Loading...
HomeMy WebLinkAboutKSm Soil Compaction Report 8-31-21Headquarters 1W C IL t ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 &J jVL AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: August 31, 2021 KSM JOB #: 216917-1d/MH/jam NUC # 630 PERMIT #: 2104-0606 Nuc Model: MC-IDR-P Nuc Serial #: 30630 CONTRACTOR: R & E Loader Service JOB LOCATION: 5116 Silver Oak Drive Indian River Estates Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill - 1st & 2nd Lift TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 N.E. 0" - 1211 50 108.1 109.6 98.6% 2 S.E. I I 11108.3 1198.8% 3 Center I I 11107.9 1198.4% 4 N.W. I I 11108.0 1198.5% 5 S.W. I I 11108.0 1198.5% 6 N.E. 12" - 24" 11108.1 1198.6% 7 S.E. I I 11107.9 1198.4% 8 Center I I 11108.2 1198.7% 9 N.W. I I 11108.0 1198.5% 10 S.W. I I 11108.8 1199.3% Soil Description: Brown/Gray Sand In Place Moisture: 6.9 % Proctor Optimum Moisture: 10.0 % Proctor Max. Dry Density: P.C.F. 109.6 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: This Item has been electronically signed and aled by Julie Keller, P.E. FI. Lic.68366- the date stated directly t, the right using a digital signature. Printed copies bf this document are not nsi dered signed and sealed and the signature must be verified on any electronic copies. Digitally signed by Julie Keller Date: w 111.0 I I I I I I I E J-.. �..-.�.-.. ..-�..-.-.. ..-�.-.. I 110.0 . G I I I I I I I H 109.0 �..�..-.I.-..�..- .-.1-. -I.-.. T I I I I I I I P 108.0 �..-.i.-.. _i..-.�-..�. -i.-.. C 107.0 J-.. �..-.�. .._�..-. -.. ..-,.-.. I I I I I I I F 106.0 �..-4-..4-.._1..-.1-..+..-1.-.. I I I I I I I I p 105.0 -1..-.i-..T- I-..T. I'-.. Y 104.0 �.. �..-.�.-.. .._�..-.-.. ..-�.-.., 5 6 7 8 9 10 11 12 13 Moisture - % of Dry Weight 2021.09.01 Disclaimer: Contractor is responsible to maintain the tested area in the 13:36:01-04'00' condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Julie E. Keller, P.E. President PE# 68366 9/1/2021 Email to: mcarthuresther@bellsouth.net Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE