Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department • Building & Code Regulations Division • - 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Savannas Preserve State Park Education Center Addition Project Address: 2541 SE Walton Road, Port Saint Lucie, Florida Permit #: 14 0 3 — 0 0 9 4 Occupancy Type: B Construction Type: VB INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition COPY o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the If above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2010 Edition with 20 12 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. .Risk Category: _I X II _III IV Exposure Category: _B X C _D 4. Design Wind Velocity 17 0 mph _ASD X LRFD End Zone Width: V -0" ft 5. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 61. 3 Zone 2: 106.7 Zone 3: 157.7 Zone 4: 72.6 Zone 5: 89.7 Garage: �a 7. Design Loads: Floor: 80 PSF Roof/Dead: 10 PSF Roof/Live: 20 Balcony: 10 0 PSF Dock: n/a PSF Deck: 100 PSF Stairs: 100 PSF Fence: n/a PSF Railings:200 lbs. any direction 50 plf any direction 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with t1 p ppaicpp)e structural portions of the building codes currently adopted and enforced by St: Lucie County. `%&TS' a jfyjth�t ±it4y�tural elements depicted on these plans provide adequate resistance to the design forces•Sfi�e .......0 •��GENS � Federico Bowen PE#38153, EB5026 ! b 153l�z s Print Name Cert # & Co. Cert Auth. Bowen Engineering Corporation SignDate�� .••'G��'`�: 1528 Vassar Street, Orlando Fl. 32804 Company Name & Address SLCCDV Form'#f*&&12 Rb�d 3/15/12 (1s)