Loading...
HomeMy WebLinkAboutMICROINVERTER Data Sheet PRELIMINARY Enphase Microinverters Region:AMERICAS Enphase IQ7G+ The high-powered smart grid-ready Enphase IQ7G+ MicroinverterT' dramatically Microinverters simplifies the installation process while achieving the highest system efficiency. Part of the Enphase IQ System,the IQ7G+ Microinverter integrates with the Enphase IQ EnVOyTM, EnchargeTM, and the Enphase Enlighten TM monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell/120 half-cell and 72- cell/144 half-cell modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed eENPHASE IQ 76+ Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) NOTE:IQ7G+should not be installed on the same Envoy along with IQ6 series,IQ7,IQ7+ IQ7X or IQ7A microinverters. To learn more about Enphase offerings,visit enphase.com E N P H AS E Enphase IQ7G+ Microinverters INPUT DATA(DC) IQ7GPLUS-72-2-US Commonly used module pairings' 235 W-440 W+ Module compatibility 60-cell/120 half-cell and 72- cell/144 half-cell PV modules Maximum input DC voltage 60 V Peak power tracking voltage 29 V-45 V Operating range 25 V-58 V Min/Max start voltage 30 V/58 V Max DC short circuit current(module Isc) 15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) 240 V 220 V 208 V Peak output power 295 VA 295 VA 295 VA Maximum continuous output power 290 VA 290 VA 290 VA Nominal(L-L)voltage/range2 211-264 V 194-244 V 183-229 V Maximum continuous output current 1.21 A 1.32 A 1.39 A Nominal frequency 60 Hz 60 Hz 60 Hz Extended frequency range 50-68 Hz 50-68 Hz 50-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 13 12 11 Overvoltage class AC port III III III AC port backfeed current 18mA 18mA 18mA Power factor setting 1.0 1.0 1.0 Grid-tied power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY Peak efficiency 97.8% 97.7% 97.7% CEC weighted efficiency 97.0% 97.0% 96.5% MECHANICAL DATA Ambient temperature range -400C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2")-without bracket Weight 1.08KG(2.38lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. Compliance(pending) CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com loop ENPHASE ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7,Enphase IQ 7+,Enphase IQ Battery, Enphase Enlighten,Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.2021-02-15