Loading...
HomeMy WebLinkAboutEVALUATION REPORTURNER ENGINEERING & CONSULTING, INC. Product Description: Series 42-19 Vinyl Fixed Impact Window 2428 Old Natchez Trace Trl. Camden, TN 38320 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report IN0551-R2 December 8, 2020 Manufacturer: Simonton Windows, 1 Cochrane Ave., Pennsboro, WV Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 71h Edition (2020) Florida Building Code outside the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 2428 Old Natchez Trc Trl, Camden, TN 2) Installation drawing IN0551-R2, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports B7590.01-501-47-rl and C9032.01-501-47-r0 from Architectural Testing, Inc., Springdale, PA, and test report T255-10 from Farabaugh Engineering & Testing, Inc., McKeesport, PA, with testing performed: AAMA/WDMA/CSA 101/I.S.2/A440-05/08, ASTM E1886-05/E1996-09 4) Supplemental Calculations to support IN0551-R2, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to installation drawing IN0551-R2. Limitations of Use: This product: a May be used in the configurations, product sizes, and with glazing as indicated in IN0551-R2 • Is large missile impact resistant (missile level C, wind zone 2) and does not require the use of shutters in windborne debris regions meeting missile level C, wind zone 2 criteria v May not be used in the High Velocity Hurricane Zone • Requires white SimEx, Inc. PVC extrusions with current listing as an AAMA Certified Profile Licensee under AAMA 303 Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Simonton Windows or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. e��'►)pj S Al. Lucas Turner No 58201 2020.12.08 11:43:07 = D= gfits Z .00 STATE OF ` Zz Z �rr191�1 zz 12/8/2020 Lucas A. Turner, P.E. FL PE #58201 1 FGI en vlotiog I'7djsLfy Alliance Simonton Windows 1 Cochrane Dr. Pennsboro, WV 26415 Attn: Tina Seese AAMA CERTIFICATION PROGRAM An FGIA Product Certification Program AUTHORIZATION FOR PRODUCT CERTIFICATION This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory. SPECIFICATIONS RECORD OF PRODUCT TESTED AAMA/WDMA/CSA 1011I.S.2/A440-11 AAMA 506 R-PG50-1842xl880 (73x74)-FW Missile Level: C CPD SERIES MODEL & PRODUCT MAXIMUM SIZE COMPANY AND CODE Rating: +501-50, 73x74 NO. DESCRIPTION TESTED Wind Zone: 2 Rating above conforms 42-19 TWIN PW FRAME Simonton Windows to the requirements of: 8578 (PVC)(00)(IG) 1842 mm x 1880 mm Code: SIM ASTM El886 (INS TEMP/0.090" PVB LAM GL) (6'1" x 612") and E1996 (REINF)(ASTM) This Certification will expire March 6, 2026 (extended from March 6, 2021 per AAMA 103-19) and requires validation until then by continued listing in the current AAMA Certified Products Directory. Structural Test & Report By: Missile Impact Test & Report By: Architectural Testing, Inc. Architectural Testing, Inc. Report No: B7717.01-501-47 Report No: B8442.01-501-47 Date of Report: March 29, 2012 Date of Report: April 19, 2012 (Revised June 11, 2012) Evaluated for Certification: September 14, 2020 'h' 4_�iL Adocited Laboratories, Inc. • Authorized for Certification: September 14, 2020 (Validator / Operations Administrator) C�T" ACP-04 (Rev. 2/20) FeneNdation and Glazing Industry Alliance MODEL DESIGNATION: MAXIMUM OVERALL NOMINAL SIZE: DESIGN PRESSURE RATING: USABLE CONFIGURATIONS_ GENERAL DESCRIPTION: Simonton Impact Resistant Fixed Twin Series 42-19 Vinyl Window Twin up to 73" X 74" Positive: 50.0 PSF Negative: 50.0 PSF 00 The head, sill, and side jambs are extruded PVC. The wall thickness through which the anchor screw penetrates is a minimum of 0.070". MAX. (TYP.) MAX. -r Q #6 X 1 1MIN. Nil WOOD SCREW,EW, TYP. FLANGE TO BUCK I o I I I I I v W S >< G I i o- ¢ � 0 a ^ I I I I I I I I I I I I I I I I I I rn L — — — — — — — — — MtAXOVERALL73" FRAME WIDTH REV. REVISIONS: REVISED BY: DAZE: NO P.E. SEAL REQUIRED k. 1 ADDED MIN. EDGE DIST. NOTE B.J.S. 6/17/1 INSTALLATION SUPPORTED BY AAMA TEST REPORTS 2 UPDATED FOR 77H EDITION 2020 FBC. LMH 12/06/: #6 X 1 1/4" MIN. WOOD SCREW WITH 1.00" MIN. EMBEDMENTINTO WOOD 2X BUCK MIN. EDGE DIST., SEE NOTES INTERCEPT STEEL SPACER SYSTEM WITH SINGLE BUTYL SEAL SILICONE CAULK ❑ 1/8" TEMPERED AIR SPACE 4 /8" ANNEALED 1/4" MAX. SHIM 0.090" SOLUTIA PVB SIDCONE CAULK 1/8" ANNEALED PECORA 896—HIS 0.600" GLASS BITE GLAZING COMPOUND HEAD 1/4" MAX. SHIM SILICONE CAULK SILICONE CAULK #5 X 1 1/4" MIN. WOOD SCREW WITH 1.01)" MIN. EMBEDMENTINTO WOOD 2X BUCK MIN. EDGE DIST., SEE NOTES 7/8" INSULATED TEMPERED/ANNEALED IMPACT GLASS WITH 0.090" PVB INTERLAYER 2X BUCK 1/4" MAX. SHIM—,_ I \ / I SILICONE CAULK #6 X 1 1/4" MIN. WOOD SCREW WITH 1.00" MIN. EMBEDMENTINTO WOOD MIN. EDGE DIST., SEE NOTES SILICONE CAULK SILL JAMB NOTES: 1. This installation has been evaluated for use in locations adhering to the Florida Building Code and where pressure requirements as determined by ASCE 7 Minimum Design Loads for Buildings and Other Structures do not exceed the design pressure ratings herein, for use outside the H.V.H.Z. 2. All exterior perimeter surfaces of the window must be caulked. Interior caulking is optional unless noted otherwise. 3. Anchors shall be as specified and spaced as shown. Anchor embedment to base material shall be beyond wall dressing or stucco and Into wood. 4. The responsibility for selection of Simonton products to meet any applicable local laws, building codes, ordinances, or other safety requirements rests solely with the architect, building owner, or contractor. 5. Shims are optional. Maximum shim stack is 1/4". 6. Wood bucks (by others) must be engineered and anchored properly to transfer loads to the structure. 7. When used in areas requiring impact protection this product DOES NOT REQUIRE the use of approved impact resistant shutters or other external protection. 8. Flashing should be applied using the ASTM E 2112 methodology appropriate for the opening into which the window is being installed. 9. Glazing shall comply with ASTM E 1300. 10. Installation screws must be at least 1/2" from edge of the wood. DISCI OSURF STATEMENT This document Is the property of Simonton Windows, which retains all proprietary and other rights to its subject matter. This document is provided to the recipient on the expressed :ondltion that it Is not to be disclosed, reproduced In whole of part, nor used In conjunction with the design, manufacture or repair of goods for anyone other than Simonton windows without Its consent. This restriction does not limit the recipient's right. to utilize Information contained In this document which Is properly obtained from another source. Dlmensional Tolerances Unless Otherwise Soeairied Decimals Angles .x d:.03 .xx :h .01 0' 3D min. .Xxx d:.005 0 SIMONTON' 1 Cachmnc A -me Pennsbnro, WV 26415 I nT 1 1 of 1 1 1 1 WINDOW TWIN 1 �.