HomeMy WebLinkAboutRiveratone_prop_load calcPage 1 6/7/2021Residential Heat Loss and Heat Gain Calculation
In accordance with ACCA Manual J
Report Prepared By:
Central Air Systems Inc.
For:Riveratone prop
us 1 ft pierce
Ft pierce, fl
Design Conditions:Fort Pierce
Indoor:Outdoor:
Summer temperature:70 Summer temperature:90
Winter temperature:70 Winter temperature:42
Relative humidity:55 Summer grains of moisture:127
Daily temperature range:Medium
Building Component Sensible Latent Total Total
Gain Gain Heat Gain Heat Loss
(BTUH)(BTUH)(BTUH)(BTUH)
Duct 3,269 0 3,269 1,464
Floors 0 0 0 2,722
Walls 5,638 0 5,638 9,685
Ceilings 3,087 0 3,087 2,401
People 7,500 5,750 13,250 0
Fireplaces 0 0 0 0
Misc 1,200 0 1,200 0
Windows 12,298 0 12,298 6,728
Doors 1,028 0 1,028 1,220
Glassdoors 0 0 0 0
Skylights 0 0 0 0
Infiltration 1,936 4,009 5,945 6,528
Whole House 35,956 9,759 45,715 30,748
( 4 tons )
HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd.888 736-1101
Load calculations are estimates only, actual loads may vary due to weather and construction differences.