Loading...
HomeMy WebLinkAboutEngineeringPlan Y NIP 5�1�cre­en -:Room RSun Room QFill In [:]Pool screeplCage* (Non -Removable Scrieen — Designed d [DCarPort F_1 Patio Cover - []Other: istand actual Wind Speed) .Contractor Name:su;fside aluminum and: screens'! *AddreSS x.1 055 1,9th street sm. �City- vero beach •RECEIVEE *Zip Code.- 32962 JUT WJUT0111 "Phone/FaX0.772-521-6204 ST. Lucie Co Email: dnagle27@gmail.com � QOw.F C_h 0" Will 1:1❑Pick. Up DE -File EFed; Eilu, 0. Single PDf:. i. [3 Each Page Separate .'-(ForfedEkoptibw aqd.;proyvdA:i 1 go . . .... *' Payment [Check Z-Credit Card*' (ForCredit Card go to wwxy.,-Juminumscr _W. pay CtO eende.M6 n. 6M Engineering prepared by! lik, R 911f. OR z A MORM D_e W 32 Engineer: Michael Thompson,.MSc, Ef?474C 4401'Vind' 'Vineland:'Road- suite A6 OH60dO, FL 32811. Office:8887'607,0747 or 407-734-1470 Cell.!.467-721 i22! Projed Manager Paul Thomas 1386479-95k ['Oax.* 883-922 endesfanravahbox6m Email- aluminumscre Web8ite: WWW.alQMinUm gcreqn,de'siqHb6ft:( 0 3 8.1 ,of. d Opkes account) card) EYE A g. M- v C4-6 Ultimate , 150. Roof Type:. ` IV, I In Ill lated F] Pan Roo f Roof C6nnedting to: Gutter MFascia [:16lock wall Front Wall': Uprights 2 X4. 'Top Mate Z.- - X3— By Side Weill: Uprights, 2 x4 Top Plate 2 )(8 130: ,Pool Roof Type'. DDome FI.Gable- Fjh -Roof Connecting to: []GutterM Feiscia- F13lock M Roof Beam: Beams X— Uprights. XL_ I Front Milt. Beams -X Uprights—XP.i Side WA116 Beams X. Upoghts —x III F-1 Roof Type: 0 insulated F1Pan. Roof Roof Conne0ing to.: []Gutter [] Fascia []Block Beams X: Post. x w w PlExisting FN'ew 4" W/6" Thickened"Edge Ribbon Footer x With. ,7 Pavers: with Footer X With Other: NoteIn the, opht h ' . is a confli6t m4th the ..t. atthere design plans and gener, utilize the more stringent dime'nsio"ns andmember sizes prior ordering: eh the plans. and the general notes and d' standard, esign s. nd,a' Engineer.. I'Michael , ompsonMSc,P.E. P(13047 0 . .ich 5 9) 4401 Vineland Road Suite A6, Cirlandoi FL 32911_ (CA#30910)-Ph 401 7"734-1 470.117ax 407--134-1196 b -C Risk Category fow 0 Anyl or , Plate.. x sardlkil An: . 6t6s anddE Eht''Wall Chair Rail 2 Chair Rail 2 Kick Pla X3 16 IQ Shed/Slope. I nalfflall 11.1ser ,ithair Rail X i - bait Rail. X Kick Plato ti6-nl;al Wall MV? Wall lard,'the dontrdctot'shall Vor construction! between M ALUMINUM SCREEN DESIGN smAIS DAfuminum 8. Ctib.structi.on En:gtneesing General Notes & Design Standards (Screen Patio Room Enclosure) The following are general design standards. More stringent design standards may be noted on the plans. In the event of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilize the more stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction. Design Codes: Florida Building Code 2020 (71 Edition) Aluminum Design Manual 2020 ASCE 7-16 Design Loads: Pursuant to FBC Chapters 16 & 20 Ultimate Wind: -150 MPH (FBC Table 2002.4) (45 psf) Risk Category: -See attach site specific plan sheet (FBC Table 1604.5) Exposure Category: -See attach site specific plan sheet (FBC 1609.4.3) Additional Load requirements. Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind pressures, purlins is also be designed for a 200 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. Design Basis: Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor General Requirements: Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acceptance of information shown as correct and obligates himself to any expense, real or implied, arising from their use. A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the contractor and must be submitted to the engineer for approval. The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans prepared -by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall bear no responsibility or liability for the construction of premises and accuracy of the drawings. Foundation and Earthwork: Applicable only when unsuitable soils are encountered. When unsuitable soils are encountered as specified bearing strata, notify owner's representative/engineer. Soil bearing capacity — 2,000 psf Minimum Provide neat excavation for footing and place concrete immediately after excavation and inspection. Pump water from footing excavation if greater than one inch. Compact all fill to 95% ASTM D698 density. Unit soil weight = 105 pcf Internal angle of friction = 30 degrees Coeff. Of friction between footing and soil = 0.5 Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.almninumscreendesign.com ,w r ALUMINUM1DESIGN EMASDAicminuM g. Con.s.9ruction En:gjneerin'g Structural Aluminum: Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice for aluminum design. All aluminum shall be 6005-T5 (E= 10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046" Splicing prohibited without prior approval as to location and type. Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced. Aluminum Protection: Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime -mortar, concrete, or other masonry materials, shall be protected with powder coated or ESP paint or alkali -resistant coatings, such as heavy -bodied bituminous paint or water -white methacrylate lacquer. Screws: Aluminum self -tapping screws shall conform to ASME B 18.6.4 specification. Self —tapping screws shall meet the requirements of ADM J.5 Maximum fastener spacing shall not exceed (3+20t) where "t" is the member thickness in inches. For roofing and -siding connection, use minimum #12 screws for end and side laps spaced at 12" max for side lap - and end lap fasteners shall be no more than 2" from the end of overlapping sheets. For bottom plate and column base, secure with tapcons a minimum embedment of 1 1/8" and 2 '/4" respectively into concrete footer. Bolts: Bolts and other fasteners shall be aluminum, stainless steel, hot -dip or electro-galvanized steel. Double cadmium plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16" larger than the bolt diameter and shall be spaced at a minimum of 2.5 times the bolt diameter with minimum edge distance of 1.5 times the bolt diameter. Bolts shall meet the requirements of ADM J.3 Chair Rails, Purlins & Wind Brace: Chair rails, purlins and wind brace shall conform with the below maximum span length. If the event contractor's specific site plan conflict with the below recommended length, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction. Wind Speed =150 MPH 2 x 2 Chair Rail = 4'-9" 2 x 2 Purlins = 6'-6" 2 x 2 Wind Brace = 4'-3" 2 x 3 (0.125) Wind Brace = 8'-0" 2 x 3 Chair Rail = 6'-9" 2 x 3 Purlins = 6'-9" 2 x 3 Wind Brace = 6'-9" 2 x 4 Wind Brace = 8'-0" Concrete: Conform to ACI 318, latest edition and ACI 301 Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi Exposed chamfer edges shall be'/<" Reinforeine Steel: Conform to ACI 318 and 315, Latest edition All reinforcement steel shall be ASTM A615 Grade 60. Smooth dowels & ties shall be ASTM A185 Welded Wire Fabric shall be ASTM A185 or A82 (Flat sheet). Deformed bar anchors shall be ASTM A496, Grade 70 Cover: Footing 3" Washer: Washers shall be used under bolt heads and under nuts. Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumsereendesign.com ®nALUkf,,1NUMSCREEN Atiminum & Con.struction En.gtnee.ring Y' Hole Alignment: Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal. All chips -- and foreign matter between contacting surfaces shall be removed before assembly. Beams & Upriehts• In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations prior to ordering materials, fabrication and/or construction. 150 MPH PRIMARY BEAMS & COLUMNS -SCREEN & PATIO ROOM ENCLOSURES ROOF PANELS Max Beam Span & Max Column Insulated Roof Beam -Size Spacing Column -Size Max Column -Height Pan Roof Span Span 2 X 3 6'-0" 2 X 3 7'-0" 3" Spans 11'-5" 3" Spans 12'-9" 6" Spans 16'-11" 2-X 4 8'-0" 2X4 7'-0" 2 X 5 9'-6" 1 2 X 5 8'-0" Knee Bracine• Contractor shall provide knee bracing on 45 degree angle pursuant the attach detail sheet that specified size and length requirements. Knee bracing on upright above super gutter intersection shall be connected to upright no more than 6" above the super gutter. Knee brace size shall be a minimum of 2 x 2 for beam span of 15' max; 2 x 3 for 30' max; 2 x 4 for beam span greater than 30'. Purlin• Contractor is required to install purlins spaced to align with column spacing; however, spacing between purlins shall not exceed T-2". Intermediate/Header Beam: Contractor is required to install a minimum 2 x 7 intermediate header beam supported with 3 x 3 column spaced at 10 feet (max) when insulated roof span exceeds 15 feet. Patio Cover: Contractor is required to install insulated roof covering pursuant to the Florida product approval specification. Overhang shall be a maximum of F-0 along the side, 3'4' along- the front and 1/2" along -the front interface between the super gutter and the attached pool cage knee riser wall. Maximum deflection shall be limited to L/80. Edge Distance: Contractor is required to install uprights to provide a 2" minimum clearance from edge of slab and/or footer. Vinyl, tempered glass, and acrylic panels: Vinyl, tempered glass, and acrylic panels shall be removable. Removable panels shall be identified as removable by a decal. The identification decal shall essentially state "Removable panel SHALL be removed when wind speeds exceed 75 mph (34 m/s)." visible when the panel is installed. Michael Thompson, P.E. 947509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com