Loading...
HomeMy WebLinkAboutEVALUATION REPORTC �Il� Registry 29 �� 17520 Edinburgh urghh Dr Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC ' , ® ®Q 13) 480-3421 CC ��11►OV/ EVALUATION REPORT EVALUATION REPORT t���T" (2020) Manufacturer: Duro-Last Roofing, Inc. � C'E C�i1s * 13, 2021 525 Morley Drive BCC Saginaw, MI 48601 989-737-3043 www.duro-last.com Manufacturing Plants: Saginaw, MI Jackson, MS Sigourney, IA Quality Assurance: UL LLC (QUA1743) SCOPE Category: Roofing Subcategory: Single Ply Roof System Code Edition: Florida Building Code, 7th Edition (2020) including High -Velocity Hurricane Zones (HVHZ) Code Sections: 1504.3.1, 1504.6, 1507.13.2, 1515.1.1, 1515.1.4, 1523.1.1, 1523.6.2 Properties: Wind Resistance, Physical Properties PRODUCT DESCRIPTION Products Specification Description Duro-Last Designer Series ASTM D 4434 Nominal 50-mil thick single -ply roof membrane composed of a Membrane thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim. The membranes are available as Rock -Ply® and Shingle -Ply® prefabricated sections or roll goods. Duro-Last Membrane ASTM D 4434 Nominal 40-mil (DL40), 50-mil (DL50), 60-mil (DL60) or 80-mil (DL80) thick single -ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim. The membranes are available as prefabricated sections or roll goods. Duro-Fleece Membrane ASTM D 4434 Nominal 50-mil (DF50), 60-mil (DF60), or 80-mil (DF80) thick single -ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim and backed with fleece. Duro-Tuff membranes are available in the following colors: White for all thickness, and Blue, Copper, Charcoal, Green, Light Gray, Patina,.and Light Tan for DF50 and DF60 only The membranes are available as roll goods. Duro-Fleece Plus Membrane ASTM D 4434 Nominal 50-mil (DFP50) or 60-mil (DFP60) thick single -ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim and backed with fleece. The membranes are available as roll goods. Duro-Tuff Membrane ASTM D 4434 Nominal 50-mil (DT50), 60-mil (DT60), or 80-mil (DT80) thick single -ply roof membrane composed of a thermoplastic polyvinyl chloride film laminated to both sides of a polyester fabric scrim. Duro-Tuff membranes are available in the following colors: White for all thickness, and Blue, Copper, Charcoal, Green, Light Gray, Patina, and Light Tan for DT50 and DT60 only. The membranes are available as roll goods. DLR12001.17 FL16039-R17 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC REFERENCES Entity Architectural Testing, Inc. (TST1558) Architectural Testing, Inc. (TST1558) Certified Testing Laboratories (TST1577) Certified Testing Laboratories (TST1577) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) Report No. B8983.01-106-18 C0713.01-19.18 CTLA 107R CTLA 107R-A DLRI-013-02-01 DLRI-014-02-01 DLRI-018-02-01 DLRI-021-02-01.17 DLRI-041-01 DLRI-029-02-01 DLRI-030-02-01 DLRI-041-02-01 DLRI-045-02-01 DLRI-045-02-02 DLRI-046-02-01 DLRI-047-02-01 DLRI-053-02-01 DLRI-055-02-01 DLRI-058-02-01 DLRI-063-02-01 DLRI-068-02-01 DLRI-073-02-01 DLRI-073-02-02 DLRI-077-02-01 DLRI-077-02-02 DLRI-079-02-01.1 DLRI-082-02-01 DLRI-086-02-01 DLRI-086-02-02 DLRI-096-02-01 DLRI-096-02-02 DLRI-099-02-01 DLRI-100-02-01 DLRI-113-02-01 DLRI-114-02-01 DLRI-115-02-01 DLRI-119-02-01 DLRI-119-02-02 DLRI-120-02-01 DLRI-123-02-01 DLRI-124-02-02 DLRI-126-02-01 PRI Construction Materials Technologies (TST5878) DLRI-126-02-02 PRI Construction Materials Technologies (TST5878) DLRI-126-02-03 PRI Construction Materials Technologies (TST5878) DLRI-128-02-01 PRI Construction Materials Technologies (TST5878) DLRI-130-02-01 PRI Construction Materials Technologies (TST5878) DLRI-130-02-02 DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes Standard TAS 117(A) (1995� TAS 114(J) (2011 ) TAS 114 (J)(2011) TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011) ASTM D 1761 (2006); TAS 117(A) & (B) (1995); FM 4474 (2011); TAS 114(D) (2011); TAS 114(H)(1995) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(B) (2011); TAS 114(D) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(B) (2011); TAS 114(D) (2011) FM 4474(B) (2011); TAS 114(D) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011) ASTM D 4434 (2012); ASTM G 155 (2013) ASTM D 4434 (2012); ASTM G 155 (2013) FM 4474(B) (2011); TAS 114(D) (2011) FM 4474(B) (2011); TAS 114(D) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(B) (2011); TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) FM 4474(D) (2011); TAS 1'14(J) (2011); UL 1897 (2012) TAS 114(D) (2011) TAS 114(D) (2011) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) ASTM D 4434 (2012) ASTM D 4434 (2012) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) TAS 114(D) (2011) TAS 114(D) (2011) TAS 117(B) (1995) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) DLR12001.17 FL16039-R17 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 6 CREEK DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes TECHNICAL SERVICES, LLC Entity Report No. Standard PRI Construction Materials Technologies (TST5878) NGC-034-02-01 FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) NGC-035-02-01 FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) NGC-038-02-01 FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) NGC-041-02-01 FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) 280T0005 FM 4474(D) (2011); TAS 114(J) (2011); UL 1897 (2012) PRI Construction Materials Technologies (TST5878) 280T0011 FM 4474(B) (2011); TAS 114(D) (2011); PRI Construction Materials Technologies (TST5878) 280T0012 FM 4474(B) (2011); TAS 114(D) (2011); Trinity ERD (TST6049) 02733.01.05-1 FM 4470 (2016); TAS 114(J) (2011) Trinity ERD (TST6049) 02744.05.06 FM 4470 (2016); TAS 114(J) (2011) Trinity ERD (TST6049) D6760.08.07 FM 4470 (2016); TAS 114(J) (2011) Trinity ERD (TST6049) 02750.02.08 ASTM D 4434 (2012) Trinity ERD (TST6049) 02762.03.05 TAS 114(D & J) (2011); TAS 114( H ) (1995) Trinity ERD (TST6049) D35210.08.11-R3 ASTM D 4434 (2012) Trinity ERD (TST6049) D40260.03.13-1 TAS 110 (2000) Trinity ERD (TST6049) D40280.03.13 TAS 110 (2000) Trinity ERD (TST6049) D42320.08.12 FM 4474(D) (2012); TAS 114(J) (2011) Trinity ERD (TST6049) D44450.05.13-2 ASTM D 4434 (2012) FM Approvals (TST1867) J.I. 2M4A8 .AM FM 4470 (2016) FM Approvals (TST1867) J.I. 3Y5A6 .AM FM 4470 (2016) FM Approvals (TST1867) J.I. 1X2A7 .AM FM 4470 (2016) FM Approvals (TST1867) 4D6A4.AM FM 4470 (2016) FM Approvals (TST1867) 3005604 FM 4470 (2016) FM Approvals (TST1867) 3006989 FM 4470 (2016) FM Approvals (TST1867) 3008342 FM 4470 (2016) FM Approvals (TST1867) 3010289 FM 4470 (2016) FM Approvals (TST1867) 3010987 FM 4470 (2016) FM Approvals (TST1867) 3014929 FM 4470 (2016) FM Approvals (TST1867) 3015816 FM 4470 (2016) FM Approvals (TST1867) 3023458 FM 4450 (1989) FM Approvals (TST1867) 3026128 FM 4470 (2016) FM Approvals (TST1867) 3026508 FM 4450 (1989) FM Approvals (TST1867) 3032172 FM 4470 (2016) FM Approvals (TST1867) 3033314 FM 4470 (2016) FM Approvals (TST1867) 3040346 FM 4470 (2016) FM Approvals (TST1867) 3044466 FM 4470 (2016) FM Approvals (TST1867) 3040741 FM 4470 (2016) FM Approvals (TST1867) 3050118 FM 4470 (2016) FM Approvals (TST1867) 3054028 FM 4470 (2016) FM Approvals (TST1867) 3063970 FM 4470 (2016) FM Approvals (TST1867) PR455277 FM4470 (2016) 'Standard test method has been found equivalent to FM 4474 (2004) referenced by the FBC. DLR12001.17 FL16039-R17 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 6 CREEK DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes TECHNICAL SERVICES, LLC LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. The roof deck and the roof deck attachment information are provided based on testing. FBC requirements for the rational design of the roof deck, including the attachment, are not within the scope of this evaluation. 3. Foam plastic insulation shall be installed in accordance with the FBC Section 2603.4. 4. In the HVHZ, fastener spacing for insulation attachment is determined using a Minimum Characteristic Force (F') of 275 Ibf as demonstrated via testing to TAS 105. If the field tested fastener value is below 275 Ibf, then insulation attachment shall not be acceptable. 5. In the HVHZ, fastener spacing for base sheets or membrane attachment shall meet the minimum fastener resistance value and the MDP for the specified roof system. It is permissible for a qualified professional to submit a revised fastener spacing utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137, when the fastener resistance is found less than required. 6. In the HVHZ, if mechanical attachment through the lightweight insulating concrete to the structural deck is proposed, a field fastener withdrawal test shall be conducted in compliance with TAS 105 to determine equivalent or increased attachment densities. Revised fastener densities shall be submitted utilizing the withdrawal resistance value obtained from TAS 105 testing and calculations performed in accordance with RAS 117 and/or RAS 137. 7. HVHZ: For assemblies containing mechanical attachment, the allowable uplift pressure for the selected assembly shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16. The attachment density may be increased by a qualified design professional, as necessary, to meet the design pressure requirements in the periphery zones. Calculations shall be conducted in compliance with RAS 117 and/or RAS 137. Non-HVHZ: For assemblies containing mechanical attachment or adhered in ribbon -applied adhesive, the allowable uplift pressure for the selected assembly shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16. The attachment density may be increased by a qualified design professional, as necessary, to meet the design pressure requirements in the periphery zones. Calculations shall be conducted in compliance with RAS 117, RAS 137, or Section 2.2.10.1 FM LPDS 1-29 (February 2020). 8. Reroofing applications shall be examined in accordance with FBC Section 1511 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened roof systems, a field withdrawal resistance test (TAS 105 in the HVHZ; ANSI/SPRI FX-1 or TAS 105 in the non-HVHZ) shall be conducted by a qualified professional to ensure the fastener meets the minimum design load requirements of the roof system. For adhered roof systems, a field uplift resistance test (TAS 124 in the HVHZ; ASTM E 907, FM LPDS 1-52, ANSI/SPRI IA-1, or TAS 124 in the non-HVHZ) shall be conducted to confirm conformance of the existing to the minimum design loads. 9. HVHZ: For assemblies containing fully adhered or ribbon adhered attachment, or where extrapolation of the assembly is not permitted, the MDP for the selected assembly shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16 without augmentation. Non-HVHZ: For assemblies adhered in ribbon -applied adhesive, the allowable uplift pressure for the selected assembly shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16. The attachment density may be increased by a qualified design professional, as necessary, to meet the design pressure requirements in the periphery zones. Calculations shall be conducted in compliance with Section 2.2.10.1 FM LPDS 1-29 (February 2020). 10. Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 11. The minimum roof slope shall be 1/4:12 for new construction. 12. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. 13. Fasteners applied in rows may impart concentrated loads to structural components of the building. Designers should consider the fastener spacing of the roof system in relation to the spacing of structural supports when selecting a roof system. DLR12001.17 FL16039-R17 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7ch Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. R. �v\C E N SF �>•��� No 74021 = it � � STATE OF .!4U �N AL� %. �nnl� This item has been digitally signed and sealed by Zachary R. Priest, PE, on 4/13/2021. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. CERTIFICATION OF INDEPENDENCE k_. 2021.04.13 15:11:57 . �gmry.y-lpambRMru � v •-.� •..• .. -04'00' Zachary R. Priest, P.E. Florida Registration No: 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A— Installation (8 pages) 2) APPENDIX B — Nomenclature and Approved Assemblies (35 pages) DLR12001.17 FL16039-R17 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKPVC Single -Ply ROOFING, INC. Roofing Membranes TECHNICAL SERVICES, LLC APPENDIX A INSTALLATION Note - Refer to the APPROVED ASSEMBLIES section of this report for specific installation details of a selected roof system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail Dispensed using application gun for 2 full seconds into 7/16- Dow ENERFOAMT"° Foam Sealant inch pilot hole drilled to a depth of 2.5-inch; Fasteners installed within 20-40 seconds after dispensing Duro-Bond Plate 1302 3-inch induction welding plate for PVC membranes; welds not Duro-Bond PVC IW Plate permitted at lap seams Duro-Last 3-inch Metal Plates 3-inch x 3-inch square; 0.024-inch thick Galvalume steel Duro-Last #14 Concrete Screw Min. 1.25-inch penetration into concrete Duro-Last Cleat Plates Min. 2 3/8-inch diameter, 0.035-inch thick steel plate with cleats Duro-Last Duro-Coated Hex Head Min. 1.25-inch penetration into concrete Screws Duro-Last Fluted Concrete Nail Min. 1.25-inch penetration into concrete #14 screw; Min. 1-inch penetration into No. 2 wood truss; Min. Duro-Last #14 HD Fastener 3/4-inch penetration through the top rib of the steel deck or through wood deck Duro-Last 415 Extra Heavy Duty Drill #15 screw; Min. 3/4-inch penetration through the top rib of the Point Fastener steel deck or through wood deck Duro-Last Auger Fastener Min. 2-inch penetration into substrate Fasteners & Plates Duro-Last Auger Plates Min. 2-inch diameter steel plate Duro-Last Poly -Plate Min. 2-inch diameter, 0.335-inch thick glass -filed polycarbonate plate with cleats OMG XHD Fastener #15 screw; Min. 3/4-inch penetration through the top rib of the steel deck or through wood deck TRUFAST FM-90 Base Sheet Fastener 2.7-inch steel plate with dual grip shanks; Min. 1.7-inch penetration into substrate; TRUFAST Twin Loc Coiled Batten Bar 100 ft. long, 1-inch wide, 0.040-inch thick Galvulume coil with pre -punched holes 3-inch o.c. TRUFAST DP #12 Fastener #12 screw; Min. 3/4-inch penetration through the top rib of the steel deck TRUFAST 3" Metal Insulation Plate Min. 3-inch diameter steel plate TRUFAST Twin Loc-Nail Assembled 2.7-inch steel disk with locking staple; Min. 1.8-inch penetration Fastener into substrate TRUFAST Twin Loc-Nail Batten Locking staple; Min. 1.8-inch penetration into substrate; for use Fastener with TRUFAST Twin Loc Coiled Batten Bar TRUFAST VERSA -FAST Fastener Min. 2-inch embedment into LWIC or Gypsum decks 3-inch diameter; 0.017-inch thick Galvalume steel plate with TRUFAST VERSA -FAST Metal Plate one (1) center hole and eight (8) equally spaced perimeter holes for multiple fastening. Continuus ReWall Closed Loop Roof Min 1/2-inch thick roof board with recycled plastic/cellulose Cover Board with coated fiberglass facer core and coated fiberglass facer Insulation DEXcell FA Glass Mat Roof Board Min. 1/4-inch thick gypsum roof board with fiberglass facer DEXcell Cement Roof Board Min. 7/16-inch thick cement roof board with glass mesh DLR12001.17 FL16039-R17 Page 1 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX A Component Product Installation Detail Min. 0.5-inch thick; Extruded polystyrene (XPS) with Duro-Fold Underlayment Board polypropylene facer; Adhered boards shall be a maximum 4-ft x 4-ft Duro-Guard EPS Min. 0.5-inch, min. 1.8 pcf EPS (HVHZ) or min. 1.5 pcf EPS (non-HVHZ); Adhered boards shall be a maximum 4-ft x 4-ft Duro-Guard EPS Fan Fold Min. 0.5-inch, min. 1.25 pcf EPS board with polymeric film facer (non-HVHZ only) Min. 0.5-inch, min. 1.8 pcf EPS (HVHZ) or min. 1.5 pcf EPS Duro-Guard EPS Fiberglass Facer (FGF) (non-HVHZ only) with fiberglass facer; Adhered boards shall be a maximum 4-ft x 4-ft Duro-Guard XPS Fan Fold Min. 0.5-inch thick; Extruded polystyrene (XPS) with polymeric facer; Adhered boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO II -A Duro-Last Duro-Guard ISO II-G Duro-Last Duro-Guard ISO II-H Duro-Last Duro-Guard ISO III -A Min. 0.5-inch thick; Min. 20 psi polyisocyan u rate board with Duro-Last Duro-Guard ISO III-G various facers; Adhered boards shall be a maximum 4-ft x 4-ft Insulation Duro-Last Duro-Guard ISO III-H (Cont'd) Duro-Last Duro-Guard ISO IV -A Duro-Last Duro-Guard ISO Foil Duro-Last Duro-Guard ISO HD Min. 2-inch thick composite polyisocyan u rate board; Adhered Composite boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO HD -A Min. 0.5-inch thick; Min. 90 psi polyisocyanurate board with Duro-Last Duro-Guard ISO HD-G coated fiberglass facers; Adhered boards shall be a maximum 4-ft x 4-ft Duro-Last Duro-Guard ISO HD-H Georgia-Pacific De MsDeck, Dens Deck Min. 0.25-inch thick gypsum roof board with fiberglass facer; Prime with EON ICTm Technology Min. 0.25-inch thick; Min. 150 psi polyisocyanurate with coated JM Invinsa Roof Board fiberglass facers; Adhered boards shall be a maximum 4-ft x 4- ft Min. 0.5-inch ASTM C 578 Type IX (HVHZ) or Type II (non- Insulfoam R-Tech Fan Fold HVHZ) Expanded Polystyrene with polymeric facers; Adhered boards shall be a maximum 4 ft x 4 ft USG SECUROCK Gypsum -Fiber Roof Min. 0.25-inch thick gypsum roof board with fiber Board reinforcement; Olybond Classic Applied in 3/4 to 1-inch wide ribbons Duro-Grip Board -Max Apply in 3-inch wide ribbons Duro-Grip CR-20 Adhesive Apply in 3/4 to 1-inch wide ribbons Insulation Adhesive Duro-Grip Insta Stik Apply in 3/4 to 1-inch wide ribbons Duro-Grip OlyBond 500 Apply in 3/4 to 1-inch wide ribbons Duro-Grip Trufast Apply in 3/4 to 1-inch wide ribbons Duro-Grip One Step Apply in 1/2 to 3/4-inch wide ribbons Duro-Fleece CR-20 Membrane Adhesive Fleeceback products only; Apply in spatter pattern at a rate of 3.5 Ibs/100-ft Membrane Adhesive Duro Fleece Membrane Adhesive Fleeceback products only; Apply in 3/4-inch wide ribbons spaced maximum 4-inch o.c. DLR12001.17 FL16039-R17 Page 2 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX A Component Product .Installation Detail Duro-Fleece OMG Canister Membrane Fleeceback products only; Apply in spatter pattern at a rate of Adhesive 3 Ibs/100-ft2 Duro-Fleece Trufast Membrane Fleeceback products only; Apply in spatter pattern at a rate of Adhesive 3 Ibs/100-ft2 Duro-Last SB IV Adhesive Barebacked products only; Fully adhere at a combined rate 60-ft2/gal (Apply 120-ft2/gal to both membrane and substrate). Coverage will vary depending on porosity of substrate. Membrane Adhesive (Cont'd) Duro-Last Solvent -Grip Spray Adhesive Barebacked products only; Spray -applied in a contact application method at a rate of 3.0 Ib/sq to both the substrate and the underside of the membrane; total rate of 6.0 lb/sq. Fleece backed membranes: Fully adhere at a rate of 100-ft2/gal to substrate only. Coverage will vary depending on porosity of Duro-Last WB II Adhesive substrate. 2 Barebacked membranes: Fully adhere at a rate of 140-ft /gal to substrate only. Coverage will vary depending on porosity of substrate. Min. 1.5-inch welded lap seam for adhered and induction Duro-Last Membrane welded systems; Side -laps shall be installed parallel to the direction of the wood trusses for mechanically attached systems over wood decks; Side -laps shall be installed perpendicular to the direction of the steel deck ribs for Duro-Fleece Plus Membrane mechanically attached systems over steel deck; For in -lap attachment, the center of the plate shall be 1 1/4-inch from the Single -Ply tab edge. Membrane Min. 4-inch lap for mechanically fastened systems with min. Duro-Tuff Membrane 1.5-inch welded lap seam; Min. 1.5-inch welded lap seam for adhered and induction welded systems; Side -laps shall be installed parallel to the direction of the wood trusses for mechanically attached systems over wood decks; Side -laps Duro-Fleece Membrane shall be installed perpendicular to the direction of the steel deck ribs for mechanically attached systems over steel deck. For mechanically fastened systems; Min. 4-inch end lap; Min. Thermal Barrier GAF Versashield Solo 2-inch side lap; Shall be laid perpendicular to the direction of membrane Duro-Last Vapor Barrier Self -adhered to substrate with Duro-Last VB Primer applied at a rate of 0.75-1.25gal/100ft Vapor Barrier Duro-Last Torch Down Vapor Barrier Torched adhered to substrate Duro-Last Fascia Bar Duro-Last Fascia Bar Cover Duro-Last Fascia Duro-Last Snap Coping Duro-Last 2-Piece Metal "T-Edge" Edge Systems Designed by others and installed in accordance with Duro- Last's current, published installation instructions. Duro-Last Drip Edge Duro-Last 2-Piece Compression Edge Duro-Last Vinyl Coated Metal Duro-Last Gravel Stop Duro-Last Versaterm Edge Cellular Lightweight Concrete Celcore S-1 Deck is treated by applying a continuous film with a broom prior to placement of the Celcore lightweight concrete DLR12001.17 FL16039-R17 3of8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX A Component Product Installation Detail Installed over min. 22 ga., 0.5% vented, B-Deck; Slurry coat Celcore MF with HS Rheology Admixture min. 1/8-inch thick; 1-inch thick EPS board (1 Ibs/ft); Min. 2- inch thick top coat; Celcore PVA curing compound applied at Cellular Lightweight rate of 300 ft2/ al Concrete (Cont'd) Elastizell with Zell -Crete Fibers Slur coat min. 1/4-inch thick; Min. 1-inch thick EPS board (1 Ibs/f7, Min. 2-inch top coat Cellular Lightweight Concrete F Slurry coat min. 1/4-inch thick; Min. 1-inch thick EPS board (1 Ibs/ft ); Min. 2-inch top coat Insulation/Cover Board Fastening Patterns Description Fastening Pattern 5 per 4ftx8ftboard m Q o N , o m Q O Max. 6.4ft2 contributory area per fastener 6 per 4ftx8ftboard Q m � N N Max. 6ft2 contributory area per fastener DLR12001.17 FL16039-R17 Page 4 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX A Insulation/Cover Board Fastening Patterns Description Fastening Pattern m 12 per 4 ft x 8 ft board Q � � •� m Q n Max. 2.67ft2 contributory area per fastener m 16 per 4ftx8ftboard m Q I Max. 2.0ft2 contributory area per fastener 0 0 0 0 0 0 18 per 4ftx8ftboard (oj o (D Q Q Q m o L Q O Max. 1.78ft2 contributory area per fastener DLR12001.17 FL16039-R17 Page 5 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX A Insulation/Cover Board Fastening Patterns Description Fastening Pattern 20 per 4 ft x 8 ft board W Max. 1.6ft2 contributory area per fastener m 24 per 4 ft x 8 ft board Q m ' m m Max. 1.33ft2 contributory area per fastener e m 32 per 4ftx8ftboard m Q n m Max. 1.0ft2 contributory area per fastener DLR12001.17 FL16039-R17 Page 6 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC VERSA -FAST Metal plate F r-ax ..tee DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX A DLR12001.17 FL16039-R17 Page 7 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX A Induction Weld Patterns Description Fastening Array Repeated Using the Geometric Grid Shown Below ,a• 0 0 za te• te• 1 per 3.00-ft2 tz o 24' 0 0 za • za —^-- ^I 1 per 4.00-ft2 -}� I 12, 0 a 36' 2a' O O 12' 1 per 6.00-fe O O O O O O DLR12001.17 FL16039-R17 Page 8 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC NOMENCLATURE DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX B The following naming conventions are utilized to specify products in the APPROVED ASSEMBLIES section of this report. Refer to the nomenclature below when deciphering the allowable products for use in the selected roof system. Installation requirements shall be as noted in the APPROVED ASSEMBLIES and INSTALLATION section of this report. Name Definition Approved Insulation One or more layers or combinations of roofing insulation listed in this report or approved under rule 61G20-3, such as gypsum, perlite, polyisocyanurate, polystyrene, or wood fiberboard. Insulation shall be preliminarily secured unless otherwise noted. As Tested Information provided to the report user based on the as tested condition of the roof system CR-20 Duro-Fleece CR-20 Membrane Adhesive; For use with DF or DFP All decks shall be designed by others in accordance with FBC requirements. As Tested deck construction details are described as follows: Concrete Deck I Min. f. = 2,500 psi at 28 days - - _ - - t.. ._...._._..........................._.....- --.. ...._...._........_....._..._..__....__....... _-_-._____._... __.... _............... _..__.... __._.._.................................... _............. _................... -.._....._.__.................... ----._....... _...................... ... _.._..... _................... _... _........................... --................ _......__..__...__... CWF Deck Min. 2.5-inch thick Tectum I cementitious wood fiber panels I Min. 22 ga (Fy = min.33 ksi) Wide Rib Deck (Type WR) conforming to ANSI/SDI-RD1.0 & FBC; 0.5% Vented for LWIC applications only. The following nomenclature is used to further describe the As Tested condition: F<#> Number <#> #12-24 HWH self -drilling screws or equivalent fastener at each flute used to secure the deck —-.._...... _........... -{ to the structural supports: Min. 1/4-inch penetration - G<#> Min. Grade <#> of Steel Deck Steel Deck i ��# .__._.._..-.----------f..----......_......�___...-------_..____._...._.__ __-..,..--.----......__.....__.-___.... 1 Max. span of <#> ft _.._.__.---.--__-. _.._......___-..__.......... P I Min. 5/8-inch diameter puddle welds at each flute used to secure the deck to the structural supports Deck Detail S<#> ( 1/4 "-14 HWH x7/8" self -drilling screws or equivalent fastener secured <#>-inch o.c. along the panel side ~-- laps _ T ...... .................__W 3/4-inch O.D. flat washer used with indicated fastener ........ ._..._.__...._...,..._.__._._..__..................._._...............................-..--..__.._._.-................___..._........................--........................................_.._..-_.._....._....__................_......_..-_.........................._.._....-_............................... _...... —_._.._--------- _..____---......._ _...._........ I HVHZ: Min. 19/32-inch thick APA Span -Rated plywood or wood plank for new construction j The follow! ng_nomenclature is used to further describe_ the As Tested condition: - T<#> _ - Min. <#>-inch thickness of the plywood or wood plank I L<#> Max. span of <#> inches Wood Deck 0.113-<#1>/<#2> _....--..................... .... ._............................. 8d-<#1>/<#2> 0.113-inch x 2-3/8-inch ring shank nails spaced <#1>-inch o.c. at all intermediate supports and spaced <#2> at the perimeter of each board 1..... ........................... ....................__....................._.._........_........................_.............—._...._......-- ...._........_.....- - ._._._...__...._..........._ _............... .._..- --._.........._._...... -- .... __....—__......._.......... 8d ring shank nails spaced <#1>-inch o.c. at all intermediate supports and spaced <#2> at the perimeter of ' each board Hex_<#1>/<#2> 1/4-inch x 2-inch hex wood screws spaced <#1>-inch o.c. at all intermediate supports and spaced <#2> at the perimeter of each board DD Min. 1/4-inch thickness Georgia-Pacific DensDeck DDP Min. 1/4-inch thickness Georgia-Pacific DensDeck Prime with EONICTm Technology DF One ply of any one of the following products: DF50, DF60, or DF80 membranes DLR12001.17 FL16039-R17 Page 1 of 35 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX B Name Definition DFP One ply of any one of the following products: DFP50 or DFP60 membranes DG-BM Duro-Grip Board -Max DG-CR Duro-Grip CR-20 DG-IS Duro-Grip Insta Stik DG-OB Duro-Grip OlyBond 500 DG-TF Duro-Grip Trufast DG-OS Duro-Grip One. Step DL One ply of any one of the following products: DL40, DL50, DL60, or DL80 membranes DL Plates & #15 Fasteners Duro-Last 3" Metal Plates and Duro-Last #15 Extra Heavy Duty Drill Point Fastener for Steel Decks or Wood Decks DL Plates & Fasteners Duro-Last 3" Metal Plates and Duro-Last #14 HD Fastener for Steel Decks or Wood Decks or Duro-Last #14 Concrete Screws for Concrete Decks DT One ply of any one of the following products: DT50, DT60, or DT80 membranes DXF DEXcell FA Glass Mat Roof Board DXC DEXcell Cement Roof Board Duro-Bond Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate with Duro-Last #14 HD Fastener for Wood Decks or Steel Decks or Duro-Last #14 Concrete Screw for Concrete Decks Duro-Bond #15 Duro-Bond Plate 1302 or Duro-Bond PVC IW Plate and Duro-Last #15 Extra Heavy Duty Drill Point Fastener for Steel Decks or Wood Decks Duro-Grip Ribbon adhered with any one of the following products: Duro-Grip Board -Max, Duro-Grip CR-20, Duro-Grip Insta Stik, Duro-Grip OlyBond 500, or Duro-Grip WeatherTite One Step Duro-Guard One or more layers of the following products: Duro-Guard EPS, Duro-Guard EPS FGF, Duro-Guard ISO II -A, Duro-Guard ISO II-G, Duro-Guard ISO II-H, Duro-Guard ISO III -A, Duro-Guard ISO III-H, Duro-Guard ISO IV -A, or Duro-Guard HD Composite Duro-Guard 11 One or more layers of the following products: Duro-Guard EPS, Duro-Guard ISO II -A, Duro-Guard ISO II-G, or Duro-Last Duro-Guard ISO II-H EPS Duro-Guard EPS FGF Duro-Guard EPS Fiberglass Facer (FGF) HD -A Duro-Guard ISO HD -A HD-G Duro-Guard ISO HD-G HD-H Duro-Guard ISO HD-H II A Duro-Guard ISO II -A 11-G Duro-Guard ISO II-G DLR12001.17 FL16039-R17 Page 2 of 35 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply'warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX B Name Definition 11-H Duro-Guard ISO II-H 111 A Duro-Guard ISO III -A 111-G Duro-Guard ISO III-G 111-H Duro-Guard ISO III-H IV -A Duro-Guard ISO IV -A LW/C Poured -in -place; Cellular Lightweight Concrete with encapsulated insulation board MCRF Minimum Characteristic Resistance Force as determined by TAS 105 for the named fastener in the selected assembly MDP Maximum Design Pressure OMG-C Duro-Fleece OMG Canister Membrane Adhesive; For use with DF or DFP Recover Where assemblies are used to recover an existing roof, the existing roof shall consist of only one layer of roofing, i.e. recovering a previously recovered roof is not permitted. Recover roofing shall be conducted in compliance with FBC Section 1511 outside of the HVHZ and FBC Section 1521 within the HVHZ. For mechanically fastened assemblies, the existing roof insulation thickness may be contributory in meeting the minimum insulation thickness requirements for a given roof system. SB IV Duro-Last SB IV Adhesive; For use with DL, or DT SG -SA Duro-Last Solvent -Grip Spray Adhesive; For use with DL, or DT SR USG SECUROCK gypsum -fiber roof board, Min. 1/4-inch thickness TFM Duro-Fleece Trufast Membrane Adhesive; For use with DF or DFP WB I/ Duro-Last WB II Adhesive; For use with DF, DFP, DL, or DT, DLR12001.17 FL16039-R17 Page 3 of 35 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC APPROVED ASSEMBLIES DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes APPENDIX B The following notes shall be observed when using the roof system tables below. 1. MDPs were calculated using a 2:1 margin of safety per FBC Section 1504.9 and 1523.4. MDP shall exceed -45 psf for use in the HVHZ. 2. Refer to LIMITATIONS and NOMENCLATURE sections of this evaluation when using the table(s) below. Items italicized refer to specific nomenclature used in this report. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected roof system. 4. The on -center (o.c.) spacing given is the maximum allowable attachment spacing for the rated roof system. 5. As Tested information for roof deck construction is provided for information only. The addition of the As Tested deck information does not obviate the requirement for rational design of the roof deck and roof deck attachment in accordance with FBC requirements. 6. A vapor barrier may be installed direct to deck prior to installing the roof assembly components for following assembly types: C-M-#, C-W-#, G-M-#, LC- M-#, LS-M-#, S-M-#, S-W-#, W-M-#, and W-W-#. Roof System Numbers and Definitions C-A-# Assemblies with All Layers Adhered over Concrete Deck (New or Existing) C-AM-# Assemblies with Adhered Membranes over Insulated Concrete Deck (New, Existing, or Recover) C-M-# Mechanically Fastened Assemblies over Concrete Deck (New, Existing, or Recover) C-W-# Induction Welded Assemblies over Concrete Deck (New, Exiting, or Recover) CW-A-# Assemblies with All Layers Adhered over CWF Deck (New or Existing) CW-M-# Mechanically Fastened Assemblies over CWF Deck (New, Existing, or Recover) G-A-# Assemblies with All Layers Adhered over Gypsum Deck (New or Existing) G-M-# Mechanically Fastened Assemblies over Poured Gypsum Deck (New or Existing) LC -A-# Lightweight Concrete Assemblies with All Layers Adhered over Concrete Deck (New or Existing) LC-M-# Mechanically Attached Lightweight Insulating Concrete Assemblies over Concrete Deck (New or Existing) LS-A-# Lightweight Concrete Assemblies with All Layers Adhered over Steel Deck (New or Existing) LS-M- # Mechanically Attached Lightweight Insulating Concrete Assemblies over Steel Deck (New or Existing) R-A-# Recover Assemblies with All Layers Adhered R-M-# Mechanically Fastened Recover Assemblies R-W-# Induction Welded Recover Assemblies S-A-# Assemblies with All Layers Adhered over Steel Deck (New or Existing) S-AM-# Assemblies with Adhered Assemblies over Steel Deck (New, Existing or Recover) S-M-# Mechanically Fastened Assemblies over Steel Deck (New, Existing, or Recover) S-W_# Induction Welded Assemblies over Steel Deck (New, Existing, or Recover) W-A-# Assemblies with All Layers Adhered over Wood Deck (New or Existing) W-M-# Mechanically Fastened Assemblies over Wood Deck (New or Existing, or Recover) W-W# Induction Welded Assemblies over Wood Deck (New, Existing, and Recover) DLR12001.17 FL16039-R17 Page 4 of 35 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK DURO-LAST ROOFING, INC. PVC Single -Ply Roofing Membranes 6 TECHNICAL SERVICES, LLC APPENDIX B Mechanically Fastened Assemblies over Steel Deck New, Existing, or Recover) System Deck Base Base Insulation Top Insulation Top Insulation Membrane Attachment MDP No. Detail Insulation Attachment Attacment (psf) Duro-Last #15 EHD Drill Point Fastener G80, Min. 1.5-inch Preliminarilywith Duro-Last 3-inch Metal Plates -52.5 S-M-14 L6, PIN, Approved secured _ _ DL fastened 12-inch o.c. along the 6-inch wide (Lim. 7) S24 Insulation tabs spaced 57-inches o.c. Tab Sealer 4725 applied at 60 ftz/gal. Duro-Last #15 EHD Drill Point Fastener G80, Min. 1.5-inch Preliminarily t with Duro-Last 3-inch Metal Plates -52.5 S-M-15 L6, PIN, Approved secured - - DL fastened 6-inch o.c. along the 6-inch wide (Lim. 7) S24 Insulation tabs spaced 84-inches o.c. Tab Sealer 4725 applied at 60 ftZ/gal. G80, Duro-Last #15 EHD Drill Point Fastener L6, Min. 1.5-inch Preliminarily with Duro-Last Cleat Plates fastened 12- -52.5 S-M-16 F1W Approved secured - - DL inch o.c. along the 6-inch wide tabs (Lim. 7) Insulation spaced 84-inches o.c. Tab. Sealer 4725 a li a 0 / G80, L6, P m. -inch A proved reliminari , O DL Duro- ast EHD Dn I Point as ener with Duro-Last Cleat Plates Fastened 6 -60 S24 Insulation secured inch o.c. along the 3-inch wide tabs Lim. 7 s aced 8_4zin,ches c. G33, Min. 0.5-inch Preliminarily and Duro-Last Poly -Plates or Cleat Plates -60 S-M-18 L6, PW, Approved secured - - DT fastened 6-inch o.c. within 6-inch wide laps (Lim. 7) S24 Insulation spaced 54-inch o.c.; fastener centered 1.25-inches from edge of tab Duro-Last #15 EHD Drill Point Fastener G33, Min. 0.5-inch Preliminarily and Duro-Last Poly -Plates or Cleat Plates -67.5 S-M-19 L6, F1, Approved secured - - DT fastened 6-inch o.c. within 6-inch wide laps (Lim. 7) S24 Insulation spaced 54-inch o.c.; fastener centered 1.25-inches from edge of tab Duro-Last #15 EHD Drill Point Fastener G80, Min. 1.5-inch Preliminarily with Duro-Last Batten Bar fastened 6-inch -67.5 S-M-20 L5, F1, Approved secured _ DL o.c. within center of 3-inch wide tabs (Lim. 7) S24 Insulation spaced 60-inches o.c. Tab Sealer 4725 applied at 60 ft2/ al. G80, Duro-Last #15 EHD Drill Point Fastener Min. 1.5-inch Preliminarily with Duro-Last Cleat Plates fastened 12- - S-M-21 F1 W,L6' Approved secured _ _ DL inch o.c. along the 6-inch wide tabs .5 m (Lim. 7) S24 S24 Insulation spaced 57-inches o.c. Tab Sealer 4725 applied at 30 ft2/ al. DLR12001.17 FL16039-R17 Page 29 of 35 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.