HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGss � 5a
8/16/2021 Florida Building Code Online
Business & Professional
i 6, Regulation
"..11111411111vigJim LVLQJ
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications ( contact Us BCIS Site Map d Links I Search
b
111000% d
u ,.
ss Product Approval
�= is USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL25621-R2
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL25621 R2 COI 26ga SnapMax 2lywood.pdf
Standard
TAS 100
TAS 125
UL 580
Year
1995
2003
2006
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 1071JGi 1 iolYgdSepo1 aWOZICDw56hlzFHg%3d%3d 1 /4
8/16/2021 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL #
12/16/2020
12/17/2020
12/26/2020
02/09/2021
25621 01: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" lywood or
3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No ( FL25621 R2 II 26ga SnapMax plywood.pdf f!
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A I Created by Independent Third Party: Yes
Design Pressure: +N/A/-97.25 ' Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AE 26ga SnapMax plywo if
! Created by Independent Third P . es
ina y 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
Plywood on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL25621 R2 II 032 SnapMax plywood.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-78.5
Evaluation Reports
Other: Refer to evaluation report
FL25621 R2 AE 032 SnapMax plywood.pdf
Created by Independent Third Party: Yes
25621.3 03: 032 Aluminum 12" SnapMax on
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
Plywood
with 12" coverage on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-69.25
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 II 032 SnapMax 12in Plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 032 SnapMax 12in Plywood.pdf
Created by Independent Third Party: Yes
1 25621.4 04: 26ga SnapMax on Plywood 126ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
j 3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R2 II 26ga SnapMax plywood D.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-121.75 Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AE 26ga SnapMax plywood D.pdf
Created by Independent Third Party: Yes
25621.5 05: 26ga SnapMax on Plywood HVHZ
269a (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
Limits of Use
3/4" (min) wood plank
Installation Instructions
i
Approved for use in HVHZ: Yes
FL25621 R2 II 26ga SnapMax plywood HVHZ.Wf-
Verified By: David Eng, PE 81377
1 Approved for use outside HVHZ: Yes
I Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-176
Evaluation Reports
Other: Refer to evaluation report
FL25621 R2 AE 26ga SnapMax plywood HV-iZ.pdf
Created by Independent Third Party: Yes
25621.6 1 06: 24ga SnapMax on Plywood i 24ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
I 1 3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-206
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 II 24ga SnapMax plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 24ga SnapMax plywood.pdf
Created by Independent Third Party: Yes
! 25621.7 1 07: 032 Aluminum SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
IPlywood on 15/32" (min) plywood or 3/4" wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621 R2 II 032 SnapMax plywood d.pdf
hops://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB107lJGiliolYgdSepolaWOZICDw56hlzFHg%3d%3d 2/4
8/16/2021
Florida Building Code Online
Approved for use outside HVHZ: Yes f Verified By: David Eng, PE 81377
1 Impact Resistant: N/A J Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5 j Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AE 032 SnapMax plywood d.pdf
Created by Independent Third Party: Yes
25621.8 08: 032 Aluminum SnapMax on
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
Plywood HVHZ
on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
1 Installation Instructions
Approved for use in HVHZ: Yes
FL25621 R2 II 032 SnapMax plywood HVHZ.pdf
Verified By: David Eng, PE 81377
Approved for use outside HVHZ: Yes
i Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-175
Evaluation Reports
I Other: Refer to evaluation report
FL25621 R2 AE 032 SnapMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.9
09: 26ga 19" TopMax on Plywood
26ga (min) TopMax 1.5" nail strip with 19" coverage on 15/32"
1 (min) plywood or 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL25621 R2 II 26ga TopMax 19in plywood.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-63.5
Other: Refer to evaluation report
Evaluation Reports
FL25621 R2 AE 26ga TopMax 19in plywood.pdf
Created by Independent Third Party: Yes
25621.10
10: 032 Aluminum TopMax on
plywood HVHZ
Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip
on 15/32" (min) plywood or 3/4" wood plank I
Limits of Use
Installation Instructions -------!
Approved for use in HVHZ: Yes
FL25621 R2 II 032 TopMax plywood HVHZ.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-179.5
Evaluation Reports
Other: Refer to evaluation report
FL25621 R2 AE 032 TopMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.11
11: 24ga TopMax on Plywood HVHZ
24ga (min) TopMax 1.5" nail strip on 15/32" (min) plywood or
_
3/4" (min) wood plank _ 1I
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL25621 R2 II 24ga TopMax plywood HVHZ.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
! Design Pressure: +N/A/-153.5
Evaluation Reports
Other: Refer to evaluation report
FL25621 R2 AE 24ga TopMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.12 112: 24ga 19" TopMax on Plywood
24ga (min) TopMax 1.5" nail strip with 19" coverage on 15/32"
fl HVHZ
(min) plywood or 3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: Yes
Installation Instructions
FL25621 R2 II 24ga TopMax 19in plywood HVHZ.pdf
I Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Design Pressure: +N/A/-116.25
Created by Independent Third Party: Yes
Evaluation
Other: Refer to evaluation report
Reports
FL25621 R2 AE 24ga TopMax 19in plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.13 13: 032 Aluminum 19" TopMax on
Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip
plywood HVHZ
with 19" coverage on 15/32" (min) plywood or 3/4" (min) wood
_�
plank
Limits of Use
Installation Instructions e
Approved for use in HVHZ: Yes
FL25621 R2 II 032 TopMax 19in plywood HVHZ.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-166.75
Evaluation Reports
Other: Refer to evaluation report
FL25621 R2 AE 032 TopMax 19in plywood HVHZ.prjf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. go right 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(i),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBl071JGi 1 iolYgdSepol aWOZICDw56hlzFHg%3d%3d 3/4
8/16/2021
Florida Building Code Online
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
rPIAFWW�—` ® ei: trzk
(credit Card
Safe
https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBl07lJGiliolYgdSepo1aWOZICDw56hlzFHg%3d%3d 4/4
EXTREMEMETAL
FABRICATORS
SKrUED CRAFFT ERS Ot= IKrT4L RCz+7PING SYSTFMS
26ga (min) SNAPMAX over 15/32" (min) plywood
Extreme Metal Fabricators
2160 SW Poma Dr I Palm City FL 34990
Product Description
Nailstrip, snaplock style panel with a 16" maximum panel width and a
nominal rib height of 1"
Product Material
26ga (min) steel
Corrosion resistant per FBC 1507.4.3 where required
Fastener
#10 x 1-inch pancake style fastener
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL
FL PE 81377 1 FL CA 33344
www.TimberLakeCove.com ti11t111tr
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Method A: #10 x 1" fastener at 6" o.c. along nail strip: 86 PSF
Method B: #10 x 1" fastener at 6" o.c. alona nail strip WITH sealant: 97.25 PSF
For Method B, use continuous 3/16" bead of Bostik 915 sealant or similar.
A factor of safety of 2 has been applied.
Fasteners are installed through the metal flange, NOT through the pre -punched slots.
Technical Documentation:
This product has been tested to the UL 580 standard by Architectural Testing (now Intertek
Testing, TST-1527), report D8133.01-450-18, as referenced in FL 17022.05-R7.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ), as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The some entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
Instructions:
Select the appropriate load table that applies to the
structure in question.
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept.
For the load tables below, the worst case was taken
for each zone and reported using the standard zones
1-2-3:
Zone 1 includes zones 1 and V
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple
scheme, at the expense of some design efficiency.
Contact the manufacturer for further information,
or consult a licensed design professional.
METHOD A
nQ�--
FEMALE LEG SNAPS
ONTO MALE LEG
#10 FASTENER
AT 6" O.C.
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
a: 10% OF LEAST HOIZONTAL DIMENSION OR 04h, WHICHEVER IS SMALLER, BUT NOT
LESS THAN EITHER 4%OF LEAST HORIZONTAL DIMENSION OR 3FT (a W),
OR AS DETERMINED BY DESIGN OR O'MER APPLICABLE CODE.
ROOF ZONES FOR GENERIC BUILDING
FEMALE LEG SNAPS
ONTO MALE LEG
�~�'•- SEALANT APPLIED TO
BASE OF TAN-E LEG
� #10 FASTENER
AT6"OC
NR: NOT RATED
CONSULT DESIGN
PROFESSIONAL AS
NECESSARY
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
FL25621.01: 26
a Snal2Max
on 15/32" plywood
FL25621.01: 26
a Snal2Max
on 15/32" plywood
Wind 105 110
120 130 140
150
160 170 180 190 2001
Wind 105
110 120 130
140 150 160 170 180 190 200
Zone 1: A A
A
A
A
A
A A A A A I
Zone 1: A
A A
A
A A A B
Zone 2: AAA
AAAAA
B
Zone 2: A
A A
A
V.
B
Zone 3: A A
A
A
A
A
B HM��ggl
Zone 3: A
A A
B
.
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B, C, or D exposure area
Have either a flat roof less than 70, hip roof with Have either a flat roof less than 7°, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less