HomeMy WebLinkAboutSurveyLOT 10
00
FND CAP
C428G)�
�r
PARCEL D-3
PER THE PLAT OF SAVANNAH CLUB
PLAT No. FOUR PLAT BOOK 30, PAGE 15
GOLF
GOUR5E
CR�
1� 1y
FND IR EAST LP1T5 OFF PLAT_R
Q
ti
g• ITIM-
�g0
PORCH
0
BLOCK 75
LOT 9
O
�'
PROPOSED
r
V
O
PROP I
CONCE1
1 STORY
PRE -MANUFACTURE]
a0 �
O
/C -18.4 1
F.F.EL.=19.7'
9y
I EASEMENT
I0 GAP OUT G -1
CUR)
15, &.LUNG
5ETBAOK
<'
C6NGs
BNED
L 10.D'
HP
tf
O
I
00
O
CARPORT O
EL-18.4'
I
O
O
Min
CID
In
z
14.0'
z3)
PROP.
.bP
ABLE
BOX �ELEG.
Co.,
.r DRIVE
ATTT
JAA'BO
5ET CAP
LOT 8
VACANT
C UPY
MIN: SFrraA..,.
CNR
REAI;
LOT 7
'-2' CURB
G�
C 40' PRIVATE R/W) �' Gp 20' PAVEMENT
CURB
SITE PLAN NOTES'
1, COUNTY WATER + SEWER AVAILABLE FOR THIS PARCEL.
2, A DRIVEWAY MAXIMUM SLOPE 15 NOT TO EXCEED A 107" GRADE
3' FIRST FLOOR ELEVATION E5TABU5HED WITHOUT A HEALTH DEPARTMENT PERMIT.
4, PROPOSED DRAINAGE PLAN DE5IGNED TO MEET FLORIDA BUILDING CODE, RESIDENTIAL REQUIITMENTS.CR401.3)
5. ALL SLOPES AROUND THE PROPOSED STRUCTURE ARE NOT TO EXCEED THE MAXIMUM ALLOWABLE SLOPE GRADE OF 41
G- WHEN A CULVERT 15 REQUIRED THE INVERTS ARE TO Be SET BY PUBLIG WORKS DEPARTMENT AND WILL BE DETERMINED AT STAKE AND GRADE.
7- ALL STORMWATER RUNOFF 15 NOT TO IMPACT THE ADJACENT PROPERTIES AND MUST MEET A MINIMUM OF 19. LONGITUDINAL SLOPE OR OTHERWISE ACCEPTED.
81 PLOT PLANS ARE NOT TO BE USED FOR CONSTRUCTION LAYOUT PURPOSES WITHOUT APPROVED BUILDING PERMITS.
*SKETCH NOT A SURVEY•
LEGEND
OF SURVEY
ABBREVIATIONS
LENGTH
A
DELTA ANGLE
L.
A/C
AIR CONDITIONER
#
LIGHT POLE
AVE.
AVENUE
M.
MEASURED
AVG:
AVERAGE
M.H,
MANHOLE
B.B.
BEARING BASE
H.H.W.L.
MEAN HIGH WATER LINE
H.M.
BENCH MARK
MON.
MONUMENT
BLK.
BLOCK
NLD
NAIL L DISK
BLVD.
BOULEVARD
N.
NORTH
C.
CURVE
No.
NUMBER
C.B.
CHORD BEARING
RIC.
NOT INCLUDED
C.B.S.
CONCRETE BLOCK
O.H.W.
OVERHEAD WIRES
STRUCTURE
PG.
PAGE
D.
CHORD DISTANCE
CENTERLINE
P.K.
PARKER KALON NAIL
CLF.
CHAIN LINK FENCE
P.
P.C.
PLAT
POINT OF CURVATURE
ED
C.M.
CHORD DISTANCE
CONCRETE MONUMENT
P.C.P.
PERMANENT CONTROL POINT
C.M.P,
P.T.
CORRUGATED METAL PIPE
POINT OF INTERSECTION
CONC.
CONCRETE
P.L.
PROPERTY LINE
C.R.
COUNTY ROAD
P.M.
POWER METER
CT.
COURT
P.D.B.
POINT OF BEGINNING
C/S
CONCRETE SLAB
P.O.C.
POINT OF COMMENCEMENT
COR.
CORNER
PRC
POINT OF REVERSE CURVE
D.
DEED
P,R.M.
PERMANENT REFERENCE MONUMENT
D.B.
DEED BOOK
PROP.
CUA
PROPOSED
POWER POLE
DEP
DEPARTMENT OF RA➢.
RADIAL OR RADIUS
DIST.
ENVIRONMENTAL PROTECTION
DISTANCE
R/W
RIGHT OF WAY
DNR
DEPARTMENT OF
S.
SEC,
SOUTH
SECTION
DR.
NATURAL RESOURCES
DRIVE
SQ.FT.
SQUARE FEET
E.
EAST
S.R.
STATE ROAD
EASE.
EASEMENT
ST.
STA.
STREET
STATION
ELEC.
ELECTRICAL
STRUC.
STRUCTURE
EL.
ELEVATION
SUB.
SUBDIVISION
E.D.W.
F.F.
EDGE OF WATER
FINISHED FLOOR
T.B.M.
TEMPORARY BENCH MARK
FND.
FOUND
TELE.
TELEPHONE
Yl
FIRE HYDRANT
T.O.B.
TOP OF BANK
F.P.L.
POWER L LIGHT
TOPO.
TOPOGRAPHICAL
I.P.
IRON
IRON PIPE
TR,
TRACT
IRON ROD
TWSP,
TOWNSHIP
INVI.R.
INVERT
U L D
UTILITY L DRAINAGE
/N
F/N
FOUND NAIL
U.R,
UNREADABLE
GOVoT
GOVERNMENT
V.
WEST
GR.
OR,
GRADE
WV
WATER METER
CND.
GROUNDHORIZONTAL
WV
VALVE
WATECOMBINED
HORZ.
HORI20NTAL
'—�
COMBINE➢ LOTS
H.P. HIGH POINT
H.W. HEAD WALL
LEGAL DESCRIPTION, ALL OF LOT 9. BLOCK 75
FAIRWAYS AT SAVANNAH CLUB, REPLAT No.1
ACCORDING TOgHE PLAT THEREOF AS RECORDED IN PLAT BOOK
57. PAGE 43 OF THE PUBLIC RECORDS OF ST. LUGIE GO..
FLORIDA. SAID LANDS LYING IN ST. LUCIE CO.. FLORIDA.
CONTAINING 0.14 ACRES MORE OR LE55
SURVEY NOTES:
1. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR
RIGHTS —OF —WAY AND/OR EASEMENTS OF RECORD.
2. THIS SURVEY IS CERTIFIED ONLY TO THE BELOW
NAMED INDIVIDUALS
3. LEGAL DESCRIPTION SUPPLIED BY CLIENT.
4. SO. FT. OF HOUSE (IF SHOWN) SUPPLIED BY CLIENT.
5. NO STRUCTURES OR UTILITIES THAT ARE BENEATH THE
SURFACE HAVE BEEN LOCATED.
A_ A!_ SET CAPS I_APP EO PSk! MEH 441R ARE TiPPORTED 'N..TH AN 18' LONG #5 REBAR
ALL FOUND CAPS ARE A 5/8" ROD WITH A CAP AS
LABELED ON SURVEY.
ALL FOUND REBAR ARE A 5/8- ROD UNLESS OTHERWISE
NOTED.
7. ALL LOT DIMENSIONS ARE PLAT AND MEASURED UNLESS
OTHERWISE NOTED.
8. BEARING BASE ON NORTH LINE OF LOT 9.
9. ORIGINAL IRC BM: RAY EL.-15.38' NAVD 88.
10. ELEVATIONS (IF SHOWN) HEREON ARE BASED ON N.A.V.D.
(1988), UNLESS OTHERWISE NOTED.
CERTIFIED TO:
SAVANNAH CLUB
G-1
R=975.00' N.R.
L=G4.G4'
A=03°47'55"
CB=NB2°24'00'E
GD=G4.G3'
G-2
R=875.00' N.R.
L=58.01'
A=03°47'55"
GB=SB2°24'01"E
GD=58.00'
THIS SURVEY MAP AND REPORT OR COPIES THEREOF ARE1. SURVEY TYPE: FLOOD ZONE: X
NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SKETCH EFFECTIVE DATE: 12/4/12
DATE: REVISIONS: BY: pNL NO.: 12081CO283 J
SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. ® INDICATES EXISTING ELEVATION
KMA Engineering & Surveying, LLC �� eY. W.E.H. 03/19/21 ADDED SITE SMD
Q INDICATES PROPOSED ELEVATION
DRAB 6Y: T B 6�] INDICATES AS -BUILT ELEVATION
ELEVATIONS ARE FOR CALC.
Consulting Engineers & Surveyors FIELD B�: ^ ^ THERE ARE NOWELLSDR SEPTICS
2345 14th St, Suite 3 Vero Beach, Fl. 32960 PA- N0 NN WITHIN 100' OF PROPERTY UNLESS
SHOWN.
GATE: e1,a— PROPOSED CONTOUR LINE
NN PROPOSED SWALE LINE
g va t Phone: (772) 569-6680 Fax: (772) 770-3446 E-Mail: survey@kmafl.com FI INDICATES LOT DRAINAGE
aAn SCA .�s_.10, ®INDICATES DRAINFIELD
WI LIAM E. HAY UR9T LIVING AREA N/A sO.ft.
Irwos•nes:oxwa >r.Axa a on L 1FAAA>aR CertificaO of Authorization Number: L.B.8351 LOT AREA 6d3 N sD.ft.
s'uRmw RnoEerRwxxox xo use JOB N0: �9-287 LOT SEPTIC TANK