Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETL-LLLL PE S u , U: i ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System i Required Sections of the Permit Application Form Attachments Required See List Below 1 Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 E etal Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable _�- - 1,2,3,4,5,6,7 - ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5, Municipal Permit Application € 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RoofinfoFeh21 Rev Feb 18, 2021 Section A (General Information) Master Permit No. ✓ Process No. Contractors Name: I�vICP � �A/ License # ��G I S&P 3�6 Job Address S�Da°/r►'Le �r -rare- �e>s-�cj �G �yg�a- ROOF CATEGORY ff Low Slope ❑/Mechanically Fastened Tile ElMortar/Adhesive Set Tiles 0 ❑Asphaltic Shingles Metal Panel/Shingles ❑wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE_ ❑ New roof ❑ Repair ❑ Maintenance ❑ Reroofing ❑Recovering . ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped.r�. Roof Area (SF) � b Total (SF) 9q0 D Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: f20((*14(55 t�SA Product Approval No.: 1651, 1 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1':-3.Z•Zone 1: -6"/ Zone 2: -re/Zone 3: -115 Max. Design Pressure, from the specific product approval system: - 1 / Z • 5 Deck: Type: �l�Gt/QQU Gauge Thickness: AAlif Slope: Anchor/Base Sheet & No. df Ply(s): f e4t r1a,5 rD,b� � J Anchor/Base Sheet Fastener/Bonding Material: 'gin Cuffs i/`! R,na�ltgsi n.t;/5 Insulation Base Layer: )VIA Base insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Top Insulation FAsteher/koriding Material: Base Sheet(s) & Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): l D/N 5Ay Ply Sheet Fastener/Bonding Material: SFl V - 5A Top Ply: 'I Aw SAP Top Ply Fastener/Bonding Material: Surfacing: 1' /A Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1': " oc @ Lap, # Rows H @ y "oc Zone 1: � " oc @ Lap, # Rows '4 @ y -oc Zone 2: 'N " oc @ Lap, # Rows y ® N "oc Zone 3:T" oc @ Lap, # Rows —!i- "oc Number of Fasteners Per Insulation Board: Zone 1':—Zone 1: Zone 2:—Zone 3:— Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, f�t�ight✓HeggE of Buse -61a5h+Rg, Component /Iaterial, Material' Thickness, Faste er Type, Fastener Spacing or Submit Manufac urers Details that Comply with RAS 111 and Chapter 16.. FT. Parapet Height � ru •, is .. FT. E/Qyfobnsc 4.0 NN Av a• v NM 5Rp 3.5 NM Mean Roof Height Section D (Steep Slope Roof System) �/� t Roof System Manufacturer: i/ �%%��%�l I -� �/® C/latsi ` 7 Notice of Acceptance Number: aggj q . Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: "-71 Zone 2e: - 41 Zone 2n: Zone 2r:'qLZone 3e:-� UlZone 3r: — It( - Deck Type: Wood 1l / i3 11 Type Undertayment: ed CA-. Roof Slope: 12 Insulation: 1A Fire Barrier: l A Ridge Ventilation? Fastener Type & Spacing: I '/I Ain,007A�i L5 Adhesive Type: A6 A Type Cap Sheet: Mean Roof Heig ht: ) Roof Covering: Type & Size Drip Edge: _ ' ES LUC�: Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mf. If the Mf values are greater than or equal to the M,values, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone1: _x2._=- Mg: -=M,,- Product ApprovalM, (Zone2e: _x2,-= -Mg: _=M, Product Approval Mr (Zone2n: _xh-= -)-Mg:_=M,2,- Product Approval Mf- (Zone 2r: _.x2,.= _)-Mg: -=M2r_ Product Approval Mf (Zone3e:--x2,.-= _)-Mg:-=Mr, - Product Approval Mf- (Zone 3r: _XX-= -)-Mg:-=Mrar- Product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance NO From Table Bellow Product Approval Mf M, required Mom sistance* Mean Roof Height Roof Slope 15' Z 2 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 .4 30.5 32.4 7:12 24.4 .9 27. 28.2 30.0 *Must be used in conjunction with a list of moment b ed the systems • For Uplift based tile systems use Method 3. Compare t values for F' with the values for F, If the F' values are greater than or equal to the Fr values, for each area of the roof, then the ti attachment method is acceptable. Meth\"Upliftsed T� Calculations Per RAS 12T (Zone 1: x L=x W:=) -r Fn Product Approval F' (Zone 2e: x L =x W:= ) s r = e Product Approval F' (Zone 2n: x L =x W:= ) s r =Fa"Product Approval F' (Zone 2r: x L= x W:=) s r=Fr2r Product Approval F' (Zone 3e: x L =x W:=) s r=Eras Product Approval F' (Zone 3r: x L =x W:= ) s r =Fran Product Approval F' Where to CAn Information Description Sym Where to find j Design Pressure Zo es 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height j H Job Site Roof Slope L 6 Job Site Aerodynamic Multiplier Product Approval Restoring Moment due to Gravity MX, Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight Tile Dimensions W L= length W = width Product Approval -{ Product Approval All calculations must be submitted to the building official at the time of permit application. -Jj