Loading...
HomeMy WebLinkAboutNOA; 5V Crimp Roof PanelD 6'� l�iA�i+�fl•l a � 3 0�- a COPY ILE B DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)' BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE L.V. Thompson, Inc. 5015 E. Hillsborough Avenue Tampa, FL. 33610 MIAMI-DADE COUNTY PRODUCT CONMOL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (796) 315-2599 www.miamidade.gov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. Ifthis product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 5V Crimp Roof Panel LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade Cmmty,Product Control Approved', unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been. no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade -County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 11-0808.09 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. DEC 2 g 202Q &MM1UA%MF=DADEC0UNTY Norman D. Cabrera Florida PE #74093 Reviewed for design intent. NOA No.: 16-1012.17 Expiration Date:11/30/21 Approval Date:11/23/16 1 Page 1 of 5 ROOFING ASSEMBLY APPROVAL: Category Sub-Caftory Material: Deck LMe: Maximum Design Pressure Roofing Non -Structural. Metal Roofing Steel Wood See Table A TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Prod ct Dimensions Test' Product Specifications Description "W" Steel Roofing 1= varies TAS 125 Metal Roof Panel conforming with Panel w = 24" ASTM A792 coated with Aluzinc. h=%2" Min. Thickness 0.019" Min yield strength: 48ksi Trim Pieces l = varies w = varies Thickness 0.0276. MANUFACTURING LOCATION: 1. Tampa, FL. EVIDENCE SUBMITTED: Test Agency Test Identifier PRI Construction Materials LVTI-008-02-01 Technologies LLC LVU-020-02-03 LVTI-021-02.01 LVTI-020-02-02 MIAMI•DADE COUNTY • a TAS 110 Standard flashing and trim pieces. Manufactured for each panel width. Test Name/Report TAS-100 ASTM B 117 / TAS 110 TAS 125 ASTM G 155 Date 08/07/06 10/25/16 10/26/16 11/16/16 NOA No.:16-1012.17 Expiration Date: 11/30/21 Approval Date: 11/23/16 Page 2 of 5 APPROVED ASSEMBLIES: System: "SV-Crimp" Metal Panels Deck Type: Wood, Non -Insulated Deck Description: 15/32" or greater plywood or wood plank. Slope Range: 211: 12" or greater Maximum Uplift See Table A below Pressure: Deck Attachment: In accordance with applicable Building Code, -but in no case shall it be less than .8d annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 1 62" thick (Minimum 15/32") The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type I installed with a minimum 19" side -laps and 6" end lap fastened with corrosion resistant tin -caps and 1'/4" annular ring shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll; followed by one layer of Polyglass TU Plus installed over the ASTM D 226 Type I. Refer to Polyglass USA current published installation instructions. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance, with Roofing Application Standard RAS 133 and with L.V. Thompson Inc.'s current published installation instructions. Metal Panels and Install the 'W" Steel Roof Panels and accessories in compliance with LV Thompson Inc.'s Accessories: current, published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed -in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. Panel fasteners shall .be #911H self tapping screws with sealing washer of sufficient length to penetrate through the sheathing a minimum of 3/16 inch. Fasteners shall be installed at high points of panel ribs (see Detail A) at a maximum spacing as listed in Table A below parallel to the slope. (see Detail B) ,Fasteners shall be installed at a maximum of 12" o.c.at panel edge. TABLE A MAXIMUM DESIGN PRESSURES Roof.Areas Field Perimeter and Corner' Maximum Desi n Pressure -71.25 f ' -1275 psf Maximum Fastener Spacing 16" o.c. 8" o.c, 1. Extrapolation shall not be allowed NOA No.: 16-1012.17 Expiration Date:11/30/21 Approval Date: 11/23/16 Page 3 of 5 L " I . SYSTEM LEMHATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and(or logo, and/or model. aMIDADE COUNTY S. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20 3 of the Florida Administrative Code. NOA No.: 16-1012.17 MIAMMADE CouNTr Expiration Date: 11/30/21 juui Approval Date: 11/23/16 Page 4 of 5 Overlap PROFILE DRAWINGS: DETAIL A W Coverage Minimum #9HHself tapping screws w/ self sealing. it 'Minimum penetration through the deck Overlap END OF THIS ACCEPTANCE 112" NOA No.: 16-1012.17 MMMADe counmr Expiration Date:11/30/21 Approval Date:11/23/16 Page 5 of 5