HomeMy WebLinkAboutNOA; Hardiplank, Cemplank, Hardipanel, Cempanel, Hardisoffit and CemsoffittM I A M 4DADE
BUILDING CODE COMPLIANCE OFFICE (BCCO)
PRODUCT CONTROL DIVISION
NOTICE OF ACCEPTANCE (NOA)
James Hardie Building Product, Inc.
10901 Elm Avenue
Fontana, CA 92337
MIAMI-DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
140 WEST FLAGLER STRF.FT, SUITE 1603
MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and
accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where
allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone.
DESCRIPTION: Hardiplank, Cemplank, Hardipankl, Cempanel, Hardisoffit and Cemsoffitt
APPROVAL DOCUMENT: Drawing No. HPNL-8X, HPLK-4X8 & HSOFFTT-8X, titled "Hardipane &
Cempanel; Hardiplank & Cemplank; Hardisoffit & Cemsoffit Installation Details", sheets 1 through 3 with no
revisions, prepared, signed and sealed by Ronald Ogawa, P.E., dated 04/02/04, bearing the Miami -Dade County
Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade
County Product Control Division.
MISSILE IMPACT RATING: Large and Small Missile Impact
LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination andremoval of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA # 02-0729.02 and, consists of this page, evidence page as well as approval document
mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
n
NOA No 07-0418.04
a Expiration Date: May 01, 2012
Approval Date: May 31, 2007
Page 1
James Hardie Building Products, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE PAGE
A DRAWING (submitted under NOA No. 02-0729.02)
1. Drawing prepared by James Hardie Building Products, Inc. titled "Hardipanel &
Cempanel; Hardiplank & Cemplank; Hardisoffit & Cemsoffit Installation Details",
drawing No HPNL-8X, HPLK-4X8 & HSOFFIT-8X, dated 04/02/04, with no revisions,
signed and sealed by R. L. Ogana, PE.
B TEST (submitted under NOA No. 02-0729.02)
Laboratory Report
Test
Date
Signature
1. ATI-16423-1
PA 202 & 203
03/18/96
A. N. Reeves PE.
2. ATI 16423-2
PA 202 & 203
03/18/96
A. N. Reeves PE.
3. ATI 16423-3
PA 202 & 203
03/18/96
A. N. Reeves PE.
C QUALITY ASSURANCE
1. Building Code Compliance Office.
D MATERIAL CERTIFICATION (submitted under NOA No. 02-0729.02)
1 Standard Compliance (ASTM C-1185) issued by ETL Testing Laboratories on 05/09/95
signed by D. K. Tucker, PE.
2 Evaluation Report NER-405 issued by National Evaluation Service, Inc. on 01101/93,
with no signature.
E STATEMENT (submitted under NOA No. 02-0729.02)
1. No change letter issued by James Hardie Building Products, Inc. issued on 02/16/99,
signed and by J. L Mulder.
2. Power of Attorney and Appointment of Domestic Representative, signed by P. Shafron
on 04/17/02, Assignment and Memorandum of Assignment signed by T. P. Dolmans on
04/16/02 and Assignment for the trade marks of Cemplank, Cempanel and Cemsoffit to
the Assistant Commissioner for Trademarks signed by V. Lester and P. Shafron on
04/18/02.
E OTHERS
1. No change letter issued by James Hardie Building Products, Inc. issued on 04/02/07,
signed and sealed by Chad Diercks, Technical Services Manger.
2. Engineer of record letter issued by Ronald Ogawa & Associates, Inc., dated April 3,
2007, signed and sealed by Ronald I.Ogawa, P.E.
IV/Carlos M. Utrera, P.E.
roduct Control Examiner
NOA No 07-0418.04
Expiration Date: May 01, 2012
Approval Date: May 31, 2007
E-1
WALL LENGTH
�B
WALL
II II II II II
II I II II II II
II II II II II
i I II II II II II
IGHT
II II II II II
II II II II II
II I II II II II
II II II II II
— — — — — — — _ J L — `
B STUDS 16' O.C. '
DETAIL A
HARDIPANEL & CEMPANEL SIDING INSTALLATION DETAILS
The panels are applied vertically, avoiding horizontal ,Joints,
over 5/8' (5 ply) APA rated plywood supported by a minimum
of 2'x4' wood studs or 20 ga, x 3 5/8' x 1 3/8' steel studs
spaced a maximum of 16' o.c. When installed on Wood studs
panels shall be fastened with 6d x 2' long galvanized box
nails] on steel studs It shall be fastened with #8 x 1 5/8' x
0.315' corrosion resistance H.D. ribbed buggle screws e— STUDS (METAL _
fasteners s a e p ace o� c, around die perimeter of OR WOOD)
-
the panel and Intermediate studs, driven -through the plywood
sheathing into the studs. AIL Joints shall be over studs. Nalls
and screws shall have a minimum edge distance of 3/8' and
a minimum clearance of 2' from the corners.
5/8' PLYWOOD SHEATHING SHALL BE ATTACHED TO THE STUDS IN
ACCORDANCE TO FLORIDA BUILDING CODE, WITH ANOTHER SET OF
NAILS OR SCREWS AS UNDERLINED ABOVE.
DETAIL A
DESCRIPTION
Hardlpanel & Cempanel siding materlal Is a non
asbestos fiber cement product tested
In accordance with ASTM C-1185 and
meeting the requirements of the
Florldo Budding Code. r. •-
PANEL DIMENSIONS
Width Length Thickness
48' 819,10, 5/16'
DESIGN PRESSURE RATING
Installation Design Pressure \'e
Wood frame -76 PSF ;..
Metal frame -104 PSF
NOTES
1) ALL INSTALLATION SHALL BE DONE IN CONFORMANCE
WITH THIS NOTICE OF ACCEPTANCE, THE MANUFACTURER'S
INSTALLATION RECOMMENDATIONS, AND THE APPLICABLE
SECTIONS OF THE FLORIDA BUILDING CODE.
2) STUDS OF METAL OR WOOD WHERE HARDIPANEL &
CEMPANEL WILL BE INSTALLED SHALL BE DESIGNED BY
AN ENGINEER OR ARCHITECT PER THE F.B,C. AND THE
REQUIREMENTS OF THIS N.O.A.
SECTION B—B
PRO^i L'7' R4'h'FWZi3
-FASTENER :�:�cncnwi
Oivci
HARDIPANEL & CEMPANEL
SIDING
7 WATERPR❑OFING
PER 2121 .6.2.1
❑F F,B.C,
5/8' PLYWOOD
SHEATHING
...., s-dm Flcrrids
R� Pik
Dirbba
HI
WALL LENGTH
I II �� II II II
11 II II II II
tALL
IGHT
I II
�� II II II
II II II II II
II II II II ��
B
STUDS 16' O.C.
DETI
HARDIPLANK & CEMPLANK SIDING INSTALLATION DETAILS
The planks are applled horizontally commencing from the bottom
course of a wall With 1 1/4' wide laps of top of the plank. The
optional PVC cover molding 1 5/8' wide Is applied to the bottom
plate under the bottom plank course. The vertical joints must
be over framing members, Optional PVC butt joints inserts ore
used for on -stud jointing. The planks are to be Installed over
5/8' (5 ply) APA rated plywood supported by a minimum of 2'x4'
wood studs or 20 ga. x 3 5/8' x 1 3/8' steel studs spaced a STUDS (METAL
maximum of 16' o.c. The siding shall be fastened through over ❑R WOOD)
lapping planks with 8d x 2 1/2' longal231
anized box nails over
Wood studs or with #8 x 2 1/4' ton x 0,3 5' corros on resistance
H.D. ribbed be screws over steel studs, he fasteners sha t be
placed In theuglaver-lapping area 58' o.c, vertically and 16' o c.
horizontal( Into the studs through the 5/8' plywood sheathing.
dIA since of 3/4' from the edges shall always be observed.
5/8' PLYWOOD SHEATHING SHALL BE ATTACHED TO THE STUDS IN
ACCORDANCE TO FLORIDA BUILDING CODE, WITH ANOTHER SET OF
NAILS OR SCREWS AS UNDERLINED ABOVE.
DETAIL
DESCRIPTION
Hardiplank & Cemplank siding material is a non
asbestos fiber cement product tested
In accordance with ASTM C-1185 and
meeting the requirements of the
Florida Building Code. r, .
PLANK DIMENSIONS
Width Length Thickness
59 1/2' 12 & 14' 5/16'
DESIGN PRESSURE RATING 1
Installation Design Pressure V
Wood frame -92 PSF
Metal frame -92 PSF
NOTES
I) ALL INSTALLATION SHALL BE DONE IN CONFORMANCE
WITH THIS NOTICE OF ACCEPTANCE, THE MANUFACTURER'S
INSTALLATION RECOMMENDATIONS, AND THE APPLICABLE
SECTIONS OF THE FLORIDA BUILDING CODE,
2) STUDS OF METAL OR WOOD WHERE HARDIPLANK &
CEMPLANK WILL BE INSTALLED SHALL BE DESIGNED BY
AN ENGINEER OR ARCHITECT PER THE F.B.C. AND THE
REQUIREMENTS OF THIS N.O.A.
SECTI❑N B—B
PRODUCT RFTIEM
5/8' PLYWOOD
Er;;r.::::-,• AIL
SHEATHING
12
By
WATERPROOFING
" 'odancoahw
PER 21 L1.6.Z.1
❑ F F.B.C.
NAIL OR
SCREW
RDIPLANK
CEMPLANK
SIDING
7RO:Y,:; ; RFVYMi:'P
dm>nc iF:rnL
r«« _
M1aa1 awk Hub" Cwpv)
Chiliad
JAMES HARDIE
10901 ELM AVENUE
BUILDING PRODUCTS - USA
FUNTANA, CA 92337
RESEIkCH & 0EIIIOPIIEV CUM
909-356-6300
FAX. 909 427-0634
This drawing and the copyright therein are the
DA
��' 04/02/2004
property of the above wnpany and accordlnoty
the dra*hg oust not be copied or reproducedIDG
�: HPLK-4X8
In any material Form
IM7 NO.: 2/3
'HARDIPLANK® & CEMPLANK® sr NTS
SOFFIT
WIDTH
SOFFIT LENTGH
DETAIL A
SECTION B—B
DESCRIPTION
Hardisoffit & Cemsoffit panels material Is a non
asbestos fiber cement product tested
In accordance with ASTM C-1185 and '
meeting the requirements of the
Florida Building Code. `
SOFFIT DIMENSIONS \
Width Length Thickness , X`
<48' 8,9,10' 1/4' & 5/16'
DESIGN PRESSURE RATING
Installation Design Pressure
Wood frame t53 PSF
Metal frame t 53 PSF
NOTES
1) ALL INSTALLATION SHALL BE DONE IN CONFORMANCE
WITH THIS NOTICE OF ACCEPTANCE, THE MANUFACTURER'S
INSTALLATION RECOMMENDATIONS, AND THE APPLICABLE
SECTIONS OF THE FLORIDA BUILDING CODE.
2) TRUSS OF METAL OR WOOD WHERE
B
TRUSSES 16' O.C.
HARDISOFFIT & CEMSOFFIT WILL BE
INSTALLED SHALL BE DESIGNED BY AN
ENGINEER OR ARCHITECT PER THE
DETAIL A
F.B.C. AND THE REQUIREMENTS OF THIS
eoc,=.`evcssa
N.O.A.
PRODUCT RF.YEWED
alda the FlwW
. :.02-0 190
"•:
TRUSSES (METAL<:•..•-•..r.--o
�tt'.:+,v:: (•per.
— �4
i',:y:":iS, O
HARDISOFFIT & CEMSOFFIT PANEL INSTALLATION DETAILS
OR WOOD)
Es -�� 2
Miami
C�
The soffit panels are to be Installed over minimum 2'x4' wood
Dy
myk"0O
Joists or 20 ga. x 3 5/8' x 1 3/8' steel ,Joists spaced a maximum
Mla de Pmdoetciau%a
of 16' o,c. When Installed on wood ,Joists Hardisoffit shall be
°
fastened with Gd x 2' long galvanized box nallsl on steel
studs it shall be fastened with #8 x 1 1/4' x 0,315' corrosion
JAMES HARDIE
ELM
H AVE
1D9D1 10901FONTCA 9
resistance H.D. ribbed bugle screws. The fasteners shall be
BUILDING PRODUCTS - USA
9D9-356-6300
placed 4' o.c. around the perimeter of the panel and
RBEVICN & DEVE WlI Nf COM
FAX- 909-427-1
Intermediate studs, Nails and screws shall have a minimum edge
HARDIS❑FFIT
This drawing and the copyright therein are the
DALE: 04/02,
distance of 3/8' and a minimum clearance of 2' from corners.
& CEMS❑FFIT
property of the above company and accordigly
aRc ND.:
PANEL
the dr.*Ing oust not be copied or reproduced
HSOFF
In any material form Whatsoever.
XLT .: 3/3
FASTENER
mte UADnTGr1CCTTdb o rc-mcn[-CTTdb
sAu: AITT