ❑Recovering
-ROOF SYSTEM INFORMATION ,q
Low Slope Roof Area(SF) !/0Z Steep Sloped Roof Area(SF) /ti Total(SF) /6y 0
Section B(Roof P n)
Sketch Roof Plan: Illustrate all levels and ctions, roof dra' scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identi y dimensions of elevated pressure zones and location of parapets.
(61
7
r
ST. LUCIE WORKS
Section C ( w Slope Roof)
Surfacing:
Fill ins e ' c?roof assembly components and identifyFastener Spacing for Anchor/Base Sheet Attachment:
P Y P
a cturer; Zone 1':—" oc @ Lap,#Rows—®"oc
(If a component is not use idef tify a "NA") Zone 1:—" oc @ Lap,
/ �� S #Ro s—®—
System ManuGO
facturer: Zone 2:—"oc @ Lap,#R ws ®"0
�j //_��_ Qa �f Zone 3:_.._."oc @ ap,# ow ®"o0
Product Approval No.: L. �(/ "
Number of Fasten r er I ula io Board:
4 Design Wind Pressures,From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3:
r C� _(� p
Zone 171 Zone 1: -!q Zone 7-0-0-Ine 1-917. Illustrate Components Noted and Details as Applicable:
Max. Design Pressure�frQm the specific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: ((�� Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing,Coping,Etc..
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: Flashing,Component Material,Material'Thickness,Fastener
4f
Type,Fastener Spading or Submit Manufacturers Details that
Gauge Thickness:
Comply with RAS 111 and Chapter 16..
Slope: c
Anchor/Base Sheet&No.df Ply(s): -ram � /
aAnchor/Base Sheet�Fast �r/Bonding Material: FT.
Insulation Base Layer: A
Base Insultation Size and Thickness: R- /A n 7 Parapet
Base Insulation Fastener/Bonding Material: b Y ,~ P� Height
.� 1�
Top Insulation Layer: D �5 4C
Top Insulation Size d T ick essVaterial:
J FT.
f I
Top Insulation Fas ener/Bo ing q
AA � Mean
Base Sheet(s)&No.of Ply(s): .5"�V— s-ry / Roof
Base Sheet Fastener/ ending Material: Q�s� Height
Ply Sheet(s)'&No.of Ply(s):
Ply Sheet Fastener/B nding Material:
H-Top Ply: $-A /� � tylo /, i
Top Ply Fastener/Bonding Material:
�A
ST. LUCIE WORK
Section D (Steep Slope Roof System)
Roof System Manufacturer:
Notice of Acceptance Number:
Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations):
Zone 1: Zone 2e: Zone 2n:_Zone 2r: Zone 3e: Zone 3r:
Deck Type:
Type Underlayment
Roof Slope:
42 Insulation:
Fire Barrier:
Ridge Ventilation? Fastener Type&Spacing:
Adhesive Type:
Type Cap Sheet:
Mean Roof Height: Roof Covering:
Type&Size Drip
Edge:
ST. LUCIE WORKS
Section E(Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf.If the Mf values
are greater than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _x?L = _�_ Mg: =Md Product Approval Mi
(Zone 2e: xIL _ -Mg: =M Product Approval Mf
(Zone 2n: • x A = --Mg: =M,2,, Product Approval Mf-
(Zone 2r: _x)L _ -Mg: =M,g Product Approval Mf
(Zone3e: x; _ _�-Mg: =Mrae Product Approval Mf,
(Zone 3r: ' x)L _ ___a-Mg: =Mrs Product Approval Mf
Method 2"Simplified Tile Calculations Per Table Below"
Required Moment of Resistance(Mr)From Table Below Product Approval Mf
Mr required Moment Resistance*
Mean Roof Height Roof Slope 15' 20' 25' 30' 40'
2:12 34.4 36.5 38.2 39.7 42.2
3:12 32.2 34.4 36.0 37.4 39.8
4:12 30.4 32.2 33.8 35.1 37.3
5:12 28.4 30.1 31. 32.8 34.9
6:12 26.4 28.0 29 30.5 32.4
7:12 1 24.4 1 25.9 1 27.1 28.2 30.0
*Must be used in conjunction with a list of moment based tile syste s
• For Uplift based tile systems use Method 3.Compare the values fo F'with values for Fr If the F'values are greater than or
equal to the Fr values,for each area of the roof,then the tile attac ent m is acceptable.
Method 3"Upl ft Based Tile Cal ulation Per RAS 12T
(Zone 1: x L =x W:= )-W: c r = 1 Product Approval F'
(Zone 2e: x L =x W:= )-W: os r - r2e Product Approval F'
(Zone 2n: x L =x W:= )-W: cos r Fr2n Product Approval F'
(Zone 2r: x L =x W:= )-W: cos r r2r Product Approval F'
(Zone 3e: x L =x W:= )-W: cos r -Fr3e Product Approval F'
(Zone 3r: x L =x W:= )-W: cos r =Fr3r Product App,7,oval F'
Where to Obtain Information
Description Symbol Where to find
Design Pressure Zones 1,2e,2n,2r,3e,3r From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height H Job Site
Roof Slope 6 Job Site
Aerodynamic Multiplier a Product Approval
Restoring Moment due to Gravity Mg Product Approval
Attachment Resistance Mf Product Approval
Required Moment Resistance Mg Calculated
Minimum Attachment Resistance F' Product Approval
Required Uplift Resistance Fr Calculated
Average Tile Weight W Product Approval
Tile Dimensions L=length W=width Product Approval
All calculations must be submitted to the building official at the time of permit application.