HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE-SCOPE OF WORKPAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 SCOPE OF WORK 1. EXISTING STAIRS REPAIRED PER REPORT BELOW: 1. TREADS - SEVERAL TREADS WERE REPLACED W/ (2) 2X6 MAINTAINING 10.5" TREAD W/ I" NOSING TO MATCH EXISTING AND (2) #10 DECK SCREWS PER BOARD TO STRINGERS 2. RISERS - SEVERAL RISERS WERE, REPLACED WITH 1X SCREWED TO STRINGERS W/ #10 SCREWS, 6" RISERS WERE MAINTAINED BY BUILDER TO MATCH EXISTING 3. STRINGERS - STRINGERS WERE REPLACED USING PT 2X12 STRINGERS - THE OUTSIDE STRINGERS WERE ATTACHED USING (2)'/i' THRU BOLTS TO POST AND THE MIDDLE STRINGER WAS TOE NAILED TO THE CROSS TIE 4. RAILING - SEVERAL STAIR RAILING MEMBERS WERE REPLACED WITH LIKE FOR LIKE MATERIALS - THE BUILDER MAINTAINED THE 36" HEIGHT REQUIREMENTS FOR THE STAIR RAILING W/ A GRASPABLE HANDRAIL AND ALSO MAINTAINED LESS THAN 4" BETWEEN THE BALUSTERS IN THE RAILING 5. POST - POSTS WERE REPLACED WITH PT 4X4 WOOD POSTS - POST BASE CONNECTORS WERE REPLACED USING SIMPSON ABU 44 W/ (12)-16D NAILS AND (1) 5/8" A.B. W/ 6"' MIN EMBD. 6. 2ND FLOOR LANDING - 2ND FLOOR LANDING WAS NOT REPLACED 7. INTERMEDIATE LANDING - INTERMEDIATE LANDING WAS NOT REPLACED S. IST FLOOR LANDING - THE RUN OF STAIRS BETWEEN THE INTERMEDIATE LANDING AND THE GROUND LEVEL WERE NOT REPLACED ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE FBC 2020 FOR EXISTING BUILDINGS, THE FBC 2020, AND THE FBC 2020 RESIDENTIAL THIS IS AN ALTERATION LEVEL 1 AND COMPLIES WITH THE FBC 2020 FOR EXISTING BUILDINGS CHAPTER 6 AND 7 Re: Case# 104979 Casa Caprona Stair Repair Inspection 2605 St. Lucie Blvd. Ft. Pierce, FI. Paul Welch, Inc. Paul Welch P;E. - Fla. Reg. -No. -29945 AUG 2=1=2Q21 4 L=� Planning & Development Services Department r ( - Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1577 Certification for Design Load Compliance 7th Edition Project Name: Casa Caprona Stair Repair Project Address: 2605 St Lucie Blvd Fort Pierce, FL Permit#: 2108-0846 Occupancy Type: Residential Construction Type: CB StUCCO INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format (PDF) version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 1,010 Code 7th Edition using ASCE 7-16 2. Structure Designed as (check one): Enclosed Partially Enclosed Open 3. Risk Category: I II III IV Exposure Category. X, B C D 4. Design Wind Velocity ) mph G (p ASD LRFD End Zone Width: ft S. Mean Roof Height 115 ft Roof Pitch: N 1k :12 Parapet.—WA—ft 6. Components & Cladding Design Pressures Used: Zone 4 Vp.'. Zone 5: '52.4 Garage: 0 Ik 6a. Roofs Maximum +/- pressures: + 0/14 psf - fiJIA- psf Or define individual zones on the plans 7. Design Loads: Floor: MIA PSF Roof -Dead: MLA PSF Roof -Live: Balcony+/- MIA PSF Dock:_ _ __PSF Deck: PSF Stairs: t 0� PSF Fence: —PSF Railings: 50Bela PSF 8. Were Shear Walls Considered For Structure? Yes Not Applicable Please Explain: 9. Is a Continuous Load Path Provided?_5 Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: �L PSF Soil Test Reports Submitted? tJ/ Yes No Assumed I certify at, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply th the applicable structural portions of the current Florida Building Code as adopted. Signature, ate, and5eal_ _Print Name Cert# & Co. CertofAuthorization Revised 3/25/2021 Company Name & Address€