HomeMy WebLinkAboutProduct Approval; Roofing UnderlaymentsFlorida Building CodehMpbr>ffloridabuilding,org/pr/pr_app_dtl.8Spx?param=wGEVXQwtDgtgkcMGblcW71%2fZr7gdugvK%2byVUTv85luE%3d
4,06"!
nGtS 1,/01110 Log In user Registratlol+ rlol Topics
Bushessi,. .
SuDalir 901(1)arge Sta is B Facts Pu bbea4nns
FDC Starr )'aCIS Site Mao Links Search
Professional ifl USER ublli
User
nil a.,.,,.:J:p4-)gar 1•:.. r1> : er,u:u.��.. l.nµ6rni,an�•.:).lr > W)nW.11.11:l.lNl > Application Dotail
• FL N
FL9777-R3
Application Type
Revision
Code Version
2010
Application Status
Approved
Corrrelents
Archived
Product Manufacturer
Owens Corning
Address/Phone/Email
One Owens Corning Parkway
Toledo, OH 43659
(740) 404.7029
greg.keeler rr owenscorning.corn
Authorized Signature
Greg Keeler
g reg. keeler9owensc orning. c o m
Technical Representative
Add ress/Phone/Errs i l
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
I
Underlayme nts
Compliance Method
Evaluation Report from.a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Nacre who developed the
Zachary R. Priest
Evaluation Report
Florkla License
PE-74021
Quality Assurance Entity
1.11.. I.LC
Quality Assurance Contract Expiration Date
03/0812015
Validated By
Locke Bowden
Certificate or Independence
Refurenced Standard and Year (Of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Validation Checklist - Hardcopy Received
F0777-10. C011JCR14002.Lvaluatioa-RapmL-2010 FW-W- tImLock
050714.pdf .
"AmIlaird
ASTM D 1970
Method 1 Option D
05/06/2014
05/08/2014
05/08/2014
06/23/2014
Page 1 cf 2
Year
2001
Florida Building Codet> kooridebuilding.org/pr/pr_app_dtl.aspx?param=wGEVXgwtDgtgkcMGbIcW71b/e2(Zr7gdugvKb/o2byVUTv85luE%3d
Summary of Products
FL # Model, Number or Name
9777.1 Weatherfock C,
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ; Yes
Impact Resistant: N/A
Design Pressure: N/A
Other; See evaluation report for limits of use.
9/7/.2 Weatherlock MAT
Limits of Use
Approved for use In HVHZ; No
Approved for use Outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
9777.3 WeatherLock Specialty Tile & Metal
Limits of Use
Approved for use in HVHZ: No
Approved for use Outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Description
Weatherproofing Underlayment
Installation Instructions
GL977.7 as it nro ,10 2 LtialuaLian.Rupoct ?1)I0 FUC
WeatherLock.OSU2JA.pdf
Verified 13y: Zachary R, Priest 74021
i Created by Independent Third Party: Yes
Evaluation Reports
FL9177 R3 AEOCIi14001-EvaluaLioa.ROpolt-2UIO.FaC
W"Oth" 1-04-k:050714+df
Created by Independent Third Party: Yes
Waterproofing Unde0ayment
Installation Instructions
F.L9/'r� un 11,OCtLLrl002ktwlaatksn Repwl 201D err
Wc:at..hctLock 05"-pdf.
Verified By: Zachary R. Pflest 74021
Created by Independent Third Party: Yes
Evaluation Reports
F.L9777-R3-.AL'.;(JCRi,1002 Evaluati=-RepoiL.2010.EL(-
WCBW mLQl; U50714.pdt
Created by Independent Third Party: Yes
Weatherproofing Underlayrmnt
Installation instructions
F:L9777—R3 Il_0Cf114002 Evaludtiort.Iteport.2010.F.BC
jlveathcrLock_G50714-pdf
Verified Sy: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
p[n77.7 Ji3 ec nr'atsn^2 Lvalua tiUn..rrep0[C2010..EBC
�lvcathed.ocl�OSpLlq.pdf
Created by Independent Third Party: Yes
rnnr.,a uc :: Joao u-,en af.. a,,,.. awo..r rallanue^^ n »l Chon^• ASO All 2. 11114
the Ste too of Flor1da is an AAy LLO umptoyeI, r^ay1ynr mnP 2111a stare ^r rin„d.. .• &itcacy sram mnm :: n..^.y6i)it cr..r^.
K ^� :: Rrfund_Vaeeaw_nt
Under florida law, email addresses arc public records. It you do not "ant your a -mall addles$ released in response In a'nubllc-woids request, no not send
e Ic'chpnlc mall to this onlity. Instead, contact the office by phone or by traditional mail. If you have any glte StiOnS. pleakC Contact e50.4b7.1305. 'Pursuant to
Section 455.27S( I ), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must Prnvide the DaParin,ent will an email address or
they have one. Tile Mails pfovided•may be used for ofricial communication with the licensee. Hnvever email addresses are public record. If you do not "ish to
supply a personal address, Please provide the Department "cth an Cmall address "filch can be made available to the public. I determine or you arc a IIce' under Chapter 455, F.S., pfea$e dirk heroo
Product Approval Accepts:
Page 2 of 2
CREEK
Certificate ofAuthorrzafrorr No. 29824
17520 Edinburgh Drive
i. Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)4803421
EVALUATION REPORT
2010 FLORIDA BUILDING CODE
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC
lssired May 7, 2014
1 Owens Corning Parkway
Toledo, OH 43657
(800)438-7465
www. gwenscoriiing.com
Manufacturing Location: Brentwood, NH
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Underiayments
Code Sections: 1507.2,4, 1507.2-9,2, 1507.3.3, 1507.5.3
Properties: Physical properties
REFERENCES
En i Reoort No.
PRI Construction Materials Technologies (TST6049) NEI.039-02-01
Standard.
ASTM D 1970
ygar
2001
PRI Construction Materials Technologies (TST6049) NEI-042-02.01REV2
ASTM D 1970
2001
PRI Construction Materials Technologies (TST5049) NEI-045-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST6049) NEI-045.02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST6049) NEI-053.02-01
TAS 103
1995
PRI Constriction Materials Technologies (TST6049) NEI.053-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST6049) NEI.093.02-02
ASTM D 1970
2001
PRI Construction Materials Technologies (TST6049) CCF-213.02-01
ASTM D 1623
2009
PRODUCT DESCRIPTION AND Limas OF USE
WeatherLock® G WealherLock® G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-fl x 66.7•ft.
WeatherLock® G is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock(D Mat WeatherLock® Mat is an ASTM D 1976 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock® Mat is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock® WealherLock® Specialty is an ASTM D 1970 self-adhesive underlayment constructed
Specialty Tile & Metal from SBS modified asphalt and surfaced with a non -woven polyester fabric. The product
is supplied in 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft and 2.14 sq. rolls with
nominal dimensions of 3-ft x 71.3-ft.
OCR14002 FL9777-R3 Page 1 of 3
This evaluation report is provided for Stale of Florida product approval under Rule 9N.3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which.this report is valid.
This evaluation report does not express not imply warranty. installation, recommended use, or other product attributes that are not
specifically addressed herein
I 1 K OWENS CORNING ROOFING AND ASPHALT LLC
G
i WeatherLock® Self -Sealing Ice & Water Barriers
TECHNICAL SERVICES,
LLC
WeatherLock®
WeatherLock@ Specialty Tile & Metal is permitted to be used with mechanically fastened
.Specialty Tile &Metal
(continued)
asphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes or
shingles, and slate roofing as prescribed in the FBC. WeatherLock® Specialty Tile &
Metal is permitted to be used with adhered clay or concrete Tile roofing using either 3MTM
2-Component Foam Roof Tile Adhesive AH-160 (3M Company) or TILE BONDTm Roof
Tile Adhesive (The Dow Chemical Company) up to a maximum design pressure of. -45
psf and in accordance with the system approval. Exposure on the roof deck shall be
limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when. used with clay or concrete the installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater than 10 tiles per stack.
PRODUCT APPLICATION
Min. Roof Slope:
2:12 or in accordance in with FBC
Application:
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and con'scted prior to underlayment
application. Prior to beginning installation, the undertayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed direct -to -plywood decking with the release backer
removed and pressed firmly into place to ensure complete contact with the deck. The
underlayment shall be installed with the roll length parallel to the eave, starting at the
eave, and with minimum 3" side laps and minimum 6" staggered end laps, End laps for
WeatherLock® Specialty Tile & Metal shall be primed with ASTM D 41 or
primer sealed
with asphalt roof cement a minimum of 3-4 inches across the Width of the lap.
It is permissible to nail the underlayment 18-inches on -center as needed (nails shall be.
installed perpendicular to deck with the nail heads flush tothe top surface of the
underlayment).. WeatherLock® Specially Tile & Metal shall be .back nailed when
installed on roof slopes greater than 3:12.
For valley• applications, the roll shall be applied centered along the valley prior to
installing the underlayment at the eave. For eave protection, the underlayment should
extend to a point 24-inches inside the exterior wall.
The underlayment shall be installed over metal drip edge at the eave, and under the drip
edge of the rake or valley pan when used as a valley liner. Alternately, it is,permissible
to install the underlayment under the drip edge in accordance Section 1507.2.9.3.
Min. Application
40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature:
application.temperature.
GENERAL LIMITATIONS
1) This_evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation,
3) Installation of the evaluated product shall comply with this report, the.FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant_ installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
6) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
OCR14001 FL9777•R3 Page 2 of 3
This evaluation report is provided for State of florlda product approval under Rule 61020.3. The manufacturer shall, notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK OWENS CORNING ROOFING AND ASPHALT LLC
Weatherl.ock® Self -Sealing Ice & Water Barriers
w TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein have demonstrated compliance with the 2010 Florida Building Code as evidenced in
the referenced documents submitted by the named manufacturer.
W'Y rF3 r►p����+
CE IV
No 74021
2014.05.07
, �'. STATE OF �� 20:18:15-04'00'
O R 1 Q••\`�� Zachary R. Priest, P.E.
++�+,S 0 NAB tE���Flo Organization No Registrationida No, 71 21
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
Products under this evaluation.
CREEK Technical Services, LLC IS not owned, operated, or controlled by any company manufacturing or distributing products under
[his evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR 14001 FL9777-R3
This evaluation report is Page 3 of 3
provided for State of Florida product approval under Rule 61G20.3. The manufaciurer shall notify CREEK
Technical Services, LLC of any product, changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
. t. rot1-i- Purtut116,,-uur k.rruine
`A
���1
r+ti. .ry. )
�k�i1•
`
�
f
j��}+ I .J^/y: ;:• .
-
BMsInes.V
8CI5 Home Log In User Registration not Topics subma Surcharge
.
,
Iona!
Professi
Pr�oduct:
Public uApproval
ser
11 a i *,.,
Page 1 01'4
f:
Stats & Facts Publications F8C Staff BCIS Site Map
Links Search
Prudut�•ADDrgval o-renu > P�o•Juct or Aup Lcabon Sr,•s rcn > A6Dl:i anon!jE > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phon a/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who
developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By .
Certificate of Independence
FL11698-RI
Revision
2010
Approved
a
Englert 'Inc.
1200 Amboy Ave.
Perth Amboy, NJ 08861
(732) 826.8614 Ext 3909
i-triPod@englertinc.com
James L. Buckner P.E.@CBUCK Engineering
jimmy@cbuckinc.net
Joseph F, Tripod
1200 Amboy Avenue
Perth Amboy, NJ 08862
(732)826.8614
jftripod@aol.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
James L. Buckner, P•E @ C-Buck, Inc.
PE-31242
Keystone Certifications, Inc.
12/31/2015
Steven M. Urich, PE
Validation Checklist • Hardcopy Received
FL11698 R1 COY CertOF1ndeo.odf
Referenced Standard and Year (of Standard) Standard
TAS 125
UL 1897
Year
2003
2004
h1Lp: ,'A.oridabuilding.org,Jpr/pr_app_dtl:aspx?param=u,GCVXQ«,tDysQFcSK%2f l'iZeD%2bAMp9rG 3Li...
"••..•• uu,nauiL{ �,vue V111111C
Page 2 of 4
UL 580 2006
Equivalence of Product Standards
Certified By
Florida Licensed Professional Engineer or Architect
FL11698 R1 Eauiv Test Standard Eouiv odf
Sections from the Code
Product Approval Method
Method' 1 Option D
Date Submitted
12/13/2011
Date Validated
12/16/2011
Date Pending FBC Approval
12/22/2011
Date Approved
01/31/2012
Summary of Products
FL # Model, Number or !Name
Description
11698,1 1 Englert "Series 500"
Roof Panel- 26 Gauge Steel, 21" Width, Attached to Plywood De
Limits of. Use
Installation Instructions
FL11698 Rl 11 1 S500 26aa WoodDeck EVALREPORT.
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: James L. Buckner, RE P.E. #31242
Design Pressure: +N/A/-79
Created by Independent Third Party: Yes
Evaluation Reports
Other: Refer to Evaluation Report for
Limitations and Conditions of Use. Refer to
FL11698 R1 AE 1 5500 26aa WoodDeck EVA'LREPORT.odf
Created by Independent Third Party: Yes
manufacturer's installation instructions as a
supplementalguide for attachment.
11698.2 2 Englert 'Series 500"
Roof Panel - 0.032" Aluminum, 211,Width, Attached to Plywood
Deck
Limits of Use
Approved for. use In HVHZ: No
Approved for use outside HVHZ: Yes
Installation Instructions .
FL11698 R1 II 2 5500 0 :2 rum WoodDeck EVALREPORT.�df
Verified By: James L.
Impact Resistant: No
Design Pressure: +N/A/-84
ckner,' P.E P.E. #31242
Created by Indepenpnt Third Part Yes
y'
Other: Refer to Evaluation Report for
Limitations and Conditions of Use. Refer
Evaluation Reports
FL11698 R1 AQ, 2 SSOD_ 032A1um WoodDeck EVALRE.PORT•odf
to
manufacturer's installatl6)1 instructions as a
Created by Vdependent Third Party: Yes
supplemental guide for atte hment.
11698.3 3 Englerti eries 1000."
Roof panel - 24 Gau a Steel, 20" Width, Attached to A wood Deck
Limits of Use
I+istailation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ:'-yes
FL11696 R1 11 3 5100eck E
0 24oa WoodDVALREPOORT.Ddf
Verified By: lames L. Buckner, P.E P.E. #31242
Impact Resistant: No
Design Pressure: +N/A/-52.5
Created by Independent Third Party: Yes
EvaWation Reports
Other: Refer to Evaluation Report f6r
Limitations:and Conditions of Use/Refer to "
FL11698Rl AE 3 S1000 24 a WoodDeck EVALREPORT,odf
Created by Independent Third Party:
manufacturer's installation instructions as a
Yes
supplemental guide forattarJ'ment,
11698 4 4 - En tert "Series 1100"
Roof'Ranel - 24 Gauge Steel, 16" Width, Attached to Plywood Deck
Limits of Use
Approved for use -fin HVHZ: No
Approved
Install tt\on Instructions
FL11698 81 I1 4 SHOO 24U WoodDeck EVALREPORT.pd(
for yse outside HVHZ: Yes
Impact Resistant: No
Verified By:`James L. Buckner, P.E P.E. #31242
Design Pressure: +N/A/-60
Created by In Third Party: Yes
Evaluation Reports
Other: Refer to Evaluation Report for
Limitations and Conditions of Use. Refer to
FL11698. R1 AE 41. 1100 24oa WoodDeck EVALREPQRT.pdf
Created by independent Third Party: Yes
manufacturer's installation instructions as a
supplemental guide for attachment.
11698.S
5 - Englert "Series 1100"
Roof Panel - 0.032" Aluminum, 16" Width, Attached to Plywood
u
http:/%floridabuilding.orgipr/pt_app_dtl.aspx?param=wG1 VXQH-tDgsQFc5K%2f 1'rZcD%2bAMp9rG3L1... 3/20,22012
Limits Of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-37.5
Other: Refer to Evaluation Report for
.imitations and Conditions of Use. Refer to
nanufacturer's installation instructions as a
upppemental guide for attachment.
Limits of.Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-165 max.
Other; Refer to Evaluation Report for
Limitations and Conditions of Use. Refer to
manufacturer's installation instructions as a
supplemental guide for attachment.
11698.7 7 -Englert "Serip
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant No
Design Pressure: +N/A/-37.5
Other:.Refer to Evaluation Report for
Limitations and Conditions of. Use. Refer to
manufacturer's installation instructions as a
supplemental guide for attachment.
11698.8 8 - Englert"C Panel"
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-62
Other: Refer to Evaluation Report for
Limitations and Conditions of Use. Refer to
manufacturer's installation instructions as a
supplemental guide for attachment.
11698.9 119 - Englert "C Panel"
Llmlts of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-99
Other: Refer to Evaluation Report for
.imitations and Conditions of Use. Refer to
nanufacturer's installation instructions as a
supplemental guide for attachment
Nige i ot' 4
Installation Instructlons
FL11698 R1 11 5 51100 032A1um WoodDeck EVALREPORT,pdf
Verified By: James L. Buckner, RE P.E, tt3Z2gZ
Created by Independent Third Party: Yes
Evaluation Reports
FL11698 R1 AE 5 ,S1j40 032A1um Wootl�eck EVALR PORT.pdf
Created by Independent Third Party: Yes
Installation Instructlons -
FL11698 R1 II 6 $1101 24Qa WoodDeck EVAIREPORTI-20f verified By; James L. Buckner, P.E P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL11698 R1 AE 6 S1101 24ga WoodDeck EVAIREPORT.pdf
Created by Independent Third Party: Yes
Roof Panel - 0.032" Aluminum, 16" Width, Attached to Plywood
Deck
Enstallation Instructions
FL11698 R1 it 7 51101 032A1um WoodDeck EVALREPORT.uclf
Verified By: James L. Buckner, P.E P.E. #31242
Created by Independent Third Party: Yes
Evaluation Reports
FL11698 R1 AE 7 S1101 032A1um WoodDeck EVALREPORI�- l
Created by Independent Third Party: Yes
Panel - 26 Gauge Steel, 24" Width, Attached to
Deck
installation Instructions
FL11698 R1 II 8 CPan 126oa WoodDeck EVALREPORTodf
Verified By: James L. Buckner, P.E P.E. #31242 .
Created,by Independent Third Party: Yes
Evaluation Reports
FL11628 R1 AE 8 CPanel 26ga WoodDeck_EVALREPORT 0 f
Created by Independent Third Party: Yes
Roof Panel , 0.032" Aluminum, 24" Width, Attached to Plywood
Deck
Installation Instructlons
FLL1698 Ri 11 9 CPanel 032A1um WoodDeck EV L EPORT. pdf
Verified By: James L. Buckner, RE P.E. #31242
Created by Independent Third Party: Yes
:valuation Reports
Created by Independent Third Party: Yes
6ac= Next
Contact ;: 1940 Nortn Monroe Street r0114-- phone: 85Q 487.1824
The State of Flonda IS an AA/EEO employer. Copyright 2007-2010 State of rtor'da :: Privacy Statement .: AicesstbiFity Statement :: R f n
�u d Statement
Under rlonda taw, e-mail addresses are public records. If you do not want your a -mail address released In response to a public -records request. do not
send electronic mad to this entity. Instead. contact the office by phone or by traddionat mad. 1f ybou have an
accessibility. please contact our Web Master at h se i Questions regardmq DBPR's ADn weD
we master.cldor cat Liu.
.
Product Ar ppjoval Accepts:
�
Iittp:'/floridahuilciing.org/pr/pr_app_dtl.aspx?para111=%v XQ�� tDgsQFcSK%3f'[ rleD%2bA%,1p9rG )... 3'30,2()1
1
. a
5ppclalty Structural EnglnpE*rinq CeUCx, Inc. Certificate of Authorization J18064
Evaluation Report
"Englert° Series 110111
Metal Raof Assembly
Manufacturer:.
Englert, Inc:
1200 Amboy Avenue
Perth Amboy, NJ 08862
I732)826:8614..
for
Florida Product Approval
# FL 11698.6-Ri
..Florida. Building Code 2010
Per Rule 9N-3
Method: 1= D
Category: Roofing
Sub - Category: Metal Roofing .
Product: "Series 1101" Roof Panel
Materiai: Steel
Panel Thickness: 24 gauge
Panel Width: 16"
Panel'Seam: Snap -Lock .
Support: Wood Deck
Prepared by:
James L. Buckner, P.E:, SECB
Florida Professional Engineer #. 31242 .
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report. No. 11-188-51101-S4W-ER
Date: 11/24/11
Contents: -
Evaluation Report Pages 1-7 ames L. Buck ier, P.E., SECB
Florida RE. N 311242
CHUCK, Inc.
1399 N. Killian Drive, Suite 4; West Palm Beach, Florida 33403 1
Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuckinc.net
FL N: F1 11698.6-Ri
Date: 11 / 24 / 11
�P ,, leering��Report No.: 11-188-S1101-S4W-ER
Page 2 of 7
Spt=Clalf y
Structural Englnapring CBUCK, lnc. Certificate of -Authorization #8064
Manufacturer:
Englert, Inc.
'Product Name:
"Series.11011,
Product Category:
Roofing
.-Product, Sub -Category
Metal Roofing
Compliance Method:
State Product Approval Rule 9N-3.005 (1) (d)
Product/System
"Series 1101" Roof Panel
Description:
24 gauge steel Nailstrip roof panel mechanically attached to Wood Deck with
screws.
Product Assemblyas
Refer to Page 4 of this report for product assembly components/materials &
Evaluated:
standards:
1. Roof Panel
2. Fasteners.
3. Adhesive (select systems)
4. Underlayment
5. Insulation (Optional)
Support:
Type:
Wood Deck
(Design of support system is outside the scope of this evaluation.)
Description:
• 15/32" or greater plywood,
• or Wood plank (min. specific gravity of 0.42)
Slopes
Minimum slope shall be:.3 : 12 or greater
In accordance with manufacturer's recommendations, FBC Section 1507.4.2 and
applicable code sections.
Performance:
Wind Uplift. Resistance:
• Design Uplift Pressure:. METHOD 1: -150 PSF
(Refer to "Table A" attachment details herein) METHOD 2: • 165 PSF
e
FL fi: FL 11698.6-R1
Date: 11 / 24 / 11
Report No.:88 52101-54W ERCE UCH 3of
Sppelalty Structural Englneprinq CBUCK, Inc. Cerrificote of Authorization a806A
Performance The product described herein has demonstrated compliance with:
Standards: • ULS80-06 — Test for Uplift Resistance of Roof Assemblies
• UL 1897-04 — Uplift test for roof covering systems
• TAS 125-03 —Standard Requirements for Metal Roofing Systems
Standards Equivalency: The UL 580-94.& UL 1897-98 standard version .used to test the evaluated product
assembly is equivalent with the prescribed standards in UL 580-06 & UL 1897-04
adopted by the Florida Building Code 2010.
Code Compliance: The product described herein has demonstrated compliance with Florida
Building Code 2010, Section 1504.3.2.
Evaluation Report This product evaluation is limited to compliance with the structural
Scope: requirements of the Florida Building Code, as related to the scope section to
Florida Product Approval Rule 9N-3.001.
Limitations and Scope of "Limitations and Conditions of Use" for this evaluation:
.Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance
with Rule 9N-3.005. Per Rule 9N-3.004, the Florida Building Commission is
the authority to approve products under "Optional Statewide Approval
• Option for application outside "Limitations and Conditions of Use"
Rule 9N-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods. and materials authorized in the Code". Any modification
of the product as evaluated in this report and approved by the Florida
Building Commission is outside the scope of this evaluation and will be the
responsibility of others.
• Design of support system is outside the scope of this report,
• Fire Classification is outside the scope of Rule 9N-3, and is therefore not
included in this evaluation.
This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity through Keystone Certifications, Inc, (FBC. Organization
ID# QUA 1824).
FL M FL 11698.6-111
Date: 11 / 24 / 11
��^^�» gg gga�d
�.�„ 4�.�CY'�e. n. rn crarin Report No.: a - 88-S110,1-S4W-ER
Sppctdlty Structural Englnserinq
Components/Materials Roof Panel:
(by Manufacturer): Material:
Thickness:
Panel Widths:
Rib Height:,
Yield Strength:
Corrosion Resistance:
Fastener:
Type;
Size
Corrosion Resistance:
Standard:
Seam Adhesive/Sealant:.
Product Name:
Type: .
Application Size:
Application Location:
Components&
Materials, -
(by Others)
CBUCK, Inc. CertiJ;coreOlAuthorizotion#8064
Englert Series 1101
-Steel
24 gauge (min.)
16" (max.) Coverage
1„
40 ksi_min.
Per FBC Section 1507.4.3
Pancake -Head Wood Screw
##10 x 1"
Per FBC Section 1506.6 and 1507.4.4
Per ANSI/ASME 818.6.1
Bostik Chem-Chaulk 915
One component, polyurethane adhesive
.3/8" bead
along male flange the full length.of panel
(Refer to Table "A" and drawing Pg 6-7)
Underlayment:
Per roofing manufacturer's guidelines in compliance with FBC Section 1507.4.5
Insulation (Optional):
Type: Rigid Insulation Board
Thickness: 3" (max.)
Properties:
Density: 2.25 pcf (lbs/ft3) mina
Or Compressive Strength: 20 psi min.
Insulation Notes:
• Insulation shall comply with FBC Section 1508. When insulation is
incorporated, fastener length shall conform. to penetrate thru bottom of
support a minimum of 3/16
8"UCK Engineering
FL #: FL 11698.6-111
Date: 11 / 24 / 11
Report No,: 11-188-S1101-54W-ER
Page 5 of 7
ISpeelalty Structural En9im—erinq CBUCK, Inc. Certificate oJAuthorizotioa #8064
Installation: Installation Method:
{Refer to "TABLE A" below and drawings on Pages 6-7 of this evaluation report.)
• Fastener Spacing: Refer to "TABLE A" Below
(along the length of the panel)
■ Rib Interlock: Snap -Lock
(Panel ribs shall be fully engaged to form an integral snap -lock.)
■ Seam Adhesive: Refer to Table "A" & Drawing Page6.
(Apply along male flange the full length of the panel.)
■ Minimum fastener penetration thru bottom of support, 3/16".
■ For panel construction at the end of panels, refer to manufacturer's
instructions and any site specific design.
TABLE "A" --
4 NIETHOD�IA a
s�r
METHOD 2
Design Pressure:
�, �150 PSF � `t}
- 26S PSF
Fastener Spacing:
6" o.c.
3" o.c.
Seam Adhesive:
Not required
.3/8" bead
(Refer to pg . 6.7)
Install the "Series 1101" roof panel assembly in compliance with the installation
method listed in this report and applicable code sections of FBC 2010. The
installation method described herein is in accordance with the scope of this
evaluation report. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Referenced Data: 1. TAS 125 Uplift Test
By Architectural Testing, Inc. (FBC Organization ID# TST 1558)
Report No. 93745.01-109-18, Date: 11/16/09
Specimens #1-3
2. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID# QUA 1824)
Englert, Inc. Licensee #420
3. Equivalency of Test Standard Certification
By James L. Buckner, P.E. @.CBUCK Engineering
(FBC Organization # ANE 1916)
4. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
M
FL 4: FL 11698.E-111
U Date: 11 / 24 / 11
t.,n.• � ". ,"` � tl � �� �,a�� RRepeort No.: 11- 88-S1101-S4W-ER
B
Spp=1C51tLj Structural EnglnPPrinq CBUCX, Inc. Ceftificate of Authorization #8064
Installation Method
Englert, Inc.
"Series 1101" (24 gauge Steely Roof Panel attached to Wood Deck
Drawings
16"
1
3/4"
1
Panel Profile
I
16" O.C. -- ---�j .
Integral Snap Lock
For METHOD 2:
APPIy 3/8" bead Bostik Sealant
entire length of panel
_#10x1"
Pancake -Head Screw
Typical Assembly Profile View
(Typical Fastening Pattern Across Width)
FL ff: FL 11698.E-R1
u g Date:. 11 / 24 / 11
.�JCK 1ner'1 s Page Re,ort No.: 11-187 of 7g-51101 54W ER
Sppelelfiy Structural Engle=PrinQ c8ucK, Inc. Certificate of Authorization #8064
Installation Method
-En' lert; Inc.
"Series 1101" (24 gauge Steel) Roof Panel attached to Wood Deck
Fastener:
#10 Pancake=Head Scr
"Series 1101`' Roof Panel --- _ —_--
y
318" Bead Seam Adhesive
16/32" Wood Deck continuous along male nb
(Refer to Table "A")
Typical Roof Assembly
Isometric Vlemi
(Optional) Rigid Insulation Board per Page 4 of this report
TABLE "A"
j
METHOD 1
METHOD 2
i Design Pressure:
-150 PSF
-165 PSF
j Fastener Spacing:
6" o.c.
.3" ox.
Seam Adhesive:
Not required
3�g, bead
(Refer to pg :6.7)
ENGLERT METALMAN HT
ENGLERT METALMAN HT High Temperature underlayment is a 40 mil self-adhesive waterproofing membrane
composed of SBS modified bitumen and a tough UV anti -slip polyethylene woven top facer. The release film backing is
also UV resistant and protects the product from degradation when stored outside for less than 90 days without the need
for a cardboard box.
ENGLERT METALMAN HT is designed for use in high temperature environments where the in-service temperature
can reach temperatures as high as 240°F. This self sealing, high tensile strength underlayment' will provide maximum
waterproof protection before, during and after the installation of a metal roof system.
• Self -adhered High Temperature
underlayment
• Material composed of special
elastomeric modified bitumen
blends of SBS and other polymers
• Features tough ant -slip polyethylene
woven top facer (100% UV resistant)
• Designed for use rn extremely hot
climates where surface temperatures
are as high as 240'F
• Self-sealing composition provides
water proof protection (ASTM D 1970)
• Excellent.heat reflectivity and high
tensile strength ensure maximum
performance when installed under a
metal roof
• Underlayment can be exposed to the
elements for periods of up to go days
prior to roof being installed
• Product is easy to install
• Miami -Dade Compliant
NDA a08-0225,10
• Florida Building Code Complaint
FL'-i351.1
MATERIAL COMPOSITION
Elastomeric Bitumen
Core Material
Topside Composition
Underside Composition
Approx. Nominal Thickness
Approx. Gross Roll Coverage
Side Lap (if applicable)
End Lap (if applicable)
Roll Length
Roll Width
Approx. Roll Weight
Rolls per Pallet
High Temperature Rating
Part No.
Low Temperature Flexibility ASTM D 1970
Peel Resistance on Plywood ASTM D 903
Florida Building Code
Miami -Dade Product Control Approved
Load Strain Properties @ 777
Maximum Load (LBS/IN)
Elongation @ Maximum Load
Blend of bitumen & SBS polymers
Elastomeric bitumen (blend of bitumen & SBS polymers)
Tri-laminate polyethylene
Self adhered with release material
40 MIL
200 FT'
3 IN
6 IN
67 FT
36 IN
40 LBS
25
240'F
07050I
-22'F
11.4 LBS/FT
FL 11351.1
NOA #08-0225.10
Machine Direction
64
52
Cross Machine Direction
88 _.
24
.ate'..