Loading...
HomeMy WebLinkAboutNOA- FRENCH DOORS MIAM 0- E MIAMI—DADE COUNTY,FLORIDA Em PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 TICS OF ACCEPTANCE (NOA) www.miamidade.2ov/economy PGT Industries,Inc. 1070 Technology Drive, Nokomis,Fl.34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami—Dade County RER—Product Control Section to be used in Miami—Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami—Dade County Product Control Section (In Miami—Dade County) and/ or the AHJ (in areas other than Miami—Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami—Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series"FD-750"Outswing Aluminum French Door w/Sidelites—L.M.I. APPROVAL DOCUMENT: Drawing No. 8000-11 Rev H, titled "Alum. French Door & Side Lites, Impact", sheets 1 through 12 of 12, dated 12/23/04 and last revised on 04/20/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P. E., bearing the Miami—Dade County Product Control Section Revision stamp with the Notice of Acceptance number and Expiration date by the Miami—Dade County Product Control Section. ISSILE IMPACTRATING: Large and Small Missile Impact Resistant Limitations: 1. See sheet 3 for Design Pressures (DP) VS sizes and glass types for doors and Sidelites and overhang/sill options in sheet 1. When doors are assembled with sidelites, lower design pressures from door or sidelite shall control 2. See glass options in sheet 1 &2 and spacer options for insulated glass in sheet 9. 3. See installation anchoring details in sheets 10, 11 and 12. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,model/series, and following statement: "Miami—Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami—Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official This NOA revises NOA No. 19-1126.08 and consists of this page 1 and evidence pages E—1,E-2,E-3,E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda,P.E. NOA No.20-0427.03 MIAMhDADE COUNTY Expiration Date: February 24,2025 Approval Date: September 17,2020 Pagel 1 PGT Industries , Inc. NOTICE OF ACCEPTANCE . EVIDENCE SUBMITTED 1 . Evidence submitted under previous approvals A. DRAWINGS 1 . Manufacturer' s die drawings and sections . 2 . Drawing No . 8000-11 , titled "Alum . French Door & Side Lites , Impact", sheets 1 through 12 of 12 , dated 12/23 /04 , with revision "E " dated 10/ 12/ 11 , prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P . E . . TESTS 1 . Test reports on: 1 ) Air Infiltration Test, per FBC , TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC , TAS 202-94 3 ) Water Resistance Test, per FBC , TAS 202-94 4) Forced Entry Test, per FBC 2411 . 3 . 2 . 1 , and TAS 202-94 along with marked—up drawings and installation diagram of an aluminum sliding glass door using a low sill threshold, glazed with 7/ 16 " laminated glass , prepared by Fenestration Testing Laboratory , Inc . , Test Report No . FTL 5941 , dated 05 /20/09 , signed and sealed by Julio E . Gonzalez, P . E . (Submitted under previous NOA No. 09-1028. 10) along with marked—up drawings and installation diagram of an aluminum doors of OXXO configuration, prepared by Fenestration Testing Laboratory , Inc . , Test Report No . FTL-4921 , dated 07/ 17/06 , signed and sealed by Edmundo J . Largaespada, P . E . (Submitted under previous NOA No. 05-0419. 03) 2 . Test reports on : 1 ) Air Infiltration Test, per FBC , TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC , TAS 202-94 3 ) Water Resistance Test, per FBC , TAS 202-94 4) Forced Entry Test, per FBC 2411 . 3 . 2 . 1 . and TAS 202-94 along with marked—up drawings and installation diagram of an aluminum doors of OXXO configuration, prepared by Fenestration Testing Laboratory , Inc . , Test Reports No . ' s FTL-4528 , dated 02/ 14/05 ) FTL-4315 , dated 09/ 13 /04 , both signed and sealed by Edmundo J. Largaespada, P . E . (Submitted under previous NOA No. 05-0419. 03) 3 . Test reports on : 1 ) Large Missile Impact Test per FBC , TAS 201 -94 2) Cyclic Wind Pressure Loading per FBC , TAS 203 -94 along with marked—up drawings and installation diagram of an aluminum doors of XXXO configuration, prepared by Fenestration Testing Laboratory, Inc . , Test Reports No . ' s FTL-4529 , dated 02/ 14/051 FTL-4530 , dated 02/ 14/05 , FTL-4311 , dated 09/01 /04 , all signed and sealed by Edmundo J. Largaespada, P . E . (Subitted under previous NOA No. 05-0419. 03) 4. Test reports on: 1 ) Uniform Static Air Pressure Test, Loading per FBC , TAS 202-94 2) Large Missile Impact Test per FBC , TAS 201 -94 3 ) Cyclic Wind Pressure Loading per FBC , TAS 203 -94 along with marked—up drawings and installation diagram of an aluminum outswing French door, prepared by Fenestration Testing Laboratory, Inc . , Test Report No . FTL-4312 , dated 09/ 13 /04 , signed and sealed by Edmundo J . Largaespada, P . E . (Subitted under previous NOA No. 05-0419. 03) C . CALCULATIONS 1 . Anchor verification calculations and structural analysis , complying with FBC 2010 and FBC 20149 5th Edition , prepared by manufacturer, dated 10/ 11 / 11 , signed and sealed by A. Lynn Miller, P . E . 2 . Glazing complies with ASTM E1300-04/ 09 Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0427. 03 Expiration Date: February 24, 2025 Approval Date : September 17, 2020 E - 1 PGT Industries NOTICE OF ACCEPTANCE : EVIDENCE SUBMITTED D . QUALITY ASSURANCE 1 . Miami—Dade Department of Regulatory and Economic Resources (RER) . E . MATERIAL CERTIFICATIONS 1 . Notice of Acceptance No . 144916. 10 issued to Kuraray America, Inc. for their "Kuraray PVB Glass Interlayer" dated 02/ 19/ 15 , expiring on 12/ 11 / 16 . 2 . Notice of Acceptance No . 14-0423 . 15 issued to Eastman Chemical Company (MA) for their " Saflex CP — Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 06/ 19/ 14 , expiring on 12/ 11 / 18 . 3 . Notice of Acceptance No . 14-0423 . 16 issued to Eastman Chemical Company ( A) for their " Saflex HP Clear or Color Glass Interlayers" dated 06/ 19/ 14 , expiring on 04/ 14/ 18 . F. STATEMENTS 1 . Statement letter of conformance to FBC-2010 and complying with FBC 5th Edition (2014) , issued by manufacturer, dated 11 /06/ 14 , signed and sealed by A . Lynn Miller, P . E . 2 . Statement letter of no financial interest, issued by manufacturer, dated 11 /06/ 14 , signed and sealed by A . Lynn Miller, P . E . 3 . Department of State Certification of PGT INDUSTRIES , INC . as a for profit corporation, active and organized under the laws of the State of Florida, dated 01 /27/ 15 and filed by Ken Detzner, Secretary of State . 4 . Notification of Successor Engineer for manufacturer ' s NOA document per Section 61G15- 27. 001 of the Florida Administrative Code , notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated 10/07/ 11 , signed and sealed by A . Lynn Miller, P . E . 5 . Proposal No . 08-1891 issued by Product Control, dtd 01 /26/09 , signed by Ishaq Chanda, P . E . G. OTHERS 1 . Notice of Acceptance No . 114013 .24 , issued to PGT Industries for their Series "FD-750" Outswing Aluminum French Door w/Sidelites — L . M . I . , expiring on 02/24/ 15 . 2 . Evidence submitted under previous approvals A . DRAWINGS 1 . Drawing No . 8000-11 , titled "Alum . French Door & Side Lites , Impact" , sheets 1 through 12 of 12 , dated 12/23 /04 , with revision "G" dated 04/ 10/ 17 , prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P . E . Be TESTS 1 . Reference Test report on 1 ) Uniform Static Air Pressure Test, per FBC , TAS 202 - 94 2) Large Missile Impact Test per FBC , TAS 201 - 94 3 ) Cyclic Wind Pressure Loading per FBC , TAS 203 - 94 Along with marked-up drawings and installation diagram of Aluminum Sliding Glass Doors (w/ PS , Super, Cardinal & Duraseal Spacers) , prepared by Fenestration Testing Laboratory , Inc . , Test Reports No (s) FTL-8717, FTL-8970 and FTL-8968 , dated 02/ 15/ 16 , 06/07/ 16 and 06/20/ 16 , all signed & sealed by Idalmis Ortega, P . E . (Submitted under previous NOA No. 164629. 16) Ishaq I. Chanda, P. E . Product Control Unit Supervisor NOA No. 20-0427. 03 Expiration Date : February 24, 2025 Approval Date : September 17, 2020 E - 2 PGT Industries , Inc. NOTICE OF ACCEPTANCE : EVIDENCE SUBMITTED Co CALCULATIONS 1 . Anchor verification calculations and structural analysis, complying with FBC 51h Edition (2014) and FBC 6th Edition (2017) , prepared by manufacturer, dated 11 /22/ 17 , signed and sealed by A . Lynn Miller, P . E . D . QUALITY ASSURANCE 1 . Miami—Dade Department of Regulatory and Economic Resources (RER) . E . MATERIAL CERTIFICATIONS 1 . Notice of Acceptance No . 164117. 01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear, and Color PVB Glass Interlayers " dated 01 / 19/ 17 , expiring on 07/08/ 19 . 2 . Notice of Acceptance No . 17-0712 . 03 issued to Eastman Chemical Company (MA) for their " Saflex CP — Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/ 17 , expiring on 12/ 11 / 18 . 3 . Notice of Acceptance No . 17-0712 . 04 issued to Eastman Chemical Company ( A) for their " Saflex HP Clear or Color Glass Interlayers " dated 09/07/ 17 , expiring on 04/ 14/ 18 . F . STATEMENTS 1 . Statement letter of conformance with FBC 5th Edition (2014) and FBC 6th Edition (2017) , issued by manufacturer, dated 08/ 16/ 17 , signed and sealed by A . Lynn Miller, P . E . 2 . Test proposal No . 16 -0152 dated 03 /09/ 16 approved by RER. G . OTHERS 1 . Notice of Acceptance No . 16-0629 . 16 , issued to PGT Industries for their Series "FD-750 " Outswing Aluminum French Door w/Sidelites — L . M . I . , expiring on 02/24/20 . 3 . Evidence submitted under previous approvals A. DRAWINGS 1 . Drawing No . 800041 , titled "Alum . French Door & Side Lites , Impact", sheets 1 through 12 of 12 , dated 12/23 /04 , with revision "F" dated 05/05 / 16 , prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P . E . Bo TESTS (Submitted under previous approvals) 1 . None Co CALCULATIONS (Submitted under previous NOA No. 144117. 05) 1 . None . D . QUALITY ASSURANCE - 1 . Miami—Dade Department of Regulatory and Economic Resources (RER) . E . MATERIAL CERTIFICATIONS 1 . None . F. STATEMENTS 1 . None . , a Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0427. 03 Expiration Date : February 24, 2025 Approval Date : September 17, 2020 E - 3 PGT Industries NOTICE OF ACCEPTANCE : EVIDENCE SUBMITTED G. OTHERS 1 . Notice of Acceptance No . 144117. 05 , issued to PGT Industries for their Series "FD-750" Outswing Aluminum French Door w/Sidelites — L . M. I . , expiring on 02/24/20 . 4 . Evidence submitted under previous approval A. DRAWINGS 1 . Drawing No . 8000-11 Rev G , titled "Alum . French Door & Side Lites , Impact", sheets 1 through 12 of 12 , dated 12/23 /04 and last revised on 11 /22/2019 , prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P . E . B . TESTS 1 . None . Co CALCULATIONS (submitted under file # 17-0504.04) 1 . None . 2 . Glazing complies with ASTME4300- 02 , -04 & - 09 . . QUALITY ASSURANCE 1 . Miami Dade Department of Regulatory and Economic Resources (RER) . E . MATERIAL CERTIFICATIONS 1 . Notice of Acceptance No . 19-0305 . 02 issued to Kuraray America, Inc. for their " Trosifol® Ultraclear, Clear, and Color PVB Glass Interlayers" , expiring on 07/08/24 . 2 . Notice of Acceptance No . 1 &0301 . 06 issued to Eastman Chemical Company (MA) for their " Saflex CP — Saflex and Saflex HP Composite Glass Interlayers with PET Core" expiring on 12/ 11 /230 3 . Notice of Acceptance No . 17-0712 . 05 issued to Eastman Chemical Company (MA) for their " Saflex HP Clear or Color Glass Interlayers ", expiring on 05/21 /21 . F. STATEMENTS 1 . Statement letter of conformance to FBC 2017 (6th Edition) , issued by manufacturer, dated 11 /22/ 19, signed and sealed by Lynn Miller, P . E . G . OTHER 1 . This NOA renews # 17-0504. 04. 5 . New Evidence submitted A. DRAWINGS 1 . Drawing No . 8000-11 Rev H, titled "Alum . French Door & Side Lites , Impact" , sheets 1 through 12 of 12 , dated 12/23 /04 and last revised on 04/20/20 , prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P . E . Ishaq I. Chanda, P. E. Product Control Unit Supervisor NOA No. 20-0427. 03 Expiration Date : February 24, 2025 Approval Date : September 17, 2020 E - 4 PGT Industries , Inc. NOTICE OF ACCEPTANCE . EVIDENCE SUBMITTED B . TESTS 1 . Test reports on: 1 ) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3 ) Water Resistance Test, per FBC , TAS 202-94 4) Large Missile Impact Test per FBC , TAS 201 -94 5 ) Cyclic Wind Pressure Loading per FBC , TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202 -94 along with marked-up drawings and installation diagram of all PGT Industries , Inc . , representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones , per Proposal # 19- 1155TP , prepared by Fenestration Testing Laboratory , Inc . , Test Reports No . : PGT Industries , Inc. test specimens . FTL4897, PGT PW5520 PVC Fixed Window (unit 6 in proposal) , dated 09/03 / 14 FTL-20 -2107. 1 , PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20 -2107. 2 , PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20 -2107.3 , PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107. 4 , PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/ 13 /20 and signed and sealed by Idalmis Ortega, P . E. D . CALCULATIONS 1 . Anchor verification calculations and structural analysis , complying with FBC 2020 , 711 Edition , prepared by manufacturer, dated 04/20/20 , signed and sealed by A . Lynn Miller, P . E . 2 . Glazing complies with ASTM E1300-04, - 09 , - 12 and- 16 . D . QUALITY ASSURANCE 1 . Miami Dade Department of Regulatory and Economic Resources (RER) . E. MATERIAL CERTIFICATIONS 1 . Notice of Acceptance No . 19 -0305. 02 issued to Kuraray America, Inc. for their " Trosifol® Ultraclear, Clear, and Color PVB Glass Interlayers " , expiring on 07/08/24 . 2 . Notice of Acceptance No . 18 -0301 . 06 issued to Eastman Chemical Company (MA) for their " Saflex CP — Saflex and Saflex HP Composite Glass Interlayers with PET Core" expiring on 12/ 11 /230 3 . Notice of Acceptance No . 17-0712 . 05 issued to Eastman Chemical Company (MA) for their "Saflex HP Clear or Color Glass Interlayers" , expiring on 05 /21 /21 . F . STATEMENTS 1 . Statement letter of conformance to FBC 2017 (6th Edition) , issued by manufacturer, dated 11 /22/ 19 , signed and sealed by Lynn Miller, P . E . G. OTHER 1 . This NOA revises NOA # 194126.08 and updates to FBC 2020 , expiring 02/24/25 . 2 . Extrusion DWG # 8058 Rev A. 3 . RER Test proposals # 194155 dated 01 / 10/20 approved by Ishaq I . Ch nda, P . E . k i Ish , q 1. Chanda, P. E. Product Control Unit Supervisor NOA No. 2M427. 03 Expiration Date : February 24, 2025 Approval Date : September 17, 2020 E - 5 SERIES 750 OUTSWING , IMPACT RESISTANT FRENCH DOOR AND SIDE LITE DESIGN PRESSURE RATING IMPACT RATING SEE TABLE 1 ON SHEET 3 RATED FOR LARGE & SMALL 1 . GLAZING OPTIONS : MISSILE IMPACT RESISTANCE A. 7/ 16" LAM [ CONSISTING OF ( 1 ) LITE OF 3/16" ANNEALED GLASS AND ( 1 ) LITE OF 3/16" HEAT TABLE A: STRENGTHENED GLASS WITH AN . 090" PVB INTERLAYER Min , B . 7/16" LAMI CONSISTING OF (2) LITES OF 3/16" HEAT STRENGTHENED GLASS WITH AN . 090" PVB Anchor Frame Min , Edge Embedment or INTERLAYER Group Anchor Type Member Substrate Distance Metal C. 7/16" LAMI CONSISTING OF ( 1 ) LITE OF 3/16" ANNEALED GLASS AND ( 1 ) LITE OF 3/16" HEAT Thickness STRENGTHENED GLASS WITH AN . 075" INTERLAYER . All Southern Pine (SG = 0 .55) 9/ 16" 1 -3/8" D . 7/16" LAMI CONSISTING OF (2) LITES OF 3/ 16" HEAT STRENGTHENED GLASS WITH AN . 075" #12 SMS (steel , 18-8 S . S . or All 6063-T5 Aluminum 3/8" 118" INTERLAYER . A 410 S . S . ) All Steel , A36 3/8" 0. 060" E . 7/8" LAMI I . G . CONSISTING OF ( 1 ) LITE OF 3/16" TEMPERED GLASS OUTSIDE , 1 /4" AIR SPACE AND All Steel Stud , Al003 Gr. 33 318" 0. 0451 " (18 Ga . ) ( 1 ) 7/ 16" LAMI GLASS ASSEMBLY INSIDE (3/16 " A, . 090" PVB , 3/16" HS) , All Concrete (min . 2 . 85 ksi ) 2" 1 -3/4" F . 7/8" LAMI I . G . CONSISTING OF ( 1 ) LITE OF 3/16" TEMPERED GLASS OUTSIDE , 1 /4" AIR SPACE AND 1 /4" Elco UltraCon® Jamb Hollow Block (ASTM C90) 2" 1 -1 /4" ( 1 ) 7/16" LAMI GLASS ASSEMBLY INSIDE (3/16" HS , . 090" PVB, 3/16" HS) . B All Concrete (min . 3 ksi) 2" 1 -3/4" G . 7/8" LAMI I . G . CONSISTING .OF ( 1 ) LITE OF 3/ 16" TEMPERED GLASS OUTSIDE , 1 /4" AIR SPACE AND 1 !4" DeWalt UltraCon+® Jamb Hollow Block (ASTM C90) 2" 1 -1l4" (1 ) 7116" LAMI GLASS ASSEMBLY INSIDE (3/16 " A, . 075" INTERLAYER, 3/ 16" HS) , ]JambLHollow ncrete (min . 3. 35 ksi ) 1 -3/4" 1 -3l4" H . 7/8" LAMI I . G . CONSISTING OF ( 1 ) LITE OF 3/16" TEMPERED GLASS OUTSIDE , 1 /4" AIR. SPACE AND C 1 /4" 410 SS Elco/DeWalt Block (ASTM C90) 1 -3/4" 1A14"( 1 ) 7/ 16" LAMI GLASS ASSEMBLY INSIDE (3116" HS , . 075" INTERLAYER, 3/ 16" HS) . CreteFlex® ( )thern Pine SG = 0. 55 1 " 1 3/8" 2 . DESIGN PRESSURES : TABLE I . SHEET 3 . 1 ) WHERE SUBSTRATE CONDITIONS REQUIRE ANCHORAGE FROM MORE THAN ONE OF THE ANCHOR GROUPS A. NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM El300 . ABOVE , CHOOSE THE ANCHOR GROUP OF THE LOWEST LETTER FOR ALL TABLES IN THIS APPROVAL, B . POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS TABLES ASTM El 300 . 2) ALL ANCHOR HEAD TYPES ARE BLE. 3) MIN , OF 3 THREADS BEYOND METALTAL SU SUBSTRATE. C . DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN , ASD. 4) SEE ANCHOR/SUBSTRATE MATERIAL PROPERTIES ON SHEET 7 FOR Fy & Fu. 3 . CONFIGURATIONS : X , O , XX , XO , OX, XXX, XXO , OXX , OXO , XXXX, XXXO , OXXX , OR OXXO WHERE O REPRESENTS EITHER THE NARROW JAMB OR FULL JAMB SIDE LITE . ANY TWO ADJACENT X UNITS CAN BE EITHER TWO SINGLE , X DOORS OR A DOUBLE , XX DOOR' BOTH USING EITHER THE STANDARD OR THE LOW-RISE SILL. THE FRENCH DOOR ASSEMBLY BEAM IS USED TO ASSEMBLE X , XX, AND O UNITS TO MAKE THE ABOVE CONFIGURATIONS . 4 , ANCHORAGE : THE 33 1 /3 % STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT, FOR ANCHORAGE REQUIREMENTS SEE SHEETS 10 THRU 12 . 5 . SHUTTERS ARE NOT REQUIRED , 6 . SEALANT : INSTALLATION SCREWS , FRAME AND PANEL CORNERS SEALED WITH CLEAR COLORED SEALANT. VERTICAL ASSEMBLY BEAM SEAM -SEALED ON THE INTERIOR AND EXTERIOR WITH CONTRACTOR'S SEALANT, 7 . REFERENCES : TEST REPORTS : FTL4311 , FTL4312, FTL4315 , FTL4527 , FTL4528 , FTL4529 , FTL4530 , FTL-4921 AND FTL-5941 . ANSI/AF & PA NDS FOR WOOD CONSTRUCTION ADM ALUMINUM DESIGN MANUAL 8 , THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE , INCLUDING THE L s e "i HIGH VELOCITY HURRICANE ZONE (HVHZ) . NuMiagcoda Acceptance No Elm to GENERAL NOTES . . . . . . . . . . . . 1 � CONFIGURATIONS . . . . . . . . . . . 1WAO " GLAZING DETAILS . . . . . . . . . . . 2 CODES / STANDARDS USED: DESIGN PRESSURES. . . . . . 3 • 2020 FLORIDA BUILDING CODE (FBC), 7TH EDITION , C) \N •LY �t''� i ELEVATIONS " . . . . . . . . . . . . . . . " .. .. . . . . . . . . . . . . . . . 4 � , • 2017 FLORIDA BUILDING CODE (FBC ) , 6TH EDITION �r , • ULP� c4 • ASTM E1300 09 VERT. SECTIONS . , . . . . . . . : . . . 5 • ANSI/AF&PA NDS-2018 FOR WOOD CONSTRUCTION HORIZ. SECTIONS . . . . . . . . . . . 6 y • ALUMINUM DESIGN MANUAL, ADM-2015 PARTS LIST. 7 ;,> No , 58705 • AISI S100- 16 EXTRUSIONS . . . . . . . . . . . . . . . . . . . 8-9 • AISC 360-16 ANCHORAGE . . . . . . . . . . . . . . . . . . . . 10A2 �0 E WATE j "PVB" = .090" TROSIFOL PVB BY KURARAY AMERICA, INC. ORQ C(�\ 090" SAFLEXIKEEPSAFE MAXIMUM PVB BY EASTMAN CHEMICAL CO. 107o TECHNOLOGY DRIVE � N VENICE, FL M275 GENERAL NOTES AND DRAWING A . 075" SAFLEX CP WITH PET CORE INTERLAYER BY EASTMAN CHEMICAL CO. (941) 4804600 TOW � / ; Randsy: o� I Revbb= I REGISTR4770N #29296 AL U . FRENCH DOOR & SIDE LITES, IMPACT AGK 04117120 H UPDATED TO FBC2020, REV'DANCHOR TABLE. sc sn� lDrmftW ate: A. LYNN MILLER, P . E . DramW. Darn: cx, a Dom: F.K 12123104 L. T. 418105 FD750 FUL 1 a 92 8000- 11 H FL P . E .# 58705 7/16 " NOM , 7/16" NOM , 3/16" ANNEALED OR HEAT STRENGTHENED GLASS 3/16" ANNEALED OR HEAT STRENGTHENED GLASS 090" PVB INTERLAYER , 075" SAFLEX CP WITH PET CORE INTERLAYER 3/16" HEAT STRENGTHENED GLASS 3/16" HEAT STRENGTHENED GLASS 91 OR 92 93 OR 94 109 109 90 9 ® 107 107 I 105 5/8" GLASS 105 5/8" GLASS BITE BITE EXTERIOR INTERIOR EXTERIOR INTERIOR GLAZING DETAIL SETTING BLOCK GLAZING DETAIL SETTING BLOCK 7/ 16 " LAMI GLASS W/ PVB INTERLAYER 7/ 16 " LAMI GLASS W/ . 075 " SAFLEX CP WITH PET CORE INTERLAYER 7/8" NOM . 7/8" NOM . 3/ 16" TEMPERED GLASS 3/16" TEMPERED GLASS AIR SPACE AIR SPACE 3/ 16" ANNEALED OR HEAT 3/16" ANNEALED OR HEAT STRENGTHENED GLASS STRENGTHENED GLASS . 090" PVB INTERLAYER , 075 " SAFLEX CP WITH PET CORE INTERLAYER 3/ 16" HEAT STRENGTHENED GLASS 3116" HEAT STRENGTHENED GLASS 95 OR 96 97 OR 98 109 109 108 90 108 90 emp"fig mukting C 105 5/8" GLASS 105 5/8" GLASS Acceptance No _ __ � ' -" � BITE BITE Expimim q $ it ¢ mge L �3L�xTM w 2 0 5„ \ 1 ` � , t4itt / / Irr EXTERIOR INTERIOR EXTERIOR INTERIOR >i ��``i' LY: rtilF( SETTING BLOCK SETTING BLOCK _.Sr05 GLAZING DETAIL GLAZING DET tvo . 70AIL =� 7/8 LAMI I . G . GLASS W/ PVB [ NTERLAYER 7/8 " LAMI I . G . GLASS W/ . 075 " SAFLEX CP - XiIATt WITH PET CORE INTERLAYER `� "PVB" _ .090" TROSIFOL PVB BY KURARAY AMERICA, INC . OR ,090" SAFLEX/KEEPSAFE MAXIMUM PVB BY EASTMAN CHEMICAL CO. i0707ECHNOLOGYDRIVE 075" SAFLEX CP WITH PET CORE INTERLAYER BY EASTMAN CHEMICAL CO. N (� 4804600 QZ FL 75 G l G DETAILS f�/0 j JAL �v r � ! ltlilli � i Trk Revad Wo a9W REGIS AnON #29M ALUM. FRENCH COO & SIDE LITES, IMPACT AGK 04117120 H NO CHANGES THIS SHEET s Sneer D, wft �. Rer A. LYNN MILLER , P . E . am„ Sr. Dates [ DaBa FwK 12123104 L. T. 418/05 FD750 F(!L 2 of 12 8000- 91 H FL P . E.# 58705 Table 1 . Maximum Design Pressures (psfl OVERHANG LENGTH Allowed Height (in) OVERHANG of Configuration Width (in) Glace s ® o HEIGHT o Types, 79 3/4 (6 ) 3 3/4 (7 ) 87 3/4®1 91 314 95 3/ 4.e (8 ) A , E + 70 . 0 -80 . 0 + 70 . 0 -80 . 0 + 70 . 0 -80 . 0 + 70 . 0 -80 . 0 + 70 . 0 -80 . 0 X 37" (3) NOTES: French C , G + 100 . 0 - 100 . 0 + 100 . 0 -100 . 0 + 100 . 0 - 100 . 0 + 100 . 0 A 00 . 0 + 100 . 0 -100 . 0 1 . IF USING THE OPTIONAL LOW RISE SILL Door A , E + 70 . 0 -80. 0 + 70. 0 -80 . 0 + 70. 0 -80 . 0 + 70. 0 -80 . 0 + 70 . 0 -80 . 0 (PART 10 , SHEET 8 OF 12) , THE XX 71 3/4" (60) 1 1 1 1 1 1 1 1 1 1 OVERHANG LENGTH MUST BE GREATER C , G + 100 . 0 - 100 . 0 + 100 . 0 - 100 . 0 + 100. 0 -100 . 0 + 100 . 0 - 100 . 0 + 100. 0 A00 . 0 THAN OR EQUAL TO THE OVERHANG HEIGHT (SEE DIAGRAM) . IF NOT, THE MAXIMUM POSITIVE (+) DESIGN Full A , E + 70 . 0 -80 . 0 + 70 . 0 -80 . 0 + 70 . 0 -80 . 0 + 70 . 0 -80 . 0 + 70 . 0 -80 . 0 PRESSURE IS LIMITED TO +50. 0 PSF FOR Jamb 36 11 / 16" ALL STYLES AND SIZES OF THE DOOR C , G + 100 . 0 A00 . 0 + 100 . 0 - 100. 0 + 100 . 0 - 100. 0 + 100. 0 A00 . 0 + 100 . 0 - 100 . 0 AND ANY ADJOINING SIDELITES. (REF . FTL-5941 ) 30 11 / 16 C , G + 100. 0 - 100 . 0 + 100 . 0 A00 . 0 + 100 . 0 A00 . 0 + 100. 0 - 100 . 0 + 100 . 0 - 100 . 0 2_ FOR COMBINED UNITS , THE LOWEST DESIGN PRESSURE OF THE SIDELITE AND Sidelite 33 11 / 16 C , G + 100 . 0 A 00 . 0 + 100 . 0 - 100 . 0 + 100. 0 - 100 . 0 + 100 . 0 - 100 . 0 + 97 . 4 -97 . 4 THE DOOR GOVERNS THE OVERALL Narrow I I ASSEMBLY DESIGN PRESSURE , Jamb A , B , E , F + 70 . 0P�80aO + 70. 0 -80 . 0 + 70 . 0 -80 . 0 + 70 . 0 -80 . 0 +70 . 0 -80 . 0 3611 / 16if C , G + 100. 0 + 99 . 9 -99 . 9 + 95 . 3 -95 . 3 + 91 .4 -91 . 4 + 87 . 9 -87 . 9 D , H + 100 . 0 + 100 . 0 A00 . 0 + 100. 0 -100 . 0 + 100 . 0 - 100 . 0 + 100 . 0 -100 . 0 Table 1 a . Glass Type and Test Report Dumber A - 7/ 16" LAMI (3/ 16"A , . 090 PVB , 3/ 16" HS ) FTL431. 1 , 4312 , 4315 B - 7/ 16" LAMI (3/ 16" HS , . 090 PVB , 3/ 16" HS ) UPGRADE FTL-4311 , 4312 , 4315 C - 7/ 16" LAMI (3/ 16"A , . 075 VANCEVA , 3/ 16" HS ) FTL45271 4528 , 4529 , 4530 D - 7116" LAMI (3/ 16" HS ,.. 075 VANCEVA , 3/ 16" HS) UPGRADE FTL4527 , 4528 , 45293 4530 E - 7/8" LAMI I . G . (3/ 16171 1 /4" AIR SPACE , 3/ 16" A , . 090 PVB , 3/ 16" HS ) FTL-43111 43121 4315 as P F - 7/8" LAMI I . G . (3/ 1672 1 /4" AIR SPACE , 3/ 16" HS , . 090 PVB , 3/ 16" HS) UPGRADE FTL4311 ; 43121 4315 Acceptance fqcft ` G - 7/8" LAMI I . G. (3/ 16"T3 1 /4" AIR SPACE , 3/ 16"A, . 075 VANCEVA , 3/ 16" HS) FTL4527 , 4528 , 4529 , 4530 s ra H - 7/8" LAMI I . G . (311671 1 /4" AIR SPACE , 3/ 16" HS , . 075 VANCEVA, 3/ 16 " HS) UPGRADE FTL4527 , 4528 , 4529 , 4530 p�Y LYNN � '% _ No. 58705 O� 2TATE F (� 1070 TECHNOLOGYDRIVE ! ` FL CRt d � . • ` N VEWI CE, FL 75 DESIGNPRESSURES l f GP AL � � r E�G� REGISMMONMAM � ALUM. FRENCH DOOR & SIDE LITES, IMPACT r r l r r 11 � � ` ` AGK 04/17/20 H NO CHANGES THISSHEEffAx �, A. LYNN MILLER , P .E. DFMM er. o F.IC IZ23/04 LT. 4/8W FD750 NTS 3 of 12 800041 H FL P . E .# 58705 73 13/16" MAX. WIDTH � �— 110518 MAX . WIDTH � 145 3/8" MAX . WIDTH 95 3/4" HEMAK IGHT / / / / / / ALLRood ORO OX OR XO OXO OXXO ( SHOWING EACH VERSION SIDELITE ) 37" 36 11 /16" 36 11 /1611 MAX . WIDTH MAX . WIDTH MAX. WIDTH 25" MAX. 71 3/4" MAX. WIDTH 25" 33 3/16" ROORRO DLO ALL X I MAX . DLO MAX . DLO UNITS 79 1 /8" MAX. oA ORR as " k iMakong code i �` ` ONY LYNX RR ORO, `at� ��cErosefl X XX Q` '0 = O ( FULL JAMB ) O ( NARROW JAMB ) _ :: No . 58705 WO NOTES : — 1 . CONFIGURATIONS WITH SIDE LITES CAN BE EITHER NARROW JAMB OR FULL JAMB VERSION . e � 2 . FOR ANCHOR SPACING AND DETAILS SEE SHEETS 10 THROUGH 12 , " � '• 7TATE 3. FOR VERTICAL SECTIONS SEE SHEET 5 AND FOR HORIZONTAL SECTIONS SEE SHEET 6. �Ot,'{ . . F ; 1070TECHNOLOGYDRNE %\` cZORiGP • . ' N. VENICE, FL M275 EXAMPLE ELEVATIONS �'SS�ONAL ECG MI) 480-1600 rt�s ' r r r ! 1 t \ \ R"%d Wm °MW REGIS7RA770N#20296 ALUM. FRENCH DOOM & SIDE LITES, IMPACT AGK 04/17/20 I�GH� Na CHMGES THIS SHEET s nw A. LYNN MILLER , P . E. Dram syc > FIC 12123/04 LT. 4/aw FD750 NIBS 4 d 12 8000- i1 H FL P . E .# 58705 VERTICAL SECTION A 1 VERTICAL SECTION B NARROW AND FULL OUTSWING HEAD JAMB SIDE LITE HEAD 4 61 6 4 oR 7 23 6 D ORIGINAL VERSION TOP RAIL A B B A 21 55 ALTERNATE VERSION TOP RAIL J� C D D C MAX . DLO MAX. DLO � m EXTERIOR INTERIOR EXTERIOR INTERIOR MAX . MAX. HEIGHT HEIGHT ORIGINAL VERSION BOTTOM RAIL 22 56 ALTERNATE VERSION BOTTOM RAIL 2 tl 6 10 L+CENS� 23 OR 24 wv No , 587 VERTICAL SECTION C VERTICAL SECTION D 05 NARROW AND FULL OUTSWING SILL ' . �V4tTE TF * T : '• • JAMB SIDE LITE SILL to7o. CE FL v 5 VERTICAL SECTIONS (941) 4804600 TEX Pond Br. r"ISMA71001 ALUM. FRENCH DOOR & SIDE LITES, IMPACT AGK 04117720 H NO CHANGESTI•l1SSHEET s sn r A . LYNN MILLER, P . E . F►c 12123104 Fay LT ° ® M ' �/2 5 12 8000- 11 H FL P . E.# 58705 4✓8/05 OXXO HORIZONTAL SECTION SHOWING ( 1 ) OF EACH SIDE LITE TYPE - - --�� r � r 53 52 _ _ _ kkk 26 20 105 20 SEE NOTE 81 1 82 E <F > G t 6 ftl 29 NOTE: ASSEMBLY HARDWARE QTY (3) , 11 " $ $ FROM TOP & BOTTOM AND ONE AT MIDSPAN am DETAIL J 30 INTERIOR 20 5 46 SLAB AT 26 GLASS BED 27 1 83 DETAIL G STILES AT ASTRAGAL DETAIL F FULL JAMB SIDE LITE 6 82 $ 1 SEE NOTE 6 82 81 SEE NOTE (AT HINGE JAMB ) EXTERIOR 5 5 1 20 106 20 1 106 L -- - 6 wilit the Flerw 80 30 D 7 a& p qw : Z . 03 30 ( I �m=v� 27 80 20 27 LYIVNjf,,� / 70 , . LkcENsS. . �� 29 83 70 29 83FF ; 1 DETAIL E DETAIL I IF No , 58705 DETAIL H DETAIL K NARROW JAMB SIDE LITE HINGE JAMB TO HINGE JAMB JAMB , FULL JAMB JAMB , NARROW SIDE LITE JAMB SIDE LITE = � •• '� 0 41 (AT HINGE JAMB ) ( NOT SHOWN ABOVE ) 01 . STATE O �� 1070TECHMMOGYDRIVE �� `� ' • . 40MOA . • No VENICE, ri. 3az75 __..._� OR T SEC i lO DETAILS �'��`S/QrVAL (941) 4804600 ubc RwadBra °atm RmWonw REG/STRA770N #29238 ALUM. FRENCH DOOR SIDE LI?'ES, IMPACT AGK 04117120 H NO CHANGES 7HISSHEET Dmm sr TiT � � A. LYNN MILLER , P . E . F.IC 12=104 L. T. �dW5 FD750 112 S d 92 8000- 19 H FL P. E.# 58705 FD750 DOOR(S) FD750 FULL JAMB SIDE LITE ITE7VI DWG# DESCRIPTION PGT# ITEW DWG # DESCRIPTION PGT# FRAME KIT PARTS 1 8006 FRAME - HEAD. SILL & JAMB 68006 1 8006 FRAME - HEAD & HINGEJAMB 68006 4 8008 DRIP CAP 69008 2 8003C OUT-SWINGSILL 68003A 6 8007 SCREW COVER 68007 3 8004C OUT-SWING SILL COVER 68004C 7 8009 IINSTALL PLATE 69009 4 8008 DRIP CAP 68008 8 ----------- FRAME.ASSEMBLY SCREW #8 X 1 " PH QUAD 781PQA 5 -- - HEAD, SILL & JAMB WEATHERSTRIP (SCHLEGAL) U83337T8500 20 8012 STILE 68012 6 8007 SCREW COVER 68007 21 8014 TOP RAIL 68014 ANCHOR/SUBSTRATE MATERIAL PROPERTIES : 7 8009 INSTALLPLATE 68009 22 8013 BOTTOM RAIL 68013 Material Min: Fy Min. F 8 - - FRAME ASSEMBLY SCREW # 8 X 1 " PH QUAD 781PQA 35 --- THREADED ROD 5/ 16- 18 X 36" 6TRODA #12 Steel Screw 92 ksi 120 ksi 9 8032 ASTRAGALENDSEAL 48032 36 FLANGED HEX NII'TSl16-18 7990NUTA #12 18-8 Screw 60 ksi 95 ksi 10 8058A OUT-SWING SELL (LOW RISE) 68038 37 8039 TRUSS CLAMP 60378M # 12 410 Screw 90 ksi 110 ksi DOOR PANEL 1 /4" Elco UltraCon® 155 ksi 177 ksi 60 -"---- # 8 X 34' PH SQ DRIVE TEK SCREW 78X34PSTW 5 — HEAD, SILL & IAMB WEATHERSTRIP SCHLF.GAL U83337T8500 61 8028 SIDE LITE HEAD. TRIM G8028 1 /4" DeWalt UltraCon+® 148 ksi 164 ksi 20 8012 STILE 68012 1 /4" 410 SS Elco/ Dewalt CreteFlex® 127A ksi 189. 7 ksi 62 8029 SIDE LITE JAMB TRIM 68029 21 8014 TOP RAU,, MIRFADED ROD DESIGN) 68014 6063-T5 Aluminum 16 ksi 22 ksi 22 8013 BOTTOM RAIL, (THREADED ROD DESIGN) 68013 FD750 NARROW JAMB SIDE LITE A36 Steel 36 ksi 58 ksi 23 8017 TOP SWEEP 68017 1 8006 FRAME - HEAD & SILL 68006 L. Gr. 33 Steel Stud 33 ksi 45 ksi 24 8016 BOTTOM SWEEP 68016 4 8008 DRIP CAP 68008 25 SWEEP SCREWS 44X 1/2" PHILPH 6 8007 SCREW COVER 68007 26 8015 ASTRAGAL, ACTIVE & INACTIVE 68015 7 8009 INSTALL PLATE 68009 27 802113 GEARHINGE, JAMB SIDE 68021B 8 ----------- FRAME ASSEMBLY SCREW 48 X 1 " PH QUAD 781PQA 28 8020A GEARHINGE, COVER 68020A 21 8014 TOP RAIL 69014 29 8018 GEARHINGE, BACK-UP PLATE 68018 22 8013 BOTTOM RAIL 68013 30 8019A GEARHINGE, DOOR SIDE 68019A 35 ------ THREADED ROD 5/ 1 & 18 X 36" 6TRODA 31 8035 GEARHINGE BEARING 68035 36 ----------- FLANGED HEX NUT 5/ 16-18 7990NUTA 32 --"------- GEARHINGF SET-SCREW #6-32 x l/4" 37 1 8039 TRUSS CLAMP 60378M 33 ------ GEAR HINGE, MTG. SCREW # 12x3/4" TRUSS HD. 60 ------- # 8X3/4" PHSQDRTVETEKSCREW 78X34PSTW 34 — GEARHINGE, MTG. SCREW #12 x 1 1/2" TRUSSED. 61 8028 SIDE LITE HEAD TRIM 68028 35 --- THREADED ROD 5/ 1& 18 X 36" 6TRODA 70 8010 FRAME, JAMB 68010 36 — — FLANGED HEX NUT5/ 16- 18 7990NUTA ASSEMBLY KIT 37 8039 TRUSSCLAMP 60378M 80 8033B FRENCH DOOR ASSEMBLYBEAM. 68033B 38 8043 S/S GEAR LATCH MECHANISM (ASHLAND) gl ------ # ] 0-24X 2 1!2" PH SCREW 39 8030 LOCK BLOCK 48030 82 ----------- # IG-24 HEX NUT 40 — LATCH ASS'YSCREWS # 8 X 2" SS PHILLTRHD 78X2TPAX 83 # 12 X 1 1/2" TRHD TEKSCREW 41 8037 S/S SHOOT BOLT ROD (SULLIVAN) 84 1 8056 SUBSILL (OPTIONAL) 68056 42 8045 STANDARD FLUSH BOLTS W/ SS ROD (SULLiVAN) GLASS, BEADS & SILICONE 43 8031 SHOOT BOLT GUIDE 48031 g , G 44 SHOOT BOLT GUIDE & STRIKE SCREW 8-32 X 3/8" SS PHILL TR HD 78X38PFTX GLAZING SEA LANT, DOW CORNING791, 899, 983 OR 995 as plu It Io 91 — 7/16" LAMINATED GLASS (3116" ANN,,.090PVB, 3/ 16" HS) m* g Code 45 8038R RIGHT- S'TRIKEPLATE AT ASTRAGAL (ACTIVE HINGED LEFT) W5110-43S1 Acceptance N� ye wt- 92 7/ 16" LAMINATED GLASS (3/ 16" HS.,.090PVB, 3/ 16" HS) 46 8038L LEFT - STRIKE PLATE AT ASTRAGAL (ACTIVE HINGED RIGHT) W5110-44S 1 IFftt� 47 STRIKE PLATE SCREWS 8-32X 3/8" SS PHILLTRHD 78X38PFTX 93 --------- 7/16" LAMINATED GLASS (3/16" ANN.,.075 VANCEVA , 3/ 16" HS) 48 STRIKE PLATE MIDDLE SCREW 6 24X 1/2" FH 7612FPTX94 7/ 16" LAMINATED GLASS (3/ 16" HS.,.075 VANCEVA, 3/16" HS) 4 + 49 8036 STRITCE PLATE AT HEAD & SILL 95 7/8" LAMI LG (3/ 16" T, 1 /4" SPACE, 3/16" ANN,,.090 PVB, VIC' HS) I 50 — HEAD STRIKE SCREWS SS 8 X 1/2 PHILL FH 78MZAX 96 I----------- 7/8" LAMI I.G (3/16" T, I /4" SPACE, 3/ 16" HS.,.090 PVB, 3/ I6" HS) ------ --- 7/8" LAMI I.G 3/16" T, 1/4" SPACE, 3/ l6" ANN.,.075 VANCEVA, 3l16" HS)51 — STRIKE PLATE SCREWS ( SILL SS 8 X 1/2 PHI11, UNDERCUT FH 78X12PFHUX 97 - ( 52 8041 ACTAETRIM SET (ASHLAND) 98 7/8" LAMI LG (3/16" T, 1 /4" SPACE, 3/16' HS .,.075 VANCEVA, 3/16" HS) \, F � (� ,'r 1, LY }l(�/ ;✓ .°// 53 8042 PASSTVE TRIM SET (ASHLAND) 105: 8022 BACKBEAD 68022 �� /�Y ` • ' ` CEsu °< i < t 54 8044 STAINLESS STEEL PASSIVE LOCK GEAR (ASHLAND) 106 8026A SLBACKBEAD 68026A 55 8014A TOP RAIL (LAGBOLT DESIGN) 68014A 107 f 8023A 7/ 16" BEAD 68023A _A No . 58705 56 8013A BOTTOM RAIL (LAGBOLT DESIGN) 68013A 108 1 8024A 7/8" IGBEAD 68024A (� 57 - - 5/l6" x2 1/2" LAGBOLTS 7516LBOLTX 109 1 1224 VINYL, BULB WSTP (THICK) 6TP247 n� ;0 0 0 = �t+ , ; A ! E 1• �1 1070 TECHNOLOGY DRIVE r f h D NaVENICE, a34275 PARTS LIST (941) 4804E00ITAW r ,'/ O ,'1AL ', � �� ' R®vsd 8y: � R® s REGISTRATM #29295 ALUM. FRENCH OO & SIDE LIT-iES, I PACT" ' I / I I 1 1 1 l + " AGK 04117120 1 H I ADDED BACKBEDDING. SMWAWodebsir nb Rer A . LYNN MILLER, P . E . Drawn Bra Dab: gmckad twfo: F.K. i2/23l04 L.T. 418105 FD750 A 7 or 12 8000- 11 H FL P . E .# 58705 1 , 278 �-�- . 062 �r 062 2 . 236 . 050 1 . 160 1 . 000O . 583 . 311 4 . 027 3 . 636 - 1 . 353 1 . 033 . 050 0403 . 686 I 1) .#8006 6063 -T6 # 8003C 6063-T6 #8004C 6063-T5 #8008 6063 -T6 #8007 6063-T6 O FRAME , HEAD , JAMB O OUT-SWING SILL O OS SILL COVER O DRIP CAP ` 1 SCREW COVER AND SIDELITE SILL - 1 .27 {�- � �`-- 074 - �'`� 3 . 018 . 062 O 2. 000 1 . 940 IEi 1 . 376 1 .498 583 050 F I ® 3 .636 -¢ I I `,, 3 .990 ----•_- if . 050 7 #8009 6063 -T6 @OUTvomSWING 8058A 6063 -T6 #8012 6063 -T6 238017 6063-T5 INSTALL PLATE LOW SILL O STILE @ TOP SWEEP 075 t 1 . 938 -�' 100 1 . 938 1 .467 :797 Q 8 .250 - i I �- 4 .434 ------a- I 22 #8013 6063-T6 21 #8 TS BOTTOM RAIL TOP RAIL 24 BOTTOM SWEEP s , 075 075 - 'j n e m is 1 . 938 . 100 1 . 938 T -� : ' i � :j 1 .467 1 . 170 - ` 8 :250 - 4 . 434 e- I 2 . 544 ---*�� , ` � � , fr � � ! #8013A 6063 -T6 #8014A 6063-T5 #8015 6063 -T6 \ to��at� cF SF�lh��l%, 56 BOTTOM RAIL , LAG BOLT DESIGN 55 TOP RAIL , LAG BOLT DESIGN 26 ASTRAGAL to 0 No * 58705 a �0 44 STA E 0 to (441 1070 TECHNOLOGY DRIVE two % rt 0 P. 1 to N � af� EXTRUSION PROFILES ''�i'f Ot�A1 , � REGZTRA77av ALUM. FRENCH DOOR SIDE LIT ES, IMPACT � � 1 AGK 04117120 H NOCHMGES7HISSHEET I I s r� Drawn proi I � A. LYNN MILLER, P . E. Dawoat Fa 12123/�1 cx LT. 4/8/D5 Fn�So 9/2 d 12 8000-19 JHJ FL P. E .# 58705 www 142 i 742 075 075 . 301 �— 2 .260 --+� l . 353 L.-- 1 . 763 ® � �— *-- 2 .438 —� 4 072 27 #8021 B 6063-T6 28 8020A 6063-T6 29 #8018 6063-T5 30 #8019A 6063 -T6 GEAR HINGE , JAMB GEAR HINGE , COVER HINGE , BACK- UP GEAR HINGE , DOOR 125 3 .251 Q62 3 . 775 1 . 812� L . 050 1 . 000 . 438 1 . 000 L4- 1 .635 2 .622 —� A25 050 . 325 3 .636 ---d- h100 8033B 6105 -T5 #8028 6063 -T5 #8056 6063 -T4 g FD ASS 'Y BEAM 61 SL HEAD TRIM 84 SUBSILL , OPTIONAL 70 #8010 6063-T6 37 #8039 6063-T6 NARROW SL JAMB TRUSS CLAMP 045 1 J1 . 169040 .442 . 96 . 750 . 045 + -- 2 . 313 iotooto T0, 437. 965 . 045 . 818 r-a- .957 �— . 050 10 #8022 6063 -T5 106 #8026A 6063 -T5 10 #8023A 6063 -T5 108 8024A 6063-T5 62 #8029 6063 -T5 BACKBEAD O SL BACKBEAD 7 / 16 " BEAD I . G . BEAD SL JAMB TRIM ALUMINUM SILICONE HOT-MELT BUTYL REINFORCEMENT POLYISO- DESICCANT FILL AREA STRUCTURAL BUTYLENE STRUCTURAL SILICONE 3/16" NOM. 5/16" NOM . SEAL 5/16" NOM. POLYISTRUCTU AL 1 /4" NOM. FOAM SILICONE SEAL WITH BUTYL & ROLL-FORMED WITH DESICCANT DESICCANT DESICCANT STAINLESS STEEL FOAM EXT. GLASS EXT. GLASS EXT. GLASS EXT. GLASS Ise A � za� Ns 2 . INT. GLASS INT. GLASS INT. GLASS INT. GLASS lR KODISPACE SUPER DURASEAL® XL EDGE '"'' '` 100 4SG TPS SPACER® NXTTm , 02 SPACER 03 SPACER of Part # Description Material \�.� 0t1. 1 � , � /f 100 Kommeding 4SG TPS Spacer System two, oi%o, v�cErds� 'go . 1�� 101 Quanex Super Spacer nXT with Hot Melt Butyl See this = No 58705 102 Quanex Duraseal Spacer Sheet for ' _ Materials _ —p 103 Cardinal AL Edge Spacer = ;Cl U REFERENCE TEST REPORTS: FTL-8717 , 8968 & 8970 � O� ' . o ST TE O �( \ 1070TECHNOLOGYDRIVE ii `SS . FCGRiDP; .f to • �\\�` N VENICE, FL 34275 RUSIO PROFILES %,f /0NA), S\ (941) 480.1800 'nCee , / l % i I I 114 � � \ 1 pmw wo REGISTRA804 ALUM. FRENCH DOOR & SIDE LITES, IMPACT AGK 04117120 H NO CHANGES THIS SHEETInc S&*&Sbft s sit u w � A. LYNN MILLER , P . E. DMM sy Fez rrra acre7T 7 F.IG 1212"4 LT. M8{05 FD750 112 9 12 8000- 11 H FL P . E.# 58705 12" 9 9„ 6"r 1611 r 61' r -1611 6 6 it 1) 6 6 6 ' „ 11 " 11 3" MIN . ' ' HEAD & SILL 11 1 " MIN . HEAD & SILL 11 TYP . ANCHOR TYP , ANCHOR CLUSTER CLUSTER 10 . 571 " (TYPICAL) (TYPICAL) 10 . 571 " MAXI SEE NOTE 4 SEE NOTE 5 MAX O . C . A, ,V w O .C. JAMB JAMB IV IV JAMB m, ,A JAMB ANCHORS 18 . 500" ANCHORS VI IV ANCHORS 18 * 5001, ANCHORS HT. QTY, MAX. O . C . HT. QTY HT. QTY. MAX. O . C. HT . QTY. 95 314" - (5) 95 3/4" - (8) 95 3/4" - (5) 95 3/4" IV (8) 91 3/4" IV (5) 91 314" IV (8) 91 3/4" - (5) (2) EQ . (3) EQ• 91 3/4" - (8) 87 3/4" - (5) IV 87 3/4" - (8) VI 87 3/4" - (5) SP . TYP , SP . TYP. 87 3/4" - (8) 83 3/4" - (5) V, IV V, 83 314" - (7) 83 3/4" - (5) 83 3/4" - (7) 79 3/4" - (5) 11 ,f 79 3/4" - (7) 11 „ 79 3/4" - (5) 11 79 3/4" - (7) 11 " DETAIL A ( CONCRETE ) DETAIL B (WOOD/ALUM . )/APPLICABLITY DETAIL C ( CONCRETE ) SEE NOTE 5 DETAIL D ( WOOD/ALUM . ) ( SINGLE PANEL ) (SINGLE PANEL) (2 OR MORE PANELS ) REGARDING (2 OR MORE PANELS ) APPLICABLIED ANCHOR. TYPES . ANCHOR TYPES : ANCHOR TYPES : ANCHOR TYPES : OF CIRCLED B OR C C OR A B OR C ANCHOR C OR A E NOTE 4 REGARDING LOCATIONS ANCHORAGE SPACING REQUIREMENTS : NHORLOLOCATIONS ANCHOR LOCATIONS 1 . DETAILS A AND B ABOVE REPRESENT ANCHORING OF SINGLE X DOORS , OR INDIVIDUAL SIDE LITE 0 PANELS WITH FULL OR NARROW WIDTH JAMBS. DETAILS C AND D ABOVE REPRESENT ANCHORING OF ANY MIXTURE OF DOUBLE XX DOORS , SINGLE X DOORS , NARROW JAMB OR FULL JAMB SIDE LITE PANELS , FOR MULTIPLE-PANEL INSTALLATIONS OF TWO OR MORE PANELS . UNLESS OTHERWISE STATED, DIMENSIONS OF DETAILS A THROUGH D ARE MAXIMUMS . 2 . ANCHOR TYPES : ANCHOR TYPES : SEE TABLE A, SHEET 1 FOR ANCHOR TYPES , SUBSTRATES AND LIMITATIONS . 3 . SINGLE PANEL CONFIGURATIONS : (DETAIL A , CONCRETE SUBSTRATE . DETAIL Be WOOD/ALUM . SUBSTRATE) wVVVVmVVV HEAD AND SILL . . . . . . 6" MAX. FROM FRAME CORNERS . mmmmImImm JAMBS . . . . . . . . . . . . . . . . . . . . . 11 " MAX. FROM FRAME CORNERS , 18 . 500" MAX. O . C . CONCRETE SUBSTRATE (DETAIL A) AND 10, 571 MAX. O . C. WOOD SUBSTRATE (DETAIL B) . 4 , TWO OR MORE PANEL CONFIGURATIONS : (DETAIL C . CONCRETE SUBSTRATE) co p. ng morn the R h�idfflgcodc HEAD AND SILL: 6" MAX. FROM FRAME CORNERS IF PANEL WIDTH IS 15 OR GREATER AND Acceptance N020= AT 3" , 6" AND 9" MAX. ON EACH SIDE OF ASSEMBLY BEAM AND/OR ASTRAGAL LOCATIONS (CLUSTER OF 6) . '; ate JAMBS : 11 " MAX. FROM FRAME CORNERS AND 18 , 500" MAX. O . 0 � � `` m 4 a 5 . TWO OR MORE PANEL CONFIGURATIONS : ( DETAIL D , WOOD/ALUM . SUBSTRATE) HEAD AND SILL: 6" MAX. FROM FRAME CORNERS ANDlee. AT 3 , 6" , 9" AND 12" MAX. ON EACH SIDE OF ASSEMBLY BEAM AND/OR ASTRAGAL LOCATIONS (CLUSTER OF 8) . � �� 6 . ' ' ��GENSF IV CIRCLED ANCHOR OUTSIDE CLUSTER REQUIRED IF PANEL WIDTH IS OVER 27-3/4" . No . 58705IV V0V ' VIV * --- JAMBS : 11 " MAX. FROM FRAME CORNERS AND 10. 571 " MAX. O . 0 rTT 4C/\ 1070TECHNMOGYBRIVEF< OR14 � . N VENICF FL SC75 ANCHORAGE SPACING � 8/OIVAL ����\(941) 4$04600 Tmw J/ I j l l l ! ! I I 1 1 \ \ PurvadBro aam: WGISMATION,A292� ALUM. FRENCH DOOR & SIDE LITES, IMPACT AGK W17120 H NO CHANGES THIS SHEET s s� ram. � A. LYNN MILLER , P . E . F.K �3104 LT. 4AW5 ® FD750 114 10 of 12 8000- 11 H FL P . E .# 58705 TYP . ANCHOR TYPE, TYP . ANCHOR TYPE, TYP. ANCHOR TYPE , TYP . ANCHOR TYPE , EMBEDMENT AND EDGE EMBEDMENT AND EDGE EMBEDMENT AND EDGE EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, DISTANCE PER SUBSTRATE, DISTANCE PER SUBSTRATE , DISTANCE PER SUBSTRATE, SEE TABLE A, SHEET 1 . SEE TABLE A, SHEET 1 . OPTIONAL SEE TABLE A, SHEET 1 . SEE TABLE A, SHEET 1 . OPTIONAL 1 /4" MAX. 84 1 /4" MAX. 84' 1 i4" GROUT, 1 /4„ MAX. GROUT GROUT MAX. SEE SEE SEE VVVVVVV SHIM NOTE 3 NOTE 3 NOTE 3 Ift. ,. ., \ t METAL SUBSTRATE '- S 2X WOOD 2X WOOD�- -�� PER ANCHOR :. CONCRETEICMU :' :' %;` EMBEDMENT BUCKSTRIP BUCKSTRIP OR REQUIREMENT PER ANCHOR ,,,, , ,: FRAMING , SEE EMBEDMENT FRAMING , SEE EMBEDMENT EDGE DISTANCE REQUIREMENT ,' : NOTE 1 THIS SHEET NOTE 1 , THIS SHEET 1 /8" MIN . EMBEDMENT (METAL THICKNESS) EDGE DISTANCE —om EDGE DISTANCE EDGE DISTANCE �- TYPICAL SIDE LITE SILL TYPICAL SIDE LITE SILL TYPICAL SIDE LITE SILL TYPICAL SIDE LITE SILL (DIRECT TO METAL) (DIRECT TO CONCRETE) (DIRECT TO WOOD) (DIRECT TO WOOD) EXTERIOR INTERIOR (ALL HEAD & SILL SECTIONS) EMBEDMENT 1X WOOD 2X WOOD BUCKSTRIP OR FRAMING , EDGE DISTANCE SEE NOTE 1 , THIS SHEET BUCKSTRIP , SEE 1 /8" MIN . EMBEDMENT (METAL THICKNESS) EDGE DISTANCE —p- { NOTE 1 ; THIS ; CONCRETE/CMU ::; . -41 EDGE DISTANCE SHEET. or V. PER ANCHOR " ' " EDGE DISTANCE —s - I-4 - CONCRETEICMU ! " REQUIREMENT . , ' METAL SUBSTRATE 1 /4 PER ANCHOR _ 4 1 /4" o PERANCHOR EMBEDMENT V ` I EMBEDMENT MAX. REQUIREMENT . ;� ; ` : : MAX. 1 /4 REQUIREMENT SHIM SHIM MAX• c ' SHIM 1 /4" MAX. IV ISHIM TYP . ANCHOR TYPE, TYP , ANCHOR TYPE , TYP . ANCHOR TYPE, TYP , ANCHOR TYPE, EMBEDMENT AND EDGE EMBEDMENT AND EDGE EMBEDMENT AND EDGE EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, DISTANCE PER SUBSTRATE, DISTANCE PER SUBSTRATE, DISTANCE PER SUBSTRATE, SEE TABLE A, SHEET 1 , SEE TABLE A, SHEET 1 . SEE TABLE A, SHEET 1 . SEE TABLE A, SHEET 1 . TYPICAL DOOR & SIDE LITE HEAD TYPICAL DOOR & SIDE LITE HEAD TYPICAL DOOR & SIDE LITE HEAD TYPICAL DOOR & SIDE LITE HEAD (DIRECT TO METAL) ( DIRECT TO CONCRETE) (THRU 1X INTO CONCRETE) (DIRECT TO WOOD) NOTES : 1 . WOOD BUCKS DEPICTED AS 1x ARE LESS THAN 1 -1 /2" THICK. lx WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE, WOOD BUCKS DEPICTED AS 2x ARE 1 - 1 /2" THICK OR GREATER. INSTALLATION TO THE SUBSTRATE OF WOOD BUCKS TO BE ENGINEERED BY OTHERS OR AS APPROVED BY THE AUTHORITY HAVING JURISDICTION (AHJ) . IV It It 2 . FOR ATTACHMENT TO ALUM : THE MAT' L SHALL BE A MIN . STRENGTH OF 6063-T5 AND A MIN , OF 1 /8" THICK, THE ALUM , STRUCTURAL MEMBER SHALL BE OF A SIZE TO \�.� .( LYN/V PROVIDE FULL SUPPORT TO THE DOOR FRAME SIMILAR TO THAT SHOWN IN THE DETAILS ON THIS SHEET FOR 2x WOOD BUCKS , THE ANCHOR SHALL BE A #12 SMS `�G • ' ' �cts ��� WITH FULL ENGAGEMENT INTO THE ALUM . IF THESE CRITERIA ARE MET, THE PRESSURES SHOWN ON SHEET 2 AND ANCHORAGE SPACING FOR WOOD SHOWN �Z ON SHEET 10 MAY BE USED . � y No . 58705 = 3 . IF SILL IS TIGHT TO SUBSTRATE , GROUT OR OTHER MATERIAL IS NOT REQUIRED . IF USED , NON-SHRINK, NON-METALLIC GROUT, 3400 PSI MIN . , (DONE BY OTHERS) _ .� ffi _ MUST FULLY SUPPORT THE ENTIRE LENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE, AND TRANSFER SHEAR LOAD TO SUBSTRATE. - " _ 7 FTE � � Q' `1°N rC9�Y3a7 A CHO C 7" &S rv�v coking ngwiththe Rod& (841) 460.1500 y �+ p { ^� �+ A �cy- iT �lGfitOP , . • ' � afl sJ ALUM. FRENCH ® a7! E L I6 a7 IMPACT f �i�Ls J • . . . , . • ��`C'} CERT. OFAUlH 9298s �/ ! ! ' 0n IAL ` > >\� � Expi"mdsnaOD S0*266DCAINk ®750 1/4 19 d 92 5000- 11 t � . � Rewdsr. DOW: per. IN, a cer7 A. LYNN MILLER , P. E. AGK 04117120 H NO GESTHISSHEET. F.IG 2/23f04 L. T. 4/Ri05 FL P . E.# 58705 TYP . ANCHOR TYPE, TYP . ANCHOR TYPE, TYP . ANCHOR TYPE , TYP . ANCHOR TYPE, EMBEDMENT AND EDGE EMBEDMENT AND OPTIONAL EMBEDMENT AND EDGE EMBEDMENT AND OPTIONAL DISTANCE PER SUBSTRATE , EDGE DISTANCE PER DISTANCE PER SUBSTRATE, EDGE DISTANCE PER SEE TABLE A , SHEET 1 . SUBSTRATE , SEE 84 SEE TABLE A, SHEET 1 . SUBSTRATE, SEE 84 TABLE A, SHEET 1 . TABLE A, SHEET 1 . EXTERIORZ < EXTERIOR < EXTERIOR < EXTERIOR2OR OR 1 /4" MAX• OR 1 /4" MAX. 10 1 /4" MAX. 10 I 10 MAX4 GROUT, � SEE NOTE loolooto GROUT,SEE NOTE 03 SEE NOTE 3 ,SHIMET 11� 3 , SHEET 11 SHEET 11 SHE top to A, =. _:, loll ,.j : i-s'. , 1.If z . :. . y .' .. Y ' ,: tooA nNOTE . X WOO 00METAL SUBSTRATE 4 T : . ; • .PER ANCHOR EMBEDMENT , lPA . - CONCRETE/CMU BUCKSTRIP OR BUCKSTRIP OR REQUIREMENT lot, PER ANCHOR EMBEDMENTFRAMING , SEE EMBEDMENT FRAMING , SEE REQUIREMENT 1 , SHEET 11 . NOTE 1 , SHEET 11 . EDGE DISTANCE --1 118" MIN . EMBEDMENT (METAL THICKNESS) TYPICAL DOOR SILL TYPICAL DOOR SILL TYPICAL DOOR SILL OPTIONAL DOOR SILL ( DIRECT TO METAL) ( DIRECT TO CONCRETE) ( DIRECT TO WOOD) ( DIRECT TO WOOD) TYP . ANCHOR TYPE, 4 TYP . ANCHOR TYPE TYP . ANCHOR TYPE, INTERIOR TYP . ANCHOR TYPE, INTERIOR INTERIOR EMBEDMENT AND EDGE EMBEDMENT AND EDGE EMBEDMENT AND EDGE EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE , DISTANCE PER SUBSTRATE, DISTANCE PER SUBSTRATE , DISTANCE PER SUBSTRATE , SEE TABLE A, SHEET 1 . SEE TABLE A, SHEET 1 . SEE TABLE A, SHEET 1 . SEE TABLE A. SHEET 1 . alt . AAt o a A k- EMBEDMENT EMBEDMENT EMBEDMENT EMBEDMENT EDGE EDGE EDGE F-a-' 1 /4" MAX . SHIM EDGE - DISTANCE DISTANCE ' ., ''' ,.- i DISTANCE 1 : DISTANCE ' • Afs ; � .t METALIt 2X WOOD oil 4" `4 BUCKSTRIP OR SUBSTRATE CONCRETE/CMU CONCRETE/CMU . : - ' : ' PER PER ANCHORo PER ANCHOR " ~ FRAMING , SEE r . ? r : . : - too too , ANCHOR REQUIREMENT REQUIREMENT .' , ^ ' : < NOTE 1 , SHEET 11 . REQUIREMENT : . • . All 1 /4" MAX. SHIM -► ) -�- 1 /4" MAX. SHIM -� 1X WOOD TYPICAL DOOR & SIDE LITE JAMB 1 /4" MAX . SHIM -� �- BUCKSTRIP , SEE ( DIRECT TO WOOD) NOTE 1 , SHEET 11 . TYPICAL DOOR & SIDE LITE JAMB TYPICAL DOOR & SIDE LITE JAMB TYPICAL DOOR & SIDE LITE JAMB &RQ, - (DIRECT TO METAL) ( DIRECT TO CONCRETE) (THRU 1X INTO CONCRETE) \��` � C jA`{ LYNAV' 6vwfift cum qAAA. � ��cE �vsF . 1�� .�too 7 No . 58705 All — 6?Alto, � loofto 10707ECHNOLOGYDWE '. 0 0 ( All �� AL VEMICE, FL 34275 CH® DETAILS = o TATE Ftoot GV (941) 4604600 7mc � �\' cLOR1DF. • ' ' �� � ALUM. FRENCH SIDE L17' S, IMPACT T. Alto Sr � PVAL CER OFAU7N, / Sf C IDF —750 114 12 of12 800041 • ' ' ' ' 11 ' ' ` \ \ Rend Srw Datk R mar Sr. ' A. LYNN MILLER, P . E . AGX 04117120 H NO CHANGES THIS SHEET. F.XL IDSW 12123104 L,T. 4/8105 FL P - E_# 58705