HomeMy WebLinkAboutPRODUCT APPROVAL9/3/2021
Florida Building Code Online
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts PubfEcations Contact Us BCIS Site Map Links Search
bprtI ��� Product Approval
rj USER; Public User
Product Approval Menu > Product or Application Search > Application Us t > Application Detail
• FL # FL6332-R9 k lip Q
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer ICP Adhesives & Sealants, Inc.
Address/Phone/Email 12505 NW 44th Street
Coral Springs, FL 33065
(B88)774-1419 Ext201
rylipelkonen@icpadhesives.com
Authorized Signature Riku Ylipelkonen
rylipelkonen@icpadhesives.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roof Tile Adhesives
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
01/21/2024
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL6332 R9 CO] 2020 01 COI NIEMINEN.pd
Standard
SSTs] 11
Year
1997
Product Approval Method
Method 1 Option D
https:/ltloddabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDquanCtKft6f%2fM%2b3ax6XpXuonHOZ5EfLMrw%3d 112
49/3/202i
Florida Building Code Online
Date Submitted
09/29/2020
Date Validated
10/04/2020
Date Pending FBC Approval
10/11/2020
Date Approved
12/15/2020
Summary of Products
(-- i
FL #
Model, Number or Name
Description
6332.1
POLYSET AH-160
Dual component expanding polyurethane roof tile adhesive
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6332 R9 II 2020 09 29 FINAL ER POLYSET
Approved for use outside HVHZ: Yes
AH160 FL6332-R9.p_df
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +n/a/-178
Created by Independent Third Party: Yes
Other: 1.) The design pressure limitation in this application
Evaluation Reports
refers to hip and ridge tiles in one configuration. Refer to Table
FL6332 R9 AE 2020 09 29 FINAL ER POLYSET
2 of ER for all hip and ridge tile limitations. 2.) Field tiles are
AH160 FL6332-R9.pdf
designed based on overturning moment resistance. Refer to
Created by Independent Third Party: Yes
Table 1 of ER for field the limitations. 3.) Refer to ER Sections 5
for other Limitations of Use.
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Coht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund State
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4S5, F.S. must provide the Department with an email address If they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click ll=.
Product Approval Accepts.
® E3 E
Credit Card
Safe
https://floddabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDquanCtKft6f%2fM°/a2b3ax6XpXuonHOZ5Ef-Mrw%3d 2/2
MIAMI-DADE COUNTY
MIAMI DADE
- PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) %t%%%.miamidatic.aoi/ewimmc
ICP Adhesives and Sealants, Inc.
12505 NW 44" Street
Coral Springs, FL. 33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In
Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyset" AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA 17-0322.03 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
M M�
NOA No.: 20-1124.07
Expiration Date: 05/10/22
Approval Date: 01/28/21
Page I of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves Polyset' AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of
Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do
not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS
127. For use with approved flat, low, and high profile roof tile systems using Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
Polyset"AH-160 N/A TAS 101 Two component polyurethane foam adhesive
ICP Adhesives Foam N :\ Dispensing Equipment
Dispenser RTF1000
ICP Adhesives ProPack® N/A Dispensing Equipment
30 & 100
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of Polyset® AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
Property Test
Density @ 73°F ASTM D1622
Compressive Strength ASTM D1621
Tensile Strength
ASTM D1623
Water Absorption
ASTM D2842
Moisture Vapor Transmission
ASTM E96
Dimensional Stability
ASTM D2126
Closed Cell Content ASTM D6226
Results
2.1 lbs./ft'
18 PSI Parallel to rise
14 PSI Perpendicular to rise
29 PSI Parallel to rise
7%
2.3 Perms
+0.03% Volume Change @ -40' F., 2 weeks
-1.1% Volume Change @158°F., 100% Humidity
weeks
94%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 20-1124.07
Expiration Date: 05/10/22
Approval Date: 01/28/21
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Center for Applied Engineering
#94-060
TAS 101
04/08/94
257818-1 PA
TAS 101
12/16/96
25-7438-3
SSTD H -93
10/25/95
25-7438-4
25-7438-7
SSTD 11-93
11 /02/95
25-7492
SSTD 11-93
12/12/95
Miles Laboratories
NB-589-631
ASTM D 1623
02/01/94
Polymers Division
Trinity Engineering
7050.02.96-1
TAS 114
03/14/96
P36700.04.12
ASTM D 1623
04/18/12
P39740.02.12
TAS 101
02/21/12
TAS 123
Celotex Corp. Testing Services
528454-2-1
TAS 101
10/23/98
528454-9-1
528454-10-1
520109-1
TAS 101
12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1
TAS 101
03/02/99
520109-2-1
NEMO ETC, LLC
4p-ICP-20-SSLAP-0 LB-
Physical Properties
12/4/20
R1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of Polyset® AH-160 roof tile adhesive with their tile
assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 20-1124.07
Expiration Date: 05/10/22
Approval Date: 01/28/21
Page 3 of I I
INSTALLATION:
1. Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance
values with the use of Polyset® AH-160.
2. Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding
Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of Polyset® AH-160
shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance
with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the
roof tile assembly NOA.
3. Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS
120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between
1.0-1.15 (A): 1.0 (B).
6. Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP Adhesives ProPacko 30
& 100 dispensing equipment only.
7. Polyset® AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after Polyset® AH-160
has been dispensed.
9. Polyset® AH-160 placement and minimum patty weight shall be in accordance with the'Placement Details'
herein. Each generic tile profile requires the specific placement noted herein.
NOA No.: 20-1124.07
Expiration Date: 05/10/22
Approval Date: 01/28/21
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
17 grams per bead
edge) 20-25 sq. inches each
bead
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 20-1124.07
QMIAMMI-D�ADE COUNTY Expiration Date: 05/10/22
Approval Date: 01/28/21
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # I
Nail through plastic cement Paddy (Beneath Tile)
(when required)
Underlayment
10 in.
Battenem s optional
Ease Course
Fascia
2 in
Eave Closure
Nail through plastic cement
(when required)
1oin.x\
2 ln.wida
Battens optional
\\
Paddy (Beneath Tilel I
Eave Closure
Fascia
Nail throug plastic
(when equired)h
r
Paddy (Beneath Tile)
Underlayment
v
loin.v
2 in. wide
Battens %\
/optional
Y Eave Coune
f
Fascia
Weephole
loin tin
Easeclosure
Drip edge
Flat/Low Profile Tile
I . Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cmZ)-23 (148.4 cm) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
I. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm') — 23 (148.4 cmZ) square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
I . Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm'-) — 23 (148.4 cm') square inch adhesive
contact with the underside of the tile.
NOA No.: 20-1124.07
Expiration Date: 05/10/22
Approval Date: 01/28/21
Page 6 of I
ADHESIVE PLACEMENT DETAIL # 2
Nail through plastic °cement
\Paddy (Beneath Tilel
(when required)
Underlayment
7 in..\
21n. / "•.
Battens optional ° -
Eave Course
loin.
Fascia
2m /
Ear e dosun�'�
Nail through plastic cement
(when required)
.Paddy )Beneath Tile)
Underlayment
in�2i
2 m.
Battens optional
1�' tin.
Eave Closure
Eave Course - Fascia
MIAMI-DADE COUNTY
Flat/Low Profile Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
— 23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm') - 12 (77.4 cm2) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2)-
23 (148.4 cmz) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 20-1I24.07
Expiration Date: 05/10/22
Approval Date: 01/28/21
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
Nail through plastic cn
(When required)
Paddy (Beneath Tile)
IUnderlayment
Y
7 in..
2m�. .
Battens optional
Eave Course
Fascia
Weephole
16In.
Eave closure
Drip edge
MIAMI•DADE COUNTY
,...r r
High Profile / Single Pan Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cmZ)-
23 (148.4 cmZ) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x I" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm') - 19 (122.6 cmZ) square inch adhesive
contact with the underside of the tile.
NOA No.: 20-1 I24.07
Expiration Date: 05/10/22
Approval Date: 01/28/21
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
Nail through plastic cement Paddy between til es
(when requlredl
sanens optional / \
• Paddy [under tile)
Singlewddy
e on top of tile '
axlin. I �\
/,,
�•�• Smgkpsd
/ underti
single paddy-
onundedaymMt +`2x!In. -.
�Easda
--Faeetlopue
Flat/Low Profile Tile
Nail through plastic cement Sing le paddy under tile
(when required)
Paddy :between West
Battens !� / Paddy !under ttlll
optional
Singleparl
on top of tile..__.
•�Laaln. i ]xa
sin9lepaddyon.,
un gedaynent/""�` \•� ��y
\`. 10 m', 3in.
Ent closure
Ere Course, Fasda
Medium Profile Tile
On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x l" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the the for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in (109.7-148.4 cm) of
adhesive contact with the underside of the tile
2. Apply a 4" (10 1.6 mm) x 4" (10 1.6 mm) x I " (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
pan portion of the tile, closest to the underlock for
the second course tile to be installed. Insure
approximately 8-9 in' (51.6-58.1 cm) of adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 20-1124.07
Expiration Date: 05/10/22
Approval Date: O1/28/21
Page 9 of I l
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
Nail through plasticcegretrt-
Single paddy under the
When required) /
Paddy lbetween files)
Battens /•
Optional
Padd Iwdertllel
y
r single ppaaddy
ort underiayrren
-r 4a6in.
_ -\
Single 2141n.
paddy
top of file--
' Eave Course ��
� Y Easda
Weephote
loin. 21n.
�,
Eave dosure
Dripedge
High Proflle The
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x a/4"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm') - 11 (71cmZ) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm') - 9 (58.1 cmZ) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
NOA No.: 20-1124.07
Expiration Date: 05/10/22
Approval Date: 01/28/21
Page 10 of 1 l
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
1) Place enough adhesive to achieve GS to 70 sq. in. Steep pitch applications
In contact with the pan tile. (when required)
2) Turn covers upside down. Place adhesive in
to 1 in. from outside edge of cover tile.
Then install the tile. Ensure 20 to
2S sq. in. contact area.
Underlayment
Sheathing
Eave closure +'
(motar shown)
Weephole
Fascia Board
Remove top portion of the eave course cover tile. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at eave tine.
Two Piece Barrel - High Profile Tile
Two Piece Barrel (Cap and Pan) Tile
I . Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm2) — 70 (451.6 cm2)
square inch adhesive contact with the underside
of the pan tile.
3. Turn covers upside down exposing the underside
of the tile. Apply a minimum 1" (25.4 mm) x 10"
(254 mm) bead of adhesive directly on the inner
edge of each side of the cover tile. Leave
approximately 3l4" (19 mm) to 1" (25.4 mm)
from the outside edge of the tile, inward, free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20 (l 29 cm2) - 25 (161.3 cm') square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 20-1124.07
Expiration Date: 05/10/22
Approval Date: 01/28/21
Page 11 of 11