Loading...
HomeMy WebLinkAboutSurveyLOT 10 00 FND CAP C428G)� �r PARCEL D-3 PER THE PLAT OF SAVANNAH CLUB PLAT No. FOUR PLAT BOOK 30, PAGE 15 GOLF GOUR5E CR� 1� 1y FND IR EAST LP1T5 OFF PLAT_R Q ti g• ITIM- �g0 PORCH 0 BLOCK 75 LOT 9 O �' PROPOSED r V O PROP I CONCE1 1 STORY PRE -MANUFACTURE] a0 � O /C -18.4 1 F.F.EL.=19.7' 9y I EASEMENT I0 GAP OUT G -1 CUR) 15, &.LUNG 5ETBAOK <' C6NGs BNED L 10.D' HP tf O I 00 O CARPORT O EL-18.4' I O O Min CID In z 14.0' z3) PROP. .bP ABLE BOX �ELEG. Co., .r DRIVE ATTT JAA'BO 5ET CAP LOT 8 VACANT C UPY MIN: SFrraA..,. CNR REAI; LOT 7 '-2' CURB G� C 40' PRIVATE R/W) �' Gp 20' PAVEMENT CURB SITE PLAN NOTES' 1, COUNTY WATER + SEWER AVAILABLE FOR THIS PARCEL. 2, A DRIVEWAY MAXIMUM SLOPE 15 NOT TO EXCEED A 107" GRADE 3' FIRST FLOOR ELEVATION E5TABU5HED WITHOUT A HEALTH DEPARTMENT PERMIT. 4, PROPOSED DRAINAGE PLAN DE5IGNED TO MEET FLORIDA BUILDING CODE, RESIDENTIAL REQUIITMENTS.CR401.3) 5. ALL SLOPES AROUND THE PROPOSED STRUCTURE ARE NOT TO EXCEED THE MAXIMUM ALLOWABLE SLOPE GRADE OF 41 G- WHEN A CULVERT 15 REQUIRED THE INVERTS ARE TO Be SET BY PUBLIG WORKS DEPARTMENT AND WILL BE DETERMINED AT STAKE AND GRADE. 7- ALL STORMWATER RUNOFF 15 NOT TO IMPACT THE ADJACENT PROPERTIES AND MUST MEET A MINIMUM OF 19. LONGITUDINAL SLOPE OR OTHERWISE ACCEPTED. 81 PLOT PLANS ARE NOT TO BE USED FOR CONSTRUCTION LAYOUT PURPOSES WITHOUT APPROVED BUILDING PERMITS. *SKETCH NOT A SURVEY• LEGEND OF SURVEY ABBREVIATIONS LENGTH A DELTA ANGLE L. A/C AIR CONDITIONER # LIGHT POLE AVE. AVENUE M. MEASURED AVG: AVERAGE M.H, MANHOLE B.B. BEARING BASE H.H.W.L. MEAN HIGH WATER LINE H.M. BENCH MARK MON. MONUMENT BLK. BLOCK NLD NAIL L DISK BLVD. BOULEVARD N. NORTH C. CURVE No. NUMBER C.B. CHORD BEARING RIC. NOT INCLUDED C.B.S. CONCRETE BLOCK O.H.W. OVERHEAD WIRES STRUCTURE PG. PAGE D. CHORD DISTANCE CENTERLINE P.K. PARKER KALON NAIL CLF. CHAIN LINK FENCE P. P.C. PLAT POINT OF CURVATURE ED C.M. CHORD DISTANCE CONCRETE MONUMENT P.C.P. PERMANENT CONTROL POINT C.M.P, P.T. CORRUGATED METAL PIPE POINT OF INTERSECTION CONC. CONCRETE P.L. PROPERTY LINE C.R. COUNTY ROAD P.M. POWER METER CT. COURT P.D.B. POINT OF BEGINNING C/S CONCRETE SLAB P.O.C. POINT OF COMMENCEMENT COR. CORNER PRC POINT OF REVERSE CURVE D. DEED P,R.M. PERMANENT REFERENCE MONUMENT D.B. DEED BOOK PROP. CUA PROPOSED POWER POLE DEP DEPARTMENT OF RA➢. RADIAL OR RADIUS DIST. ENVIRONMENTAL PROTECTION DISTANCE R/W RIGHT OF WAY DNR DEPARTMENT OF S. SEC, SOUTH SECTION DR. NATURAL RESOURCES DRIVE SQ.FT. SQUARE FEET E. EAST S.R. STATE ROAD EASE. EASEMENT ST. STA. STREET STATION ELEC. ELECTRICAL STRUC. STRUCTURE EL. ELEVATION SUB. SUBDIVISION E.D.W. F.F. EDGE OF WATER FINISHED FLOOR T.B.M. TEMPORARY BENCH MARK FND. FOUND TELE. TELEPHONE Yl FIRE HYDRANT T.O.B. TOP OF BANK F.P.L. POWER L LIGHT TOPO. TOPOGRAPHICAL I.P. IRON IRON PIPE TR, TRACT IRON ROD TWSP, TOWNSHIP INVI.R. INVERT U L D UTILITY L DRAINAGE /N F/N FOUND NAIL U.R, UNREADABLE GOVoT GOVERNMENT V. WEST GR. OR, GRADE WV WATER METER CND. GROUNDHORIZONTAL WV VALVE WATECOMBINED HORZ. HORI20NTAL '—� COMBINE➢ LOTS H.P. HIGH POINT H.W. HEAD WALL LEGAL DESCRIPTION, ALL OF LOT 9. BLOCK 75 FAIRWAYS AT SAVANNAH CLUB, REPLAT No.1 ACCORDING TOgHE PLAT THEREOF AS RECORDED IN PLAT BOOK 57. PAGE 43 OF THE PUBLIC RECORDS OF ST. LUGIE GO.. FLORIDA. SAID LANDS LYING IN ST. LUCIE CO.. FLORIDA. CONTAINING 0.14 ACRES MORE OR LE55 SURVEY NOTES: 1. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR RIGHTS —OF —WAY AND/OR EASEMENTS OF RECORD. 2. THIS SURVEY IS CERTIFIED ONLY TO THE BELOW NAMED INDIVIDUALS 3. LEGAL DESCRIPTION SUPPLIED BY CLIENT. 4. SO. FT. OF HOUSE (IF SHOWN) SUPPLIED BY CLIENT. 5. NO STRUCTURES OR UTILITIES THAT ARE BENEATH THE SURFACE HAVE BEEN LOCATED. A_ A!_ SET CAPS I_APP EO PSk! MEH 441R ARE TiPPORTED 'N..TH AN 18' LONG #5 REBAR ALL FOUND CAPS ARE A 5/8" ROD WITH A CAP AS LABELED ON SURVEY. ALL FOUND REBAR ARE A 5/8- ROD UNLESS OTHERWISE NOTED. 7. ALL LOT DIMENSIONS ARE PLAT AND MEASURED UNLESS OTHERWISE NOTED. 8. BEARING BASE ON NORTH LINE OF LOT 9. 9. ORIGINAL IRC BM: RAY EL.-15.38' NAVD 88. 10. ELEVATIONS (IF SHOWN) HEREON ARE BASED ON N.A.V.D. (1988), UNLESS OTHERWISE NOTED. CERTIFIED TO: SAVANNAH CLUB G-1 R=975.00' N.R. L=G4.G4' A=03°47'55" CB=NB2°24'00'E GD=G4.G3' G-2 R=875.00' N.R. L=58.01' A=03°47'55" GB=SB2°24'01"E GD=58.00' THIS SURVEY MAP AND REPORT OR COPIES THEREOF ARE1. SURVEY TYPE: FLOOD ZONE: X NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SKETCH EFFECTIVE DATE: 12/4/12 DATE: REVISIONS: BY: pNL NO.: 12081CO283 J SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. ® INDICATES EXISTING ELEVATION KMA Engineering & Surveying, LLC �� eY. W.E.H. 03/19/21 ADDED SITE SMD Q INDICATES PROPOSED ELEVATION DRAB 6Y: T B 6�] INDICATES AS -BUILT ELEVATION ELEVATIONS ARE FOR CALC. Consulting Engineers & Surveyors FIELD B�: ^ ^ THERE ARE NOWELLSDR SEPTICS 2345 14th St, Suite 3 Vero Beach, Fl. 32960 PA- N0 NN WITHIN 100' OF PROPERTY UNLESS SHOWN. GATE: e1,a— PROPOSED CONTOUR LINE NN PROPOSED SWALE LINE g va t Phone: (772) 569-6680 Fax: (772) 770-3446 E-Mail: survey@kmafl.com FI INDICATES LOT DRAINAGE aAn SCA .�s_.10, ®INDICATES DRAINFIELD WI LIAM E. HAY UR9T LIVING AREA N/A sO.ft. Irwos•nes:oxwa >r.Axa a on L 1FAAA>aR CertificaO of Authorization Number: L.B.8351 LOT AREA 6d3 N sD.ft. s'uRmw RnoEerRwxxox xo use JOB N0: �9-287 LOT SEPTIC TANK