Loading...
HomeMy WebLinkAboutRiveratone_prop_load calcPage 1 6/7/2021Residential Heat Loss and Heat Gain Calculation In accordance with ACCA Manual J Report Prepared By: Central Air Systems Inc. For:Riveratone prop us 1 ft pierce Ft pierce, fl Design Conditions:Fort Pierce Indoor:Outdoor: Summer temperature:70 Summer temperature:90 Winter temperature:70 Winter temperature:42 Relative humidity:55 Summer grains of moisture:127 Daily temperature range:Medium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH)(BTUH)(BTUH)(BTUH) Duct 3,269 0 3,269 1,464 Floors 0 0 0 2,722 Walls 5,638 0 5,638 9,685 Ceilings 3,087 0 3,087 2,401 People 7,500 5,750 13,250 0 Fireplaces 0 0 0 0 Misc 1,200 0 1,200 0 Windows 12,298 0 12,298 6,728 Doors 1,028 0 1,028 1,220 Glassdoors 0 0 0 0 Skylights 0 0 0 0 Infiltration 1,936 4,009 5,945 6,528 Whole House 35,956 9,759 45,715 30,748 ( 4 tons ) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd.888 736-1101 Load calculations are estimates only, actual loads may vary due to weather and construction differences.