Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL SUBMITTAL AFFIDAVITA−2.0FLOOR PLANA−6.0A−7.0A−4.0A−5.0A−3.0WALL SECTIONS / NOTESINTERIOR ELEVATIONSROOF / FRAMING PLANBUILDING ELEVATIONSELECTRICAL PLANCVRA−1.0FOUNDATION PLANINDEX / PROJECT INFORMATIONWALL SECTIONS / NOTESA−6.11/8" ANNEALED3/16" TEMPEREDBUILDING ADDRESS: LOT 102 / BLOCK * / PHASE IIA, MORNINGSIDE COMMUNITY, FT. PIERCE, FLORIDAPRODUCT APPROVAL SUBMITTAL AFFIDAVITSMOOTH STARFIBER−CLASSICOPENING SCHEDULE SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS, & SKYLIGHTS:8068 S.G.D.SLIDING GLASS DOORWINDOW3068IDOPENING BUILDING PERMIT: EXTERIOR SWING DOORPRODUCTMI WINDOWS AND DOORSMI WINDOWS AND DOORSTHERMA−TRUMANUFACTURERMODEL #GLASSDRAWING INDEXATTACHMENT METHODCONTRACTOR:APPROVALPRODUCTPRESSURESDESIGNW/ SDLT.COMPONENTS AND CLADDING WIND PRESSURES PER2020 FLORIDA BUILDING CODE500 AND ABOVE(SQ. FT.)100 TO 499.9USING INTERIOR ZONE COEFFICIENTSAREA OF OPENINGSUSING END ZONE COEFFICIENTSAREA OF OPENINGS(SQ. FT.)50 TO 99.920 TO 49.90 to 19.9−28.7 PSF23.5 PSF/20.6 PSF −22.9 PSF/24.8 PSF26.4 PSF27.6 PSF20.6 PSF23.5 PSF24.8 PSF26.4 PSF27.6 PSF−31.2 PSF−34.5 PSF−37.0 PSF−22.9 PSF−25.8 PSF−27.1 PSF−28.7 PSF−30.0 PSFPRESSUREPRESSURE////DESIGN DESIGN ////500 AND ABOVE100 TO 499.950 TO 99.920 TO 49.90 to 19.9A−6.2WALL SECTIONS / NOTESA−8.0HVAC PLANWAYNE DALTONMODEL 9100<< >>OVERHEAD DOOR16070 OVHD3/16" TEMPEREDSTEEL TRACK BRACKET TO WOOD: 5/16" X 1−5/8" LAG SCREW (FULLY THREADED) HEX WASHER HEAD ONE PER BRACKET − (5)BRACKETS TOTAL PER VERTICAL STEEL TRACKI have reviewed the above product approvalinformation and approved it.Name:________________________________Signature:________________________________Certification Number:________________________________Date:________________________________HEAD: 1/4" X 3−3/4" TAPCONS SPACED 3" FROM CORNERS, 3" & 6" FROM MULLION. JAMBS: 1/4" X 3−3/4" TAPCONS SPACED 3"FROM CORNERS, 14" O.C. MAX. SILL: 1/4" DIA. X 2−1/4" TAPCONS SPACED 3" FROM CORNERS, 3" & 6" FROM MULLION.ALL ANCHORS ARE 3/16" DIA. TAPCONS (1−1/4" MIN. EMBEDMENT)HEAD: SPACED 6" FROM CORNERS, 17" O.C. MAX. JAMBS: SPACED 6" FROM CORNERS, 17" O.C. MAX. SILL: SPACED 6" FROMCORNERS, 17" O.C. MAX.+/− 60.0 PSF (MIN)ALL ANCHORS ARE 3/16" DIA. TAPCONS (1−1/4" MIN. EMBEDMENT)ANCHORS 2" FROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX.1/8" ANNEALEDWINDOWMI WINDOWS AND DOORS+/− 60.0 PSF (MIN)1/8" ANNEALEDWINDOWMI WINDOWS AND DOORS+/− 60.0 PSF (MIN)NOTE: THE CELLULOSE INSULATION TO BE USED COMPLIESWITH THE REQUIREMENTS OF SECTION R302.10 AND MEETSTHE FLAME SPREAD INDEX OF NOT MORE THAN 25 AND THESMOKE-DEVELOPED INDEX OF NOT MORE THAN 450.NOTE: THE WALL AND CEILING FINISHES COMPLIES WITH THEREQUIREMENTS OF SECTION R302.9.1 AND MEETS THEFLAME SPREAD INDEX OF NOT MORE THAN 200 ANDCOMPLIES WITH THE REQUIREMENTS OF SECTION R302.9.2AND MEETS THE SMOKE-DEVELOPED INDEX OF NOT MORETHAN 450.For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s.a. Weathering is "neglible" for concrete as determined from the Weathering Probability Map [Figure R301.2(3)]. The grade of masonry units shall be determinedfrom ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652.b. Reserved.c. Termite infestation per Figure R301.2(6) is "very heavy."d. Wind speed shall be from the basic wind speed map [Figure R301.2(4)]. Wind exposure category shall be determined on a site-specific basis in accordancewith Section R301.2.1.4.e. The outdooe design dry-bulb temperature shall be selected from the columns of 97 1/2-percent values for winter from Appendix D of the Florida Building Code,Plumbing. Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.f. Reserved.g. The applicable governing body shall, by local floodplain floodplain management ordinance, specify (a) the date of the jurisdiction's entry into the National FloodInsurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the Flood Insurance Study and (c) thepanel numbers and dates of all currently effective FIRM and FBFM, or other flood hazard map adopted by the authority having jurisdiction, as amended.h. Reserved.i. Reserved.j. Reserved.k. Reserved.TABLE R301.2(1)CLIMATIC AND GEOGRAPHIC DESIGN CRITERIAGROUNDSNOWLOADWIND DESIGN SEISMICDESIGNCATEGORYSUBJECT TO DAMAGE FROMWINTERDESIGNTEMPICE BARRIERUNDERLAYMENTREQUIREDFLOODHAZARDSAIRFREEZINGINDEXMEANANNUALTEMPN/AN/AN/A N/A N/ASpeed(mph)Topographiceffects (NA)Weathering Frost linedepthTermiteSee Fig. R301.2(4) Negligible VeryHeavyN/Adkfa b cehgij8"x8"x4"GLASS BLOCKMULIA, INC.NOA 15−0916.12 +/− 90.0 PSF (MIN)PROVIDE LADDER REINFORCING & WALL TIES AT ALTERNATE LAYERS, PROVIDE (2) 1/4" DIA. TAPCONS AT EACH WALL TIE WITH1−1/4" MIN. EMBEDMENTSERIES 420185 SHFL17499.2185 SHFL17499.2185 SHFL17499.2ALL ANCHORS ARE 3/16" DIA. TAPCONS (1−1/4" MIN. EMBEDMENT)ANCHORS 2" FROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX.ALL ANCHORS ARE 3/16" DIA. TAPCONS (1−1/4" MIN. EMBEDMENT)ANCHORS 2" FROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX.1/8" ANNEALEDWINDOWMI WINDOWS AND DOORS+/− 60.0 PSF (MIN)ALL ANCHORS ARE 3/16" DIA. TAPCONS (1−1/4" MIN. EMBEDMENT)ANCHORS 2" FROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX.1/8" ANNEALEDWINDOWMI WINDOWS AND DOORS+/− 60.0 PSF (MIN)185 SHFL17499.2185 SHFL17499.2ALL ANCHORS ARE 3/16" DIA. TAPCONS (1−1/4" MIN. EMBEDMENT)ANCHORS 2" FROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX.1/8" ANNEALEDMI WINDOWS AND DOORSFIXED 185FIXED GLASSFL15349.1+/− 60.0 PSF (MIN)ALL ANCHORS ARE #10 WOOD SCREWS (1−1/4" MIN. EMBEDMENT)ANCHORS 6" FROM CORNERS, HEAD& SILL: 18" O.C. MAX., JAMBS: 18" O.C. MAX.COMPONENTS AND CLADDING WIND PRESSURES:ENCLOSEDROOF PITCH: /12(SHINGLES)+/− 0.18PROJECT & CODE DATA*PLANS DESIGNED TO COMPLY WITH THE 2020 FLORIDA BUILDING CODE (7TH EDITION)EXPOSURE: B IMPACT RESISTANT ASSEMBLY:ROOF DEAD LOAD:SHUTTERS:IMPORTANCE FACTOR:INTERNAL PRESSURE COEFFICIENT:OVERHANG: FTMEAN BUILDING HEIGHT: YES1.33 YESX115’TYPE OF CONSTRUCTION: BUILDING DESIGN: ULTIMATE DESIGN WIND SPEED:BUILDING CATEGORY: IINOMINAL DESIGN WIND SPEED:140 MPH124 MPHCBS XNOX17 PSF6(TILE)NOPARTIALLY ENCLOSEDOPENX160 MPHFRAMEX 170 MPHROOF LOAD:TOP CHORD: LIVE LOAD: 20 PSF DEAD LOAD: 10 PSFBOTTOM CHORD: LIVE LOAD: 10 PSF DEAD LOAD: 7 PSF(NON−CONCURRENT)<< >>ALUMINUM SOFFITEXTERIOR SOFFITAMERICAN CONSTRUCTIONMATERIALSFL12019+/− 70.0 PSF (MIN)PROVIDE T−NAILS AT 12" O.C. IN F−CHANNEL SLOT ON MASONRY, PROVIDE TRIM NAILSATTACHED THROUGH FASCIA AT 16" O.C.ASPHALT SHINGLES<< >>CAMBRIDGE ARGALV. ROOFING NAILS, 11 OR 12 GA., WITH AT LEAST 3/8" DIA. HEADS, LONG ENOUGHTO PENETRATE THROUGH PLYWOOD. USE 4 NAILS PER SHINGLE PLACED 6−1/8"ABOVE BUTT EDGE, APPROX. 1" & 13" FROM EACH END & 1/2" ABOVE EACH CUTOUT.FL18355.1TAMKO BUILDINGPRODUCTS, INC.UNDERLAYMENT<< >>30# ASPHALTFL12328.7TAMCO BUILDINGPRODUCTS, INC.SATURATEDORGANINC FELT30# FELT, APPLIED SINGLE FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2", FASTENED WITH 1" ROUNDPLASTIC CAP, METAL CAP NAILS OR NAILS AND TIN TABS ATTACHED TO SHEATHING WITH 2 STAGGERED ROWS IN THE FIELD OFTHE SHEET WITH A MAXIMUM FASTENER SPACING OF 12" O.C., AND 1 ROW AT THE OVERLAPS FASTENED 6" O.C.<< >>STEEL STORMHURRICANE SHUTTERS20 GAUGE GALV. EASTERN METAL SUPPLYPER MANUF.ALL ANCHORS ARE 1/4" DIA. TAPCONS (1−1/4" MIN. EMBEDMENT)SPACING OF ANCHORS PER MANUFACTURER’S SPAN CHARTFL 22270.1PANELSSPAN CHARTS+40.0 − 40.0 PSFFL21135.11+39.2 −43.7 PSFFL9174.8+/− 58.2 PSF (MIN)FL15332.9LISA MOTTRAM FIELD LICENSE NUMBER: 1264695SeeSurvey42CVRSHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEET SHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEETA 1.0 FAMILY ROOMDEN/BEDROOM #4BEDROOM #2BEDROOM #3LIVING ROOMDINING ROOMBREAKFASTKITCHENGARAGEMASTER BEDROOMSHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEETA 2.0 SHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEETA 3.0 SHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEETA 4.0 SHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEETA 5.0 A 6.0SHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEET A 6.1SHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEET A 6.2SHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEET SHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEETA 7.0 SHEETPROJECT NO.LIVINGGARAGELANAIENTRYTOTAL12-10-1917-015-1207-27-21CAYMAN 1763 B2 1763 SQFT387 SQFT118 SQFT38 SQFT2306 SQFTDATE DRAWNDRAWN BY enarRMASTER PLAN REVISIONPLAN REVIEW REVISIONSMCAF I N E H O M E SRENAR BUILDERS, LLC3725 SE OCEAN BLVD., SUITE 101STUART, FLORIDA 34996TELEPHONE 772.692.7800 FAX 772.692.9155CGC 1261228CUBIC VOLUME OFCONDITIONED SPACE =14,104 CUBIC FEETA 8.0