HomeMy WebLinkAboutROOF PLAN VIEW PROJECT DESCRIPTION NORTH SYSTEM CAPACITY: 11.52 KW DC/9.28 KW AC PV PANELS:(32) LG NeON R 360N1C-N5 360W BY LG NCOMBINER: (1)IQ COMBINER BOX BY ENPHASE INVERTER: (32)IQ7+BY ENPHASE EXISTING ELECTRICAL METER RACKING SYSTEM:CROSS RAIL SYSTEM 44-X BY K2 SYSTEMS PV DISCONNECT IQ COMBINER BOX PROJECT INFORMATION 2 LOCATION MAP / WIND ZONES T PROJECT LATITUDE 27.321247 MIN AMBIENT TEMP 1 °C I PROJECT LONGITUDE -80.33912 MAX AMBIENT TEMP 35°C N.T.J. ❑ WIND EXPOSURE B AHJ ST LUCIE COUNTY MAX WIND SPEED 159 MPH DRAWINGS INDEX jab'- ilx:� C-1 COVER SHEET C-2 SAFETY PLANS E-1 ONE LINE RISER DIAGRAM E-2 SAFETY LABELS S-1 STRUCTURAL PLAN - S-2 RACKING PLAN - D-1 PV MODULES DATA SHEET D-2 SMART MONITORING DATA SHEET D-3 INVERTER DATA SHEET GENERAL NOTES 1 *a PER FL.STATUTE 377.705(REVISED 7/1/2017),1 RAFAEL A.GONZALEZ �G SOTO, P.E. 83104 AN ENGINEER LICENSED PURSUANT TO CHAPTER 1 _ t area' 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL �* •+ k' � _��. N COMPONENTS ARE DESIGNED AND APPROVED USING THE w,y h}r v 0 STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE (rI FLAT FLORIDA BUILDING CODE. 3 IRRADIANCE MAP T APPLICABLE CODES:2020 FLORIDA BUILDING CODE 7TH EDITION, ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER N.T.S. 0 STRUCTURES,FFPC 7TH EDITION,NFPA 2018,NFPA 70 AND NEC 2017. ZCONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE Y� INSTALLED AND SEALED PER 2020 FLORIDA BUILDING CODE 7TH (n EDITION OR LOCAL GOVERNING CODE. ALL WIRING METHODS AND INSTALLATION PRACTICES SHALL m CONFORM TO THE NATIONAL ELECTRICAL CODE(NEC)2017, LOCAL m STATE CODES, AND OTHER APPLICABLE LOCAL CODES. MEANS SHALL BE PROVIDED TO DISCONNECT ALL CURRENT CARRYING CONDUCTORS OF THE PHOTOVOLTAIC POWER SOURCE FROM ALL OTHER CONDUCTORS IN THE BUILDING. CONNECTORS TO BE TORQUED PER DEVICE LISTING, OR MANUFACTURERS RECOMMENDATIONS.NON-CURRENT CARRYING METAL PARTS SHALL K BE CHECKED FOR PROPER GROUNDING. ~ REQUIRED SAFETY SIGNS AND LABELS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE,OR OTHER MECHANICAL MEANS,LABELS j J SHALL COMPLY WITH ARTICLE 690 VI OF THE NEC 2017 OR OTHER APPLICABLE STATE AND LOCAL CODES.SEE LABELS AND MARKING PAGE FOR MORE INFORMATION. RACKING ROOF MOUNT SYSTEM SHALL BE INSTALLED FOLLOWING MANUFACTURERS INSTRUCTION SPEC'S,INCLUDING ALL GROUNDING WEEB CLIPS,GROUND LUGS,AND RAIL SPLICE KITS FOR ELECTRICAL CONTINUITY. 4 3D RENDERING OSED ROOF PLAN VIEW / BOS LOCATION M BUILDINGS. DESIOOLGN N WIN OPRESSUN THE ES AREND OA CALCULS FOR ATED USING BUILDINGS. DESIGN WIND PRESSURES ARE CALCULATED USING N.T.S. N.T.S. ASCE 7-16 EQUATION 30.6-1.ALL NOTES IN FIGURES ASCE 7-16 30.4-1 AND 30.4-2(A,B AND/67C) HAVE BEEN INCORPORATED. MEAN ROOF HEIGHT MUST BE LESS THAN 60 FEET. DOCUMENT CONTROL DATE CAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: ISSUED FOR PERMIT 07-25-21 AC N7 SEAN MORIARTY COVER SHEET ENGIPARTNERS LLC TITAN SOLAR POWER FL REV DESCRIPTION DATE CAD QC ,.•""""" Digitally signed PROJECTADDRESS: C.A.32661 -oPp�;":y�ENsf�Fzo;i by Rafael A 12221 N US HIGHWAY 301 * TITAN 104 NORTHEAST NARANJA AVENUE 255 GIRALDA AVE e3 104 =Gonzalez Soto CORAL GABLES,FL 33134 -* o_ THONOTASASSA,FL 33592 PORT ST.LUCIE,FL 34983 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: U nAT * Date: s 0 L A R P O W E R ENG.RAFAEL A.GONZALEZ SOTO,PE Cj-1 DESIGN ENGIPARTNERS.COM %°TE•``ORtOP''�`�o 2021.07.26 (813)982-9001 TSP87051 ' N-AL EN��,.` PARCEL NUMBER: 07:01:41-04'00' DATE: SHEETS: 3419-540-0191-000-9 o-,6-202, 1 OF 9 833-888-3644 1 #EC13008093 NORTH J07L EXISTING ELECTRICAL METER N07 PV DISCONNECT IQ COMBINER BOX T W W H N O WI Z_ U W � � o H W FLAT a O o LOCATION OF NEAREST URGENT CARE FACILITY NAME: ADDRESS: PHONE NUMBER: NOTES: 1. INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME 2. INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF NEAREST 1 SAFETY PLAN URGENT CAR FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK N.T.S. DOCUMENT CONTROL DATE CAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: SEAN MORIARTY SAFETY PLAN ISSUED FOR PERMIT 07-25-21 AC NT ENGIPARTNERS LLC ,,,, TITAN SOLAR POWER FL REV DESCRIPTION DATE CAD QC „oO`�omZa"„ Digitally signed PROJECTADDRESS: C.A.32661 ;�pE,P-ti�EsIFzs% by Rafael A 12221 N US HIGHWAY 301 T I T A N 255 GIRALDA AVE � �`Gonzalez Soto 104 NORTHEAST NARANJA AVENUE 83109 CORAL GABLES,FL 33134 '*f�/T� `,*`- THONOTASASSA,FL 33592 PORT ST.LUCIE,FL 34983 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: /'� a o=Date: S 0 L A R P 0 W E R ENG.RAFAEL A.GONZALEZ SOTO,PE C-2 DESIGN@ENGIPARTNERS.COM �'',oFF`<oa;oe\��`�,c`2021.07.26 (813)982-9001 TSP87051 PARCEL NUMBER: DATE: SHEETS: 833-888-3644 07:01:49-04'00' #EC13008093 3419-540-0191-000-9 07-16-2021 2 OF 9 WIRE SIZES,QUANTITY&TYPE RACEWAY SIZE,TYPE,LOCATION&INFO. WIRE AMPACITY CALCULATIONS ADDITIONAL INFORMATION WIRE TAG CONDUCTOR NEUTRAL GROUND RACEWAY RACEWAY RACEWAY HEIGHT OUTPUT 125%OF OUTPUT MIN WIRE DE-RATED CALCULATION DIST. VOLTAGE VOLTAGE CONDUIT QTY.SIZE&TYPE QTY.SIZE&TYPE QTY.SIZE&TYPE SIZE&TYPE LOCATION ABOVE ROOF CURRENT OCPD WIRE AMBIENT *OF FINAL DROP% FILL% CURRRENT RATING TEMP COND. AMPACITY AC.1 BEFORE JB 3 IQ CABLE BY ENPHASE N/A 1 #8 AWG BARE COPPER NOT APPLICABLE UNDER ARRAY 1/2"TO 3-1/2" 13A 16.25A 20A 30A X 0.76 X 1 -22.8 A 350 0,11% ° AC.2(FROM JB TO COMBINER BOX) (6)#10 AWG THWN-2 N/A (1)#8 AWG THWN-2 3/4"EMT CONDUIT ABOVE ROOF 1/2"TO 3-1/2" 13A 16.25A 20A 40A X 0.76 X 0.8=24.3 A 20 FT. 350V 0.21% 8.1% 3/4"EMT CONDUIT EXTERIOR WALL "N/A" 38.72A 48.4A 50A 75A X 0.76 X 1 =57A 5 FT. 240V 0.1% 7.7% SERVICE) BRANCH#1 PV RAILS TO BE BONDED WITH#8 BARE WIRE 1❑ A1.1 A1.2 A1.3 A1.4 A1.5 A1.6 A1.7 A1.8 A1.9 A1.10 A1.11 tl+ + + + + + + + + + BRANCH#2 2❑ A2.1 A2.2 A2.3 B2.4 B2.5 B2.6 B2.7 B2.8 B2.9 B2.10 C2.11 + + + 3 11 EXISTING OVERHEAD SERVICE 5 © P P 240V/120V 200A BUS BAR® BRANCH#3 [-2] ��2P-20A 3#2/0 THWN-2 I�j 2P-20A 7 9 200A l� INVERTER TOTAL OUTPUT: 38.72A C3.1 C3.2 C3.3 C3.4 D3.5 D3.6 D3.7 D3.8 D3.9 D3.10 " `� l\2P-20A 50A 70 � METER SAFETY RATING (125%): 48AA NEMA3R ENVOY FUSED ® 0 TOTAL PV SYSTEM OCPD: 50A + + + + + + + + + + MAIN BREAKER RATING: 200A BUS BAR RATING: 200A 2❑ 120% BACKFEED RATING: 40A I #G THWN-2 GROUND � ONE LINE RISER DIAGRAM N.T.S. LEGEND: (32) LG NeON R 360N1C-N5 360W BY LG IQ7+MICROINVERTER BY ENPHASE 3 IQ CABLE BY ENPHASE REFER TO D-1 SHEET 2 REFER TO D-3 SHEET 3 1 #8 BARED WIRE GROUND 3/4"EMT CONDUIT 6#10 THWN-2 4 NEMA 3R JUNCTION BOX 151 1 #8 THWN-2 GROUND IQ COMBINER BOX BY ENPHASE 3/4"EMT CONDUIT 6 REFER TO D-2 SHEET 2#6 L1,L2 THWN-2 1 #8 THWN-2 GROUND 2#6 L1, L2 THWN-2 7 1 #6 THWN-2 NEUTRAL 3/4"EMT CONDUIT F PV SYSTEM DISCONNECT RATED 60A L9 1 #6 THWN-2 NEUTRAL 3/4"EMT CONDUIT Q PV INTERCONNECTION POINT/LINE SIDE TAP UTILITY ELECTRICAL SERVICE 12 NOT USED DOCUMENT CONTROL DATE CAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: SEAN MORIARTY ONE LINE RISER DIAGRAM ISSUED FOR PERMIT oT-zs-z, AC Nr ENGIPARTNERS LLC Digitally TITAN SOLAR POWER FL REV DESCRIPTION DATE CAD QC ."""G°N SI ned b PROJECT ADDRESS: C.A.32661 ;,`Pp�,.". �ExsF.,so; g y 12221 N US HIGHWAY 301 T I T A N 255 GIRALDA AVE -Rafael A 104 NORTHEAST NARANJA AVENUE - 83109 CORAL GABLES,FL 33134 ?* R ��,Gonzalez Soto THONOTASASSA,FL 33592 PORT ST.LUCIE,FL 34983 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: .I �pTE'" `e=Date: S O L A R P 0 W E R ENG.RAFAEL A.GONZALEZ SOTO,PE E-1 DESIGN ENGIPARTNERS.COM '=90'"<oRt°S''� 813 982-9001 �''.,,F,Fss�°NAL ENv„a 2021.07.26 PARCEL NUMBER: TSP87051 DATE: SHEETS: """ 07:01:58-04'0 ' 3419-540-0191-000-9 07-,6-202, 3 OF 9 833-888-3644 #EC13008093 LABEL LOCATION: INVERTER#1 LABEL LOCATION: WARNING AC DISCONNECT, LABEL LOCATION: zLWARNING DUAL POWER SOURCE POINT OF ELECTRICAL SHOCK HAZARD POINT OF INTERCONNECTION NOMINAL OPERATING AC VOLTAGE240 V INVERTER SECOND SOURCE IS PHOTOVOLTAIC SYSTEM INTERCONNECTION PER CODE: NEC 690.13(B) NOMINALOPERATING AC F- • 60 HZ PER CODE: NEC 690.52 PER CODE: NEC 705.12 (B)(3) TERMINALS ON BOTH LINE AND MAXIMUM AC POWER 9.28 KW LOAD SIDES MAY BE ENERGIZED MAXIMUM AC CURRENT38.72 A IN THE OPEN POSITION MAX OVERCURRIENT DEVICE RATING WARNING LABEL LOCATION: •- ' • PROTECTION 20A POINT OF POWER SOURCE OUTPUT CONNECTION. DO NOT INTERCONNECTION LABEL WARNING AC DIS ONNEICOT,.MAIN PANEL RELOCATE THIS OVERCURRENT DEVICE PER CODE: NEC PER CODE: NEC 110.27 (C) 705.12(B)(2)(3)(b)LABEL LOCATION: TURN OFF PHOTOVOLTAIC OSHA 1910.145(f)(7) • 60 VDC INVERTER AC DISCONNECT PRIOR TO PER CODE: NEC 690.53 LABEL LOCATION: WORKING INSIDE PANEL MAXIMUM CIRCUIT CURRENT 15.73A OCAUTION MAIN SERVICE PANEL MAX RATED OUTPUT CURRENT OF PHOTOVOLTAIC SYSTEM CIRCUIT IS SUPPLY SIDE PER CODE: NEC 690.45(B)(5) • -• - •• • • • N/A LABEL LOCATION: • • • AC DISCONNECT, MAIN PANEL PER CODE: NEC 690.56(C)(3) TURN RAPID SHUTDOWN Sochi LABEL LOCATION: LABEL LOCATION: PHOTOVOLTAIC 1 SWITCH TO THE"OFF" DISCONNECT DO NOT DISCONNECT POINT OF POSITION TOzL, AC DISCONNECT SHUT DOWN PV AND UCESYSTEM -' • 38.72 A PER CODE: NEC 690.54UNDER LOAD INTERCONNECTION HAZARD IN THE ARRAY. 240V PER CODE: • •■ - • NEC 690.33(E)(2) & NEC 690.15(C) LABEL LOCATION: qw LABEL LOCATION: PHOTOVOLTAIC AC DISCONNECT AC MAIN PHOTOVOLTAI PER CODENNECT NEC 690.13(B) CAUTION: SOLAR ELECTRIC POINT OF INTERCONNECTION SYSTEM EQUIPPE PER CODE: NEC 690.56(C) SYSTEM CONNECTED WITH RAPID SYSTEM SYSTEM DISCONNEA LABEL LOCATION: POINT OF INTERCONNECTION SHUTDOWNPER CODE: NEC 690.15, NEC 690.13(B) WARNING : PHOTOVOLTAIC ' SOURCE- LABEL LOCATION: MAIN SERVICES DISCONNECT, DC CONDUIT PER CODE: NEC 690.31 (G) (3) ,� PV SAFETY LABELS DATA N.T.S. DOCUMENT CONTROL DATE CAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: ISSUED FOR PERMIT 07.25.21 AC NT SEAN MORIARTY ENGIPARTNERS LLC Digitallysigned TITAN SOLAR POWER FL SAFETY LABELS REV DESCRIPTION DATE CAD QC " GON1 " PROJECTADDRESS: % TITAN C.A.32661 °r`�;•"yens' s' b Rafael A 12221 N US HIGHWAY 301 Q 3 F'.,�'L- �' 255 GIRALDA AVE s3iaa _Gonzalez Soto 104 NORTHEAST NARANJA AVENUE CORAL GABLES,FL 33134 '*, srnr * Date: THONOTASASSA,FL 33592 PORT ST.LUCIE,FL 34983 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: ��ORtOP'�'¢��'2021.07.26 S 0 L A R P O W E R ENG.RAFAEL A.GONZALEZ SOTO,PE E-2 DESIGN@ENGIPARTNERS.COM ",'�ssoNpiEN�?c° (813)982-9001 PARCEL NUMBER: TSP87051 ""'nn,nn,•` 07:02:�8'04'0�' DATE: SHEETS: 833-888-3644 #EC13008093 1 1 3419-540-0191-000-9 07-16-2021 4 OF 9 LEGEND & SYMBOLS SOLAR MODULE UL 1703 CERTIFIED OBS ROOF OBSTRUCTIONS PORTRAIT MAX.SURFACE LOAD:112.78 psf ARRAY# LANDSCAPE MAX.SURFACE LOAD:50.13 psf xx.x MODULE# APPLIED WIND LOAD:51.38 psf STRING # NOTES: LG NeON R -INSTALL MID CLAMPS BETWEEN PV MODULES 360N1C-N5 66.9" MODULES AND ENDS CLAMPS AT THE 360W END OF EACH ROW OF MODULES. TRUSSES OR RAFTERS -ALUMINUM RAILS SHOULD ALWAYS BE NORTH 5'-116" FOOTING SUPPORTEON BBO HORE S DESHAN OF ONE OF • ROOF MOUNTS & RAIL SPLICE. N5'-1I16" EXISTING ELECTRIC METER ROOF SLOPE �40 .I PV DISCONNECT EXT. EXTERIOR PV MODULE WEIGHTED AVERAGE T IQ COMBINER BOX ROOF'S GENERAL NOTES: WORST CASE MODULE: OBS 1-CONTRACTOR/INSTALLER TO VERIFY ROOF CONDITIONS ZONE 1: 13% FOR PROPER INSTALLATION OF THE PV SYSTEM. ZONE 2r: 87% 2-CONTRACTOR/INSTALLER TO NOTIFY THE OWNER 29.59(0.13) + 54.63(0.87) = 51.38 psf IMMEDIATELY OF ANY ROOF DEFICIENCIES AND/OR REPAIR REQUIRED TO INSTALL THE PV SYSTEM. 3-FOR DOES NOT ASSUME ANY RESPONSIBILITY FOR THE ULTIMATE WIND SPEED 175 mph INSTALLATION OF ANY PV SYSTEM ON DEFICIENT ROOFS. NOMINAL WIND SPEED 159 mph EXT.• �xT. • ExT. Exr. 4-CONTRACTOR/INSTALLER ASSUMES ALL RESPONSIBILITY I INSTALL AS PER MANUFACTURER STANDARDS. RISK CATEGORY II EXPOSURE CATEGORY B ROOF SLOPE 21 ROOF INSPECTION NOTE: ROOF TYPE HIPPED W 'EXT. x PV MODULE IN LAYOUT IS CONSIDERED NON-EXPOSED AFTER MATERIAL ROOF TYPE ASPHALT SHINGLES Lu COMPLYING WITH THE FOLLOWING STATEMENTS BASED ON PRESSURE ZONE: 1&2 + 1 ASCE7-16: MEAN ROOF HEIGHT: 12.775 �T -NO INDIVIDUAL PV MODULE IS MORE THAN 0.5(MEAN ROOF PERIMETER WIDTH: 4.2 HEIGHT)AWAY FROM ROOF EDGE OR ANOTHER MODULE. Kn0.85 C7 ExT. -NO INDIVIDUAL PV MODULE IS MORE THAN 4 FT AWAY FROM KZT 1.0 Z ARRAY D ROOF EDGE OR ANOTHER MODULE. KH 0.575 a ARRAY A TILT=21° -INDIVIDUAL PV MODULE IS MORE THAN 1.5(MODULE LENGTH) VELOCITY PRESSURE(q)=0.60*0.00256* K V TILT=210 AZIMUTH=172°(S) AWAY FROM CLOSEST EXPOSED EDGE VELOCITY PRESSURE(ASD) 18.97 LL AZIMUTH=262°(W) W - OBS ARRAY C INTERIOR EDGE EXTERIOR EDGE ARRAY EQUALIZATION TILT=210 ASCE 7.16-29.4-7 FACTOR: Y8 =0.8 AT7AZIMUTH=82°(E) FACTOR:y =1.0 FACTOR:y 1.5 N _ c3.1 DESIGNED WIND PRESSURES: E E- FLAT p = qh (GCp)(YEVal) EXTERNAL PRESSURE COEFFICIENT Z1 0.7 -1.3 C211 EXTERNAL PRESSURE COEFFICIENT Z2e 0.7 -1.8 EXTERNAL PRESSURE COEFFICIENT Z2r 0.7 -2.4 W EXTERNAL PRESSURE COEFFICIENT Z3 0.7 -1.8 a- - A. - 1 INTERNAL PRESSURE COEFFICIENT 0.18 �� F M L G. � SOLAR MODULE A1.11 OBS ZONES PRESSURES INTERIOR EXTERIOR MAX. MAX. _ u11 ilk (PSF) PRESSURES PRESSURES SPAN CANTI- -TYP.SEE D-1 ExT. - a 4.G - (PSF) (PSF) (FT) LEVER(IN) A2.3 • EXT. EXT. I D. C 12r -28.08 -19.73 -29.59 4' 16" 0 0.4 -37.56 -27.32 -40.97 2' 8" ROOF MOUNTS B2 10 II LOCATED AT CENTER �/'� Cc ra -48.94 -36.42 -54.63 2' 8"OF ROOF TRUSS-TYP. / , i •M 0.2 -37.56 -27.32 -40.97 N/A N/A LA 1. p TOTAL ROOF AREA 3,906 s .-ft WOOD TRUSSES/RAFTERS T * * T LA 0 TOTAL MODULES: 32 LOCATION-INSTALLER B•4 I 2 10 100 ;()Da TOTAL PHOTOVOLTAIC AREA: 594.56 s .-ft MUST VERIFY IN FIELD 41�7 ^ WIND LOAD(PSF): -51.38 I- ICJ• Effec#ive Wind Area, f#2 TOTAL WIND LOAD LBS : 30,548.5 TOTAL ROOF MOUNTS: 104 ARRAY B TENSION FORCE PER MOUNT LBS : 293.7 TILT=21° AZIMUTH=172°(S) STRUCTURAL ROOF PLAN & PV MODULES LAYOUT N.T.S. DOCUMENT CONTROL DATE CAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: ISSUED FOR PERMIT 07.25.21 AC NT ENGIPARTNERS LLC TITAN SOLAR POWER FL STRUCTURAL MORIARTY PROJECTADDRESS: STRUCTURAL PLAN REV DESCRIPTION DATE CAD QC """""' Digitally signe 12221 N US HIGHWAY 301 % TITAN C.A.32661 ""P_GONZq�Fc,' 255 GIRALDA AVE ?°ex`�is�E"se.Zo; by Rafael A 104 NORTHEAST NARANJA AVENUE CORAL GABLES,FL 33134 ��Ny,,��83,�1,0,9�j' 'Gonzalez Soto THONOTASASSA,FL 33592 PORT ST.LUCIE,FL 34983 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: *F�SrAI 6 Date: S 0 L A R P O W E R ENG.RAFAEL A.GONZALEZ SOTO,PE S-1 DESIGN@ENGIPARTNERS.COM `s9o`.:<oaioS''ec'2021.07.26 (813)982-9001 PARCEL NUMBER: TSP87051 07:02:25-04'0 3419 540-0191-000-9 DATE: SHEETS: C OF 9 833-888-3644 °"""'°" #EC13008093 a�-is-zozi J We suppox9 PV systems We suppoet PV systems We suppoBe PV systems We suppoet PV systems z e r .rot s t r m z r w.esya,em. z: tsw..sr.t.m. z r .tsm..flOs O 1 Mechanical Properties _� � ['�' uulm°,.nl.lesHaa°m sn,ei¢sp lapel O© 00 -rel,asi°v:bo"d I.dlff;Naaawao-aL.: tble veles g 34s k.i 124p opal © © O O + Sa062�a°app„rovaINOAl2-0329.19, g 0.4]Ibs(Ir I0.600kg,ml 002 CrossRail End Clamp CrossRail Mid Clamp Sectional Properties °a,Px>„remar<ael,r..a mclgvml:lan:,m.enax aneuns,�!°�eel prn— iRL ms n x °rpagp,s¢be am r'me.The<urra Palcma'nce s.t43o;o31o.3res cm31 I mr,emggeau�ee°stlaq�stims.wwrrercar,.,xm,ranre — o.t°colas banes cmo] rtiwi I� +a_,.,lama g xeaa Bolt 1nICRUCS1-3p-47mm.M.— I.Vs nIx-sm;°n, 0.40so mz nozercmz nl..,xar 4zsl ea se covers.-s0mmsnereaatso-4smm ps0z-x lea ue oarx 9o-0rmm.scrum xe. ,mr Dnits:(mm,in alcN[ca.rk3e,amm.3meaNL3a 3mm 3 `we^ao L-Foot °vW :;� �,mrog P 39] [421a40] PSpe„glpwp°�°y,,,yyLn,,,wam„e°°1� 186 9 my p 9 s Clamn Su"tlolt °'� bwo,msuk I I mt.,e,ml a,emMnrcrman 'a4] Technical Detesl°:xm s NNssml Nm Technical Data Lases �5.a*M.iberi a"e�ve"e,w r'.meam°I reamn: 11 ,.Pea " w a°° a .ee°>• ma a�"ea arum q N „L s I r e m , Technical Data a w.enl° °a Imm�°a,et ac NMea. I M1„wre P 47r,m 3nem"aw mr m swn"r.w,a.. cnercxame,m ree necmmennvam uum n"m 0eeynu we enaasear la "r em.r"" r.ror."a Namabe� "."em"e naa S—gth 2ks1 ma¢e,ma ranamrer.m.,mera: N tlmr aPPmPmr° H rca4#Ireaa3P ur2msusmb sysran m�Flreena eonaln9 ° CanH�N'Mnxora:rgreorpnau;arertzunares real�upe Bcrn erea'm rcwerg. ° le module lramemee 50mm f,mal, "ra"rk"„"ei.ea 11111111111111 beM1a,.tne syarmleCom�NRena sl°ttee L-roml neretne eemeenrusi°"ee°merviesrnese wmpe"ents wzreyoe"malora.serumro[nes°bsmaecnNowwu Lure. ro re,aea�aemm<wwMlNleebacm vasore,eN N„coal lowed creel CampeabloN aaaan44-x,4e-x.4e xL eo.Nlwxao amee ucwr H m,v°IcepcatHsceun[osao,paceasrmwobnpvvmrare LAG BOLT PULL OUT CALCULATIONS SPAN TABLE FOR RT MINI ANCHORAGE SYSTEM Spruce,Pine, Per inch Thread Depth 266lbs LAG BOLT SS Lag Bolt 5/16"x 4" Min.Thread Depth 0'-3" CROSSRAIL END CLAMP Wood Strength x Thread Depth=Pull Out Strength ° 6s FLASHING 266 lbs.x 3 in=798 lbs. e ° 2 96 96 96 96 90 az 70 6o 12 46 4D 96 3 0 0 O O O O O 0 O O O O Allowable Pull Out Strength per Lag Bolt 798 lbs. z w 73 66 61 66 48 41 36 31 28 26 EXIST.2X WD. Max.Pull Out Strength Required per Lag Bolt 293.7 TRUSSES OR Lag Bolt Pull Out Strength Safety Factor z eo K 73 e7 e1 s. na 3s 33 z9 zs RAFTERS 11-7 46 41 ATTACHMENT DIAGRAM 2 ROWS OF RAILS PER MODULE �E��NG�N�P a 2egre� 3 s 6 6 41 o s o 4 1 O D71.20 egrees 1 96 96 96 96 96 96 96 96 9G as t39 �] 69 c25I°M PLACE BOLT 3 s� s6 s6 s� s6 ss s2 s ss w s3 a �EJ AT C.L.OF 1"21 2 se - - 1. - v. - - - yb - as TRUSS OR a o�g..°� 96 96 96 96 sa sa 6s O EQ. EQ. RAFTER i 9e 9e 9e 9e 9e 9e 9e 9e a9 9 I'll((� 2 96 96 I 96 06 96 81 70 61 64 48 42 `7 Degrees 96 1/4"ss 1s-s BOLT „P �v2 SECTION "A—A" 3 � � ag gl ,4 63 66 4. 42 37 33 1/4"SS SERRATED FLANGE NUT N.T.S. Portrait .r Ground Exposure Wind Speed 160 mph K2 SYSTEMS SEALANT Snow Load Category Panel Angle CROSS RAIL 00 one 1' 1 2e 2r 2n 3e 3r ... Flexible Flashing i certified b _linternational Code Council(ICC) Array Interior 69 69 69 57 57 57 54 --- - Engineered oo ASTM D 1761 wNr,mmr.NM Dimensions in(rum vx°a f B 20 t0 27 0 Ps L-FOOT --- ��� p ) Array Edge 60 60 60 46 46 46 44 ... RT2-DD-MINl8K ° s Vt Iw;vur PaNplN6 ° ° ab, $ P, Rac Specs.Lagpull-out(withdrawal)capacities(Ibs-out(withdrawal)capacities(Ibs -- DISTRIBUTED LOAD CALCULATIONS ... MINI=Pa.2e.a. -f�� n typical roof lumber(ASD) Lag Screw Installation Guidelines l sm.w',41 ea. Rafter installation 1. Determine location for the Mount on roof b drilling 2X4 RAFTERS 24' O.C. E.:nT-9uHl,o®. PV MODULES&RACKING WEIGHT=(INDIVIDUAL MODULE WEIGHT y g STAINLESS STEEL Lag screw specifications --- aPlionel.rem through the center of truss from bottom with 5/32"drill bit. -.. ,„80mmMwm;aaePr«mn°soeeor lw.e.+ab +3.5 LBS)*(MODULE QTY)_(43.18 LBS *(32)=7 381.8 LBS --- 9,s'xe„run,waeners amen mw."e�.°rr.,m«.re., 2. Mark mounting holes for Mount on underayment' Specific 5 ar-a nm,e�e„r,�L„.m..,aa. p /6"shaft,' RT MINI ,,,''' \ Mounting holes should be centered on the trusses. ASPHALT Moots R°ar rem to„role naeN Nam is PER SQUARE FEET(PSF)ARRAY LOAD=PV MODULES&RACKING 3.Drill y seal tt hole. SEE DATA SHEET ABOVE „P I-tha aaaa"n..Patina °I maMatarama. WEIGHT/TOTAL ARRAY AREA=1,381.8 LBS 1594.56 SQFT q.A sealant to bottom of Mount. graVlty per inch thread depth IL Is tM1e firs[PV m°untiny system witM1 Flexible Apply SHINGLES RaebinS—flea Noe lcc =2.32 PSF 5.Place Mount over roof underlayment with holes in root. Douglas Fir,Larch 0.50 266 M..el lwm"s Neb°eo Flezlble Flashhingg �� 6.Apply sealant to bottom of Mount,apply sealant to lag -•^'� yF� HENCE,ROOF WILL CARRY THE ADDITIONAL SOLAR SYSTEM screws and fasten Mount securely to trusses. Douglas Fir,South 0.46 235 NOTE: 5/16"SS LAG BOLT �o ' % `' 7.Apply additional sealant to top assembly to be sure all �l Deck insta ration LOAD SEAL BASE MOUNT TO EXISTING 5/16"SS FENDER WASHER penetrations are sealed. Engelman Spruce,Lodgepole Pine 0.46 235 ROOF UNDERLAYMENT WITH ROOF / f r ( SR 1650 f&higher) 100%waterproof SEALANT AND MEMBRANE I "sce'-'6v°'°" `a' a 1 sbeaai°ewa,e<r Notes:(1)Thread must be embedded in the side grain of a Trusses or other structural =o°o2seNe N.I Na v22 Hem,Fir,Redwood(close grain) 0.43 212 ""'"a 00 M1iI member integral with the building structure. car-,e Imea°rePr Hem,Fir(North) 0.46 235 1:0:F (2) Lag Bolts must be located in the middle third of the structural member. Q (3) These values are not valid for wet services. (4) This table does not include shear capacities.If necessary,contact a local engineer to Southern Pine rl«m 0.55 307 -� specify lag bolt size with regard to shear forces. a earlmpnl',mm rice 716 maPe ar.rree,a as°mmM.and apace maPa m 1 all - (5) Install lag bolts with head ad washer Flush to surface(no gap).Do nor over-torque. - Spruce,Pine,Fir 0.42 205 1 H I N■^_L E R F M N T DETAIL DATrum °�pP�n (6) Withdrawal design values for lag screw connections shall be multiplied by applicablem aaamm w ntl°,�83 1 S V O O O & A RoOfTech adjustment factors if necessary.See table 10.3.1 in the American Wood Council Nos th n a w°re°«e°Nd.—in. m>aaa. Spruce,Pine,Fir www.roofor Wood Construction. m I° (E of 2 million psi and higher 10620 Treana Street,Suite 230,San Diego,CA ONN.T.S. 1 858.935.6064grades of MSR and MEL) 0.50 266 k aramma are.wally a,apmaa th W a;arxbpl a DOCUMENT CONTROL DATE CAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: ISSUED FOR PERMIT 07.25.21 AC NT ENGIPARTNERS LLC ,,,+"""" Digitally signs TITAN SOLAR POWER FL SEAN MORIARTY GONIq'"' PROJECTADDRESS: RACKING PLAN REV DESCRIPTION DATE CAD QC ,.� p. (F''a,, C.A.32661 ,c,cr;:vyceNSF:Zso' by Rafael A 12221 N US HIGHWAY 301 % TITAN 255 GIRALDA AVE ;p:' e3to4 =GODZdI2Z Soto 104 NORTHEAST NARANJA AVENUE CORAL GABLES,FL 33134 _* � *` THONOTASASSA,FL 33592 PORT ST.LUCIE,FL 34983 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: STATE i o'Date: S-2 DESIGN ENGIPARTNERS.COM �'.Po, :SoaTo4'�+,p`Qc�2021.07.26 813 982-9001 S 0 L A R P 0 W E R TS P87051 ENG.RAFAEL A.GONZALEZ SOTO,PE �.,SS/ONAL EN�„c ( ) PARCEL NUMBER: 07:02:37 04'0 SHEETS: 3419-540-0191-000-9 07-16-2021 6 OF 9 833-888-3644 #EC13008093 .1 LG \ �, Mechanita3 P r[)es Electrical rde5 STC' ,I Life's Good �_+{ .}II 4 Cel Cordiglvalion 60 Cr3s(6.10) Mudul Type w3sm C-- L.Ca4s3M1C-Ns LC1360M1G7115 r :I CeIE Ma1ov LG Mawmurn P.-Pmax 11M10 350 35S 360 Cell Propervev Monoo-ysmlme IN-type MPv volwge v."M 343 347 35.1 2 YEARS ' N�befr" 3usbas 12EA MPPCuentlmpp(A) Ill ,OZ' 1019 Q_ \a ! • Oimertswns(L x W x Hj 1700 x 1016.4o mm Open Circuit voltxJe SicM 41.4 41.5 41.5 / 4 From lead lot) SAW P. Short Cimat Curent1w 4A) 10.76 10A0 1M 1L and���a�e e RllAad l 40MPa MlEffriercy(76) 2U 206 2118 weight 18kg Op-"v-9—rp •40-+90 Cwrrrecaw Type GeruineMC4,IP66 Ma�drrarm sYger°VdggeM 1g0p IFS) (Male PV-1C5'r4}(Fmrale PyK814] �.,,Ser:es frae Ra[irgfA) 20 kealdw+Sox Mwrdr 3 bypass des puwerTolerance{71i} 0-+3 Lull of Cables 2 A 1000 mm Glass(Matciai) Tenpaiec{G41ss wqh AR Cwtirg TT.(Sons 7es C w,pl)measured lard det>•r—d W Elecamks a!Its sale and aw-d re disr.rernn LC NeONO2 � Anodlsedalwnlnwnrntl+protectNemazt n� �. � K 41ar><ooavrg Electrical PrWerl NMOT' Certlfltation5 and Warm ModAeType LG350N1C•Ns LG355N7C•NS LG360N1C-M5 ISO 9001,15014001,15050001 Fls+drlren Fboev Rn•I(Nr) 261 266 27o LG 350I355 36DN1 C-N5 IEC6,215.„•,•1n-2D,r 32-2 326 330 CertiCicaliorrs IEC51730.1/i2016 MPPCwiltirgp(A) A15 0-17 620 THE HIGH PERFORMER o"WISMI op-G 41:100ltorvocm 390 391 392 Fire Rarhg Class C(UL790) _Shot Cite[Cwlcrt hl am Ill a71 Pmdurl Warranty 25 years _ 'NMOT(N.-AM°dule Op°rapng Terpe-,irwril WWar"WCWhrr',Will"Waul 7AL UP TO y Oul Warranty of Plr�l -W,p-d I-14 5{K•r r/um AM 15 • • ` 1 MODULE (M—r—r role.xas±3%) 17�Vl Dimensions(al '1)1 5t rae 9814 2)AIm 16t year 433%w1mal ergrailwm 3)90.099G for 25years LoN Frame slat Frame 10.0 10.0 Awards Received By LG Solari' � � Temperature CharKwi stits fin+. KUM 42±3"C o o Unitmm I lip st."(1 pv r yop 8AAND Pv l gar a�,wn w �,�ennNP ry II 1'OA 811ANb PV -• "l� 4 S Voc -0.16WY + M ]sc 0-03 W'C 2020 2019 20i8 2017 2016 1 ` ` 29.0 225 1 sotaA Current-Voltage characteristics at vriaus irlacrlllrim levels Is xorsrwre s,ae1 "' fl]fiA rs-ao•a.e IPnranc•pet..e�-nGr«,ndmq&MwmungMNnl romk 0-in Horan I Ynp icl r. THE NeON®2-THE PANEL OF THE FUTURE AVAILABLE TODAY � 10-61�1 The LG NeONO 2 has seen many improvements in the past years,from longer warranties to lower degradation.This panel Is "°""""q"°" `1 .l h u,on•� t ideal for homes seeking a visually pleasing solar panel and for roofs where space is tight or where future system expansions J, amu are considered e.g.to incorporate battery storage_ The LG NeON®2 panels with their double sided cells and CELLO technology absorb light from the front and the back of them F l? cell.This technology sets a new standard for innovation and was recognised with the Photovoltaic Innovation Award at the s 'loltage ivl s Intersolar Industry Event in Germany.LG also won the 2016 Intersolarawaird for our new NeCIN BiFacial range. Currant-Voltage.characteristics ar vanuus Dell temperatures o 8 � � Great Visual Appearance 25 Years Product Warranty(Parts&Labour) " q LG NeQN®2 panels have been designed with appearance FTXI The LG product warranty is many years longer than W a 9 in mend.Their black cells,black frames and thinner wire many competitors standard 10 or 12 years The busbars give an aesthetically pleasing uniform black Warranty is provided by LG Electronics Australia and appearance-Your home deserves the LG NeONm 2 New Zealand-The warranty includes replacement, tabour and transport. More Power per Square Metre 939'np Improved 25 Year Performance Warranty a M R e _ Tenpuatws('l lIS NeQN®2�S 36OW are asimAar physical size to '' � The initial degradation of the module has been improved many competing 330W panels.This means with the LG from-3%to-2%,in the 1 st year and the annual rate of NeON®2 360W et 95A more electricity LG E e ks nc Group y Pry Lrtl LG E4Hlrrnas rDr Wil spec rrx;asnns a r cui ti s[°rr 1n i,• you g ty per square degradation has fallen From-0.7%!year t�-0-33Rb/year ■ 4� ■ Sdar Business Group SnWr Busnrss pwrsinn ywtMut pror nonce ftow metre than a 330W panel.So you can install more kW of thereafter.This brings an 90.08%warranted output after (9 �� 2 wonriorl Orw.Eastvm Cm.k.NSW 2166 -W-Swk5mx Vo s7emT I lF Dace13V2020 QN® solar on your roof with the LG Ne 2 25 years,compared to 80.7%for many competing panels Ph r 300 r 52 179 128.1'Irr 4aem,Veorgda.rgpolLifes Good E Mao soiarsales(�lgeromau sew107336.Ko Copyryhc02020LGEkctmrm Made in Korea Call LG Solar on 1 300 152 179 www.[gene rgy.co m.au '""'y`°mom """�'rArt gldhal,lrn Dens An e4hrs resaned DOCUMENT CONTROL DATE CAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: ISSUED FOR PERMIT 07-25-21 AC NT SEAN MORIARTY PV MODULES DATAS H E ET ENGIPARTNERS LLC TITAN SOLAR POWER FL REV DESCRIPTION DATE CAD QC ,.�"` ""'. Digitally sign PROJECT ADDRESS: �aNZA * TITAN C.A.32661 °`�`.P�ii;EniseFrmo'-s by Rafael A 12221 N US HIGHWAY 301 255 GIRALDA AVE e: 104 NORTHEAST NARANJA AVENUE 83104 =Gonzalez Sot CORAL GABLES,FL 33134 i,s � ,t E THONOTASASSA,FL 33592 PORT ST.LUCIE,FL 34983 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: .1 $Tp 'Date: s O L A R P O W E R ENG.RAFAEL A.GONZALEZ SOTO,PE D- DESIGN@ENGIPARTNERS.COM '-9o''•:Son1v,4'�¢c`2021.07.26 (813)982-9001 TSP87051 PARCEL NUMBER: DATE: SHEETS: 7 OF 9 ,,, ,,, ' 833-888-3544 07:02:47-04'0 #EC13008093 3419-540-0191-000-9 o�-1s-2o21 Data Sheet Enphase IQ Combiner 3 Enphase Networking MODEL NUMBER IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy'"printed circuit board for integrated revenue grade PV X-IQ-AM1-240-3 production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Enphase Mobile Connect'" CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01(3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%). Enphase The Enphase IQ Combiner 3- with Enphase CT-200-SPLIT 'Consumption monitoring is required for Enphase Storage Systems IQ Envoy'" consol(dates Interconnection Wireless USB adapter Installed at the IQ Envoy.For communications with Enphase Encharge'"storage and Enphase Q Combiner 3 COM MS-KIT-01 Enpower"smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner" equipment Into a single enclosure and and allows redundant wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. (X-IQ-AM1-240-3) Streamlines PV and Storage Installations by BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 providing a Consistent, pre-Wired solution for BRK-20A-213-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity-one pair residential applications. It Offers up to four XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) 2-pole Input Circuits and Eaton BR series XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS busbar assembly. Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Smart Max.continuous current rating(input from PV) 64 A • Includes IQ Envoy for communication Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included L and control Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy L. Flexible networking supports Wi-Fi, MECHANICAL DATA 1 Ethernet,or cellular �l� I Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). Optional AC receptacle available for PLC Weight 7.5 kg(16.5 Ibs) ill —L bridge g Ambient temperature range -400 C to+460 C(400 to 1150 F) LI Provides production metering and optional consumption monitoring Cooling Natural convection,plus heat shield illl V Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors Simple 60 A breaker branch input: 4to 1/0 AWG copper conductors 1f Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and round: 14 to 1/0 copper conductors • Reduced size from previous combiner 9 PP I Always follow local code requirements for conductor sizing. Centered mounting brackets support single tII = Altitude To 2000 meters(6,560 feet) rr stud mounting M k- INTERNET CONNECTION OPTIONS • Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC Integrated Wi-Fi 802.11b/g/n plug-in breakers(not included) Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) • 80 Atotal PV or storage branch circuits Cellular Optional,CELLMODEM-01 (3G)or CELLMODEM-03{4G)or CELLMODEM-M1{4G based LTE-M) (not included) COMPLIANCE Reliable Compliance,Combiner UL 1741, CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Durable NRTL-certified NEMAtype Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 3R enclosure U� Five-year limited warranty UL listed To learn more about Enphase offerings,visit enphase.com LISTED ©2018 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the E N P H AS E. trademarks of En phase Energy,Inc. E N P H AS E. To learn more about Enphase offerings,visit enphase.com `/ 2019-11-04 V DOCUMENT CONTROL DATE CAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: ISSUED FOR PERMIT 07-25-21 AC NT SEAN MORIARTY SMART MONITORING DATAS H E ET ENGIPARTNERS LLC Digitallysigne TITAN SOLAR POWER FL REV DESCRIPTION DATE CAD QC PROJECT ADDRESS: C.A.32661 `;Ppe:.1l sF:Z,=; by Rafael A 12221 N US HIGHWAY 301 * TITAN 255 GIRALDA AVE - ��e3ioa GOnZdI2Z$Ot0 104 NORTHEAST NARANJA AVENUE CORAL GABLES,FL 33134 *�,;D-'!��' *= THONOTASASSA,FL 33592 PORT ST.LUCIE,FL 34983 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: srnTE� =Date: S 0 L A R P O W E R ¢-= ENG.RAFAEL A.GONZALEZ SOTO,PE D-2 s ''`(ORID 2021.07.26 q DESIGN@ENGIPARTNERS.COM ''',,°FSSiomn�F��,o` (813)982-9001 PARCEL NUMBER: TSP8705 I DATE: SHEETS: 07:02:54-04'0 3419-540-0191-000-s 07-16-2021 8 OF 9 833-888-3644 #EC13008093 Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Region:AMERICAS Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V 1 Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A I Enphase The high-powered smart grid-ready Overvoltage class DC port II II Enphase IQ 7 Micro' and Enphase IQ 7+ Micro" DC port backfeed current 0 A 0 A 1 Q 7 and I Q 7 dramatically simplify the installation process while PV array configuration 1 x 1 ungrounded array,No additio I DC side protection required, •� AC side protection requires max 20 per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Microinverters Part of the En hase IQ S stem,the IQ 7 and Peak output power 250 VA 295 VA p y Maximum continuous output power 240 VA 290 VA IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range' 240 V/ 208 V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy', Enphase IQ Battery'", and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Enlighten'" monitoring and analysis software. Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 warranty of up to 25 years. Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 9T0% 97.0 1/ 97.0% 97.0 MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connectortype(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connectortype(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Lightweight and simple Adaptors for modules with MC4 or UTX connectors: Faster installation with improved,lighter two-wire cabling PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes Optimized for high powered 50-cell and 72-cell*modules Pollution degree PD3 More than a million hours of testing Enclosure Class 11 double-insulated,corrosion resistant polymeric enclosure Class II double-insulated enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor UL listed FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Smart Grid Ready Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break ' Complies with advanced grid support,voltage and disconnect required by NEC 690. frequency ride-through requirements Compliance CA Rule 21 (UL 1741-SA) Remotely updates to respond to changing UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, grid requirements CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Meets CA Rule 21 (UL 1741-SA) and DC conductors,when installed according manufacturer's instructions. U� *The IQ 7+Micro is requiredto support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at hops:J/enphase.com/en-us/supportlmodule-compatibility. 2.Nominal voltage range can be extended beyond nominal if required bythe utility. 3.Limits may vary.Refer to local requirements to define then umber of microinverters per branch in your area. EN PHAS E. To learn more about Enphase offerings,visit enphase.com EN PHASE. To learn more about Enphase offerings,visit enphase.eom `� ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. a 2018-05-24 DOCUMENT CONTROL DATE CAD QC ENGINEER CONTACT INFORMATION ENGINEERING STAMP CONTRACTOR CONTACT INFORMATION CONTRACTOR LOGO CUSTOMER: SHEET NAME: ISSUED FOR PERMIT 07.25.21 AC NT ENGIPARTNERS LLC TITAN SOLAR POWER FL SEAN MORIARTY REV DESCRIPTION DATE CAD QC ,..��•"""""� Digitally signed INVERTER DATAS H E ET PROJECT ADDRESS: C.A.32661 P.00nza�EZo,, 12221 N US HIGHWAY 301 % TITAN 255 GIRALDA AVE ,d°�e4: S�ErvSF..:so; by Rafael A 104 NORTHEAST NARANJA AVENUE e3ro< ' `_Gonzalez Soto CORAL GABLES,FL 33134 •. •= THONOTASASSA,FL 33592 PORT ST.LUCIE,FL 34983 PROJECT ID: ENGINEER OF RECORD: SHEET TITLE: '�;v Srp� 'Date: s 0 L A R P O W E R .I ENG.RAFAEL A.GONZALEZ SOTO,PE D-3 DESIGN@ENGIPARTNERS.COM 0703:7'204'00' (813)982-9001 PARCEL NUMBER: TSP87055 I DATE: SHEETS: """.,,„..•• 3419-540-0191-000-9 07-16-2021 9 OF 9 833-888-3644 #EC13008093