HomeMy WebLinkAboutenergy calcsFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-EMERALD
Builder Name: KHOVNANAIN HOMES
Street: 5128 ARM INA PL.
Permit Office:
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: EMERALD MODEL LOT 3 @ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 }
1. New construction or existing New (From Plans)
10. Wall Type$2508.8 sqft.) Insulation Area
2. Single family or multiple family Detached
a. Frame -Wood, Exterior R=11.0 1180.70 ftZ
3. Number of units, if multiple family 1
b. Concrete Block - Int Insul, Exterior R=4.1 973.39 ft2
c. Frame - Wood, Adjacent R=11.0 354.67 ft2
4. Number of Bedrooms 5
d. NIA R_ ft2
5. Is this a worst case? No
11. Ceiling Types (1354.0 sqft.) Insulation Area
a. Under Attic (Vented) R=30.0 1354.00 ftZ
6. Conditioned floor area above grade (ftZ) 2321
b. NIA R= ft2
Conditioned floor area below grade (ftZ) 0
c. NIA R= ft2
7. Windows(194.0 sqft.) Description Area
12. Ducts R ft2
a. U-Factor: Dbl, U=0.30 152.00 ft2
a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT 6 250
SHGC: SHGC=0.28
b. U-Factor: Dbl, U=0.55 42.00 ft2
13. Cooling systems kBtulhr Efficiency
SHGC: SHGC=0.34
a. Central Unit 46.5 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 3.165 ft.
14. Heating systems kBtulhr Efficiency
Area Weighted Average SHGC: 0.293
a. Electric Strip Heat 32.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) NIA ft2
15, Hot water systems
SHGC(AVG): NIA
a. Electric Cap: 50 gallons
9. Floor Types (1354.1 sqft.) Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation R=0.0 968.10 ft2
b. Conservation features
b. Raised Floor R=11.0 386.00 ft2
None
c. NIA R= ft2
16. Credits Pstat
Glass/Floor Area: 0.084 Total Proposed Modified Loads: 70.47 PASS
Total Baseline
Loads: 71.88 /`1
I hereby certify that the plans and specifications covered by
Review of the plans and i S74
this calculation are in compliance with th lorida Energy
specifications covered by this !�
Cade. i
F�
calculation indicates compliance �j`�' i,,, �'•1 = = �.�
�.
with the Florida Energy Code. a:Fr,��-E: - -t * `;.• `„p
PREPARED BY.
� ;`-
Before construction is completed
DATE: f
this building will be inspected for ,
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.<e,
with the Florida Energy Code.
(?0
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection
Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/16/2021 8:41 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
KHOV-EMERALD
Bedrooms: 5
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2321
Lot #
Owner Name:
EMERALD MODEL LOT 3 @
Total Stories: 2
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
KHOVNANAIN HOMES
Rotate Angle: 0
Street:
6128 ARMINA PL.
Permit Office:
Cross Ventilation, No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location
TMY Site
97.5 %
2,5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH—MUNI
39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1
Entire House
2321 19341.6
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
1
EXTRA SUITE
144 1267,2
No
2
5
1
No
Yes
Yes
2
EX SUITE BATH
60 528
No
0
1
No
Yes
Yes
3
FOYER
133 1173
No
0
1
No
Yes
Yes
4
GIRT DIN KITCHEN
630 5544
No
1
1
No
Yes
Yes
5
BED 4
174 1392
No
1
1
No
Yes
Yes
6
BED 3
167 1334
No
1
1
No
Yes
Yes
7
BED 2
162 1296
No
1
1
No
Yes
Yes
8
HALL LOFT
350 2800
No
0
1
No
Yes
Yes
9
LAUNDRY
48 384
No
0
1
No
Yes
Yes
10
MASTER SUITE
224 1792
No
2
1
No
Yes
Yes
11
MAST WIC
60 476
No
0
1
No
Yes
Yes
12
MASTER BATH
104 832
No
0
1
No
Yes
Yes
13
HALL BATH
65 518
No
0
1
No
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio
EXTRA SUITE
24 ft 0
144.8 W
----
0
1
0
2 Slab -On -Grade Edge Insulatio
EX SUITE BATH
6 ft 0
60 ftz
----
0
1
0
3 Slab -On -Grade Edge Insulatio
FOYER
20.5 ft 0
133.3 ft!
----
1
0
0
4 Slab -On -Grade Edge Insulatio
GRT DIN KITCHE
89 ft 0
630 fie
---_
0.5
0.5
0
6/16/2021 8:41 AM EnergyGauge® USA T0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value Area
Joist R-Value
Tile Wood Carpet
5 Raised Floor
BED 4 ---_ ---_ 174 ft2
11
0 0 1
6 Raised Floor
BED 3 -_-- --_- 167 ft2
11
0 0 1
7 Raised Floor
HALL LOFT -_-_ ---- 45 ft2
11
0 0 1
ROOF
/
Roof Gable Roof Rad
Solar SA Emitt
Emitt Deck Pitch
v # Type
Materials Area Area Color Barr
Absor. Tested
Tested Insul. (deg)
1 Hip
Composition shingles 1466 ft2 0 ft2 Medium N
0.9 No 0.9
No 0 22.62
ATTIC
v
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
1
Full attic
Vented
150
1353
ftz
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
1
Under Attic (Vented)
BED 4
30
Blown
174 ft2
2
Under Attic (Vented)
BED 3
30
Blown
167 ft2
3
Under Attic (Vented)
BED 2
30
Blown
162 ft2
4
Under Attic (Vented)
HALL LOFT
30
Blown
350 ft2
5
Under Attic (Vented)
LAUNDRY
30
Blown
48 ft2
6
Under Attic (Vented)
MASTER SUITE
30
Blown
224 ft2
7
Under Attic (Vented)
MAST WIC
30
Blown
60 ft2
8
Under Attic (Vented)
MASTER BATH
30
Blown
104 ft2
9
Under Attic (Vented)
HALL BATH
30
Blown
65 ft2
WALLS
Adjacent
Wall TypeSpace
Cavity Width
Height
1
E
Exterior Concrete Block
- Int InsEIXTRA SUIT
4.1 10
8 9
4
99.6 ft2
2
S
Exterior Concrete Block
- Int Ins&IXTRA SUIT
4A 11
8 10
0
116.7 ft2
3
S
Exterior Concrete Block
- Int InsEK SUITE BA
4.1 5
5 10
0
64.2 ft2
4
E
Exterior Concrete Block
- Int Insul FOYER
4.1 6
9 9
4
63.0 ft2
5
N
Exterior Concrete Block
- Int InsGRT DIN KIT
4.1 17
5 9
4
162.6 ft2
6
S
Exterior Concrete Block
- Int Ins12RT DIN KIT
4.1 16
2 10
0
161.7 ft2
7
W
Exterior Concrete Block
- Int Ins@RT DIN KIT
4.1 33
10 9
4
315.8 ft2
8
N
Exterior Frame - Wood
BED 4
11 13
8 8
10
120.7 ft2
9
E
Exterior Frame - Wood
BED 4
11 10
11 8
10
96.4 ft2
10
E
Exterior Frame - Wood
BED 3
11 10
11 $
10
96.4 ft2
11
E
Exterior Frame - Wood
BED 2
11 10
11 8
10
96.4 ft2
12
S
Exterior Frame - Wood
BED 2
11 12
3 8
10
108.2 ft2
13
N
Exterior Frame - Wood
HALL LOFT
11 7
3 8
10
64.0 ft2
I RCC
N
Framing Frac
Truss Type
0.1
Wood
❑.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
Sheathing Framing
Solar
Below
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
0 0
0.5
0
6/16/2021 8:41 AM EnergyGauge(D USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing
Solar Below
`14
S
Exterior
Frame - Wood
HALL LOFT
11 12
9
8 10
112.6 ft2
0
0
0.5 0
15
N
Exterior
Frame - Woad
MASTER SUi
11 13
2
8 10
116.3 ft2
0
0
0.5 0
16
W
Exterior
Frame - Wood
MASTER SUI
11 14
7
8 10
128.8 ft2
fl
0
0.5 0
17
W
Exterior
Frame - Wood
MASTER BA
11 11
10
8 10
104.5 ft2
0
0
0.5 0
18
S
Exterior
Frame - Wood
HALL BATH
11 10
0
8 10
88.3 ft2
0
0
0.5 0
19
W
Exterior
Frame - Wood
HALL BATH
11 5
5
8 10
47.8 ft2
0
0
0.5 0
_20
W
Garage
Frame - Wood
GIRT DIN KIT
11 38
0
9 4
354.7 ftz
0
0
0.5 0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
FOYER
None
.39
3
4
6 8
22.2 ft2
2
E
Wood
FOYER
None
.39
3
4
6 8
22.2 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation,
/
Wall
Overhang
#
Ornt
ID
Frame
Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screeni
1
E
1
Metal
Double (Tinted)
Yes
0.3
0.28
N
15,0 ft2
1 ft 0 in
12 ft 0 in
None
None
2
W
7
Metal
Double (Tinted)
Yes
0.3
0.28
N
32.0 ft2
1 ft 0 in
12 ft 0 in
None
None
3
W
7
Metal
Double (Tinted)
Yes
0.55
0.34
N
42.0 ft2
11 ft 0 in
1 ft 0 in
None
None
4
E
9
Metal
Double (Tinted)
Yes
0.3
0.28
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
5
E
10
Metal
Double (Tinted)
Yes
0.3
0.28
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
6
E
11
Metal
Double (Tinted)
Yes
0.3
0.28
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
7
N
13
Metal
Double (Tinted)
Yes
0.3
0.28
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
8
S
14
Metal
Double (Tinted)
Yes
0.3
0.28
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
9
W
16
Metal
Double (Tinted)
Yes
0.3
0.28
N
30.0 ft'
1 ft 0 in
1 it 0 in
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 386 ft2 386 ft2 64 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .00037 2255.9 123.76 232.35 .1694 7
6/16/2021 &41 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1 32 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 46.5 kBtulhr cfm
0.74 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
Garage
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None
None
ft2
DUCTS
/ ----
Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 250 ft2
HALL LOFT
1 ft2
Default Leakage
HALL LOFT (Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
HeatingX
Jan
Jan
Feb
Feb
Mar
Mar
A r
Apr
Ma
May
X
Jun
Jun
X Jul
Jul
AujXj
rl Au
Sep
Sep
Oct
OctX
�Xj
Nov
NovX
Dec
Dec
Venting
Jan
Feb
X
Mar
[X
A r
Ma
Jun
Jul
Aug
Se
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
80 80
80
8o
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68 68
68
68
68
68
68
68 68
66
66
Heating (VVEH)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Def2ult(8 lbs/sq.ft.
0 ft$
Oft
0.3
BED 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL BATH
Default(8 Ibslsq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibslsq.ft.
ft2
ft
0.3
BED 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BED 2
Default(8 Ibs/sq,ft.
ft2
ft
0.3
GRT DIN KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER SUITE
6/16/2021 8:41 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Default(8 Ibs/sq.ft,
Defaultf8 Ibs/sa ft
Area Thickness
f 2 ff
Furniture Fraction Space
0.3 MAST VViC
0.3 M BATH
6/16/2021 8:41 AM EnergyCauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX' = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows'* Description
a. U-Factor; Dbl, U=0.30
SHGC: SHGC=0.28
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.34
c. U-Factor: NIA
SHGC:
d. 1-1-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): NIA
SHGC(AVG): NIA
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. Raised Floor
c. NIA
5128 ARMINA PL., FORT PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insu€ation
Area
Detached
a. Frame -Wood, Exterior
R=11.0
1180.70 ft2
b. Concrete Block - Int Insul, Exterior
R=4.1
973.39 ft2
1
C. Frame - Wood, Adjacent
R=11.0
354.67 ft2
5
d. NIA
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1354.00 ft2
2321
b. NIA
R=
ft2
Area
c. NIA
R=
ft2
152.00 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: HALL LOFT, AH: HALL
LOFT
6 250
42.00 ft2
13. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
46.5 SEER:16.00
ftz
3.165 ft.
0.293
Area
ft2
Insulation Area
R=0.0 968.10 ft2
R=11.0 386.00 ft2
R= ft2
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtulhr Efficiency
32.0 COP:1.00
Cap: 50 gallons
EF: 0.95
Pstat
,y01JJisSJ,4 0
COL wB.
*Note: This is not a Building Energy Rating, If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/16/2021 8:41 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1