HomeMy WebLinkAboutPRODUCT APPROVAL8/17/2021
Florida Building Code Online
Business & ProfessionalRegulation rAmra�
BCIS Home Lop In I User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us . BCIS Site Map Links Search
b
1d
p■ product Approval
r USER: Public User
Product Approval Menu > Product or Agolication,, earth > AQpncation List > Application Detail
FL # FL38576-RI
Application Type Revision
Code Version �Q20
Application Status Approved
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772)872-8030
Juan@dynamicmeta1, net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory 46rRooflng Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Lucas A. Turner, P.E., MBA
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL38576 R1 C01 DMRV p�f
Standard
TAS 100A
Year
1995
Product Approval Method
Method 1 Option D
https:llfloridabuilding.org/pr/pr app_dti-aspx?param=wGEVXQWtDqurhYH°/a2fNuQVrH7xpTGbQlsnRIHRyDs3yAXKxR5eytbrsg%3d%3d 112
8/17/2021
Florida Building Code Online
KIA
Date Submitted 06/15/2021
Date Validated 06/15/2021
Date Pending FBC Approval 06/18/2021
Date Approved 08/10/2021
Summary of Products
FL At
Model, Number or Name
Description
38576.1
Dynamic Ridge Vent
0.032" Alum or 26 Ga Steel Vented Ridge Cap (Low Slope).
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL38576 Rl II Rid el Dwa2.odf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Installation Drawings and Eval Report for
FL38576 R1 AE Ridcel Eval2.odf
Limits of Use.
Created by Independent Third Party: Yes
38576.2
Dynamic Ridge Vent
0.032" Alum or 26 Ga Steel Vented Ridge Cap (High Slope)
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL38576 R1 II Ridoe2 Dwa2 p(i-f
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Installation Drawings and Eval Report for
FL38576 Rl AE Ridoe2 Eval2.odf
Limits of Use.
Created by Independent Third Party: Yes
Bach Neat
Contact Us :: 2601 Blair Stone Road. Tallahassee Fl- 32399 Phone: 850A87-1824
The State of Florida is an AA/EEO employer. copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Flonda law, email addresses are public records. If you do not want your e-mall address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.467.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The smalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish ts supply a personal address, please
Provide me Department with an email address which can be made available to the public. To determine 8 you are a licensee under Chapter 455, RS., please dick here .
product Approval Accepts:
®®5 ■
Credit Card
Safe
https://floridabuilding.orglpr/pr app_dtl.aspx7param=wGEVXQwtDqurhYH%2fNuQVrH7xpTGbQlsnRIHRyDs3yAXKxRSeytbrsg%3d%3d 2/2
4. r WOLTERS ENGINEERING
ENGINEERING, DRAFTING, CONSULTING
15211 971^ Road N
West Palm Beach, FL 33412
PhIFx: (561) 225.1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DYNAMIC VENTED RIDGE CAP (HIGH SLOPE)
(FLPA# 38576.2)
MANUFACTURER: DYNAMIC METALS, LLC
i 3201 SE DOMINICA TERRACE
STUART, FL 34997
To all concerned,
The Dynamic Vented Ridge Cap (High Slope) is manufactured by Dynamic Metals LLC from 0.032"
Fluropon coated aluminum (25 ksi min) or 26 Ga. galvalume or Fluropon coated steel (50 ksi min). The vented
ridge cap meets the requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code.
The panels have been tested per TAS 100(A) by Intertek B&C, with results shown in test report M1246.01-450-18.
It has also been tested per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports
VLS-004-02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "DMRVHS-HZ" dated 4119/21, signed and sealed by Scott Wolters, PE.
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE.
3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary
R Priest, PE.
4. Supplemental Calculations to support DMRVHS-HZ, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This system is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Ridge Cap Width: 12112" (Length is unlimited)
Maximum Ridge Cap Height: Varies (Based on roof slope)
Min. Slope: 3712"
5PECIA.IZIN6 IN IMPACT P�515TAW CWTAINWA15, 5TOUVONT5, & WIN19OW5
Minimum Substrate: %2 (15/32' min) 5-ply CDX Plywood or'/4" solid wood planks (S.G. = .42
min) nailed to 2x rafters spaced 24" max. on center with 8d ring -shank
nails spaced 6" on center.
Note: The'/4" wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architect/Engineer
or
Structural panels with 16 Ga. (min) Steel Purlins.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
4. All panel system perimeters, penetrations, and transitions to be
Flashed and sealed per the requirements of RAS 133.
5. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
If you have any questions or need more information concerning this approval please contact me.
Thank you,
01�1"""!"!10,
VVOL.T��'�.
.� 011.
6-
No 62354 %
Scott Wolters
`
FL PE# 62354
: v
1UN14 1011
STATE OF
a
*'� p
. 0R1?. C>�'. `�..
5MCIALIZING IN IMPACT M515TANT CLVAINWA15, 5TOI: PONT5, & WIN12OW5
lau _._ _, m(ZUJ _
�j «_ � m � ;
gd 3n > &»Nm
Om
,
E! |
a0.
®
/X8
Z
/
lo�
_
■ \
;
§
/
� /
!
2
K
x
, w
k�ui
o } 0
2co mb§
�02@
uj
«0
z � §
L—■IL
>20Q
b aq§
«�QLU
z CO) LU
�R>
04090