Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS RegulationBusiness & Professional BCIS Home Inter Re9lstration - Hot7opics Submil Surcharge Slats&Facts Publications Contact us BCIS site Map Links Search Use r 'L�'� Product Approval USER:Public User Fr ct Ap M 1 en >pro ct or AlaplEca i rt Se ch>_gpp Application Detail in In• FL# FLS259-R31 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 Ext242 ma[pert@polygiass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative TECH REP Address/Phone/Erna[[ 1111 West,Newport Center Drive Deerfield Beach,FL 33442 (866)802-8017 uspolyglasstechnical@ polyglass,com Quality Assurance Representative QA REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888)410-1375 uspolyglasstechn[cal@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Profess[onai Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/21/2027 Validated By John W. Knezevich,PE Validation Checklist- Hardcopy Received Certificate of Independence FL5?59R31 ,COI 20�❑ 01 Cal N;r MINEN.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 FM 4474 2011 FRSA/IHI,Sixth Edition 2018 UL 1892 2015 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Opdon D Date Submitted 10/22/2020 Date Validated 10/26/2020 Data Pending FBC Approval 11/01/202O Data Approved 12/15/2020 Date Revised 12/21/2020 Summary of Products FL♦ Model,Number or Oe 1ptbn Name 5259.1 Payglass Roof Roofing undedayments Underlayments Limits of Use Installation Instruotlona Approved for use in III No FLS259 RU 11 2020 QI SO FINALVIDLYGLINSS UNDEALAYMENTS EL5259- Approved for use outside III Yes R32_pat Impact Resistant:N/A Varifietl By: Robert Nieminen PE-59166 Deal pressure: +N/A/-622.5 Created by Independent TMM Patty:Yes Other: 1.)The design pressure in this Evaluation Report application relates to one particular FL5259 R31 AE 2029 09 30 FINAL R Pi ASS UNDERLAYMENTSFLU59- underlayment system for use in tile roof 1132.pQ[ systems. Refer to ER Section 5.8.3 for other Created by Independent Third Party:Yes systems and associated maximum design pressures.2.)Refer to ER Section 5 for other limits of use. Ba[M O 2601 shor Smn¢aoee Tallaha a FL 32399 phone:B50407 1020 Tb¢Sr¢h or sonde is an ANEEO employees ::Aux_ __ very OnI Fluids laws email address are their reminex fyou tlo net wum,rau mall addns relOa d in response to a pubbe-rtWN¢ratified,Eb no[eadele¢rynlc mall to MIs a ed,Wanda,mntttt Me Wi by phone of by WWWW,nal mall,if you have any Whoodons,pleatt coned,850 487.1395.'pursuant to Sadden es$.275(1), horde saturated,ene[twe Otluber 1,2012,II[emame learned under charter 455,F.S.must pmvMa We peasantry won an eIDall uperns if they have one.The emane pwNM may,ceus[e by areas mmmumgticn wM one limns.xmvever email decamp arc Want nmM.if au do not when to supply a persarel address,please Preside the department with an ema l aeere a which ran be made avdm We to the puunr.m daMrmme Ifyou am a imnse,under cnapt[v ass,es.,please dice Use, areduct llppwval Ac spo: ®471 ® o® Credit Card Safe NEMO I etc. Certif imte of Authoriiction#32455 353 Christian Street, Unit#13 Oxford,CT 06478 0 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT Polyglass USA,Inc. Evaluation Report P12060.02.09-R27 1111 West Newport Center Drive FL5259-1131 Deerfield Beach,FL 33442 Date of Issuance:02/24/2009 (954)233-1330 Revision 27:09/30/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the r Edition(2020)Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMKIANtE: This Evaluation Report is valid until such time as the named product(s)changes, the referenced Quality Assurance or production facility location(sl changes,or Code provisions that relate to the products)change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review of its Evaluation Report relative to updated Cade requirements with each Code Cycle. ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words"NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 17. Prepared by: Robert J.M.Niem{nen,P.E. %ar. 4E .� • The retained.aaam wa s a nmimd s aat W tighten,idea i-,P.E.on Florida Resistance No.59M,Florida DCA ANE1983 72.S 'yk;;.•` 09/3012020.This does not serve as an eledronicall,signed dxumem. CERTFFlr VON OF INDEPENDENCE: 1. NEMO ETC,LLC does not have,nor does it intend to acquire or will It acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,ILC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does nothave,nor will acquire,a financial interest In any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC not Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02M9NEMOEMUC ON EMO I etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Subcategory: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the r Edition(2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. STANDARDS:2. Section Prime Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.3.1 Wind resistance UL 1897 2015 1507.1.1/R905.1.1 Material standard ASTM B226 2009 1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015 R905.1.1,R905.2.8.2 1501.3.3/R905.3.3 Material standard FRSA/Ml,Stith Edition 2018 1507.11.2/R905.11.2 Material standard ASTM D6163 2015 1507.11.2/R905.11.2 Material standard ASTM D6164 2011 1507.11.2/R905.11.2 Material standard ASTM D6222 2011 1507.11.2/R905.11.2 Material standard ASTM Di 2015 TA5110 Accelerated Weathering ASTM U798 2011 3. REFERENCES: Enminanon gereRnce 20 AIM Eammnbn Releren" pope ERD ITST W49) Wind Uplift 11757.08.01-1 N/13/2003 ERD(TST 6499) 30/90 phWail5 PLYG-SC11900.03.17 03/10/7017 Cap OST 6049) Wlnd Uplift 11"6.06.01 Ol/16/2W3 ERO ITST E049) TM 103 PLYG-SC12115.08,17 08/08/2017 ERD CM adds) Wind Uplift P1740.01.07 01/N/2007 ERD(T5T60K)) TA51m PLYG-SCM035.0417 10/31/2017 EW(TST6049) ASTM D1970 P5130.04.07-1 04/11/2007 FM(TST M71 Wind UplRt 3004091 Ol(Sl(2000 ERO(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ICC-ES(Il 23961 IBCcompliance ESR-1697 W/01/2019 ERD CST 6W9) Wind Uplift P30540.11.09-111 11/30/2009 M-D(CER1592) NVNZcompliance NOA 17-0614.22 01 ERD UST 6049) Tensile Adhesion P11030.11.09-1 11/30/2009 Mn CST 25D81 ASTM Miss l%20417A 04/01/2008 ERO UST 6049) Wind Uplift 1:11030.11.09-2 11/30/2009 MEMO(TSTGD49) ASTM D19M "LYG-M-O".03.18 03/29/2028 ERO(TST EW9) ASTM M977 P13030.11.09-3 11/30/2009 MEMO(TST E049) Wind Uplift 41--PLYG-18d3AL19 01(11(N19 ERD(M 61 ASTM D1970 P33360A6.10 06Q5/N10 MEMO 016049) ASIM 06163 45-PLYG-16G02.0L19-A 01/24/2019 ERD(TSTG049) TAS 103 P333>0.03.1] 03/02/2011 NEMOUST6(ad9) ASTM D6222 A PLYG-SB-002.05.19-c 051 ERDnSTW% Tamils AtlMaion P33370A4.11 M12612011 MEMO rM seas) ASTM D1970 41-PLYG-11s$UD400.A W110/2019 BE UST 6049) ASTM 01970 P37300.10.11 10/19/2011 MEMO UST6049) TAS 103 44PLYG.18GG4.10.19G 10/08/7019 ERD 05T 6f149) TAS 103 P40390.08.12-1 OV06/2012 MEMO(TST 601 T/5103 45-PLYG-181 10.19-1 10/0B/2019 ERDOST6W9) Tensile Mhai.n PiHON. 8.12-2 W/07/2012 MEMO OSr 6049) TAS 103 45-0LYG48G04,10.19-1- 10/W/2019 ERD(TST WE) Tensile Mhesnon 041420.09.12-3 09/11/2012 MEMO UST sops) TAS 103 4j-PLYG-I9-SSUDL-OA N/10/2019 ERD(TST Was) Wind UpBft P3968003.13 031MJ2013 NEMOOSTW49) TASUS 45.K1G113-OM.12.19-F 141BI2019 ERD OST sold) MTM DB70 P45370.dd.13 04/26/20D NEMOOST6049) TAS 103 4}P1YG-19-SSUDL-02A 01/02/2020 ERD OST 6W9) Wind Uplift P1730.02.0-112 M/29/2013 MEMO OST 6019) ASTM 01970 45-P1YG-18G Dft.20M 01/14/2020 ERD(TST 6W9) Wind Uplift 11757.M.D3-1-R3 04/30/2013 NEMO(TST6049) ASTM 01970 44PLYG48GddO1ROJ: D3/14/NN ERD UST Gea9) ASTM M164 P37590.03.13-3A 05/06/2013 MEMO UST 6049) TAS 203 4SPLYG,18-004.W.20.A M/16/2020 ERD(1ST 604% ASTM M509 P37590.0319-1-R1 061 REh10(TST60491 ASTM 06164 45-PLYGAE-omoS20.B OIJIS12020 ERD(M Ease) Wind Uplift P41630.0B13 (18/06/2013 MEMO(m 6049) ASTM 06222 45-PLYG48-0M.U,Ui-a-al 01/07/2020 ERD OST 6049) A5TM DMD1 P45940.09.13 09/W/2013 MEMO M adds) TA5103 PLYG-SC15855.0SWA 05/29/2020 ERD OST GW9) Wind UplM PI1751.05.03Jn 11/26/2013 NEMOW6049) TAS 103 4j-PLYG-20-SSUDL-01 07/06/2020 ERD(TST seas) Wind Uplftt P12781.11.0i 11/26/2013 NEMOm5T6W9) ASTM Di 44-PLYG49SSMBB-0S.A 07/23/2020 ERD(TST 6049) a0/90 physicals P45270.05.14 MJ1212014 MEMO CST 6049) ASTM dd798103623 41-PLYG-I9-SSUDL-05A 01 ERO UST E049) Tenaileadheslon 60201 09/08/2014 MEMO(W 601 ASTM 0070 4j-PLYG-20-SSUDLG5.A 09/30/2020 ERD OST 6049) Tensileadhesion 6020.09.146 D9/W/2m4 MEMO OST 6049) TAS 103 4j-PLYG-20SSUDi 09/30/2020 £RD UST 6M9) Tensile adhealon P46520.10.14 1010312014 NEMO(M adds) TAS 103 41-PLYG-20-SSUDL-11 m/30/7020 MEMO ETC,Luc. Evaluation Report P12060.02.MR27 6oMkoreojapOmftnAft 37435 7TM EDITION 12020)FBC NON-MVNZ EVALUATION FU259-Ml Polyglaes Roof Underlayments Revision 27!09/30/Zo20 Page 2 of 27 ONEMOjeft. IEab limminatbn Henna DW 40 Nmmeutle0 garemam Pa" ERD UST 6(349) AS7MD1970104793 P43290.10.14 30/17/2014 PRI(TST 5878) Textile Adhesion PR101111 M/08/2002 ERD(r5T 6M9) TAS 103 PLYGSC7550.03.15 03/24/2015 PRI(Tar SSM) TAS 103 PUSA01"M1 O/14/2W3 ERO(TST 6(M9) Tenella.dheslon P40390.04.15 04ftGA015 PRI(MM781 TASlfl3 PUs4035-02-01 09/29f1006 ERD LTST Will TAS US P44360.10.14-83 05/18/2015 PRI(TSTS878) TA5303 PUS4-055.02-02 12/10/2007 ERD(IST60AU wind Uplift PLYGSC9905.05.161 05/17/2016 PRI(TST 078) A.STMD6212 PUMA 1-02-02 01/28/20M ERDI1ST6MM) ASTM Eaton PLYGSC10130.06.161 D6/27/2016 PRI RtT SA78) ASTM D6164 PUSH-088-02-01 07/29/2009 ERD(TST6049) Tensileadhesion PLYG-$r10130.06]62 06/27/2016 F.W.USA P/LAfOdaWt Mulo-Mde Cross us 03/0112MB par TST 6M9) TAS 103 PLYGSCUA30.06.16-3 06/27/2016 PoiWaaa USA Materials Affidavit Potysud:CnmpouM oviatzoll ERD(TST 6049) ASTM D1970/N798 PLYGSCBW0.07.16 07/16/2016 UL(QUA96251 QuaIItYContral Service Coidirmaeon(FL) 09/13/2018 ERD(TST 5049) wind Uplift PLYG-X12025.10.16 10/12/2016 UL(QUA9625) Quality Cor., Servim Confirmatlon(Tx) 11/07/2019 ERD(TST6M9) IM103 PLYGSC33040.12.16 IZ12712016 UL(QUA9625) Qv.1rvcdrd.I Florida KIS Current DESCRIPTION:4. PRODUCT Product Material Standard PlanHs) Description 4.1 Elastobase ASTM D6163 FL Fiberglassreinforced,SBS modified bitumen base sheet 4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet 4.3 Elasto8ex S6 G ASTM D6164 FL,PA Polyester-reinforced,SB5 modified bitumen cap sheet FRSA/TRI 09-18 4A Elastoflex S6 G FR ASTM D6164 FL Polyester-reinforced,S95 modified bitumen cap sheet FRSA/TR109-18 4.5 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick duai-layer rubberized asphalt waterproofing membrane,fiberglass reinforced,with a polyester fabric surface 4.6 HydraGuard Tile Pro ASTM 01970 FL Nominal 60-mil thick dual-layer rubberized asphalt FRSA/TRI 09-18 waterproofing membrane,fiberglass reinforced,with a polyester fabric surface 4.7 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet FRSA/TR109-18 4.8 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet )FR) FRSAfrR109-18 4.9 PolyflexG ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for FRSA/1RI 09-18 use as an alternate to Heat Applied"Cap Sheet"in the 'Two Ply System"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition beneath mechanically fastened or adhered tile roof systems 4.10 Polynex G FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for FRSA(TRI 09-18 use as an alternate to Heat Applied"Cap Sheet"in the "Two Ply System"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition beneath mechanically fastened tile roof systems 4.11 Polyflex SA P ASTM D6222 FL,T% Polyester-reinforced,APP modified bitumen cap sheet FRSA/TRI 09-18 4.12 Polyfiex SA P FR ASTM D6222 FL,T% Polyester-reinforced,APP modified bitumen cap sheet FRSA/TR109-18 4.13 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet 4.14 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced,asphaltic base sheet NEW ETC,LLG eaaluxi Report P12060.02.09-R3] Cerefimte pjAN6orRatlpn Y330.53 7-EDITION 12020)FBCN0N4nIHZ EVALUATION FUUS9-R31 Polygla s Roof UndedaYMelna Reaislon 27:09/30/2020 Page 3 of 17 ®NEMO l etc. 4. PRODUCT DESCRIPTION: Product Material Standard Plants) Description 4.15 Polystick lR-Xe ASTM D1970 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an aggregate surface 16 Polystick MTS Plus ASTM D1970 F4 NV, Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 PA,TX membrane,glass fiber reinforced,surfaced with polyolefinic film surface 4.17 Polystick MU-X ASTM D197W FL,KV,PA Nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane,fiberglass reinforced,with a polypropylene film surface 4.18 PDlystickTU Max ASTM D1970 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane with a 190 g/m2 polyester fabric surface 4.19 Polystici Is FRSA/TR109-18 FL,PA,TX Nominal 130-mil thick rubberized asphalt waterproofing membrane,glass-fiber/polyester reinforced,with a granularsurface 4.20 Polystick TU Plus ASTM D1970 FL,PA,TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TR109-18 membrane,glass fiber reinforced,with a polyester fabric surface 4.21 Polystick XFR ASTM D1970 NV,TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane,glass fiber reinforced,surfaced with textured film surface e 5.1 This is a Building Code Evaluation. Neither MEMO ETC,LLC nor Robert Niemmen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assemblyfre classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 1 PolyezLk Nil ha,beenjound through comparative testing to haveole I,,oefdentotlnttlon than ASTM D226mffngjekin o drvmnditw,testedotkoDdard kbomtoywndrtiom. Agmmentbetw pumhweraodselleo m mtjonh in5ecdon 4.3,Nate I ojASrM DM 15,shoukbe estoblishedos to slip resistanw. NEMO ETC,U.C. Evaluation Report P12O6O.OL09-R27 QrtpkarefAUMwhpaan rr3l,55 7'"EDITION(2020)FBC NON-HVHZ EVALUATION F1.5259-R31 Polyglass Roof Undedaymems ReWsion27:09/30/2020 Page 4 of 17 NNEMO I etc. 5.6 Allowable Roof Covers: TABLE I: ROOF COVER OPTIONS a1spNNs Oar,and Eencreta Me mebal slap or wood U.dedsyment shingles 0502.N Slate-Type 113,17N Mechanical Adhe die, Pa. shingles shirla shingles shadem,1m2�1 ALtacM1 set psdxN psaxel psm.21 (ssm.N Yes Yes Yes Yes Yes Yes Yes Yes Elastobase (nen.n p.emesne.a, Wa+..shery Paa,mn ,.n linemen. W. . N . ..m 0x mows, non ryuN s..san see s..3) mM,Tenell) ...'W") mu,Tralll M.nl Tranu Yes Yes Yes Yes Yes Yes Yes Yes ElastobaseP Nvn,n.n (asannsh.et lafon es, Youn"oen lee.. Vhnua.n own..., ywem wss o3 , e2KA 11) seesee s e m ) ou6,araa oau,Npen) oau,rayel0 Twn) t,,ni Yes Yes Polyglass Base No la.e..estx4 la Nsen.rL No No No No No Ss5.a.31 Sees.) Yes Yes Poh/glase 62 Base No heeansh..t ba.m5hee, No No No No No 3ees831 Sns.l31 Elastoflex SSG No Yes Yes(sees e.11 No No No No No Elastoflex 56 G FR No Yes No No No No No No Yes Yes HydraGuard Dual Pro Yes No No Yes Yes Yes p,Mam'w Lws.11s p.l.aa .une,133 /asps I /mos.L3.m K Yes Hyd2Guafd The Pro YesYes es Y (5ee561) Yes Yes Yes Winnalleo1.13a pamnnps,irm.113 /a9o5.3.131 /lpW Ll3) Mule-Hide SA-APP Cap Sheet N0 YK IsaYes.11 No No No No No Mule-Hide$A-APP Cap Sheet(FR) No Ya lsce ss6N No He No No No PolyflexG No Yes fsa 5s.& 1 Ns No No No No Polyflex G FR No Yes No No No No No No Polyflex SA P No Yes ($eYess l) No No No No No Polyflex SA P FR No Yes Isee s No No No No No Yes Yes Poh/Stick lR-%e Yes No No No No Yes lenu n,tsm.133 V.M an.eve.113 /p9o5.11.31 /0.Wi.1.13) Yes YK Polystick MTS Plus Yes Yes, No Ya Yes Yes e.lmnM1u,3sw.113 pdmleas,Lmn.113 "one 1.331 /asn".1331 Ye Yes Polystick MU-l( Yes No No Yes Ya Yes VgmynP,13m.1.13 Vmmnnw.lser /am9.Lv31 /Mos.i.}.31 V. Yea Polystick TU Max No Yes Yes Y. Yes No pm.0mismLva pumnny,um.e.Ls IXe$.6.1i /a9W.3.331 /asG5.113) Y. Yes Yes Polystiek TUP No Yes (See$.&I) No No No ont, c..La winafmp,3sm,1. /Aaas.v331 /lmfa.}31 PalysNck TU Plus Yez Ves Yes yes Yes Yes p YK Ya (son 5.6.1) net Snp,l50a.1.13 peM sblpt 35mil) /pS0.11.31 /PSOi11.3) Yes K POlystlek XFR Yes Yes No Yes Yes Yes Vamnnvr3sn.Lu pd.amps,1413.113 /fl3G3.L131 /a9oS.1L3 NEMO ETC LLC. Evaluation RePort P12060,02.09-R27 CeNficote ofAW6miMim R3165$ TTM EWION 1202%M NON-HVNZ EVALUATION F15259-R31 polyglese Rod Underlaymems Revision 27:09/3012020 Page 5 or 17 ONEMOletc. 5.6.1 Adhesive-set tile is limited to use of the following underlayment/tile-adhesive combinations. TABLE 3A:ALLOWABLE UNDERUPYMENT/TILE-ADHESIVE COMBINATION52 Underlayment Adhesive Florida Product Approval Polystick TU Max Ur Poly Ock TU Plus DAP Foam'Touch'n Seal FL14506 Stormisond Roof Tile Adhesive" HydrsGuard Tile Pro,Polyflex SA P,Polystick TT/Max,Polystick TU P or Polystick Dupont-rile Bond'"Roof Tile FL22525 TU Plus Adhesive" Elastoflex S6 G,HydraGumd Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA- ICP Adhesives and Sealants APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,Polystick TU Max, "Pollate AH-360" FL6332 Polystick TU P or Polystick TU Plus Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP Up Sheet,Mule-Hide SA- ICP Adhesives and Sealants APP Cap Sheet(FR),Polyflax G,Polyflex SA P,Polyflex SA P FR,Polystick TU Max, I_CP Adh IvesRTA an FL6276 Polystick TU P or Polystick TU Plus Poly. 5.7 Allowable Substrates: TABLE 2:SUBST 71!OPTiONS FOR ADHERED UNDERPAYMENTS Underlayment Appfiratlon Substates(designed to meet wind loads for project) Type primer Materlal(sl HydraGuard Dual Pro, (Optional)ASTM plywood,OSe,Southern Yellow Pine or Huber Engineered HydraGuard Tile Pro,Polystick lR- Deck/ D41 Woods"ZIP System"Panels Xe,Polystick NITS Plus,Polystick sheathing ASTM D41 stactual roncrete MU-X,Polystick TU Max, self- ASTM C1289 Type II Class 1 polyisocyanurate,ASTM Palystick TU P,PoWick TU Plus, adhering Insulation (Optional)ASTM C1289 Type V polyisooyanurate-composite,DensDeck Polystick XFR,Mule-Hide SA-APP D41 or WB-3000 Prime or SECUROCK Gypsum-Fiber Roof Board Cap Sheet,Mule-Hide SA-APP Up Sheet(FR),Polyflex SA P or Base Sheet N/A ASTM D226,Type II felt Elastobase,Elastobase P or Mule- Polyflex SA P FR I Hide Nail Base Deck ASTM D41 structural concrete Elastoflex S6 G or Elastoflex S5G Insulation (Optional)MTM DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FR hot asphalt D41 Base Sheet N/A ASTM D226,Type II felt Elastobase,Elastobase P,Mule- Hide Nail Base or Polyglass G2 Base Deck ASTM D41 structural concrete torch- Insulation (Optional)AS1W DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board EP.Iyfl..CorP.lyAfle.1 FR applied D41 Base Sheet N/A Elastobase,Elastobase P,Mule-Hide Nan Base,Polyglass 62 Base or Polyglass Base 7 Refer to Tile Manufactures or Adhesive Manufacturer's Florida Product Approval far Overtumin9 Moment Resistance Performance. NEMO Etc,LLC. Evaluation Report PU050.02.09-1127 Cer*.WP7Authara ng32455 PEDITION(2020)FBC NON-HVHZ EVALUATION FI5259-R31 Polyglass Roof underiaymems Revision 27:09/W/2020 Page 6 of 17 NNEMO I etc. 5.8 Attachment Limitat'ons: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with the manufacturers installation instructions, but—for mechanically attached underlayments or base sheets-not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems,attachment shall be in accordance with the manufacturer's installation instructions,but— for mechanically attached base sheets-not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1(for Two- Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein ifor other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5,8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure--52.5 psf: Deck: APA rated,7116 CAT,D418 in.,Exposure 1,050 sheathingto meet project requirements to satisfaction of Authority Having Jurisdiction. Joints: Min.4-inch wide strips of Elastoflex SA-V over all OSB joints Base Ply: Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TO Plus,sect-adhered. #2 Maximum Design Pressure--90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TO Max,Polystick TU P or Polystick TO Plus,self-adhered. #3 Maximum Design Pressure=-97.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PGI00 or ASTM D41 Base Pry: (Optional)Polystick MTS Plus,self-adhered. Underlayment Mule-Hide SA-PPP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TO P or Polystick TO Plus,self-adhered and hack-nailed within the seMedgeedge side laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin ups spaced 12-Inch o.c. #4 Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction. Primer: WB-3000 Base Ply: (Opeonall Polystidt MTS Phis,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),POlVne%SA P,Polyflex SA P FR,Polystick TO Max,Polystick TU P or Polystick TO Plus,self-adhered and back-nailed within the selvedge-edge side laps using 12 Be.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin raps spaced 12-inch o.c. REMO ETC,U.C. Evaluation Report P32060.02.09-M7 &mJlrorelAUMmcmian Ys1055 7r"EDmON(2020)FBC NON-HVH2 EVALUATION FL5259.01 Pelyglass Roof Underlayments Revision 27:09/3012020 Page 7 of 27 ONEMO I etc. #5 Maximum Design Pressure=-135 asf: Deck: Min.15/32-Inch plywood to..at project requirements to satisfaction of Authority Having Jurisdiction. Primer. (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS Plus,self-adhered, Joints: Min.flinch wide strips of Elision"SA-V over all plywood joints. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self adhered. #6 Maximum Design Pressure=-315 psf: Deck'. Structural concrete to meet prefect requirements to satisfaction of Authority Having Jurisdiction, Primer: PGIOO or ASTM D41 Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet(FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #7 Maximum Design Pressure--6225 Off: Deck: Structural Concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PGIOO or ASTM D41 Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #8 All other di rest-deck,adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of-45 psf. 5.8.3.2 Mechanically-Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSAJTRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A, Table iA or the critical (highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDi, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RA5137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for enhancements. #9 Maximum Design Pressure=-300 psf": Deck: Min.15/32-inch OSS to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: &inch D.C.at the 3-inch wide side laps and 6-Inch D.C.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MIS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyfex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-atlhered. #10 Maximum Design Pressure:-37.5 PsP-: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. aria Sheet Elastobase or Mule-Hide Nail Base 1poW-film top surface) Fasteners: it ga.x1.25-Inch long 1-inch head diameter round metal cap nails Spacing: &inch D.C.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MIS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #11 Maximum Design Pressure=-37.5 psf- Deck: Min.19/32-inch plywood to meet project requirements to satBfaction of Authority Having Jurisdiction, Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 14nch head diameter round metal cap nails Spacing: &inch D.C.at the 3-Inch wide side laps and 124nch o.c.at two(2)equaDV spaced staggered center rows. Underlayment Elasto6ex S6 G,applied In full mopping of hot asphalt. NEMO ETC,EEC. Evaluation Report P32M.02.09-1127 CrnDfimrr0fAKlwuaV6a#32i55 7'a EDDION(2020)FBC NON-HVHI EVAIUATON fi-5259-"I PolygWs Roof Uraledaymems Revision 27:09/30/2020 Page 8 of 17 ONEMOjeft. #12 Maximum Desien Pressure=-45 sfe: Deck: Min.19132-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 Be.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin Caps Spacing: 4-inch D.C.at the 2-inch wide side laps and 4-Inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with se#-adhering underlayment only)Polystick MTS Plus,self-adhered. Underlayment Mule HideSA-APP Cap Sheet,Mue-Hide SA-APP Cap Sheet(FR),POVyfiex SA P,Palyfiex SA P Fit,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #13 Maximum Design Pressure=-45 Psf Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two(2)layers ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps Spacing: 9-inch D.C.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick NITS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P Fit,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered or Elastoflex$6 G,applied in full mopping of hot asphalt. #14 Maximum Design Pressure=-45 psf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface far hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch D.C.at the 2-inch wide side laps and 18-inch D.C.at two(2)equally spaced staggered center rows. Underlayment Elastofiex S6 G,applied in full mopping of hat asphalt or Polyflex G,torch-applied. #15 Maximum Design Pressure=-45.0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nall Base(poty-film top surface) Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin Caps Spacing: 6-inch D.C.at the 3-inch wide side laps and 6-inch D.C.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick NITS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(Fit),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #16 Maximum Design Pressure=-45.0 psf: Deck: APA rated,7/16 CAT,0.418 In.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having 3unstiction. Base Sheet: Elastobase(sand top surface) Fasteners: 12 ga.annular ring shank nails With 1-5/8"diameter tin caps Spacing: 6-inch o.c.at the 3-Inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment Elastaflex S6 G,applied in full mopping of hot asphalt. #17 Maximum Design Pressu re=-050 issf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction Of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: 12 ga.annular ring shank nails with 1-518"diameter tin caps Spacing: 6-inch D.C.at the 3-Inch Wide side laps and flinch D.C.at four(4)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied. #18 Maximum Design Pressure=-52.5 AM Deck: Min.15/32-inch plywood to meet project requirements to satisfaCtion of Authority Having Jurisdiction. Base Sheet: Elastabese(sanded top surface for hot-asphaft or torch-applied Cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-Inch o.c.at the 2-inch wide side laps and 12-inch ox.at two(2)equally spaced staggered center rows. Underlayment Dastaflex S6 G,applied in full mopping of hot asphalt or polyflex G,torch-.,pled. MEMO ETC,LLC. Evaluation Report P32060.02.09-R27 CerOAvte^fAW,orgadon 1132a55 7` EEmaaN 12MD)FHC NON-HV112 EVALUATION FL5259-R31 POIyglass Roof UndeHaymems Revision 27:09/30/20ZO Page 9 of 17 NNEMOjetc. #19 Maximum Design Pressure=-525 rxsf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or MUle-Hide Nail Base(poly-Rim top surface) Fastener: Simplex Original Cap Nails Spacing: 6-Inch D.C.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlaymem.Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyhex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #20 Maximum Design pressure=-525 Rsf'. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment Elastoflex S6 G,applied in full mapping of hot asphalt of Potyflex G,torch applied. #21 Maximum Design Pressure=-60 pill: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied rap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Soadog'. &inch o.c.at the 4-mch wide side laps and 8-inch o.c.at three13)equally spaced staggered center rows. Underlayment: Elastoflex 56 G,applied in full mopping of hat asphalt or Polyflex G,torch-applied. 422 Maximum Design Pressure=-60 psif: Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied up) Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.at the flinch wide side laps and 12-inch D.C.at two(2)equally spaced staggered center rows. Underloyment:Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #23 Maximum Design Pressure=-600 Psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,05B sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex MW Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Primer: PG300 or ASTM D41 primer applied to stress plates. Base My: (Optional)Polystick MTS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FRI,Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #24 Maximum Design Pressure=-60.0 pill: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,0513 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MA)IXCop Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced Staggered center rows. Underlayment:Elastoflex S6 G,applied in full mapping of hot asphalt. #25 Maximum Design Pressure=-60.0 osf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Poiyglass Base Fasteners: Simplex lvl ( Cap Fasteners Spacing: 8-inch o.t.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Polyflex G,torch-applied. NEMO ETC U.C. Evaluation Report P32060.02.09-R27 CertlhMeolqufhroxl.o#3}O55 ]`"EDITION(2020)F3C NON-HVHZ EVALUATION FI5259`1131 Polyglass Roof Underlaymems Revision 27:09/30/20M Page 10 of 17 MEMO J etc. #26 Maximum Design Pressure--6Z 5 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of wmhappJied undedoyment) Fasteners: 12 ga.x 1.25-inch long 3/8-inch head dlarneter annular ring shank roofing nails at 1-SI&inch diameter tin caps Spacing: 8-Imh D.C.at the 4-Inch wide side laps and 8-inch D.C.at four(4)equally spaced staggered center rows. Underlayment Elastoflex S6 G,applied In full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #27 Maximum Design Pressure--67 5 Dsf: Deck: APA rated, 19/32 CAT,0.578 in., Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having lurisdlctlon. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFA5T Versa-Fast Fasteners&Plates with two(2)screws per plate installed JSO-into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch D.C.at the 4-inch wide side laps and 12-Inch D.C.at two(2)equally spaced staggered center rows. Primer: (Optionall PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #28 Maximum Design Pressure--675 Dsf: Deck: APA rated, 19/32 CAT,0.578 In., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 190'into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch o.,at the 41dch wide side laps and 12inch D.D.a1 two(2)equally spaced staggered center rows. Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt. #29 Maximum Design Pressure--67.5 Dsf: Deck: APA rated, 19/32 CAT,0.578 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Poyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 380°into the holes of the plate,parallel to the width direction of the sheet. Spacing: 12-inch D.C.at the&Inch wide side laps and 12-inch D.C.at two(2)equally spaced staggered center rows. Underlayment Poyfex G,torch-applied. #30 Maximum Design Pressure=-75 Dsf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Saw(requires use oftwch-Opplied underlaymentj Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates(AccuTrac),Trufast HO with Trufast 3-Inch Insulation Plates or Simplex MAxx Cap Fasteners Spacing'. 10-inch D.C.at the 44nch wide side laps and 10-inch D.C.at three(3)equally spaced staggered Center rows. Underlayment: Elastoflex 56 G,applied in full mapping of hot asphalt or torch-applied or Polyflex G,torch-applied. #31 Maximum Design Pressure--90 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAxX Cap Fasteners Spacing: 6-inch D.C.at the 2-inch wide side laps and 6-inch D.C.at two(2)equally spaced staggered center rows. Underayment:Eastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #32 Maximum Design Pressure=-90Dsf: Deck: Min.35/32-inch plywood to meet project requirements m satisfaction DE Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-fllm surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch D.C.at the 4-Inch Vida side laps and 6-inch o.c.at three(3)equally spaced Staggered center rows. Underlayment Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. MEMO im;U.C. Evaluation Report P120150.02.09-R27 Cemikofe fAudnrhmbn#32455 rEDMON(1t20)RIC NON-HVHZ EVALUATION FL5259-R31 Palyglass Roof undedayments Revision Z7:09/30/Z020 Page 11 of 17 ONErviojetc. #33 Maximum Design Pressure=-90 p5f: Deck: min.15)32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: &inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment Elastoflex 56 G,applied in full mopping of hot asphalt. #34 Maximum Design Pressure--90 psf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-oppjied undedoymerd) Fasteners: Dekfast914 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-Inch o.c.at four(4)equally spaced staggered center rows. Underlayment Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. #35 Maximum Design Pressure=-90.0 Pat Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet Project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'Into the holes of the plate,parallel to thewidth-direction of the sheet Sparing: 9-Inch O.C.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Primer: PG1D0 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick NITS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(Fit),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P at Polystick TU Plus,self-adhered. #36 Maximum Design Pressure=-900 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathingto meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners. TRUFAST Versa-Fast Fasteners&Plates with two 12)screws per plate Installed 18W into the holes of the plate,parallel to the width-direction of the sheet Spacing: &inch o.c.at the 2-inch wide side laps and 12-inch o.c at two(2)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt. #37 Maximum Design Pressure -90.012 : Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elasobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)grews per plate installed 180-Into the holes of the plate,parallel to the width-direction of the sheet Spacing'. Smirch at.atthe 2-inch wide side Paps and 124nch D.C.at two(2)equally spaced staggered center rows. Underlayment Polyflex G,torch-applied. #38 Maximum Design Pressure=-97,5 Bad: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Shell: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x1.25-inchx3/8-inch head diameter annular ring shank mofng nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 4-inch wide side laps and flinch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick NITS Plus,self-adhered. Underlayment Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(Fit),Polyflex SA P,Polyflex SA P Fit,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. NEMD ETc.tic. Evaluation Report P12060.02.09-R27 ocoftreufAPthPrlrugong37455 7-EDMON 12020)FBC NON-HVHI EVALUATION R52$9.R31 Polyglas Roof Undedsymema Red:Ion 27:09/30/2020 Page 12 of 17 NNEMOJeM #39 Maximum Design Pressure--975 psf: Deck: APA rated, 19/32 CAT,0.578 in., Exposure 1,058 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: Simplex MAxXCap Fasteners Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-Inch o.c.at four(4)equally spaced staggered center rows. Primer: PG1sxl or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FRI,Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #40 Maximum Design Pressu re--97.S psf: Deck: APA rated, 19/32 CAT,0.578 In., Exposure 1, 058 sheathing to meet project:requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: Simplex MAID(Cap Fasteners Spacing: 6-inch o.c.at the 4-mch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Untlerlayment:Elastoflex S6 G,applied in full mopping of hot asphah. #41 Maximum Design Pressure=-97.5 psf: Deck: APA rated,19132 CAT,0.578 In.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: Simplex MAxx Cap Fasteners Spacing: 6-inch o.c.at the 4 Mch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlaymem,Polynex G,tor<n-applietl. #42 Maximum Design Pressure=-105 psf: Deck: Min.15/32-inch plywood to meet project requirements tD satisfaction of Authority Having lurisdicmm. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAxx Cap Fasteners Sparing 62mch o.c.at thet-inch wide title laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Untlerlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #43 Maximum Design Pressure=-105 0 psf: Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)"news Per plate installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-Inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polyriick MIS Plus,self-adhered. Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FRI,Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #44 Maximum Design Pressure--105.0 psf: Deck: APA rated,7/16 CAT,0418 in.,Exposure l,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sand top surface) Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(21 screws per plate installed 180°into the holes of the plate,parallel to the width-direction of the sheet Spacing: 6-inch o.c,at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. UnderlaymenC Elastoflex 56 G,applied In fuR mopping of hot asphalt. NEMO ETC,LUC. Evaluation Report P32050.02.09-R37 Certffkvrc ojAu[Iwtlzmion Y32055 EDITION(2020)FBC NON-HVH2 EVALUATION FL5259-R31 Polyglass Roof Underlayments Revision 27:09/30/2020 Page 13 of 17 ONEMOjetc. #45 Maximum Design Pressure=-105 0 psf: Deck: APA rated,7116 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two screws per plate Installed 180'into the holes of the plate,parallel to the width-direction of the sheet Spacing: &inch o.c.at the 44tsch wide side laps and&inch o.c.at three(3)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. #46 Maximum Design Pressure z 412.5 vsf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x1.25-Inchx3/BAnch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: &-inch o.c.at the flinch wide side laps and&inch o.c.at four(4)equally spaced staggered center rows. Primer: PGI00 or ASTM D41 primer at all tin-caps Base Ply: Polystick NITS Plus,self-adhered Undedayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick TU P or PolystickTU Plus,seN-adhered. #47 Maximum Design Pressure=-120 psf: Deck: Min-IS/32-inch Plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and&inch a.c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #49 Maximum Design Pressure=-120 ps4 Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufist#14 HD with Trvfast3"Metal Insulation Plates Spacing: 6-inch o.c.at the flinch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment.Elastoflex%G,applied in full mopping of ha asphah. #49 Maximum Design Pressure=-127.5 psf: Deck: APA rated,19132 CAT,0578 in.,Exposure 1,O58 sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film tap surface) Fasteners: TRUFAST Versa-Fast Fasteners B,Plates With one(1)screw per plate,in the center hole. Spacing: 9-inch o.c.at the flinch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer applied to stress plates. Base Ply: (Optional)Polystick MTS Plus,self-adhered. Underlayment Mule—Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Po"ex SA P,POlyflex SA P FR,Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered. #50 Maximum Design Pressure=-127.5 psf: Deck: APA rated, 19132 CAT,0.578 in., Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having)urisi icilon. Base Sheet: Elastoluse(sand top surface) Fasteners: TRUFAST Versa-Fart Fasteners&Plates With one(i)screw per plate,In the center hole. Spacing: 9-inch o.c.at the flinch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment Elastoflex S6 G,applied in full mopping of hot asphalt. #51 Maximum Design Pressure=-127.5 psf: Deck: APA rated, 19/32 CAT,0.578 in., Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Polyglass Base Fasteners: TRUFAST Versa-Fast Fasteners&Plates with no(1)screw Per plate,in the center hole. Spacing: 9-Inch o.c.at the flinch wide side laps and 9-Inch o.c.at four(4)equally spaced staggered center rows. Underlayment: Polyflex G,torch-applied. NEMD ETC.D.C. Evaluation Report F12060.02.09-R27 4em#mte uJAW,PnrPlion N32454 7-EDI1IDN l2p21k)F%NON-HyN2 EVALUATION 1:35259-1131 Polyglass Roof UndeHaymeMs Revision 27:09/30/2020 Page 14 of 17 ON EMO I etc, 5.9 Exposure Limitations: TARE 3: EXPOSURE LIMITATIONS Underaymem Prepared Roof Covar Maximum Installation Type Exposure(days) Elastobase,Elastobase P,Polyglass G2 Base or Polyglass Base Mechanically attached 30 Polystick lR-Xe or Polystick MU-X Mechaniallyattached 90 HydaGuard Dual Pro,HydraGuard Tile Pro,Polvalck MTS Plus,Po*tldk113 Max,Potystck Any type(per Table l) ISO TU P,Polystick TU Plus or Polystick XFR - Elastofex 56 G,Elastoflex S6 G F%Mulrliide SA-APP Cap Sheet,Mule-Hide SA-APP Up Adhesw"et the roof system ISO Sheet(FR),Polyflex G,PolyflexG FR,Polyflex SA P or Polyflex SA P FR Mechanically attached UNUMITED 5.10 Tile Slippage Limitatlons�When loading roof tiles on the underlayment in direct-deck the roof assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TAStE4:TIE SLIPPAGE LIMITATIONS FOR DIRER-D=THE INnaut om Underlayment Tile profile Staging Method Maximum Staging Slope Elastoflex 56 G or 56 G FR Flat or Lugged 6-tile stack(4 over 2) Prohibited without battens HydaGuard Tile Pro Flat or Lugged Fdle sack(4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 aver 2) 4:12 Flat 6-tile sack(4 over 2) 5:12 Polystick MTS PIuz Lugged 6-tile stack(4 over 2) 4:12 Flat G-tile stack(4 over 2)or Ibtile sack 7.12 Polystick TU Max Lugged 6-file stack(4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TUP Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat or Lugged 6tile sack(4 over 2) 7:12 Polystick TU Plus Flat or Lugged 10-tile sack 6:12 Polyrtick XFR Flat or Lugged Prohibited without battens Prohibited without battens NEMO ETC,I.I.C. EValoa[ion Report P1ZOW.OZ.09-R27 Le,Bfimre MAvrlwrizorion A32A55 7-EDITION(2020)FBC NON-HVHZ EVALUATION 11.5259-R31 Polyglass Roof Underlayments Revision 27:09/30/20M Page 15 of 17 IIJV NEMOI etc. 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published Installation Instructions subjectto the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.3 Elastobase,Elastobase P or Mule-Hkle Nail Base: 6.3.1 Non-Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM D226,Type 11)in FBC Table 1507.1.2.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed,and the manufacturers installation instructions. FBC requirements take precedence over the manufacturers installation instructions. Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick NITS Plus,Polystick MU-X,PolystickTU Max,Polystick TU P,PolystickTU Plus,Polystick XFR,POW"SAP,Polyflex SA P FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),self-adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those arethose associated with the topdayer underlaymeM,asset forth in Table 1. 6.3.2 Tile Applications: 6.3.2.1 Elastobase(poly-film top),Elastobase P(poly-film top)and Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the"TWO-PLY SYSTEM"from FRSA/TRI Florida High Wind Concrete and Gay Roof Tile Installation Manual,Sixth Edition,followed by Polystick NITS Plus,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick XFR,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),self-adhered or Polyflex G or Polyflex G FR,torch-applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for attachment requirements. 6.3.2.2 Elastobase(sanded-top)and Elastobase P(sanded-top)e are limited to use as a mechanically attached base sheet in the"TWO- PLY SYSTEM"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,followed by Elastoflex S6 G,Elastoflex S6 G FR or an FBC Approved Mineral Surfaced Cap Sheet(ASTM 1363801,asphalt-applied or polyflex G or Polyflex G FR,torch-applied. Tile roof Installation method is limited by the selected Cap Sheet,as set forth in Table 1. • When Elastobase(sanded-top)or Elastobase P(sanded-top)is followed by asphalt-applied Elastoflex S6 G,Elastoflex S6 G FR or FBC Approved Mineral Surfaced Cap Sheet(ASTM D6380),refer to FRSA/TRI,Sixth Edition,Appendix A,Table 1 or Section 5.8.3.2 herein for attachment requirements. • When E lastobase(sa nded-top)or Elastobase P Ise nded-top)is followed by torch-applied Polyflex G or Polyflex G FR,refer to Section 5.8.3.2 herein for attachment requirements. 6.4 HydraGuard Dual Pro,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P, Polyflex SA P FR,Polystick IR-Xe,Polystick MIS Plus,Polystick MU-X,Polystick TU Max,Polystick TU P,Polystick TU Plus or Polystick XFR: 6.4.1 General: All seal-lap seams(selvage laps)must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard'rite Pro, align the edge of the top sheet to the end of the glue pattern(the sheet will overlap the fabric}. View of Ovelap Seam a HydraGuard Dual No and HydraGuard Tile No NEMO ETC,LLG Evaluation Repoli 1,12061IA2.09-R17 CertRkate oJAmtwrizmimr310.55 I-EDITION 12020)ESE NON-4VH2 EVALUATION FLS259-fUll Polyglass Roof Underlayments Revision 27:09/30/2020 Page 16 of 17 ONEIVIOjetc. 6.4.2 Non-Tile Applications: Shall be installed In compliance with requirements for an approved self-adhering underlayment (ASTM D3970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation Instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt,Elastobase,Elastobase P or Mule-Hide Nail Rase,the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.4.3 Tile Applications(excludesHydraGuard Dual Pro,Polystick lR-Xe and Polystick MU-X): Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition and the manufacturers installation instructions. Refer t0 Section 53.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.4.4 Multi-Ply Underlayment Systems: Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro,PolyflexSA P,Polystick MTS Plus,Polystick MU-X,Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement but is allowable if a 2-ply underlayment system is desired. Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under adhesive-set tile systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply undedayment system is desired. 6.5 ElistWlmt S6 G of Ehistoflex56G FR: 6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet' in the 'Two Ply System" in the FRSA(TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, and the manufacturers installation instructions. Refer to Section 5.8.2 and S2.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.6 Polyflex G or Polyflex G FR: 6.6.1 Shall be installed in compliance with requirements as an alternate to the-Heat Applied Cap Sheet"in the"Two Ply System-in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. a. MANUFACTURING PLANTS: Contact the named QAentityfor manufacturing facilities covered by F.A.C.Rule 63G20-3 CIA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY UL LLC—QUA9625;(414)248-6409;Karen.buchmannaa7ul.com -END OF EVALUATION REPORT- NEMo ETC,I.I.C. evaluation Report P0ZND.R.09-R27 tem0mteefAvfla tianr34155 7-EDITION pRoo)FIfc NON.HVHZ EVAWATION 1`15159-R31 Pnlyglass Roof Underlaymer4s Revision 27:09/30/2020 Page 17 of 17