HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET Vic L PC IE,
S T. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code-Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of Attachments Required
Roof System the Permit Application See List Below
Form
Low Slope Application A, B,C 1,2,3,4,5,6,7
Prescriptive BUR-RA5 150 A, B,C 2,4,5,6,7
Asphaltic Shingles A, B, D 1,2,4,5,6,7
Concrete or Clay Tile A, B,D, E 1,2,3,4,5,6,7_
Metal Roofs A, B,❑
JWood Shingles and A, B, D IA4,5,6,7
(Shakes
Other As Applicable 1,2,3.4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16,or if applicable,RA5 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations(Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RoofinfoFeb21 Rev Feb 18,2021
ST, LUCIE VORKS
Section C(Low Slope Roof) Surfacing:
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone V:—"oc @ Lap,It Rows_®_°o0
(If a component is not used,identify as"NA") Zone 1:_..."oc @ Lap,#Rows_®—"0
System Manufacturer: Zone 2:—"oc @ Lap,#Rows_®—ao
Zone 3:_"oc @ Lap,#Rows—@_oo
Product Approval No.:
Number of Fasteners Per Insulation Board:
Design Wind Pressures,From RAS 128 Or Calculations: Zone 1'--Zone 1:—Zone 2'—Zone 1—
Zone P:_Zone 1:_Zone 2:_Zone 3:_ Illustrate Components Noted and Details as Applicable:
Max.Design Pressure,from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: Flashing, Continuous Cleat, Cant Strip, Base Flashing,
CounterRashing,Coping,Etc..
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: Flashing,Component Material,Material'Thickness,Fastener
Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: Comply with RAS 111 and Chapter 16..
Slope:
Anchor/Base Sheet&No.df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material: FT'
Insulation Base Layer:
Base Insultation Size and Thickness: Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: FT,
Top Insulation Fastener/Bonding Material:
Mean
Base Sheet(s)&No.of Ply(s): Roof
Base Sheet Fastener/Bonding Material: Height
Ply5heet(s)'&No.of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
ST. LUCIE WORKS
Section D(Steep Slope Roof System)
Root System Manufacturer: JA TAYLOR ROOFING 5V CRIMP
Notice of Acceptance Number:FL#17443.1
Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations):
Zone 1:'5�one 2e: -57 Zone 2n:-91 Zone 2r: -91Zone 3er91 one 3r:-128
Deck Type: PLYWOOD '
Type Underlayment PEELS STICK-OMNS CORNING POLYGIASS MTS FL.15259.1
Roof Sbpe: .
5 12 Insulation:
Fire Barrier: -
Rbige Vent�afion? Fastener TypB&SpaCUIg: 6'FIELDIi"PERIMETER,RO RING 8HANKNAI4S
Adhesive Type:
Type Cap Sheet
Mears Root Heigtll: 15' FT Roof Coveing: METAL
Type&Sim Drip 2
Edge:
ST. LUCIE WORKS
Section E(Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mrwith the values from Mr.If the Mrvalues
are greaterthan or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _xll_= _)-Mg:_=Ma_ Product Approval M
(Zone 2e: _x%_= _)-ft.—=My_ Product Approval Mr
(Zone 2n: '_XX_= _)-Mg:—=M®,_ Product Approval Mr
(Zone 2n _Xil _= -Mg:_=Me� Product Approval Mr
(Zone 3e: —xl—= 1-1146—=M�— Product Approval Mr
(Zone 3r: =Xk _ ) Mg:_=Mm— Product Approval Mr
Method 2"Simplified Tile Calculations Per Table Below"
Required Moment of Resistance(M,)From Table 8elow_Product Approval W4_
Mr required Moment Resistance'
Mean Roof Height Roof Slope 15' 20' 25' 30' 40'
2:12 t34.4] 36.5 38.2 39.7 42.2
3:12 34A 36.0 37.4 39.9
4:12 �30.1
32.2 33.8 35.1 37.3
5:12 28A 31.6 32.8 34.9
28.0 29.4 30.5 32.4
7A2 24.4 I5.9 27.1 29.2 30.0
-Must be used in conjunction with a list of moment based tile systems
• For Uplift based tile systems use Method 3.Compare the values for F'with the values for F,If the F'values are greater than or
equal to the F,values,for each area of the roof,then the tile attachment method is acceptable.
Method 3"Uplift Based Tile Calculations Per RAS 12T
(Zone 1:�x L=x W:=__-j-W:_cos r_-Fri Product Approval F'
(Zone 2e:Jx L=xW=_)-W cos r=Fa._ Product Approval F'
(Zone 2n:_x L=x W= )-W:_cos r=F,u"_ Product Approval F'
(Zone 2r._x L_=xW:= -W:_cos r=Fa,_ Product Approval F'
(Zone 3e:_x L=xW:=_)-W:_cos r_=F,a., Product Approval F'
(Zone 3r._x L=xW:=_ -W:_cos r_=Far_ Product Approval F'
Where to obtain Information
Description Symbol Where to find
Design Pressure Zoom 1,2e,2n,2,3e,3, From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height H lob Site
Roof Slope B Job Site
Aerodynamic Multiplier a Product Approval
Restoring Moment due to Gravity Mc Product Approval
Attachment Resistance Mr Product Approval
Required Moment Resistance Mr Calculated
Minimum Attachment Resistance F' Product Approval
Required Uplift Resistance Fr Calculated
Average Tile Weight W Product Approval
Tile Dimensions7-:7 L=length W=Width Product Approval
All calculations must be submitted to the building official at the time of permit application.