HomeMy WebLinkAboutField Density Test ReportANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 67
REPORTED TO: CAPTEC Engineering, Inc.
CC:
FILECOPY
DATE OF TEST(S): 9/11/2015 PAGE NO: 1 OF 1
TEST NO.
Educational Center, Sidewalk Subgrade on NW Side of Pavilion
MDR
NO.
MOISTURE
CONTENT /o
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
TN of existing sidewalk, going north (retest from 9/9/2015)
1
12.1
110.8
97 `*
0 to -12" SPSW
2
70'N of existing sidewalk, going north (retest from 9/9/2015)
1
12.6
111.5
98 `*
0 to -12" SPSW
3
175'N of existing sidewalk, going north (retest from 9/9/2016)
1
13.2
109.3
96 **
0 to -12" SPSW
i
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: j— ASTM D-2937 W ASTM D-2922 I" ASTM D-2167 l-" ASTM D-1 556
TECHNICIAN: AS REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT IRS = ROADWAY NSSG = NON STABILIZED SUBGRADE
1 D1557 114.2 PCF 10.7 % SBP= SOIL BELOW PAVEMENT TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE BOS = BOTTOM OF STRUCTURE
OTHER: SBSW=Soil Below Sidewalk
ECIEUVE
JAN 13 OECD D
.77 / 03-00_95/
David P. Andre, P.E.
Fla. Reg. No. 53969
rr9n RVTEC,96N'T-f (?LIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
r� r
l
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 66
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 9/10/2015 PAGE NO:
1 OF 1
TEST NO.
Educational Center, Sidewalk Subgrade on NW Side of Pavilion
MDR
NO.
MOISTURE
CONTENT %
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
TN of existing sidewalk, going north (retest from 9/9/2015)
1
14.7
104.5
92 *
0 to -12" SPSW
2
70'N of existing sidewalk, going north (retest from 919/2015)
1
14.7
105.3
92 *
0 to -12" SPSW
3
175'N of existing sidewalk, going north (retest from 9/9/2015)
1
14.8
104.7
92 *
0 to -12" SPSW
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: (J ASTM D-2937 J%► ASTM D-2922 j- ASTM D-2167
j— ASTM D-1 556
TECHNICIAN: AS REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY NSSG = NON STABILIZED SUBGRADE
1 D1557 114.2 PCF 10.7 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOIS = BOTTOM OF STRUCTURE
OTHER: SBSW=Soil Below Sidewalk
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 64
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 9/9/2015 PAGE NO:
1 OF 1
TEST No.
Educational Center, Sidewalk Subgrade on NW Side of Pavilion
MDR
NO.
MOISTURE
CONTENT %
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
3'N of existing sidewalk, going north
1
14.9
104.5
92 *
0 to -12" SPSW
2
70'N of existing sidewalk, going north
1
14.5
106.1
93 *
0 to -12" SPSW
3
115'N of existing sidewalk, going north
1
13.6
111.8
98
0 to -12" SPSW
4
175'N of existing sidewalk, going north
1
15.0
103.7
91 *
0 to -12" SPSW
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: F ASTM D-2937 r%-o ASTM D-2922 J ASTM D-2167
jJ ASTM D-1 556
TECHNICIAN: AS REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT IRS = ROADWAY NSSG = NON STABILIZED SUBGRADE
1 D1557 114.2 PCF 10.7 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: SBSW=Soil Below Sidewalk
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Bittmore Street
Port St. Lucie, Florida 34983
Phone:772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 55
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 8/24/2015 PAGE NO:
1 OF 1
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
Educational Center Northern Parking Lot, 12" Stabilized Subgrade
NO.
CONTENT /o
DENSITY
COMPACTION
LOCATION
1
27.29977 /-80.27269
1
8.4
117.3
100
0 to -12" PSSG
2
27.29970 /-80.27261
1
10.3
116.8
99
0 to -12" PSSG
3
27.29967 /-80.27240
1
8.4
115.9
98
0 to -12" PSSG
4
27.29978 /-80.27231
1
8.2
118.2
100 +
0 to -12" PSSG
5
27.29967 /-80.27219
1
8.7
116.4
99
0 to -12" PSSG
6
27.29969 /-80.27206
1
9.9
116.1
99
0 to -12" PSSG
7
27.29963 /-80.27193
1
8.6
117.0
99
0 to-12" PSSG
8
27.29962 /-80.27276
1
9.0
116.3
99
0 to-12" PSSG
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELD TEST: r ASTM D-2937 f%_0 ASTM D-2922 F-' ASTM D-2167
r ASTM D-1556
TECHNICIAN: SM REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAY = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
1 D1557 117.7 PCF 9.2 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATIGO
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
\ J
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 48
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 8/11/2015 PAGE NO:
1 OF 1
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
Educational Center Entrance Driveway, 12" Stabilized Subgrade
NO.
CONTENT /o
DENSITY
COMPACTION
LOCATION
1
27.29960 /-80.27274
1
8.1
121.3
100 *
0 to -12" PSSG
2
27.29945 /-80.27289
1
7.8
120.2
100 +
0 to -12" PSSG
3
27.29934 /-80.27300
1
9.6
118.2
100 +
0 to -12" PSSG
4
27.29916 /-80.27296
1
10.6
117.6
100
0 to -12" PSSG
5
27.29904 /-80.27302
1
9.8
120.4
100 +
0 to -12" PSSG
6
27.29893 /-80.27299
1
9.2
119.5
100 +
0 to -12" PSSG
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: j` ASTM D-2937 rv— ASTM D-2922 )� ASTM D-2167 (— ASTM D-1 556
TECHNICIAN: SM REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F = SOIL DIRECTLY BELOW FOOTING FS = FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABLIZED SECTION
MDR NO. ASTM MOISTURE PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY
NSSG = NON STABILIZEDSUBGRADE
1 D1557 117.7 PCF 9.2 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
`� vd
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALLREPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHDRZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 44
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 7/21/2015 PAGE NO:
1 OF 1
TEST NO.
Educational Center Sidewalk Subgrade (West side of building, tie-
in to existing sidewalk)
MDR
NO.
MOISTURE
CONTENT %
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
25'S of NW Corner of Bid., CL of sidewalk
1
10.6
100.1
98
0 to -12" SBSW
2
10'S of SW Corner of Bid., CL of sidewalk
2
10.0
112.0
96
0 to -12" SBSW
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: 1' ASTM D-2937 17 ASTM D-2922 l— ASTM D-2167
r ASTM D-1556
TECHNICIAN: RL REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY NSSG = NON STABILIZED SUBGRADE
1 D1557 102.1 PCF 11.9 % SBP = SOIL BELOW PAVEMENT
2 D1657 117 PCF 9.5 % BOP = BOTTOM OF PIPE
TOP = TOP OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: SBSW=Soil Below Sidewalk
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
� I
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 43
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 7/16/2015 PAGE NO:
2 OF 2
TEST NO.
Educational Center Demucked Parking Lot - North Side, from East
End of Parking Lot to 190'W
MDR
NO.
MOISTURE
CONTENT %
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
11
75'W of E. EOP, and 35'N of S. EOP
1
9.3
116.4
99
+4' to +T BOE
12
115'W of E. EDP and 10'N of S. EOP
1
8.9
117.9
100 +
+4' to +3' BOE
13
140'W of E. EOP and 40'N of S. EOP
1
8.5
118.0
100 +
+4' to +3' BOE
14
180'W of E. EOP and 25'N of S. EOP
1
9.6
116.7
100
+4' to +3' BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELD TEST: (' ASTM D-2937 l✓ ASTM D-2922 ASTM D-2167
ASTM D-1 556
TECHNICIAN: BS REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT IRS = ROADWAY NSSG = NON STABILIZED SUBGRADE
1 D1557 117 PCF 9.5 % SBP = SOIL BELOW PAVEMENT
BOP = BOTTOM OF PIPE
TOP = TOP OF PIPE
BOIS = BOTTOM OF STRUCTURE
OTHER: BOE=Bottom of Excavation
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 43
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 7/16/2015 PAGE NO:
1
OF 2
Educational Center Demucked Parking Lot - North Side, from East
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
End of Parking Lot to 190'W
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
25'N of S. EOP, and 113'W of E. EOP
1
7.6
117.3
100 +
+3' to +2' BIDE
2
25'N of S. EDP, and 11 TW of E. EOP (Retest from 7/8/15)
1
9.8
116.2
99 **
+2' to +1' BOE
3
25'N of S. EOP, and 113'W of E. EOP (Retest from 7/8/15)
1
9.4
116.6
100 '"
+1' to 0 BOE
4
20'N of S. EOP and 153'W of E. EOP (Retest from 7/8/15)
1
10.1
118.0
100
+T to +2' BOE
5
20'N of S. EOP and 153'W of E. EOP
1
9.5
116.5
100
+2' to +1' BOE
6
20'N of S. EOP and 153'W of E. EOP
1
9.8
116.9
100
+1' to 0 BOE
7
40'N and 50'W of N/S Parking Lot Joint (Retest from 7/7/15)
1
9.0
116.5
100 *`
+1' to 0 BIDE
8
40'N and 50'W of N/S Parking Lot Joint
1
8.7
117.4
100 +
+2' to +1' BOE
9
40'N of S. EDP and 130'W of E. EOP
1
9.5
116.1
99
+2' to +1' BOE
10
40'N of S. EOP and 130'W of E. EDP
1
9.2
116.4
99
+1' to 0 BIDE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98
PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: r ASTM D-2937 R7 ASTM D-2922 (� ASTM D-2167
j— ASTM D-1556
TECHNICIAN: BS REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO.
ASTM MAX. MOISTURE PSSG = STABILIZERSUBGRADE
PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
1
D1557 117 PCF 9.5 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: BOE=Bottom of Excavation
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 42
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 7/15/2015 PAGE NO:
1 OF 1
Educational Center Demucked Sidewalk Backfill and North Side of
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
Parking Lot
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
50'W and 2'S of existing sidewalk
1
10.6
114.9
98
+3' to +2' BOE
2
50'W and 2'S of existing sidewalk
1
9.8
114.7
98
+4' to +3' BOE
3
71'W and 20'S of existing sidewalk
1
9.7
115.1
98
+5' to +4' BOE
4
71'W and 20'S of existing sidewalk
1
9.8
115.4
99
+6' to +5' BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELD TEST: iy ASTM D-2937 jJ ASTM D-2922 (' ASTM D-2167
1 ASTM D-1 556
TECHNICIAN: RL REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP F = SOIL DIRECTLY BELOW FOOTING
FS = FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
1 D1557 117 PCF 9.5 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: BOE=Bottom of Excavation
S�
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
i
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 40
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 7/14/2015 PAGE NO:
1 OF 1
TEST NO.
Educational Center Demucked Parking Lot Backfill - Northern 1/2,
from 35' to 65' W. of Pavillion and from NE of Pavillion to 45' S.
MDR
NO.
MOISTURE
CONTENT %
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
40'W of Pavillion, 5'S of N. EDP
1
11.4
117.3
100
+1'to 0 BOE
2
60'W of Pavillion, 15'S of N. EOP
1
10.7
116.7
100
+1'to 0 BOE
3
50'W of Pavillion, 25'S of N. EOP
1
10.1
116.9
100
+1'to 0 BOE
4
45'W of Pavillion, 40'S of N. EOP
1
11.2
118.4
100 +
+1' to 0 BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: r ASTM D-2937 I✓ ASTM D-2922 r ASTM D-2167
l� ASTM D-1 556
TECHNICIAN: BS REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP F = SOIL DIRECTLY BELOW FOOTING
FS = FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY NSSG = NON STABILIZED SUBGRADE
1 D1557 117 PCF 9.5 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOIS = BOTTOM OF STRUCTURE
OTHER: BOE=Bottom of Excavation
'1�
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 39
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 7/812015 PAGE NO:
1 OF 1
Educational Center Demucked Sidewalk Backfill - North of North
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
Side of Parking Lot
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
20'E of existing sidewalk, CL of sidewalk
1
9.9
114.3
98
+1' to 0 BOE
2
20'E of existing sidewalk, CL of sidewalk
1
9.1
116.0
99
+2' to +1' BOE
3
35'E of existing sidewalk, CL of sidewalk
1
11.0
114.2
98
+3' to +2 BOE
4
35'E of existing sidewalk, CL of sidewalk
1
11.2
115.1
98
+4' to +3' BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: (— ASTM D-2937 [7 ASTM D-2922 ASTM D-2167
lV ASTM D-1556
TECHNICIAN: RL REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT IRS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
1 D1557 117 PCF 9.5 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP= BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: BOE=Bottom of Excavation
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
l
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 38
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 7/8/2015 PAGE NO:
1 OF 1
TEST NO.
Educational Center Demucked Parking Lot - North Side
MDR
NO.
MOISTURE
CONTENT /e
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
25'N of S. EOP, 113'W of E. EOP
1
14.3
110.3
94 *
+1' to 0 BOE
2
25'N of S. EDP, 113'W of E. EOP
1
13.6
112.0
96 *
+2' to +1' BOE
3
20'N of S. EOP, 153'W of E. EOP
1
13.9
111.0
95 *
+3' to +2 BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY_ MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELDTEST: ASTM D-2937 1; ASTM D-2922 (� ASTM D-2167
r ASTM D-1 556
TECHNICIAN: RL REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP F = SOIL DIRECTLY BELOW FOOTING
FS = FLOOR SLAB SUBGRADE
ASTOPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. TEST METIHOD DEMNSITY MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
CONTENT IRS = ROADWAY NSSG = NON STABILIZED SUBGRADE
1 D1557 117 PCF 9.5 % SBP = SOIL BELOW PAVEMENT
BOP = BOTTOM OF PIPE
TOP = TOP OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: BOE=Bottom of Excavation
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 37
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 7/7/2015 PAGE NO:
1 OF 1
TEST NO.
Educational Center Parking Lot - North Side
MDR
NO.
MOISTURE
CONTENT %
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
40% and 50'W of North/South Joint
1
13.9
101.3
87 *
+1' to 0 BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELD TEST: i- ASTM D-2937 Tv— ASTM D-2922 r ASTM D-2167
i� ASTM D-1 556
TECHNICIAN: RL REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY NSSG = NON STABILIZED SUBGRADE
1 D1557 117 PCF 9.5 % SBP = SOIL BELOW PAVEMENT
BOP = BOTTOM OF PIPE
TOP = TOP OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: BOE=Bottom of Excavation
'�_> r��
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center REPORT NO: 16
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 5/28/2015 PAGE NO: 1
OF 1
Educational Center Parking Lot - Embankment & Demucking
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
Backfill
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
27.29946 80.27280
1
8.9
116.4
99
+2' to +1' BOE
2
27.29957 80.27268
1
7.8
116.9
100
+2' to +1' BOE
3
27.29943 80.27248
1
8.6
115.9
99
+2' to +1' BOE
4
27.29953 80.27235
1
8.1
115.2
98
+2' to +1' BOE
5
27.29942 80.27221
1
9.0
115.1
98
+2' to +1' BIDE
6
27.29952 80.27209
1
7.9
115.8
99
+2'to+1'BOE
7
27.29947 80.27192
1
8.2
115.5
99
+2'to+1'BOE
8
27.29942 80.27223
1
9.3
116.0
99
+2'to+1'BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: i✓ ASTM D-2937 (- ASTM D-2922 r ASTM D-2167 { - ASTM D-1 556
TECHNICIAN: SM REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA
PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM• MOISTURE PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
1 D1557 117 PCF 9.5 % SBP = SOIL BELOW PAVEMENT TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: BOE: Bottom of Excavation (Demucking)
Peter G. Andersen, P.E.
Fla. Reg. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHOAOZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 15
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 512812015 PAGE NO:
1 OF 1
Educational Center Parking Lot - Embankment & Demucking
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
Backfill
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
27.29946 80.27280
1
10.9
115.0
98
+1' to 0 BOE
2
27.29957 80.27268
1
10.5
116.1
99
+V to 0 BOE
3
27.29943 80.27248
1
10.8
115.6
99
+V to 0 BOE
4
27.29953 80.27235
1
10.5
116.4
99
+V to 0 BOE
5
27.29942 80.27221
1
9.9
116.3
99
+V to 0 BOE
6
27.29952 80.27209
1
10.7
115.2
98
+1' to 0 BOE
7
27.29947 80.27192
1
9.4
116.1
99
+1' to 0 BOE
8
27.29942 80.27223
1
10.0
114.7
98
+V to 0 BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: F,/_ ASTM D-2937 I- ASTM D-2922 I ASTM D-2167 (- ASTM D-1 556
TECHNICIAN: SM REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F = SOIL DIRECTLY BELOW FOOTING FS = FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
ASTM MAX.
MDR NO. MOISTURE PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
TEST METHOD DENSITY
CONTENT RS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
1 D1557 117 PCF 9.5 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: BOE: Bottom of Excavation (Demucking)
C'
Peter G. Andersen, P.E.
Fla. Reg. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZAnON
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 14
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 5/28/2015 PAGE NO:
1 OF 1
Educational Center Parking Lot - Embankment & Demucking
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
Backfill
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
27.29946 80.27280
1
10.2
116.1
99
0 to -12" BIDE
2
27.29957 80.27268
1
8.9
116.8
100
0 to -12" BOE
3
27.29943 80.27248
1
9.6
116.3
99
0 to -12" BOE
4
27.29953 80.27235
1
10.3
115.8
99
0 to -12" BOE
5
27.29942 80.27221
1
10.6
116.3
99
0 to -12" BOE
6
27.29952 80.27209
1
9.4
116.5
100
0 to -12" BOE
7
27.29947 80.27192
1
10.6
115.6
99
0 to -12" BOE
8
27.29942 80.27223
1
10.0
115.9
99
0 to -12" BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: ASTM D-2937 (� ASTM D-2922 (` ASTM D-2167
I " ASTM D-1 556
TECHNICIAN: SM REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
ASTM
MDR NO. MOISTURE PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
TEST METHOD D NSITY
CONTENT IRS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
1 D1557 117 PCF 9.5 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: BOE: Bottom of Excavation (Demucking)
r
Peter G. Andersen, P.E.
Fla. Reg. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
1
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects FILE NO: 14-181
Savannas State Preserve Education Center REPORT NO: 5
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 4/14/2015 PAGE NO: 1 OF 1
TEST NO.
Sidewalk Subgrade
MDR
NO.
MOISTURE
CONTENT %
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
5'W of East End, CL of Sidewalk
1
9.5
107.2
98
+3' to +2' BOE
2
30'W of East End, CL of Sidewalk
1
10.2
106.3
97
+3' to +2' BOE
3
60'W of East End, CL of Sidewalk
1
9.8
106.7
98
+3' to +2' BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: { ASTM D-2937 l✓ ASTM D-2922 J" ASTM D-2167 l- ASTM D-1 556
TECHNICIAN: SM REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP F = SOIL DIRECTLY BELOW FOOTING FS = FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY NSSG = NON STABILIZED SUBGRADE
1 D1557 109.4 PCF 10.6 % SBP = SOIL BELOW PAVEMENT TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE BOS = BOTTOM OF STRUCTURE
OTHER: BOE: Bottom of Excavation (Demucking)
Peter G. Andersen, P.E.
Fla. Reg. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center REPORT NO: 4
REPORTED TO: CAPTEC Engineering, Inc.
CC:
DATE OF TEST(S): 411W2015 PAGE NO: 1
OF 1
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
Sidewalk Subgrade (Eastern 80 feet - Demuck Backfill)
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
30'W of East End, CL of Sidewalk
1
8.5
106.3
97
+1' to 0 BOE
2
65'W of East End, CL of Sidewalk
1
8.3
105.8
97
+1' to 0 BOE
3
5'W of East End, CL of Sidewalk
1
9.2
106.6
97
+1' to 0 BOE
4
30'W of East End, CL of Sidewalk
1
8.9
107.1
98
+2' to +1' BOE
5
55'W of East End, CL of Sidewalk
1
8.6
105.9
97
+2' to +1' BOE
6
10'W of East End, CL of Sidewalk
1
8.0
106.3
97
+2' to +1' BOE
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: r- ASTM D-2937 1W ASTM D-2922 iW ASTM D-2167 I` ASTM D-1556
TECHNICIAN: SM REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP F = SOIL DIRECTLY BELOW FOOTING
FS = FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA
PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX.MOISTURE PSSG = STABILIZED SUBGRADE
PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT IRS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
1 D1557 109.4 PCF 10.6 % SBP= SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER: BOE: Bottom of Excavation (Demucking)
Peter G. Andersen, P.E.
Fla. Reg. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
F-C
ANOANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
JAN 1 1 2016 Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
Public Works www.aaceinc.com
St. Lucie County, FL
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects FILE NO: 14-181
Savannas State Preserve Education Center REPORT NO: 2
REPORTED TO: CAPTEC Engineering, Inc.
CC: PERMIT NO: 1403-0094
DATE OF TEST(S): 4/7/2015 PAGE NO: 1 OF 1
TEST NO.
Sidewalk Subgrade (Excl. Eastern 80 feet)
MDR
NO.
MOISTURE
CONTENT %
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
West 113, CL of Sidewalk
1
10.5
101.3
99
0 to -12" SBSW
2
Central 1/3, CL of Sidewalk
1
9.8
100.8
99
0 to -12" SBSW
3
East 1/3, CL of Sidewalk
1
9.5
101.9
100
0 to -12" SBSW
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: ASTM D-2937 17 ASTM D-2922 r ASTM D-2167 j— ASTM D-1556
TECHNICIAN: SM REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS = ROADWAY NSSG = NON STABILIZED SUBGRADE
1 D1557 102.1 PCF 11.9 % SBP = SOIL BELOW PAVEMENT TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE BOS = BOTTOM OF STRUCTURE
OTHER: SBSW: Soil Below Sidewalk
Peter G. Andersen, P.E.
Fla. Reg. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
573 SW Biltmore Street
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Crosstown Pkwy Mitigation Plan Projects
FILE NO: 14-181
Savannas State Preserve Education Center
REPORT NO: 3
REPORTED TO: CAPTEC Engineering, Inc.
PERMIT NO: 1403-0094
CC:
DATE OF TEST(S): 4/8/2015 PAGE NO:
1 OF 1
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO.
Deck FootingSub g rade, East Side
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
1st Row, 1st Footing from North
1
9.4
101.3
99
0 to -12" F
2
1 st Row, 3rd Footing from South
1
9.2
100.5
98
0 to -12" F
3
2nd Row, 3rd Footing from North
1
10.7
101.8
100
0 to -12" F
4
2nd Row, 4th Footing from South
1
10.2
101.2
99
0 to -12" F
5
2nd Row, Southernmost Footing
1
10.2
100.9
99
0 to -12" F
6
3rd Row, 2nd Footing from South
1
9.3
101.5
99
0 to -12" F
7
3rd Row, 5th Footing from South
1
9.5
101.7
100
0 to -12" F
8
3rd Row, Northernmost Footing
1
10.8
102.0
100
0 to -12" F
* DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELD TEST: r ASTM D-2937 I-V ASTM D-2922 J_ ASTM D-2167
JASTM D-1 556
TECHNICIAN: SM REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F =SOIL DIRECTLY BELOW FOOTING
FS =FLOOR SLAB SUBGRADE
OPTIMUM GA = SOIL IN GENERAL COMPACTED
AREA PAV = SOIL BELOW STABILIZED SECTION
MDR NO. ASTM MAX. MOISTURE PSSG =STABILIZED SUBGRADE
PB = PAVEMENT BASE
TEST METHOD DENSITY CONTENT RS= ROADWAY
NSSG = NON STABILIZED SUBGRADE
1 D1557 102.1 PCF 11.9 % SBP = SOIL BELOW PAVEMENT
TOP = TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
Peter G. Andersen, P.E.
Fla. Reg. No. 57956
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.