Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATION[7A "Building Our Quality Reputation One Customer At A Time" SCC131150472 Property Infonnation Owner: MICHAEL GOLDSMITH Address: 5503 EASTWOOD DR FORT PIERCE, FL 34951 Building Information Wind Zone: 170 MPH. Exposure Category: C Minimum Building Dimension: 28 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) 1 Int 26 62 7 37.5 -40.7 2 Int 53 62 _ 7 35.8 -39.0m 3 Int 26 ._62___ - 7 37.5 -40.7 4 End 72 61 7 35,1 -45.1 ._ 5 _._. End - - 72 61 7 35.1.___. _. -45.1 6 Int 35 38 7 37.8 -41.0 7 End 71 61 7 35.1 -45.2 8 End 25 36 7 37.8 -50.6 9 End 35 36 7 37.8 -50.6 Prepared in accordance with: ASCE 7-I6, Chapter 30, Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page Iof1