HomeMy WebLinkAboutPRODUCT APPROVAL9/3/2021 Florida Building Code Online BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts PubfEcations Contact Us BCIS Site Map Links Search bprtI ��� Product Approval rj USER; Public User Product Approval Menu > Product or Application Search > Application Us t > Application Detail • FL # FL6332-R9 k lip Q Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer ICP Adhesives & Sealants, Inc. Address/Phone/Email 12505 NW 44th Street Coral Springs, FL 33065 (B88)774-1419 Ext201 rylipelkonen@icpadhesives.com Authorized Signature Riku Ylipelkonen rylipelkonen@icpadhesives.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roof Tile Adhesives Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/21/2024 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL6332 R9 CO] 2020 01 COI NIEMINEN.pd Standard SSTs] 11 Year 1997 Product Approval Method Method 1 Option D https:/ltloddabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquanCtKft6f%2fM%2b3ax6XpXuonHOZ5EfLMrw%3d 112 49/3/202i Florida Building Code Online Date Submitted 09/29/2020 Date Validated 10/04/2020 Date Pending FBC Approval 10/11/2020 Date Approved 12/15/2020 Summary of Products (-- i FL # Model, Number or Name Description 6332.1 POLYSET AH-160 Dual component expanding polyurethane roof tile adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL6332 R9 II 2020 09 29 FINAL ER POLYSET Approved for use outside HVHZ: Yes AH160 FL6332-R9.p_df Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +n/a/-178 Created by Independent Third Party: Yes Other: 1.) The design pressure limitation in this application Evaluation Reports refers to hip and ridge tiles in one configuration. Refer to Table FL6332 R9 AE 2020 09 29 FINAL ER POLYSET 2 of ER for all hip and ridge tile limitations. 2.) Field tiles are AH160 FL6332-R9.pdf designed based on overturning moment resistance. Refer to Created by Independent Third Party: Yes Table 1 of ER for field the limitations. 3.) Refer to ER Sections 5 for other Limitations of Use. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Coht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund State Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4S5, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click ll=. Product Approval Accepts. ® E3 E Credit Card Safe https://floddabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDquanCtKft6f%2fM°/a2b3ax6XpXuonHOZ5Ef-Mrw%3d 2/2 MIAMI-DADE COUNTY MIAMI DADE - PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) %t%%%.miamidatic.aoi/ewimmc ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyset" AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 17-0322.03 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. M M� NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page I of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves Polyset' AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications Polyset"AH-160 N/A TAS 101 Two component polyurethane foam adhesive ICP Adhesives Foam N :\ Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPack® N/A Dispensing Equipment 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Density @ 73°F ASTM D1622 Compressive Strength ASTM D1621 Tensile Strength ASTM D1623 Water Absorption ASTM D2842 Moisture Vapor Transmission ASTM E96 Dimensional Stability ASTM D2126 Closed Cell Content ASTM D6226 Results 2.1 lbs./ft' 18 PSI Parallel to rise 14 PSI Perpendicular to rise 29 PSI Parallel to rise 7% 2.3 Perms +0.03% Volume Change @ -40' F., 2 weeks -1.1% Volume Change @158°F., 100% Humidity weeks 94% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1 PA TAS 101 12/16/96 25-7438-3 SSTD H -93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11 /02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 NEMO ETC, LLC 4p-ICP-20-SSLAP-0 LB- Physical Properties 12/4/20 R1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 3 of I I INSTALLATION: 1. Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of Polyset® AH-160. 2. Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP Adhesives ProPacko 30 & 100 dispensing equipment only. 7. Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after Polyset® AH-160 has been dispensed. 9. Polyset® AH-160 placement and minimum patty weight shall be in accordance with the'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 20-1124.07 QMIAMMI-D�ADE COUNTY Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # I Nail through plastic cement Paddy (Beneath Tile) (when required) Underlayment 10 in. Battenem s optional Ease Course Fascia 2 in Eave Closure Nail through plastic cement (when required) 1oin.x\ 2 ln.wida Battens optional \\ Paddy (Beneath Tilel I Eave Closure Fascia Nail throug plastic (when equired)h r Paddy (Beneath Tile) Underlayment v loin.v 2 in. wide Battens %\ /optional Y Eave Coune f Fascia Weephole loin tin Easeclosure Drip edge Flat/Low Profile Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cmZ)-23 (148.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile I. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm'-) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 6 of I ADHESIVE PLACEMENT DETAIL # 2 Nail through plastic °cement \Paddy (Beneath Tilel (when required) Underlayment 7 in..\ 21n. / "•. Battens optional ° - Eave Course loin. Fascia 2m / Ear e dosun�'� Nail through plastic cement (when required) .Paddy )Beneath Tile) Underlayment in�2i 2 m. Battens optional 1�' tin. Eave Closure Eave Course - Fascia MIAMI-DADE COUNTY Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm') - 12 (77.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2)- 23 (148.4 cmz) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 20-1I24.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nail through plastic cn (When required) Paddy (Beneath Tile) IUnderlayment Y 7 in.. 2m�. . Battens optional Eave Course Fascia Weephole 16In. Eave closure Drip edge MIAMI•DADE COUNTY ,...r r High Profile / Single Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cmZ)- 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x I" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm') - 19 (122.6 cmZ) square inch adhesive contact with the underside of the tile. NOA No.: 20-1 I24.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Nail through plastic cement Paddy between til es (when requlredl sanens optional / \ • Paddy [under tile) Singlewddy e on top of tile ' axlin. I �\ /,, �•�• Smgkpsd / underti single paddy- onundedaymMt +`2x!In. -. �Easda --Faeetlopue Flat/Low Profile Tile Nail through plastic cement Sing le paddy under tile (when required) Paddy :between West Battens !� / Paddy !under ttlll optional Singleparl on top of tile..__. •�Laaln. i ]xa sin9lepaddyon., un gedaynent/""�` \•� ��y \`. 10 m', 3in. Ent closure Ere Course, Fasda Medium Profile Tile On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x l" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the the for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in (109.7-148.4 cm) of adhesive contact with the underside of the tile 2. Apply a 4" (10 1.6 mm) x 4" (10 1.6 mm) x I " (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in' (51.6-58.1 cm) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: O1/28/21 Page 9 of I l ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nail through plasticcegretrt- Single paddy under the When required) / Paddy lbetween files) Battens /• Optional Padd Iwdertllel y r single ppaaddy ort underiayrren -r 4a6in. _ -\ Single 2141n. paddy top of file-- ' Eave Course �� � Y Easda Weephote loin. 21n. �, Eave dosure Dripedge High Proflle The 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x a/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm') - 11 (71cmZ) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm') - 9 (58.1 cmZ) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 10 of 1 l ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve GS to 70 sq. in. Steep pitch applications In contact with the pan tile. (when required) 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 2S sq. in. contact area. Underlayment Sheathing Eave closure +' (motar shown) Weephole Fascia Board Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave tine. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3l4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (l 29 cm2) - 25 (161.3 cm') square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 20-1124.07 Expiration Date: 05/10/22 Approval Date: 01/28/21 Page 11 of 11