Loading...
HomeMy WebLinkAboutSurveyP.O.B. FENCE SET 518" IRON 73E, 0.3'N ROD AND CAP 33.0' 'NEX 8111" ) r �, o"v. (i L0 Q a C!] U' >II r O O O } O CV O O O 33.0' Eu 0 os Lam( ) o O o C? z ¢ `' o � F- —j `V 1W N 00 00' 00"E",125.00' (D� D ASSUME= u. ¢ FOUND 1/2" SET 5/8" IRON BEARING ~ \\—IRON ROD ROD AND CAP N890 10' 30"E 9 "NEXGEN 8111" 33.00' (D) REMAINDER OF SECTION 33-35-39 ( NOT INCLUDED) 5601 CORPORATE WAY, SUITE 103 WEST PALM BEACH, FL 33407 NexgenSurveying.com LB#8111 PHONE: 561.508.6272 FAX: 561.508.6309 V FOUND 1/2" IRON ROD REMAINDER OF SECTION 33-35-39 ( NOT INCLUDED) ° 00' 00" V,/ 296,59' (D) �y R WELL +1 R C) a c;, 47.3' 5.0' 10.1 CV _ P1T6 cl2.0 RESIDENCE O - o # 4220 U N co 35.3' I: ySHED _I 80.2' 11 PORTION OF SECTION 33-35-39 (INCLUDED) '13 ENJ SURVEYING, LLC. 153.8' Line Table Line # Length Direction L1 25.00' N90" 00' 00"E 12 25.00' S00" 00' 00"E L = 147.01' W&R)' p=73405 MIN: SETBACK FRONT SIDESCNR SIDES TECH, FOUND 1/2" IRON ROD 1.1'E, 2.0'S FENCE FILE 1.1E 2.0S - OPY GENERAL NOTES: 1) THIS SURVEY IS BASED UPON RECORD INFORMATION BY CLIENT. NO SPECIFIC SEARCH OF THE PUBLIC RECORD HAS BEEN MADE BY THIS OFFICE UNLESS OTHERWISE NOTED. 2) IF THIS SURVEY HAS BEEN PREPARED FOR THE PURPOSES OF MORTGAGE TRANSACTION, ITS SCOPE IS LIMITED TO THE DETERMINATION OF TITLE DEFICIENCIES. NO FUTURE CONSTRUCTION SHALL BE BASED UPON THIS c? SURVEY WITHOUT FIRST OBTAINING APPROVAL AND/OR M UPDATES FROM NEXGEN SURVEYING, LLC. NEXGEN t7 c� SURVEYING, LLC, ASSUMES NO RESPONSIBILITY FOR L6 Z ERRORS RESULTING FROM FAILURE TO ADHERE TO THIS O CLAUSE. CV F- 0 3) ANY FENCES SHOWN HEREON ARE ILLUSTRATIVE OF W THEIR GENERAL POSITION ONLY. FENCE TIES SHOWN ARE kLj a) U TO GENERAL CENTERLINE OF FENCE. THIS OFFICE WILL p LO NOT BE RESPONSIBLE FOR DAMAGES RESULTING SOLELY O C,� O ON THEIR PHYSICAL RELATIONSHIP TO THE MONUMENTED Lu Z BOUNDARY LINES. CD Z v 4) GRAPHIC REPRESENTATIONS MAY. HAVE BEEN o Q EXAGGERATED TO MORE CLEARLY ILLUSTRATE O :E MEASURED RELATIONSHIPS - DIMENSIONS SHALL HAVE zPRECEDENCE OVER SCALED POSITIONS. 5) UNDERGROUND IMPROVEMENTS HAVE NOT BEEN LOCATED EXCEPT AS SPECIFICALLY SHOWN. 6) ELEVATIONS ARE BASED UPON NATIONAL GEODETIC VERTICAL DATUM (N.G.V.D.1929) OR NORTH AMERICAN VERTICAL DATUM (NAV.D.1988). 7) ALL BOUNDARY AND CONTROL DIMENSIONS SHOWN ARE FIELD MEASURED AND CORRESPOND TO RECORD INFORMATION UNLESS SPECIFICALLY NOTED OTHERWISE. B) CORNERS SHOWN AS'SET-518- IRON RODS J IDENTIFIED WITH A PLASTIC CAP MARKED LS (LICENSED SURVEYOR) I HEREBY CERTIFY THAT THIS SURVEY MEETS OR EXCEEDS THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS PER CHAPTER 5J-17, FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027, FLORIDA STATUTES. SET 5/8" IRON ROD AND CAP "NEXGEN 8111" SHEET 1 OF 1 CLYDE 0. MCNEAL PSM.2883 THIS SURVEY IS NOT VALID WITHOUT THE SIGNATURE AND RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER