Loading...
HomeMy WebLinkAbout217119-1d Compaction signedHeadquarters 1W C IL � ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 1 %% AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: September 7, 2021 KSM JOB #: 217119-1d/MM/jam NUC # 4590 PERMIT #: 2106-0271 Nuc Model: Troxler 4590 Nuc Serial #: 79187 CONTRACTOR: James Trefelner Moisture Probe Model #: 6760 JOB LOCATION: 10610 Pine Needle Drive Moisture Probe Serial #: 079097 Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 S.W. 0" - 12" 15+ D 116.2 118.8 97.8% 2 N.W. 11 11117.9 1199.2% 3 Center 11 11118.5 1199.7% 4 N.E. I I 11118.2 1199.5% 5 S.E. I I 11117.7 1199.1% Soil Description: Brown Sand with Clay In Place Moisture: 9.1% Proctor Optimum Moisture: 12.0 % Proctor Max. Dry Density: P.C.F. 118.8 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: Digitally signed by Thls item has been electronically signed and Julie Keller aled by Julie Keller, P.E. FI. Lic. 68366 on the date stated directly to the right using a Date: digitature. Printe,dd,copies of this tlocument are not nsidered slgned and sealed and the signas. ture mus[be verified on anyeleRronic 2021.09.08 rople 11:15:17 -04'00' Julie E. Keller, P.E. President 120.0 W I I I I I I I E119.0 L..�.._.._..�.._,._..�..�.._.._.._ � H 118.0 T I I I I I 117.0 t—•.J.._.I_..1.. I._..L..J.. I_.._ P I I I I I I C 116.0 -4 .1 — _I._..l..--4.._.I_.._ I I I I I I I I F 115.0 �.._ :_..t.._I._..r..y.._.I_.._ I I I I I I 114.0 —1.._.i_..T.._1' .—1.._.i_.._ D I I I I I I I F: 113.0..�.._.i_..t.._�._..r..�.._.i_..� Y 7 8 9 10 11 12 13 14 15 Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. PE# 68366 9/8/2021 Email to: planreview@stlucieco.org• permits@stlucieco.org Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE