Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
REVISED A2
LIVINGGARAGELANAIENTRY&PORCHTOTALLIVING C.F. = +/- 16,8301,9566793021663,103SQUARE FOOTAGEA/C on standRANGE W/HOOD51'-10"25'-4"16'-6"9'-8"3'-2"12'-6"1'-4"75'-0"51'-10"75'-0"15'-0"20'-0"31'-4"5'-4"28'-8"6'-8"16'-6"19'-4"6'-8"4'-6"6'-8"4'-6"9'-0"3'-2"15'-4" 7'-8"3'-2"4'-2"1'-4"18'-8"12'-0"2'-8"16'-8"8"14'-0"5'-0"5'-8"8"6'-8"3'-8"10'-0"8"10'-11"2'-5"11'-0"10'-81 2"7'-4" 8'-0"8"21'-81 2"5'-8"12'-8"6'-0"8"8"10'-2"2'-0"16'-2"8"11'-6"8"8"15'-0"8"3'-8"10'-8"8"8"4"3'-4"4"8"16'-6"8"6'-0"4'-111 2" 8"6'-6"9'-6"14'-0"8" 3'-0"4"2'-3"3'-3"8"12'-714"18'-434"7'-1114"4'-0"8"4' - 6 "10"3'-0"8"10'-10"4'-4"10'-4"8"SIMPSON HTS20CONNECTED TOEACH TRUSS ALONGFRAMED BEARINGWALLS U.N.OSIMPSON HTS20CONNECTED TOEACH TRUSS ALONGFRAMED BEARINGWALLS U.N.O30"X30"ATTIC ACCESSFIELD LOCATE30"X30"ATTIC ACCESSFIELD LOCATE4'-0"1'-4"1'-4"4'-0"1'-4"15'-2"1'-4"4'-0"3'-4"8'-0"1'-4"11'-4"7'-4"23'-4"43'-4"28'-8"8"10'-2"8"4'-212"5'-034"4'-512"7'-6"8"8"7'-4"22'-0"8" 4'-8"4'-0" 11'-71 2"16'-8" 1'-31 2" 8'-31 2"9'-1112"4'-5"8"2'-8"7'-4"4068 BF 24'-71 2" 32"x 8" FGTEMP/OBCS SH 35 EGRESSSH 35 SH 25 EGRESS SH 25 EGRESSSH 25 EGRESS S H 3 5 SCREEN ENCLOSUREWITH CONTINUOUSLOWER KICKPLATESPRAY APPLIED R-20EXPANDED POLYSTYRENEINSULATION FOAMENTIRE HOUSEINCLUDING OVER GARAGESYMBOLREPRESENTSWALL TYPE LEGENDCMU WALL - 8" (U.N.O.) BRG. HT. @ 10'-9" AFFINTERIOR SIDE - 1/2" GYP. BRD. OVER 1x P.T. FURRINGINTERIOR SIDE @ GARAGE - SMOOTH FINISH - PAINTEDWITH NON GROUTED CELLS FILLED WITHEXPANDED POLYSTYRENE FOAM INSULATIONEXTERIOR SIDE AND COLUMNS - STUCCO CMU WALL - 8" (U.N.O.) BRG. HT. PER ELEVATIONSINTERIOR SIDE - SMOOTH FINISH - PAINTEDEXTERIOR SIDE - STUCCOCMU WALL - 8" (U.N.O.) BRG. HT. PER ELEVATIONSINTERIOR SIDE - 1/2" GYP. BRD. OVER 1x P.T. FURRINGEXTERIOR SIDE - STUCCO WITH NON GROUTED CELLS FILLED WITHEXPANDED POLYSTYRENE FOAM INSULATIONBRG. PARTITION WALL - INTERIOR - 4" (U.N.O.)1/2" GYP. BD. ON EACH SIDE OF 2x4 WD. STUDS @ 16" O.C.w/ CONT. 2x4 SILL AND DBL. 2x4 TOP PLATESBRG. PARTITION - GARAGE WALL - 4" (U.N.O.)1/2" GYP. BRD. BOTH SIDES OF 2x4 WD. STUDS @ 16" O.C. w/ CONT. 2x4 SILL AND DBL. 2x4 TOP PLATES w/ R-11 BATT INSULATIONNON BEARING PARTITION - INTERIOR - 4" (U.N.O.)3 5/8" MTL STUDS WITH UPPER AND LOWER RUNNERSAT 24" O.C. MAX.w/ WOOD BLOCKING AT OPENINGS AND WHERE REQUIREDCMU WALL - 8" (U.N.O.) BRG. HT. PER ELEVATIONSINTERIOR SIDE - SMOOTH FINIH - PAINTEDEXTERIOR SIDE - HARDIE PLANK SIDING1'-0"1/2" GYP. BRD. EACH SIDE OF 2x4 WD. STUDS @ 16" O.C. w/ CONT. 2x4 SILL AND DBL. 2x4 TOP PLATES w/ R-11 BATT INSULATIONNON BEARING PARTITION - GARAGE WALL - 4" (U.N.O.)4" STEP DN.20 MIN.FIRE RATEDSELF CLOSING22'' x 54''ATTIC ACCESSFIELD LOCATE5X592495198109HARDIE BOARD PLANK SIDINGDIRECT APPLIED TO BLOCKw/ FASTENERS PER MFR'SSPECIFICATIONS78F8-1B-1T x 17'-2" L. U=187 / G=300 TYPE DESIGNATIONF = FILLED WITH GROUT / U = UNFILLEDGRAVITY LOAD8F16-1B/1TNOMINAL WIDTHNOMINAL HEIGHTADDED REBAR AT TOP OFQUANTITY OF #5 FIELDCOMPOSITE U-LINTEL FORUPLIFT LOADTOP OF COMPOSITE#5 FIELD ADDED REBAR ATU - LINTEL MIN. (1) REQ'D1-1/2" CLEARFIELD PLACED C.M.U.GROUT8" NOMINAL WIDTH7-5/8" ACTUALBOTTOM REINFORCING#5 FIELD ADDED REBAR ATPROVIDED IN U-LINTEL(SEE REINFORCING SCHEDULE)For a 5’-10” overall length U-lintel Type 8F16-1B/1T:Safe superimposed gravity load = 4360 PLFSafe superimposed uplift load = 2080 PLFSafe superimposed lateral load = 339 PLFBOTTOM OF U-LINTEL CAVITYBOTTOM OF U-LINTEL CAVITY FORQUANTITY OF #5 FIELD ADDED REBAR AT16" NOMINAL HEIGHT15-5/8" ACTUALBeamCompositeSafeGravityLoadAppliedGravityLoadSafeUpliftLoadAppliedUpliftLoad3'-0''<10003'-8''6113<5008F16-1B-1T4'-4"4'-6"4'-8"5'-6"5'-10"6'-2"7'-4"18437'-6"15687'-8"7'-8"8'-0"9'-0"14'-6"17'-10"20'-0"10'-4"10'-8"12'-8"PRESTRESSED8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1T8F16-1B-1TPRESTRESSED8F16-1B-1TPRESTRESSED8F16-1B-1T61136113611361131370950750<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<1000<100035243060<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500<500CASTCRETE PRECASTLINTEL SCHEDULE40534827072707270722762080208018681624162410721136113611369168006070536543604360348026612661184318431533136610754'-0"456123101112789131718191415162021<1000<500<1000<50022234'-4"10'-0"8F8-1B-1T8F8-1B-1T218964312075302425<1000<50010'-8"8F8-1B-1T<1000<5008F8-1B-1T8'-0"7255825904742614'-0"8F16-1B-1T<1000<50010025595'-4"8F16-1B-1T<1000<50053652276278F16-1B-1T<1000<5008'-8"11361843288'-4"8F16-1B-1T<1000<50011361843299'-4"8F16-1B-1T<1000<50011361843308F16-1B-1T<1000<50013'-8"60710753113'-4"8F16-1B-1T<1000<500107560732MASTERSUITE8'-0" FLAT CLG.GREAT ROOM2.5 / 12 VAULT(3 WAY)DINING2.5 / 12 VAULT(2 WAY)KITCHEN2.5 / 12 VAULT(2 WAY)M. BATH8'-0" FLAT CLG.W.I.C.8'-0" FLAT CLG.W.I.C.8'-0" FLAT CLG.W.I.C.8'-0" FLAT CLG.BEDROOM 48'-0" FLAT CLG.BEDROOM 38'-0" FLAT CLG.BEDROOM 28'-0" FLAT CLG.BATH 28'-0" FLAT CLG.HALL8'-0" FLAT CLG.PANTRYFOYER8'-0" FLAT CLG.COFFER TRAYSTO 9'-0"ENTRY9'-0" FLAT CLG.STUCCO FINISHGARAGE / WORKSHOP8'-0" FLAT CLG.ABOVE INT. FIN. FL.PORCH8'-0" FLAT CLG.T&G FINISH33<1000<5005'-4"8F8-1B-1T1663101630LAUNDRY8'-0" FLAT CLG.LANAI8'-0" FLAT CLG.T&G FINISHSLOPE 2'' OVERALL ISLAND:35 12" H. KNEEWALL2x6 STUDS @ 16" o.c.FLAT COUNTERTOPTYP. BOTH SIDES OF ENTRY:FRAMED BEARING WALLATOP CMU WALLTO 10'-9" A.F.F.2x4 STUDS @ 16" O.C.w/ 12" OSB SHEATHING ONEXTERIOR SIDEPRESTESSED2728CHRISTOPHER D. BEERS, P.E.FLORIDA LICENSE NO. 64594W A T E R - A I R - L A N D5109 Grand Palmetto WayNorth Port, Florida 34291-8049941-628-0635fax 413-687-9013chrisbeers@byu.net8FT. PIERCE, FL. 34987 10210 CARLTON RD. GEORGE & ANGELA MARTIRE LA TORTUGA GAM 511 SW PORT SAINT LUCIE BLVD. PORT ST. LUCIE, FL 34953P1 04 SEP 20P2 16 OCT 201/4" = 1'-0"la tortoga_MARTIRE8/07/20A2FLOOR PLAN3SHEETDESCRIPTIONDATEREVBuilder:Project:SCALE:OFMODELOWNERDESIGN BYCHECKED BY12345678