Loading...
HomeMy WebLinkAboutenergy calcsFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-EMERALD Builder Name: KHOVNANAIN HOMES Street: 5128 ARM INA PL. Permit Office: City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: EMERALD MODEL LOT 3 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 } 1. New construction or existing New (From Plans) 10. Wall Type$2508.8 sqft.) Insulation Area 2. Single family or multiple family Detached a. Frame -Wood, Exterior R=11.0 1180.70 ftZ 3. Number of units, if multiple family 1 b. Concrete Block - Int Insul, Exterior R=4.1 973.39 ft2 c. Frame - Wood, Adjacent R=11.0 354.67 ft2 4. Number of Bedrooms 5 d. NIA R_ ft2 5. Is this a worst case? No 11. Ceiling Types (1354.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1354.00 ftZ 6. Conditioned floor area above grade (ftZ) 2321 b. NIA R= ft2 Conditioned floor area below grade (ftZ) 0 c. NIA R= ft2 7. Windows(194.0 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.30 152.00 ft2 a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT 6 250 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=0.55 42.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.34 a. Central Unit 46.5 SEER:16.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.165 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.293 a. Electric Strip Heat 32.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15, Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1354.1 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 968.10 ft2 b. Conservation features b. Raised Floor R=11.0 386.00 ft2 None c. NIA R= ft2 16. Credits Pstat Glass/Floor Area: 0.084 Total Proposed Modified Loads: 70.47 PASS Total Baseline Loads: 71.88 /`1 I hereby certify that the plans and specifications covered by Review of the plans and i S74 this calculation are in compliance with th lorida Energy specifications covered by this !� Cade. i F� calculation indicates compliance �j`�' i,,, �'•1 = = �.� �. with the Florida Energy Code. a:Fr,��-E: - -t * `;.• `„p PREPARED BY. � ;`- Before construction is completed DATE: f this building will be inspected for , compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes.<e, with the Florida Energy Code. (?0 OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/16/2021 8:41 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KHOV-EMERALD Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2321 Lot # Owner Name: EMERALD MODEL LOT 3 @ Total Stories: 2 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: KHOVNANAIN HOMES Rotate Angle: 0 Street: 6128 ARMINA PL. Permit Office: Cross Ventilation, No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2,5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH—MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2321 19341.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 EXTRA SUITE 144 1267,2 No 2 5 1 No Yes Yes 2 EX SUITE BATH 60 528 No 0 1 No Yes Yes 3 FOYER 133 1173 No 0 1 No Yes Yes 4 GIRT DIN KITCHEN 630 5544 No 1 1 No Yes Yes 5 BED 4 174 1392 No 1 1 No Yes Yes 6 BED 3 167 1334 No 1 1 No Yes Yes 7 BED 2 162 1296 No 1 1 No Yes Yes 8 HALL LOFT 350 2800 No 0 1 No Yes Yes 9 LAUNDRY 48 384 No 0 1 No Yes Yes 10 MASTER SUITE 224 1792 No 2 1 No Yes Yes 11 MAST WIC 60 476 No 0 1 No Yes Yes 12 MASTER BATH 104 832 No 0 1 No Yes Yes 13 HALL BATH 65 518 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio EXTRA SUITE 24 ft 0 144.8 W ---- 0 1 0 2 Slab -On -Grade Edge Insulatio EX SUITE BATH 6 ft 0 60 ftz ---- 0 1 0 3 Slab -On -Grade Edge Insulatio FOYER 20.5 ft 0 133.3 ft! ---- 1 0 0 4 Slab -On -Grade Edge Insulatio GRT DIN KITCHE 89 ft 0 630 fie ---_ 0.5 0.5 0 6/16/2021 8:41 AM EnergyGauge® USA T0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Raised Floor BED 4 ---_ ---_ 174 ft2 11 0 0 1 6 Raised Floor BED 3 -_-- --_- 167 ft2 11 0 0 1 7 Raised Floor HALL LOFT -_-_ ---- 45 ft2 11 0 0 1 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1466 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 22.62 ATTIC v # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Vented 150 1353 ftz N CEILING # Ceiling Type Space R-Value Ins Type Area 1 Under Attic (Vented) BED 4 30 Blown 174 ft2 2 Under Attic (Vented) BED 3 30 Blown 167 ft2 3 Under Attic (Vented) BED 2 30 Blown 162 ft2 4 Under Attic (Vented) HALL LOFT 30 Blown 350 ft2 5 Under Attic (Vented) LAUNDRY 30 Blown 48 ft2 6 Under Attic (Vented) MASTER SUITE 30 Blown 224 ft2 7 Under Attic (Vented) MAST WIC 30 Blown 60 ft2 8 Under Attic (Vented) MASTER BATH 30 Blown 104 ft2 9 Under Attic (Vented) HALL BATH 30 Blown 65 ft2 WALLS Adjacent Wall TypeSpace Cavity Width Height 1 E Exterior Concrete Block - Int InsEIXTRA SUIT 4.1 10 8 9 4 99.6 ft2 2 S Exterior Concrete Block - Int Ins&IXTRA SUIT 4A 11 8 10 0 116.7 ft2 3 S Exterior Concrete Block - Int InsEK SUITE BA 4.1 5 5 10 0 64.2 ft2 4 E Exterior Concrete Block - Int Insul FOYER 4.1 6 9 9 4 63.0 ft2 5 N Exterior Concrete Block - Int InsGRT DIN KIT 4.1 17 5 9 4 162.6 ft2 6 S Exterior Concrete Block - Int Ins12RT DIN KIT 4.1 16 2 10 0 161.7 ft2 7 W Exterior Concrete Block - Int Ins@RT DIN KIT 4.1 33 10 9 4 315.8 ft2 8 N Exterior Frame - Wood BED 4 11 13 8 8 10 120.7 ft2 9 E Exterior Frame - Wood BED 4 11 10 11 8 10 96.4 ft2 10 E Exterior Frame - Wood BED 3 11 10 11 $ 10 96.4 ft2 11 E Exterior Frame - Wood BED 2 11 10 11 8 10 96.4 ft2 12 S Exterior Frame - Wood BED 2 11 12 3 8 10 108.2 ft2 13 N Exterior Frame - Wood HALL LOFT 11 7 3 8 10 64.0 ft2 I RCC N Framing Frac Truss Type 0.1 Wood ❑.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood 0.1 Wood Sheathing Framing Solar Below 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 0 0 0.5 0 6/16/2021 8:41 AM EnergyGauge(D USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below `14 S Exterior Frame - Wood HALL LOFT 11 12 9 8 10 112.6 ft2 0 0 0.5 0 15 N Exterior Frame - Woad MASTER SUi 11 13 2 8 10 116.3 ft2 0 0 0.5 0 16 W Exterior Frame - Wood MASTER SUI 11 14 7 8 10 128.8 ft2 fl 0 0.5 0 17 W Exterior Frame - Wood MASTER BA 11 11 10 8 10 104.5 ft2 0 0 0.5 0 18 S Exterior Frame - Wood HALL BATH 11 10 0 8 10 88.3 ft2 0 0 0.5 0 19 W Exterior Frame - Wood HALL BATH 11 5 5 8 10 47.8 ft2 0 0 0.5 0 _20 W Garage Frame - Wood GIRT DIN KIT 11 38 0 9 4 354.7 ftz 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated FOYER None .39 3 4 6 8 22.2 ft2 2 E Wood FOYER None .39 3 4 6 8 22.2 ft2 WINDOWS Orientation shown is the entered, Proposed orientation, / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screeni 1 E 1 Metal Double (Tinted) Yes 0.3 0.28 N 15,0 ft2 1 ft 0 in 12 ft 0 in None None 2 W 7 Metal Double (Tinted) Yes 0.3 0.28 N 32.0 ft2 1 ft 0 in 12 ft 0 in None None 3 W 7 Metal Double (Tinted) Yes 0.55 0.34 N 42.0 ft2 11 ft 0 in 1 ft 0 in None None 4 E 9 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 5 E 10 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 6 E 11 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 7 N 13 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 8 S 14 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 9 W 16 Metal Double (Tinted) Yes 0.3 0.28 N 30.0 ft' 1 ft 0 in 1 it 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 386 ft2 386 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .00037 2255.9 123.76 232.35 .1694 7 6/16/2021 &41 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 32 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 46.5 kBtulhr cfm 0.74 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft2 HALL LOFT 1 ft2 Default Leakage HALL LOFT (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling HeatingX Jan Jan Feb Feb Mar Mar A r Apr Ma May X Jun Jun X Jul Jul AujXj rl Au Sep Sep Oct OctX �Xj Nov NovX Dec Dec Venting Jan Feb X Mar [X A r Ma Jun Jul Aug Se Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 80 80 80 8o 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (VVEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Def2ult(8 lbs/sq.ft. 0 ft$ Oft 0.3 BED 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL BATH Default(8 Ibslsq.ft. ft2 ft 0.3 FOYER Default(8 Ibslsq.ft. ft2 ft 0.3 BED 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BED 2 Default(8 Ibs/sq,ft. ft2 ft 0.3 GRT DIN KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER SUITE 6/16/2021 8:41 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Default(8 Ibs/sq.ft, Defaultf8 Ibs/sa ft Area Thickness f 2 ff Furniture Fraction Space 0.3 MAST VViC 0.3 M BATH 6/16/2021 8:41 AM EnergyCauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows'* Description a. U-Factor; Dbl, U=0.30 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.34 c. U-Factor: NIA SHGC: d. 1-1-Factor: NIA SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): NIA SHGC(AVG): NIA 9. Floor Types a. Slab -On -Grade Edge Insulation b. Raised Floor c. NIA 5128 ARMINA PL., FORT PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Insu€ation Area Detached a. Frame -Wood, Exterior R=11.0 1180.70 ft2 b. Concrete Block - Int Insul, Exterior R=4.1 973.39 ft2 1 C. Frame - Wood, Adjacent R=11.0 354.67 ft2 5 d. NIA R= ft2 No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1354.00 ft2 2321 b. NIA R= ft2 Area c. NIA R= ft2 152.00 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT 6 250 42.00 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 46.5 SEER:16.00 ftz 3.165 ft. 0.293 Area ft2 Insulation Area R=0.0 968.10 ft2 R=11.0 386.00 ft2 R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: kBtulhr Efficiency 32.0 COP:1.00 Cap: 50 gallons EF: 0.95 Pstat ,y01JJisSJ,4 0 COL wB. *Note: This is not a Building Energy Rating, If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/16/2021 8:41 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1