HomeMy WebLinkAboutELECTRIC WATER HEATERI, Residential Electric
I�Catcr
Professional Classic Water Heaters
The new degree of comfort:
Professional Classic® electric water heaters are
engineered for longer life - resistored heating
elements and premium grade anode rod
Efficiency
•.90-.93UFF
• Isolated tank design reduces
ronti>.>rti�[a.h�af IrZSs
• Resistored copper upper element and
resistored Lifeguard'" stainless steel
lower element to prolong anode rod
and tank life
Performance
• FHR: 45 - 67 gallons, based on gallon
capacity
• Recovery: 21 OPH at a 90' F rise
System Sentinel
?ccaeiB`r e-0 1, 5erai,hffd models)
• Exclusive diagnostic system with
glowing LEDs that verify heating
element operation. LEDs pin point the
exact location of functioning or non-
functioning heating elements
Longer Life
• Premium grade anode rod provides
loriCg, -lasting- iarrk" j;11 obit—tion
Features
• Electric junction box located above
heating elements for easy installation
• Over -temperature protector cuts
off power in excess temperature
situations
• Automatic thermostat keeps water at
desired temperature
Plus...
• Rheemglas® tank lining resists
corrosion, and prolongs tank life
•- Everl deer. " se^ ,-cia Win- - u4svi�c-C 311g1 1 LJ
harmful sediment build-up with a
high -velocity spiraling water stream —
helps operating efficiency by saving
energy, money and improving tank Irfe
gr4;
,.
• Enhanced -flow brass drain valve
• Temperature and pressure relief valve
included
• HUD certified for manufactured
hDu.s;ny..and ..; c rod. jar c;ortstr UC.i0j-,
• Low lead compliant
Warranty
• 6-Year limited tank and parts
warranty'
• With ProtectionPlus'' the 6-year limited
tank warranty becomes 10-year
`See Residential Warranty Certificate for complete
h fLarrnaiforl
Units meet or exceed ANSI regdirements and have
been tested according to the AHRI Operatlons
Manual and D.O.E. procedures. Units meet or
exceed the energy efficiency requirements of
NAECA, ASHRAE standard 90, [CC Code and all
state energy efficiency performance criteria.
Professional Classic
ty.y to 55-uaiion Capacities
240 Volt AC/Single Phase
Double and Single Element Models
Electric
See specifications chart on back.
PRINTED IN U.S.A. 05118 WP FORM NO. PROF RH N Rev. 8
R'ce
Water I Residential Electric
ivrofessiertai ii8ssic SffaYer neuters
The new degree of comfort _
Professional Classic® Specifications
DESCRIPTION
FEATURES
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
ENERGY INFO.
T
Y
P
E
NOMINAL
GALLON
CAPACITY
RATED
GALLON
CAPACITY
MODEL
NUMBER
I UEF
FIRSTHOUR
RATING
G.P.H.
RECOVERY
IN G.P.H.
90" F RISE
TANK
HEIGHT
A
HEIGHT TO
WATER CONN.
B
DIAMETER
C
APPROX.
SHIP WT.
(LBS.)
UNIFORM
ENERGY
FACTOR
(UEF)
Tall
30
27
PROE30 T2 RH95r
46
21
47-1/2
50-3/8
19-1/4
92
0.92
Tall
40
36
PROE40 T2 RH95*
55
21
60-3/4
63-5/8
19-1/4
109
0.93
Tall
s0
4S
PROESO T2 Pwgst
69
21
59-6/9
61-5/9
20-114
121
0.03
Tall
55
55
PROE55 T2 RH947
72
21
57
59-3/4
22-1/4
128
0.92
Med.
30
27
PROE30 M2 RH95?
45
21
37-1/2
40-1/2
20-1/4
92
0.90
Med.
40
36
PROE40 M2 RH951
55
21
46-1/4
50-1/2
20-1/4
106
0.93
Mad.
50
45
PROE50 M2 FkkQCt
A?
21
49
60-1/2
29
132
0.93
Short
19.9
-
PROE20 S2 RH
-
21
31-1/2
31-1/2
17
62
-
t Short
28
25
PROE28 S2 RH95
1 45
21
30
1 31-1/8
23
95
1 0.92
Short
30
27
PROE30 S2 RH95 6- ,
46
21
30-1/8
32
19-3/4
95
0.92
Short
36
33
PROE36 92 RH95
46
1 21
91-1/2
93
24-1/4
119
0.02
Short
38
35
PROE38 S2 RH9E 8-
51 121
31-1/2
32-5/8
23
108
0.92
Short
47
43
PROE47 S2 RH95 54 1
21
32
34
26-1/4
149
0.93
Uniform Energy Factor and rated gallon capacity based on Department rf Energy (DOE) requirements.
' System Sentinel optional. Add EC1 to the end of the M del number. System Sentinel not available on single
element models, available on dual element models only System Sentinel not available in excess of 5 kW on
208 V models.
- Water heater dimensions prior to installing insulation blanket that x inu Jed wit', water heater.
• Heaters furnished with standard 240 volt AC, single phase non -simultaneous Ming, and 4500 watt upper and lower heating
elements.
• H heating elements of different wattages than those shown are demanded by zone requirements, they must be
specifically requested.
• Single element models available on special order (6000W max.). Substitute "1" for "2" in model number.
• Special Wiring Options - A limited number of special wiring options are available. Consult factory for price and availability.
• All models equipped with heat traps.
Rocovory -—ttago/2,42 x tomp. riot "F.
Example: 450OW = 21 GPH
2.42 x 90°
Recovery calculations used are based on 4500 watt elements used in nun-simta+aneous operation.
8"
HOT
WATER COLD
CONNECTION60-�WATER
RELIEF VALVE ® CONNECTI
CONNECTION ANODE
ROD
DIA ETER
B
WATER CONNECTIONS ALL 3/4" N.P.T.
In keeping with its policy of cont,'ruous progre:-s and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Pnrkw,)y, Suite 100
riosweil, Georgia 30076 • www.rhet rn.co:n
PRINTED IN U-S.A. 05/1 a — FORM NO. PROE RH N Fiov. e