Loading...
HomeMy WebLinkAbout24x60 Pole Barn Engineering PlansKim Sparacio 18001 Wagon Wheel Ln, Port St. Lucie, FL 34987 1. ALL CONSTRUCTION SHALL COMPLY WITH 2O20 FLORIDA BUILDING CODE 7th EDITION ULTIMATE WIND SPEED: 140 NOMINAL WIND SPEED: 101 WIND EXPOSURE CATEGORY: C RISK CATEGORY 1 INTERNAL PRESSURE COEFFICIENT Gcpi= +/- 0.0 DESIGN PRESSURE PER FBC CHAPTER 16 DESIGN ROOF LIVE LOAD = 20 PSF DESIGN ROOF DEAD LOAD = 3.5 PSF MIN SOIL BEARING 2500 PSF TRUSS BEARING LOAD EACH END = 4600 LBS TRUSS UPLIFT @ POST = 2880 LBS 1. WOOD FRAMING AND FASTERNERS TO MEET NDS-2018 REQUIREMENTS 2. FASTER REQUIREMENTS: (1) ALL NAILS ARE COMMON GALVANIZED; (2) ALL BOLTS ARE TO BE GALVANIZED STEELAND INCLUDE NUTS AND WASHERS; AND (3) ALL OTHER HARDWARE (SIMPSON, ETC) IS TO BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. NAILING (SIZE AND NUMBER) SHALL SATISFY TABLES 2306.2. (1) AND 2306.3(#) FBC UNLESS OTHERWISE INDICATED. NOTE: FASTERNERS EXPOSED TO THE WEATHER ARE TO BE TREATED FOR WEATHER RESISTANCE AND COMPATIBLE WITH THE TYPE OF PRESSURE TREATED WOOD USED (CONNECTORS, NAILS, BOLTS, NUTS AND WASHERS) 2. CONCRETE CONSTRUCTION NOTES: 1. CONCRETE WORK SHALL CONFORM TO "BUILDING CODE REUUIREMENTS FOR REINFORCED CONCRETE" (ACI-318) ANDE "SPECIFICATIONS FOR STRUCTURAL CONCRETE" (ACI-301), LATEST EDITION 2. CONCRETE MIX SHALL CONFORM TO THE FOLLOWING SPECIFICATIONS. ALL CONCRETE MIXES SHALL CONTAIN A WATER -REDUCING ADMIXTURE CONFORMING TO ASTM C-494. AIR -ENTRAINING ADMIXTURE SHALL CONFORM TO ASTM C-260 CONCRETE MIX ULTIMATE COMPRESSIVE STRENGTH @ 28 DAYS 3000 PSI SLUMP RANGE 4" +/- 1" MAXIMUM AGGREGATE SIZE 1" ENTRAINED AIR NONE DRY WEIGHT PER CUBIC FOOT 150 # 24' x 60' OPEN POLE STRUCTURE 45' BUILDING COMPONENTS & CLADDING LOADS 27^ MEAN BUILDING HEIGHT = 30.0', EXPOSURE "C" ROOF ANGLE 7" TO 27A 7^ O^ LU a vuic vuic vuic vuic O N Q 110 MPH 120 MPH 130 MPH 140 MPH 1 10 12.0 / -19.9 14.9 / -23.7 17.5 / -27.8 20.3 / -32.3 1 20 1 1.4/ -19.4 13.6 / -23.0 16.0 / -27.0 18.5 / -31.4 1 50 10.0 / -18.6 11.9 / -22.2 13.9 / -26.0 16.1 / -30.2 V 0 2 10 1 2.5/ -34.7 14.9 / -41.3 17.5 / -48.4 20.3 / -56.2 � 2 20 11.4 / -31.9 13.6 / -38.0 16.0 / -44.6 18.5 / -51.7 i� LL 2 50 10.0 / -28.2 11.9 / -33.6 13.9 / -39.4 16.1 / -45.7 O 0 3 10 1 2.5/ -51.3 1 4.9/ -61.0 17.5 / -71.6 20.3 / -83.1 3 20 11.41-47.9 13.6 / -57.1 16.0 / -67.0 18.5 / -77.7 3 50 10.0 / -43.5 11.9 / -51.8 13.9 / -60.8 16.1 / -70.5 4 10 21.8 / -23.6 25.9 / -34.7 30.4 / -33.0 35.3 / -38.2 4 20 20.8 / -22.6 24.7 / -26.9 29.0 / -31.6 33.7 / -36.7 4 50 19.5 / -21.3 23.2 / -25.4 27.2 / -29.8 31.6 / -34.6 5 10 21.8 / -29.1 25.9 / -34.7 30.4 /-40.7 35.3 / -47.2 5 20 20.8 / -27.2 24.7 / -32.4 29.0 / -38.0 33.7 / -44.0 5 50 19.5 / -24.6 23.2 / -29.3 27.2 / -34.3 31.6 / -39.8 HEIGHT & EXPOSURE ADJUSTMENT COEFFICIENTS FOR BUILDING COMPONENTS & CLADDING BLDG EXPOSURE EXPOSURE EXPOSURE HEIGHT "B" "C', "D" 15 1.00 1.21 1.47 20 1.00 1.29 1.55 25 1.00 1.35 1.61 30 1.00 1.40 1.66 SHOTCRETE MIX ALL CONCRETE SHALL BE CURED FOR A MINIMUM OF 28 DAYS. IF FORMS FOR VERTICAL SURFACES ARE REMOVED PRIOR TO THE END OF THE CURING PERIOD, SPRAY SURFACES WITH LIQUID MEMBRANE CURING COMPOUND REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 40 (Fy=40 ksi). LAP CONTINOUS BARS FOR TENSION LAP SPLICE PER ACI-318, UNLESS OTHERWIE NOTED. PROVIDE CORNER BARS OF SAME SIZE AND SPACING AS HORIZONTAL WALL REINFORCEMENT. COVER FOR CONCRETE REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ACI-318, PARAGRAPH 7.7 WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. LAP SHEETS TWO MESH SPACES AND WIRE TIE ADJACENTS SHEETS TOGETHER SECURELY. CUT ALTERNATE REINFORCEMENT AT CONTROL JOINTS ALL SLABS ON GRADE SHALL HAVE CONSTRUCTION OR CONTROL JOINTS NOT TO EXCEED 15-0" SPACING, UNLESS OTHERWISE NOTED. ELECTRICAL CONDUIT AND OTHER PIPES TO BE EMBEDDED IN STRUCTURAL CONCRETE FLOOR SLABS OR WALLS SHALL BE PLACED IN ACCORDANCE WITH THE REQUIREMENTS OF ACI-318, PARAGRAPH 6.3 H Uj U� JQJW g 0 w t= 0 = W = m Z Q z i cM N 12'-0" Kim Sparacio 18001 Wagon Wheel Ln, Port St. Lucie, FL 34987 12'-0" • 1 1 12'-0" 12'-0" 24' x 60' OPEN POLE STRUCTURE 12'-0" C` -1- — — — — — — — — — — — — — — — it ICI 1 — — — — — — — — — — — — — — — it ICI 1 — — — — — — — — — — — — — — — l ICI 1 — — — — — — — — — — — — — — — t ICI 1 — — — — — — — — — — — — — — — -- 11IQII 1IQI1 1IQII LIQI1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 18" round x 48" deep footing w/ #5 rebar I I 6x6 pressure treated I drilled thru post each way I I I wood posts (ground contact) I at 4" o.c in bottom of post. I I Post will be set on 4" bed of #5 gravel rock. _ _ _ _ _ _ _ _ _ _ _ _ _ _ T 101 T _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ T 101 T _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ T 101 T _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ T 101 T _ _ _ _ _ _ _ _ _ _ _ FOUNDATION PLAN VIEW SCALE: NOT TO SCALE u" 0 Q O Z w�W O �w I—�con000 00 Q00o 00 F� 3 00� � M op iY W Kim Sparacio 18001 Wagon Wheel Ln, Port St. Lucie, FL 34987 24' x 60' OPEN POLE STRUCTURE I STEEL ROOF TRUSSES I I I I I co w I Q I I OJ I I I co x N I I W I a_ O I I I O J I I I I I I RAFTER FRAMING PLAN SCALE: NOT TO SCALE See sh for post Kim Sparacio 18001 Wagon Wheel Ln, Port St. Lucie, FL 34987 POLE BARN CROSS SECTION "8' 24' x 60' OPEN POLE STRUCTURE L 1-1/2" x 1-1/2" x 3/16" top chord (typ) NOTES: Kim Sparacio 18001 Wagon Wheel Ln, Port St. Lucie, FL 34987 4" wide x 4" x 2" 14ga. purlin connector L 1-1/2" x 1-1/2" x 3/16" welded to truss (typ) L 1-1/2" x 1-1/2" x 3/16" bottom chord (typ) L 1-1/4" x 1-1/4" x 1/8" diagonal & vertical chord (typ) W/ L 1-1/4" x 1-1/4" x 1/8" nested into & welded (typ) 2 - 1/2" dia. carrage thru bolts with nut & washer (typ) 3 - 1/2" Dia. thru bolts thru 5/8" dia. hole (typ) L 1-1/2" x 1-1/2" x 3/16" collar tie attached w/ 2 - 1/2" dia. thru bolts nut & washer @ each end STEEL TRUSS CROSS SECTION 1. MATERIALS SHALL CONFORM TO STEEL ASTM 513 2. ALL STEEL SHALL BE 50KSI IN ACCORD WITH CURRENT AISC MANUAL. 3. WELDING ELECTRIODES TYPE E70XX 4. ALL WELDING SHALL BE IN ACCORD WITH CURRENT AWWA REQUIREMENTS 5. ALL WELDING SHALL BE DONE BY A CERTIFIED WELDER. 6. BOLTS SHALL BE ASTM A325. w/ NUTS & WASHERS (TYP) 7. WELD STRENGTH 70 KSI MIN. 8. ALL POST SHALL BE PRESSURE TREATED GROUND CONTACT. 9. PRIMING & PAINTING SHALL BE DONE BY TRUSS MANUFACTURER. 10. MIN EDGE DISTANCE FOR BOLTS HOLES SHALL BE 3/4" MIN. 11. MAX TRUSS SPACING SHALL NOT EXCEED 12'-0" 12. THE DESIGNER DISCLAIMS ANY RESPONSIBILITY FOR DAMAGES AS A RESULT OF POOR WORKMANSHIP, OR IMPORPER USE, AND ACCEPTS NO RESPONSIBILTY OR EXERCIESES NO CONTROL WITH REGUARD TO FABRICATION, HANDLING, AND INSTALLATION OF TRUSSES. Dia 19. pane/ na/ web ?4„Spaots (ti"' g Purlin c 24„ Spaconnector �g (typ) 24' x 60' OPEN POLE STRUCTURE u" 0 Q O Z w�W O �w I—�con000 00 Q00o 00 F� 3 00� � M o�.w 29ga metal roofing attached in accord with mfr. specifications FL # 9555.5R4 2" x 6" #2 PT SYP purlins @ 24" max spacing 2 - 1/2" dia. carriage thru bolts w/ nut & washer to match 6x6 pressure treated wood posts (ground contact) p It fr Ij 10r\/1V LL 18" (1" rock max) POST & FOOTING SECTION Kim Sparacio 18001 Wagon Wheel Ln, Port St. Lucie, FL 34987 4" wide x 4" x 2" 14ga. purlin connector L 1-1/2" x 1-1/2" x 3/16" 2quSpac°rynacto top chord (typ) ciry9 (typo 1-1/2" x 1-1/2" x 3/16" x 16" nested into & welded to L 1-1/4" x 1-1/4" x 1/8" 1" 1/8"TYP bottom chord for 40ft+ trusses diagonal & vertical chord (typ) W/ L 1-1/4" x 1-1/4" x 1/8" nested 1 1/8'.P into & welded (typ) 3/16" TyP 1-1/2" 3/16"TYp L 1-1/2" x 1-1/2" x 3/16" TYP bottom chord (typ) L 1-1/2" x 1-1/2" x 3/16" horizontal b parye°na/web 3/16" L 1-1/2" x 1-1/2" x 3 6" 2q"Spa°nts TYP vertical 10 city (type 9 16" TRUSS END SECTION TYP 3/16" 1" 1/8'. TYP 2qur/iry cOn 1" 1 /8"TYP Spac/o 9 (type 4" wide x 4" x 2" 14ga. purlin connector L 1-1/2" x 1-1/2" x 3/16" 1" 1/8" TYP vertical center chord 1" 1/8" t 1 chord x 1-1/2" x 3/16" TYP 3/16" t /��>� top chord (typ) TYP "/IL L 1-1/4" x 1-1/4" x 1/8" diagonal & vertical chord (typ) W/ L 1-1/4" x 1-1/4" x 1/8" nested 0la9oaa/ into & welded (typ) 'Oe24 netpointeb �tpacin9S 1" 1/8" YP yp) L 1-1/2" x 1-1/2" x 3/16" bottom chord (typ) 4" wide x 4" x 2" 14ga. rat run connector TRUSS CENTER SECTION 2" x 6" #2 SYP 14ga purlin 2" x 6" #2 SYP fascia attached connector purlins attached to connector w/ 2 - #12 x 3-1/2" screws w/ 4 - #10 lag screws 11 Truss details (see sheet 5 & 6) PURLIN CONNECTION SECTION 24' x 60' OPEN POLE STRUCTURE Z Q O o U Z 0 W` r L 1-1/2" x 1-1/2" x 3/16" 4" wide x 4" x 2" 14ga. Ww o Vuu`� w rat run connector L 1-1/4" x 1-1/4" x 1/8" 41" L oo O w cV diagonal & vertical chord (typ) W/ L 1-1/4" x 1 x 1/8" nested into &welded J^ 3 00 M (typ) L 1-1/2" x 1-1/2" x 3/16" collar ti r/^T/, 1/^�\ cp uj attached w/ 2 - 1/2" dia. thru bolts 3/16" nut & washer @ each end TYP COLLAR TIE SECTION (10 3" C/L 3" 3 - 1/2" Dia. thru bolts thru 5/8" dia. hole (typ) CENTER RIDGE SECTION 2 - 1/2" dia. carrage bolts (typ) ressure treated wood posts (ground contact) POST TO TRUSS CONNECTION