Loading...
HomeMy WebLinkAboutNOA; Hardiplank, Cemplank, Hardipanel, Cempanel, Hardisoffit and CemsoffittM I A M 4DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) James Hardie Building Product, Inc. 10901 Elm Avenue Fontana, CA 92337 MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STRF.FT, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone. DESCRIPTION: Hardiplank, Cemplank, Hardipankl, Cempanel, Hardisoffit and Cemsoffitt APPROVAL DOCUMENT: Drawing No. HPNL-8X, HPLK-4X8 & HSOFFTT-8X, titled "Hardipane & Cempanel; Hardiplank & Cemplank; Hardisoffit & Cemsoffit Installation Details", sheets 1 through 3 with no revisions, prepared, signed and sealed by Ronald Ogawa, P.E., dated 04/02/04, bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination andremoval of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 02-0729.02 and, consists of this page, evidence page as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. n NOA No 07-0418.04 a Expiration Date: May 01, 2012 Approval Date: May 31, 2007 Page 1 James Hardie Building Products, Inc. NOTICE OF ACCEPTANCE: EVIDENCE PAGE A DRAWING (submitted under NOA No. 02-0729.02) 1. Drawing prepared by James Hardie Building Products, Inc. titled "Hardipanel & Cempanel; Hardiplank & Cemplank; Hardisoffit & Cemsoffit Installation Details", drawing No HPNL-8X, HPLK-4X8 & HSOFFIT-8X, dated 04/02/04, with no revisions, signed and sealed by R. L. Ogana, PE. B TEST (submitted under NOA No. 02-0729.02) Laboratory Report Test Date Signature 1. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves PE. 2. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves PE. 3. ATI 16423-3 PA 202 & 203 03/18/96 A. N. Reeves PE. C QUALITY ASSURANCE 1. Building Code Compliance Office. D MATERIAL CERTIFICATION (submitted under NOA No. 02-0729.02) 1 Standard Compliance (ASTM C-1185) issued by ETL Testing Laboratories on 05/09/95 signed by D. K. Tucker, PE. 2 Evaluation Report NER-405 issued by National Evaluation Service, Inc. on 01101/93, with no signature. E STATEMENT (submitted under NOA No. 02-0729.02) 1. No change letter issued by James Hardie Building Products, Inc. issued on 02/16/99, signed and by J. L Mulder. 2. Power of Attorney and Appointment of Domestic Representative, signed by P. Shafron on 04/17/02, Assignment and Memorandum of Assignment signed by T. P. Dolmans on 04/16/02 and Assignment for the trade marks of Cemplank, Cempanel and Cemsoffit to the Assistant Commissioner for Trademarks signed by V. Lester and P. Shafron on 04/18/02. E OTHERS 1. No change letter issued by James Hardie Building Products, Inc. issued on 04/02/07, signed and sealed by Chad Diercks, Technical Services Manger. 2. Engineer of record letter issued by Ronald Ogawa & Associates, Inc., dated April 3, 2007, signed and sealed by Ronald I.Ogawa, P.E. IV/Carlos M. Utrera, P.E. roduct Control Examiner NOA No 07-0418.04 Expiration Date: May 01, 2012 Approval Date: May 31, 2007 E-1 WALL LENGTH �B WALL II II II II II II I II II II II II II II II II i I II II II II II IGHT II II II II II II II II II II II I II II II II II II II II II — — — — — — — _ J L — ` B STUDS 16' O.C. ' DETAIL A HARDIPANEL & CEMPANEL SIDING INSTALLATION DETAILS The panels are applied vertically, avoiding horizontal ,Joints, over 5/8' (5 ply) APA rated plywood supported by a minimum of 2'x4' wood studs or 20 ga, x 3 5/8' x 1 3/8' steel studs spaced a maximum of 16' o.c. When installed on Wood studs panels shall be fastened with 6d x 2' long galvanized box nails] on steel studs It shall be fastened with #8 x 1 5/8' x 0.315' corrosion resistance H.D. ribbed buggle screws e— STUDS (METAL _ fasteners s a e p ace o� c, around die perimeter of OR WOOD) - the panel and Intermediate studs, driven -through the plywood sheathing into the studs. AIL Joints shall be over studs. Nalls and screws shall have a minimum edge distance of 3/8' and a minimum clearance of 2' from the corners. 5/8' PLYWOOD SHEATHING SHALL BE ATTACHED TO THE STUDS IN ACCORDANCE TO FLORIDA BUILDING CODE, WITH ANOTHER SET OF NAILS OR SCREWS AS UNDERLINED ABOVE. DETAIL A DESCRIPTION Hardlpanel & Cempanel siding materlal Is a non asbestos fiber cement product tested In accordance with ASTM C-1185 and meeting the requirements of the Florldo Budding Code. r. •- PANEL DIMENSIONS Width Length Thickness 48' 819,10, 5/16' DESIGN PRESSURE RATING Installation Design Pressure \'e Wood frame -76 PSF ;.. Metal frame -104 PSF NOTES 1) ALL INSTALLATION SHALL BE DONE IN CONFORMANCE WITH THIS NOTICE OF ACCEPTANCE, THE MANUFACTURER'S INSTALLATION RECOMMENDATIONS, AND THE APPLICABLE SECTIONS OF THE FLORIDA BUILDING CODE. 2) STUDS OF METAL OR WOOD WHERE HARDIPANEL & CEMPANEL WILL BE INSTALLED SHALL BE DESIGNED BY AN ENGINEER OR ARCHITECT PER THE F.B,C. AND THE REQUIREMENTS OF THIS N.O.A. SECTION B—B PRO^i L'7' R4'h'FWZi3 -FASTENER :�:�cncnwi Oivci HARDIPANEL & CEMPANEL SIDING 7 WATERPR❑OFING PER 2121 .6.2.1 ❑F F,B.C, 5/8' PLYWOOD SHEATHING ...., s-dm Flcrrids R� Pik Dirbba HI WALL LENGTH I II �� II II II 11 II II II II tALL IGHT I II �� II II II II II II II II II II II II �� B STUDS 16' O.C. DETI HARDIPLANK & CEMPLANK SIDING INSTALLATION DETAILS The planks are applled horizontally commencing from the bottom course of a wall With 1 1/4' wide laps of top of the plank. The optional PVC cover molding 1 5/8' wide Is applied to the bottom plate under the bottom plank course. The vertical joints must be over framing members, Optional PVC butt joints inserts ore used for on -stud jointing. The planks are to be Installed over 5/8' (5 ply) APA rated plywood supported by a minimum of 2'x4' wood studs or 20 ga. x 3 5/8' x 1 3/8' steel studs spaced a STUDS (METAL maximum of 16' o.c. The siding shall be fastened through over ❑R WOOD) lapping planks with 8d x 2 1/2' longal231 anized box nails over Wood studs or with #8 x 2 1/4' ton x 0,3 5' corros on resistance H.D. ribbed be screws over steel studs, he fasteners sha t be placed In theuglaver-lapping area 58' o.c, vertically and 16' o c. horizontal( Into the studs through the 5/8' plywood sheathing. dIA since of 3/4' from the edges shall always be observed. 5/8' PLYWOOD SHEATHING SHALL BE ATTACHED TO THE STUDS IN ACCORDANCE TO FLORIDA BUILDING CODE, WITH ANOTHER SET OF NAILS OR SCREWS AS UNDERLINED ABOVE. DETAIL DESCRIPTION Hardiplank & Cemplank siding material is a non asbestos fiber cement product tested In accordance with ASTM C-1185 and meeting the requirements of the Florida Building Code. r, . PLANK DIMENSIONS Width Length Thickness 59 1/2' 12 & 14' 5/16' DESIGN PRESSURE RATING 1 Installation Design Pressure V Wood frame -92 PSF Metal frame -92 PSF NOTES I) ALL INSTALLATION SHALL BE DONE IN CONFORMANCE WITH THIS NOTICE OF ACCEPTANCE, THE MANUFACTURER'S INSTALLATION RECOMMENDATIONS, AND THE APPLICABLE SECTIONS OF THE FLORIDA BUILDING CODE, 2) STUDS OF METAL OR WOOD WHERE HARDIPLANK & CEMPLANK WILL BE INSTALLED SHALL BE DESIGNED BY AN ENGINEER OR ARCHITECT PER THE F.B.C. AND THE REQUIREMENTS OF THIS N.O.A. SECTI❑N B—B PRODUCT RFTIEM 5/8' PLYWOOD Er;;r.::::-,• AIL SHEATHING 12 By WATERPROOFING " 'odancoahw PER 21 L1.6.Z.1 ❑ F F.B.C. NAIL OR SCREW RDIPLANK CEMPLANK SIDING 7RO:Y,:; ; RFVYMi:'P dm>nc iF:rnL r«« _ M1aa1 awk Hub" Cwpv) Chiliad JAMES HARDIE 10901 ELM AVENUE BUILDING PRODUCTS - USA FUNTANA, CA 92337 RESEIkCH & 0EIIIOPIIEV CUM 909-356-6300 FAX. 909 427-0634 This drawing and the copyright therein are the DA ��' 04/02/2004 property of the above wnpany and accordlnoty the dra*hg oust not be copied or reproducedIDG �: HPLK-4X8 In any material Form IM7 NO.: 2/3 'HARDIPLANK® & CEMPLANK® sr NTS SOFFIT WIDTH SOFFIT LENTGH DETAIL A SECTION B—B DESCRIPTION Hardisoffit & Cemsoffit panels material Is a non asbestos fiber cement product tested In accordance with ASTM C-1185 and ' meeting the requirements of the Florida Building Code. ` SOFFIT DIMENSIONS \ Width Length Thickness , X` <48' 8,9,10' 1/4' & 5/16' DESIGN PRESSURE RATING Installation Design Pressure Wood frame t53 PSF Metal frame t 53 PSF NOTES 1) ALL INSTALLATION SHALL BE DONE IN CONFORMANCE WITH THIS NOTICE OF ACCEPTANCE, THE MANUFACTURER'S INSTALLATION RECOMMENDATIONS, AND THE APPLICABLE SECTIONS OF THE FLORIDA BUILDING CODE. 2) TRUSS OF METAL OR WOOD WHERE B TRUSSES 16' O.C. HARDISOFFIT & CEMSOFFIT WILL BE INSTALLED SHALL BE DESIGNED BY AN ENGINEER OR ARCHITECT PER THE DETAIL A F.B.C. AND THE REQUIREMENTS OF THIS eoc,=.`evcssa N.O.A. PRODUCT RF.YEWED alda the FlwW . :.02-0 190 "•: TRUSSES (METAL<:•..•-•..r.--o �tt'.:+,v:: (•per. — �4 i',:y:":iS, O HARDISOFFIT & CEMSOFFIT PANEL INSTALLATION DETAILS OR WOOD) Es -�� 2 Miami C� The soffit panels are to be Installed over minimum 2'x4' wood Dy myk"0O Joists or 20 ga. x 3 5/8' x 1 3/8' steel ,Joists spaced a maximum Mla de Pmdoetciau%a of 16' o,c. When Installed on wood ,Joists Hardisoffit shall be ° fastened with Gd x 2' long galvanized box nallsl on steel studs it shall be fastened with #8 x 1 1/4' x 0,315' corrosion JAMES HARDIE ELM H AVE 1D9D1 10901FONTCA 9 resistance H.D. ribbed bugle screws. The fasteners shall be BUILDING PRODUCTS - USA 9D9-356-6300 placed 4' o.c. around the perimeter of the panel and RBEVICN & DEVE WlI Nf COM FAX- 909-427-1 Intermediate studs, Nails and screws shall have a minimum edge HARDIS❑FFIT This drawing and the copyright therein are the DALE: 04/02, distance of 3/8' and a minimum clearance of 2' from corners. & CEMS❑FFIT property of the above company and accordigly aRc ND.: PANEL the dr.*Ing oust not be copied or reproduced HSOFF In any material form Whatsoever. XLT .: 3/3 FASTENER mte UADnTGr1CCTTdb o rc-mcn[-CTTdb sAu: AITT